M E A S U R E M E N T S D I V I S I O N

Similar documents
Ronan Model X96S Series Weighing System

Ronan Model X96S Series Density System

Ronan Model X90 Series Point Level Monitor

Continuous and Point Level Measurement. Radiometric Sensors for Liquid and Solid Level Measurement

Technologies, Solutions, and Applications. Radiation-based Level

Technologies, Solutions, and Applications. Continuous Level Coke Drum Measurement System

MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT

Fixed-Point Interface Profiling. Multi-Point Density Array (MDA) Solution for Separation Applications

Products and performance

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Plant Security & Fire Alarm Systems. HVAC Systems. Power Plants & Switchyards. Geographical Maps. Industrial Process Plants

Troubleshooting Thermo Scientific LevelPRO Gauges

Dräger Polytron Pulsar 2 Open Path Gas Detector

A division of. Metal Detectors

SIL 2. Ultima X Series Gas Monitors CERTIFIED

GasGard 100 Control System

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Industrial Grade Gas Detection Detecting The Difference

IR 3000 WBPi Online Moisture Measurement with Infrared Technology

Maximizing safety and productivity. Nuclear Power Radiation Detection and Monitoring Solutions

Electronic Flow Switches

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

Temperature Solutions Line Card

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Contamination Control for Electronic and Semiconductor Applications

Dräger Polytron 7000 Fixed gas detector

Dependable Solutions for Gas Detection

SUPREMATouch Modular Fire & Gas Detection System

Dräger PIR 7200 Toxic Gas Detection Transmitter

Nuclear Density Gauges

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Alternative Fuel Fueling Stations

Weed Instrument Application Driven Designs for Pharmaceuticals and Biotech

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Instrumentation and Controls Group

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

SDM SERIES - SLURRY DENSITY METER PRODUCT INFORMATION CONTINUOUS IN-LINE MONITORING & PROCESS CONTROL

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

SPM Flex Chemcassette Tape-Based Gas Detector

Terminal Automation Solutions

Industrial Grade Gas Detection

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

15900 HVAC INSTRUMENTATION AND CONTROLS

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Radiation-based measurement Detectors

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Section B Field Instruments

PodView Level Indicator LI40 Series Manual

G-TECTA TM. Portable Gas Detection Instruments

FUNCTIONAL SAFETY MANUAL

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD

DensityPRO+ Gamma Density System with Remote Transmitter User Guide P/N Part of Thermo Fisher Scientific. Revision C

Neotronics portable gas detection. Portable protection from hazardous gas

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Model D12-IR. Digital Gas Transmitter...

Operating Instructions

The New DUSTTRAK II and DRX Aerosol Monitors

OPERATION AND MAINTENANCE INSTRUCTIONS MODEL 530 VIBRATORY LOSS-IN-WEIGHT FEEDER

HART XL High Sensitivity Smoke Detection

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions

Industrial Grade Gas Detection

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

HART XL High Sensitivity Smoke Detection

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Flexible Air-sampling Smoke Detection

Density, Concentration and Solids Content. Non-contacting measurement

Emerson s Pervasive Sensing strategies enable plants to realize full potential of Industrial IoT

SPM Flex Chemcassette Tape-Based Gas Detector

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

The New DUSTTRAK II and DRX Aerosol Monitors

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

Smarter Washing Solutions AGGST RM 150

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

laboratory & sterilization technology

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

LOW MINIMUM DETECTABLE ACTIVITY (MDA)

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

ue short form catalog Leaders in Safety, Alarm & emergency Shutdown

INTREPID Perimeter Intrusion Detection System

Metso MX. Multi-Action cone crusher

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

wireless. web-based. worthy of the name RACO.

Sitron s CF Line of Flow Switch Monitors

Explore the future of flow measurement. SITRANS FC430 - the most compact NTEP approved Coriolis flow meter. Process Instrumentation

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Electronic Pressure Digest. Pressure and Temperature Transmitters

WG Buried Cable Perimeter Detection System

EXCELLENCE in Solutions Products Service

LifeCycle Engineering & Field Services

Advanced FireAlarm Panel 1-4Loop

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

Ingersoll Rand kw Single Stage Contact-cooled rotary screw air compressors

Transcription:

