C-Bus Four Channel General Input Unit Installation Instructions

Similar documents
C-Bus Four Channel Analogue Output Unit Installation Instructions

C-Bus Reflection Range Installation Instructions

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

C-Bus Neo Range Installation Instructions. 5050NL Series

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

C - B u s C - T o u c h U s e r s G u i d e C T Series

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Light Level Detector, Surface Mount 5754PE. Installation Instructions

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

StarServe IR/RF Controller Installation Instructions. 2031RFT Series

Instruction Manual SCD24. Read this document prior to installation. Contents

C-Bus Black & White MK II Touch Screen. 5000CT2 Series. User s Guide

Square D Clipsal Outdoor Light-Level Sensor

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide ! WARNING. Components

4 & 8-POINT ANNUNCIATORS Instruction Manual

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

BC3250. Blowdown Controller

RS485 MODBUS Module 8AI

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

KT-100 Door Controller

Push Button Electronic Timer. 31VETR Series. Installation Instructions

OVEN INDUSTRIES, INC.

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

UNC100 Integra Manual

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

RMS/RPX Reader. User Manual

Carbon Monoxide Transmitter

Mains Power Filter 970MF10 970MF20. Installation Instructions

4 Channel Contact Closure SFP DIN Fiber Link System

AO Annunciator Module

Module Features are-configurable, no module jumpers to set

EOTec 2C32 Installation Guide

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

Push Button Electronic Timer. 31VETR3 Series. Installation Instructions

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

P2267 NETWORK INTERFACE

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Dimmer / Fan Controller Installation Instructions

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

Remote alarm indicator and test combination MK2430

LC1350 Level Controller

Alarm Tone Generator Model AG17

Universal fault annunciator for panel mounting

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Get connected with Xantrex Grid-Tie Inverters

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

LC2200 Level Controller Installation and Maintenance Instructions

General Routing Interface

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

Duct and Rough Service Carbon Monoxide Sensor

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Instruction Manual August sitrans CU 02

1.7. Insulation fault evaluators EDS460/490 EDS461/491

DESCRIPTION NOTE. Temperature and Humidity Sensors MODEL 1260B

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Datasheet: K-22 LO Sensor

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Segment design & and Bus Diagnostics

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

Universal Clamp Meter

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Pure Glass. saturn.clipsal.com

Substation Monitoring System

EXTINGUISHING AGENT RELEASE MODULE

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

DOCUMENTATION IPS640

Intelligent Single Loop Fire Alarm Control Panel

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

DOCUMENTATION IPS640

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

TER Active Room Temperature Sensor (Controller),

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

RE-PR3-E-27 3-Phase Panel Mount 27kW

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Ceiling Mounted Ducted Exhaust Fan Kit

Iconic Series ControlLink Pushbutton 41EPBM-VW PDL356PBSS-VW. Installation Instructions REGISTERED DESIGN

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

VAMP 120 & 121. Arc flash detection units. Product picture

RAYCHEM NGC-30 COMPONENTS

M7100 Pressure Transducer

Transcription:

C-Bus Four Channel General Input Unit Installation Instructions 5504GI Series REGISTERED DESIGN REGISTERED PATENT

Table of Contents Section...Page 1.0 Product Range... 3 2.0 Description... 3 3.0 Capabilities... 3 4.0 Compatible Inputs... 3 5.0 Wiring Instructions... 4 6.0 Connection to the C-Bus Network... 5 7.0 C-Bus Messaging... 6 7.1 Programming Considerations:... 6 8.0 Status Indicators... 6 8.1 C-Bus Indicator... 6 8.2 Unit Indicator... 6 9.0 C-Bus System Clock... 7 10.0 C-Bus Network Burden... 7 11.0 Power-Up Status... 7 12.0 Power Requirements... 8 12.1 C-Bus... 8 12.2 24Vac/dc Input... 8 12.3 24Vdc Output... 8 13.0 Power Surges and Short Circuit Conditions... 8 14.0 Megger Testing... 8 15.0 Standards Complied... 8 16.0 Programming Requirements... 8 17.0 Mechanical Specifications... 9 18.0 Electrical Specifications... 10 Copyright Notice Copyright 2003 Clipsal Integrated Systems Pty Ltd. All rights reserved. Trademarks Clipsal is a registered trademark of Gerard Industries Pty Ltd. C-Bus and C-Bus2 are registered trademarks of Clipsal Integrated Systems Pty Ltd. Intelligent Building Series is a registered trademark of Clipsal Integrated Systems Pty Ltd. All other logos and trademarks are the property of their respective owners. Disclaimer Clipsal Integrated Systems reserves the right to change specifications or designs described in this manual without notice and without obligation. Copyright 2003 Clipsal Integrated Systems Pty Ltd Page 2