M E A S U R E M E N T S D I V I S I O N

ACCURATELY MEASURING WHAT YOU DIDN T THINK WAS MEASURABLE Ronan Engineering, founded in 1959, is a privately held Corporation with the exclusive purpose of manufacturing leading-edge instrumentation that provides real-time monitoring of critical alarm points and measurements for process control in severe service environments. Fifty years of customer-focused research and development has enabled Ronan to provide industry-changing instrumentation that makes industrial plant operations safer and more efficient. Over our 50-year history, we ve established manufacturing, sales and service facilities in Valencia, California and Florence, Kentucky; secured a regional sales and support center in Washington, Tyne & Wear, United Kingdom; and have expanded our reach by adding Representative Companies around the world. Our worldwide network of dealers, 24-hour factory certified Field Service Engineers, and experienced staff of Applications Engineers are ready to assist with your measurement needs. RONAN MEASUREMENTS DIVISION Ronan Measurements Division supplies the process control industry with leading-edge Radiometric Measurement Systems that provide non-contact measurement solutions for the harshest environments. We are the only company exclusively dedicated to manufacturing Radiometric Measurement systems. Ronan offers the widest variety of Source Holder and Detector configurations on the market, including Source and Source Holders to meet every need, Detectors configurable to any shape or length, and a Transmitter that is compatible with all configurations and can be customized for special applications. Our Engineers work directly with you and your staff to customize the safest Radiometric Measurement system that also provides the most accurate results. With a philosophy of designing new products to be backward compatible, our customers have the confidence of an installed base of thousands of systems.

CAUTION RADIOMETRIC MEASUREMENT Radiometric Measurement provides a safe and efficient, non-contact method to measure liquids or solids in harsh process environments. The entire system mounts externally to the vessel or pipe and can be easily installed and maintained while the process is running without downtime, vessel modifications, risk of accidental release, or the need for specialty construction materials. Radiation Beam The receipt, possesion, use and transfer of this device is subjec to a genera license or equivalent authorization and the regulations of the US NRC or an agreement state. RLL Source Density Gauge SA-1 Source Radiation Beam X96SI/R Transmitter with FlexDetector APPLICATIONS AND INDUSTRIES Ronan instrumentation is used to make accurate measurements in even the most extreme process environments. Following is a list of measurement applications for which Ronan equipment is used: Continuous Level Measurement measures liquids or solids contained in a vessel, even one with an internal structure such as an agitator. Point Level Measurement detects and indicates the presence of material relative to a pre-selected level in process tanks, hoppers, chutes or vessels. Interface Level and Density Measurement is ideally suited for measurement of multiple stratified layers of process materials. Density Measurement is ideally suited for continuous density measurement of liquids, slurries, and solids contained in a pipe or vessel. Mass Flow Measurement makes mass flow calculations using the density system with an input from a volumetric flow meter into the density Transmitter. Continuous Weight Measurement is ideally suited for weighing materials on belt conveyors, screw conveyors, drag chain conveyors, and metal plate conveyors. Radiometric Measurement is ideal for industries including: Mining and Aggregates Power Refining, Oil and Gas Chemical Metals Pulp and Paper Dredging Cement Glass Food and Beverage Radiometric Measurement can accurately measure process material even when materials to be measured are caustic, corrosive, toxic, carcinogenic, explosive, or sterile; abrasive or highly viscous; held at extreme temperatures or under high pressure; in a process flow that is violent or constantly changing; contained in a vessel with an internal obstruction.

X96S DenSITY SYSTEM The X96S Density System is designed to deliver outstanding performance in a wide range of difficult applications and process conditions. Each system consists of a gamma source, detector and Ronan X96S Microprocessor. The detector measures the level of energy being emitted from the source and sends a proportional signal to the Microprocessor. The Microprocessor filters and correlates this signal to a density/percent solids measurement. The user can select from a list of units of measure for the desired reading. The entire system can be easily installed while the process is running. Ronan Microprocessor Features: System Integration via HART or Foundation Fieldbus Local display shown in HART format Optional local and/or remote eight line display Flexible, modular design permits customization Isolated digital and analog I/O, software settable NEMA 4, 4X enclosure or rack-mount chassis X96S Non-Contact Density System with Microprocessor X96S Non-contact weighing system The X96S non-contact weighing system is an economical approach for solids weighing on belt and screw conveyors. Each system consists of a gamma source, frame, detector and Ronan X96S Microprocessor. Applications: Solids non-contact measurement Measurement not affected by dust, moisture, high temperature, corrosive, abrasive or toxic materials Variable or constant speed conveyors Features: X96S Non-Contact Weighing System Low maintenance/no component wear Multiple user-configurable outputs Auto-zero on empty conveyor Excellent measurement reliability due to proprietary filtering technology