1.0 Product Range 5504GI C-Bus Four Channel General Input Module (with 24Vac @ 500mA AUS plug pack) E5504GI C-Bus Four Channel General Input Module 2.0 Description The 5504GI Series C-Bus Four Channel General Input (CBGIM) products are C-Bus input devices. This extra low voltage device should be mounted in accordance to local wiring rules (AS/NZS3000 or equivalent). For ease of installation they are DIN rail mounted, measuring 8M wide (1M = 17.5 +0.5/-0.0 mm) wide. C-Bus connection is conveniently achieved through the use of RJ45 connectors, allowing similar units to be quickly looped together. Four independent input channels capable of measuring voltage, current and resistance are provided to control other C-Bus devices. 3.0 Capabilities The 5504GI Series C-Bus Four Channel General Input products are powered from the C-Bus and from an external 24Vac/dc supply. These units can generate a C-Bus system clock signal and apply a network burden. These units isolate the external power connections from the extra low voltage C-Bus Network. 4.0 Compatible Inputs The 5504GI Series C-Bus Four Channel General Input products are suitable for use to measure voltage, current and resistance in the following ranges. Input Specifications Range TTL Digital Voltage * (See Wiring Instruction 7) 0 to 5V dc 0 to 1V dc 0 to 5V dc 0 to 10V dc Current 0 to 20V dc 0 to 20mA 4 to 20mA Resistance 0 to 500 Ohms 0 to 1k Ohms 0 to 3k Ohms 0 to 10k Ohms All input ranges feature user selectable filtering at mains frequency (or if using dc supply, at 50Hz). Hysteresis, set during installation, is applicable to all inputs when determining if an action shall be performed. Important Note: The CBGIM is designed to monitor slow moving signals. All input signals are filtered using a median filter to reduce susceptibility to impulse noise. This means that signals faster than 10Hz cannot be followed. Maximum allowable input voltage for all ranges is +60/-20V. Voltages greater than this level may damage the CBGIM. Copyright 2003 Clipsal Integrated Systems Pty Ltd Page 3

5.0 Wiring Instructions 1. All sensors wired to the device shall use their own cable. No commoning of connections is allowed. 2. All sensor cables shall run at least 500mm from any mains wiring. 3. Where possible the use of twisted pair shielded cable is preferred, with the shield being connected to the 24Vdc common terminal. Maximum cable lengths are dependant on notes 4, 5 and 6 below. 4. The current loop connections are distance limited by the cable resistance and the voltage required across the current loop transmitter. In calculating this distance, take into account that the current loop sensing resistor will drop 5V across it at the 20mA level. The current loop connection requires that the 24Vdc output be used to supply power to the sensor. 5. The resistance ranges operate by injecting current into the sensor. This current is 500uA. Sensor self-heating must be taken into account. 6. The resistance ranges use a 3 wire resistance measurement technique that takes cable resistance into account up to 2000 Ohms. 7. An externally powered logic gate or transistor output is required for a digital input. C-Bus2 General Input 24 24 24 A 1 B A 2 B A 3 B A 4 B 24Vac In Tx R + - Logic Gate 0 Volts Current Loop Resistance Voltage Digital Figure 1. A typical wiring example NOTE: Care must be taken not to allow copper strands to enter the DIN unit s apertures. Rubber bungs are supplied (3 off) for unused RJ45 connectors, to stop foreign bodies from entering the unit. A maximum torque of 1.4Nm should be applied to the mains rated screw terminals. It is recommended that the General Input unit be segregated from the mains terminals by use of a separate enclosure. Please refer to local wiring standards for isolation requirements between mains and extra low voltage wiring terminations. Copyright 2003 Clipsal Integrated Systems Pty Ltd Page 4