Source & Source Holders You can be confident in your safety with Ronan Measurement Systems with all gauges meeting As-Low-As-Reasonably-Achievable (ALARA) guidelines. Source activity is customized depending on vessel and process parameters such as diameter, wall thickness, material, and measurement span to ensure optimum sensitivity, economy and safety while keeping the source activity to a minimum. Ronan is the only manufacturer to offer the revolutionary Radiation Low Level (RLL) source holder. The RLL uses up to 100 times less gamma energy than comparable gauges, and is the only source holder recognized by the NRC to be so safe that it does not require the stringent documentation, training or handling procedures of other systems. The RLL system can be used on applications up to 16 pipes with no reduction in source longevity. RLL Low-Level Source Holder Other features of the RLL Source: Source lasts as long as standard installation Generally licensed device, reduces paperwork and cost Does not require wipe testing, saving you time and money Does not require on-off shutter checks or radiation surveys No RSO, radiation training or factory assistance is required to install and use these devices safely as long as instructions supplied by Ronan are properly followed Device may be relocated by plant personnel, without a licensed person present More Ronan Source HOlders SA-1 and SA-8: External Mount general purpose source holders GS-200 and GS-300 External or well mount source holders SA-4, SA-10, SA-15 Well mount source holders GS-400 External mount fi re p ro o f source holder

Detectors Ronan offers a wide variety of detectors to meet any installation requirement. Having pioneered the use of solid crystal scintillation detectors more than 20 years ago, our worldwide installed base numbers in the thousands across a wide variety of applications. Ronan employs three types of scintillation crystals: Fill Fluid, Plastic, and Sodium Iodide for ultra low-level fields. Scintillation detector Features: High detector efficiency Detector lengths up to 15ft active length; up to four detectors can be summed for a total measurement range of 60 feet (18.4 meters) Spring tension of PM tube - Maintains integrity of the signal path under vibration Ronan quality manufacturing-backed by a 3-year limited warranty Scintillation Detector FlexdetectoR Ronan s patented FlexDetector utilizes a non-hazardous, non-flammable scintillating fill fluid which is protected by an outer sheath of armored conduit. The FlexDetector contours to the shape of any vessel, including horizontal or spherical vessels, or areas of the vessel where space is limited. Other benefits of FlexDetector : Up to 23 feet and multiple detectors can be summed for continuous level measurement of any length Lightweight construction and can be shipped via regular commercial carrier Backward compatible allowing for system upgrade with a new detector Integral or remote transmitter Spring tension of PM tube maintains integrity of the signal path under vibration and when detector is mounted inverted Improved linearization over the entire range of active length FlexDetector

Transmitter Ronan s X96SI/R Transmitter is compatible with all Ronan scintillation detectors. The integrally-mounted transmitter includes a patented optical coupling that allows the transmitter and detector electronics assembly to be easily mounted to any detector configuration. Fully Ethernet capable, configurations, software updates, and data logging can be completed easily through the user s PC using a standard web browser. The system is menu-driven for simple programming. Built-in intelligence provides a range of features including: Automatically compensates for vapor density changes, foam or gasses, process build-up Automatic source decay compensation Radiation discrimination State of the art dynamic tracking of process fluctuations Data logging and event recording Empty pipe alarm The X96SI/R is available in explosion proof or weatherproof housing. Ronan Transmitters are compatible with the following I/Os: Ethernet, HART, USB port, 4-20 ma or 0-10 VDC, relay(s) output, and transistor type. Radiometric Transmitter TRAINING Ronan s product training courses are designed to help you engineer, operate, maintain, and manage your radiometric systems to achieve peak plant and process performance, as well as greater uptime and profitability. 40-hr. Radiation Safety Officer Certification Course 2-Day Safety Course 8-hr. Safety Class Technical Training 4-hr. Basic Radiation Safety Awareness RONAN SERVICE Our Global network of factory certified Field Service Engineers are trained not only on Ronan products, but also on your applications. They bring expertise to help you determine the optimal configuration for your application to ensure accuracy and safety. Ronan Service Representatives are available to help you with: Installation and Start-Up Wipe Tests Personalized Training Radiation Auditing Preventative Maintenance Source Disposals Service Agreements Contact our Field Service Group: (859) 282-4721 fieldservice@ronanmeasure.com

Ronan Engineering Company Measurements Division 8050 Production Drive Florence, KY 41042 USA (859) 342-8500 Fax: (859) 342-6426 www.ronanmeasure.com email: ronan@ronanmeasure.com Service Department Phone: (859) 342-8500 Fax: (859) 342-6426 Emergency: (859) 282-4721 email: fieldservice@ronanmeasure.com Ronan Engineering Company Corporate Headquarters 28209 Avenue Stanford Valencia, CA 91355 USA Phone: (661) 295-6000 Fax: (661) 295-6063 www.ronan.com email: sales@ronan.com Ronan Engineering Limited U.K. 1 Tilley Road Crowther Industrial Estate Washington, Tyne & Wear, U.K. NE38 OAE +44 191-416-1689 Fax: 191-416-5856 www.ronan.com email: sales@ronaneng.co.uk Ronan Representatives Ronan has a qualified pool of representatives in the U.S. and around the world. To find representative in your area visit www.ronan.com. RONAN ENGINEERING July 2014