6.0 Connection to the C-Bus Network Installation requires connection to the unshielded twisted pair C-Bus Network Cable. The illustration following, shows the recommended technique for cable termination giving the best electrical performance. It is required that Category 5 data cable is used, Clipsal catalogue number 5005C305B. C-Bus Category 5 Cable 5005C305B C-Bus2 General Input 2 8 1 7 CAT 5 Surface Box 4 6 SMRJ88A5/1 5 3 C-Bus Network C-Bus Patch Cord RJ5CB300PL RJ Pin C-Bus Connection Colour 1 Remote ON Green/White 2 Remote ON Green 3 C-Bus Neg (-) Orange/White 4 C-Bus Pos (+) Blue 5 C-Bus Neg (-) Blue/White 6 C-Bus Pos (+) Orange 7 Remote OFF Brown/White 8 Remote OFF Brown NOTE: The Remote Override (ON/OFF) functions are not available on this unit. It is recommended that the Remote Override (ON/OFF) connections be maintained for correct operation of these services across the C-Bus Network. Copyright 2003 Clipsal Integrated Systems Pty Ltd Page 5

7.0 C-Bus Messaging 7.1 Programming Considerations: The 5504GI Series C-Bus Four Channel General Input products can be programmed by connection to any operational C-Bus Network that is capable of supporting one or more extra C-Bus units (18mA current required) and a 24Vac/dc source. The unit can then be configured using the C-Bus Installation Software. 1. It is recommended that no more than 10 CBGIM units are on any one network. 2. Rapidly changing input levels will cause heavy C-Bus traffic and may lead to loss of other messages. Slowly moving input signals are preferred. 3. On noisy inputs, a higher level of hysteresis is recommended to reduce excessive messaging. 4. Too high a level of hysteresis could lead to total inoperability of the unit. 5. Select the longest time that results in acceptable performance for the Direct Level Sample Rate to reduce C-Bus traffic. 6. Global parameters must be set before channel parameters. 7. On heavy traffic systems, set the Broadcast timer to longer times to reduce traffic from the CBGIM. For further information about the programming this and other C-Bus units, please refer to the C-Bus Technical Manual (5000S/2, 5000M/2). 8.0 Status Indicators 8.1 C-Bus Indicator This indicator shows the status of the C-Bus Network at this unit. If sufficient network voltage and a valid C-Bus Clock signal are present then the OK signal will be displayed (continuous green light). If a Network is connected which has more current load than the power supplies can support, then this indicator will flash to show a marginal Network voltage. If there is no C-Bus Clock present then this indicator will not light. Indicator Status On Flashing Meaning Power on and functional Insufficient power to support Network No C-Bus Clock signal present; Further debugging of possible Network problems can be achieved with the Clipsal C-Bus Network Analyser tool (5100NA). 8.2 Unit Indicator Indicator Status On Meaning Normal operation No C-Bus connected Copyright 2003 Clipsal Integrated Systems Pty Ltd Page 6

9.0 C-Bus System Clock The 5504GI Series C-Bus Four Channel General Input product incorporates a software selectable C-Bus System Clock. The System Clock is used to synchronise data communications waveforms on a C-Bus Network. At least one active C-Bus System Clock is required on each C-Bus Network for successful communications. No more than three units on any C-Bus Network should have Clock circuitry enabled, so this option should normally be disabled using the C-Bus Installation Software. If a System Clock is required, it can be enabled from the Global Tab on the Graphical User Interface (GUI) for the unit. 10.0 C-Bus Network Burden The 5504GI Series C-Bus Four Channel General Input product incorporates a software selectable Network Burden. The Network Burden can be enabled using the C-Bus Installation Software. A Network Burden may or may not be required to ensure correct operation of the C-Bus Network. If in doubt, consult the C-Bus Calculator (Network Design Verification Software Utility) before proceeding with the hardware installation. CAUTION: The Graphical User Interface (GUI) software is designed to prevent the Burden from accidental selection. The following steps are required to correctly enable the Network Burden from the GUI: 1. Set the Unit Address to 001 ; 2. Turn to the Global Tab of the GUI; 3. Select the Network Burden check box; 4. Click the OK button; 5. Select Save to Network and/or Save to Database ; 6. Click the OK button; then 7. Repeat steps 3 and 4 within 20 seconds, to save your selection. To disable the Network Burden the same process applies except the Burden selection check box is cleared (remove cross). Important Note: Always disable all 5100 PC Interface Network Burdens before installing C-Bus DIN range products, which include a power supply (non P suffix versions). If a burden is required, use the built-in burden on the DIN Rail unit only. 11.0 Power-Up Status All C-Bus units have onboard non-volatile memory, which is used to store the operating state of the unit in case of power loss. On restoration of power the DIN Rail General Input unit initiates a short power-up diagnostic routine, which lasts for approximately 5 seconds. For further information about the programming this and other C-Bus units, please refer to the C-Bus Technical Manual (5000S/2, 5000M/2). Copyright 2003 Clipsal Integrated Systems Pty Ltd Page 7

12.0 Power Requirements 12.1 C-Bus The 5504GI Series C-Bus Four Channel General Input product draws 18mA from the C-Bus Network. Adequate C-Bus Power Supply Units must be installed to support the connected devices. If in doubt, consult the C-Bus Calculator (Network Design Verification Software Utility) before proceeding with the hardware installation. 12.2 24Vac/dc Input The unit requires the connection of 16-27Vac to the V(in) terminals 12.3 24Vdc Output The 24Vdc output is provided to supply power to external sensors and the current loop mode. This output is unregulated and is limited to 250mA. 13.0 Power Surges and Short Circuit Conditions The external 24Vac/dc voltage must be limited to the range specified. Power surge protection devices should be used to enhance system immunity to power surges. It is strongly recommended that overvoltage equipment such as the Clipsal 970 be installed at the switchboard. 14.0 Megger Testing Megger testing must never be performed on the C-Bus data cabling or terminals as it may degrade the performance of the Network. Megger testing of mains wiring of an electrical installation that has C-Bus Units connected will not cause any damage to C-Bus Units. Since C-Bus Units contain electronic components, the installer should interpret megger readings with due regard to the nature of the circuit connection. 15.0 Standards Complied Standard/Directive AS/NZS 1044:1995 IEC/CISPR14-1:1993 EN55014-1: 2000 CISPR14-1:2000 EN61000-3-2:2000; IEC61000-3-2:2000 EN60669-2-1:2000; IEC60669-2-1:1995 Title Limits and methods of measurement of radio disturbance characteristics of electrical motor-operated and thermal appliances for household and similar purposes, electric tools and similar electric apparatus Electromagnetic Compatibility (EMC) Part 3 Limits Section 2: Limits for Harmonic Current Emissions Switches for household and similar fixed electrical installations - Part 2: Particular requirements Section 1: Electronic switches 16.0 Programming Requirements The 5504GI Series C-Bus Four Channel General Input must be programmed to set a unique identification (Unit Address) and mode of operation on the C-Bus Network. C-Bus Installation Software can be used to configure the following: Copyright 2003 Clipsal Integrated Systems Pty Ltd Page 8

Project Name Part Name Unit Address Clock (Enable/Disable) Network Burden (Enable/Disable) Switching thresholds and hysteresis relationships The C-Bus Installation Software can be downloaded from the Clipsal Integrated Systems Web Site (www.clipsal.com/cis). For further information about programming this and other C-Bus units, please refer to the C-Bus Technical Manual (5000S/2, 5000M/2). Important Warning The use of any non-approved software in conjunction with the hardware installation without the written consent of Clipsal Integrated Systems may void any warranties applicable to the hardware. 17.0 Mechanical Specifications 144 65 85 All dimensions are in millimeters. No user serviceable parts inside. Copyright 2003 Clipsal Integrated Systems Pty Ltd Page 9

18.0 Electrical Specifications Catalogue No. 5504GI Series Nominal Supply Voltage Frequency Range(s) C-Bus Supply Voltage C-Bus Current Drawn AC Input Impedance Supply Current Drain With No External Loads 24Vdc (nominal) Output Voltage 24Vdc (Nominal) Current Source Capability Number of Input Channels 4 Input Voltage Ranges Maximum Input Voltages Input Voltage Range Impedance Input Current Ranges Current Sense Impedance Input Resistance Ranges Resistance Range Injection Current Basic Accuracy After Calibration 16-27Vac/dc 50-60Hz 15-36Vdc 18mA 100kΩ @1kHz A maximum of 10 units may be connected on a single C-Bus network 61mA 24Vdc ± 10% 250mA Total Inputs 0 1Vdc, 0 5Vdc, 0 10Vdc, 0 20Vdc -20< V < +60 Vdc >= 100 kω 0 20mAdc, 4 20mAdc 249Ω 0-500Ω, 0-1000Ω, 0-3000Ω, 0-10000Ω 500uA 0.5% of Full-Scale Maximum Input Frequency 10Hz (see text 4.0) Control Functions Electrical Isolation Status Indicators Load switching, Dimming, Trigger applications, Enable Control applications and Measurement applications 500V RMS / Input C-Bus Indicator Voltage 20V DC Voltage < 20V DC Voltage < 15V DC Unit Status Indicator On Clock Present On Flashing C-Bus Present Present Fail No Clock Present Conditions Normal Operations Maximum Number of Units on a Single C-Bus Network Start Up Time Network Clock Network Burden Dimensions Weight C-Bus Connections Operating Temperature Range Operating Humidity Range 10 5 seconds from application of DC supply Software selectable (Factory default is disabled) Software selectable 144 x 85 x 65 mm 190g 2 x RJ45 sockets 0-45 0 C 10 95% RH Copyright 2003 Clipsal Integrated Systems Pty Ltd Page 10

Copyright 2003 Clipsal Integrated Systems Pty Ltd Page 11

Further Information For further information about configuring this product and other C-Bus devices, please consult the documentation supplied. Further assistance can be obtained as follows: C-Bus Manuals The 5000M/2 C-Bus Technical Manual provides a comprehensive and definitive guide to Clipsal C-Bus. Includes hardware and software specifications, product datasheets, system design and installation guides, and software overview with fully worked programming examples. C-Bus Installation Software The 5000S/2 C-Bus Installation Software (includes 5000M/2 C-Bus Technical Manual) may be used to unlock the power and flexibility of Clipsal C-Bus. Unit operation may be completely customised to suit user requirements. Advanced control functions may be programmed. C-Bus Installer Training Courses Contact your nearest Clipsal Integrated Systems Sales or Technical Support icer and enquire about Clipsal C-Bus Installer Training and Certification Programs today!! Technical Support and Troubleshooting For further assistance, please consult your nearest Clipsal Integrated Systems Sales Representative or Technical Support icer. Technical Support Hotline 1 300 722 247 (Cost 25 per call, Australia Only) Technical Support Email techsupport.cis@clipsal.com.au Sales Support Email sales.cis@clipsal.com.au Clipsal Integrated Systems Website clipsal.com/cis Products of Clipsal Integrated Systems Pty Ltd ABN 15 089 444 931 Head ice 12 Park Terrace, Bowden South Australia 5007 International Phone +61 8 8269 0560 International Fax +61 8 8346 0845 Internet clipsal.com/cis E-Mail cis@clipsal.com.au 1036429