GL-CO-RFG Channel Gas Leak Alarm System

Similar documents
COSTER. Code Internal Alarm Pre-alarm Suitable sensor threshold threshold external sensor

Water Detection Controllers

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

Electronic control unit for gas leak detection with 4 detection zones

BX444-Mc Gas Detector

GS100M Gas Detection Controller

GS100M Gas Detector. Technical Specification

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

Gas leak detection system. for heating rooms and similar environments. Description. Sensor for methane gas IP44. Sensor for LPG gas IP44

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

Two-Channel Gas Controller

KAE Gas Alarm Operation Manual

BX444-M Gas Detector. Features. Application. Operation

Warranty Registration

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

Four Channel Gas Detection System AGDS 4. The Home of Control & Automation in Ireland

AT-G-SENSE Gas Sensing System

GS100M Gas Detector. Features. Application. Operation

CHCO Double Gas Detector

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

KAB Gas Alarm Operation Manual

Oxygen (O2) Single-Point Gas Detection System

TC100N. Fixed Gas Detector Operation Manual

GS300M Gas Detector. Features. Application. Operation

Snifter ATEX22 VERSION. User Manual. Distributor

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Zareba Metro Gas Detector

10yr O2NE & Safe-Ox. User Manual

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Merlin Gas Detectors. Rev: 09 Date: Product Data Sheet

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

Combustible Gas Detection and Control System

Warranty Registration

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Snifter. User Manual. Distributor

QD6310. Fixed Gas Detector Operation Manual

LC3000 Level Controller Installation and Maintenance Instructions

TECHNICAL CATALOGUE GAS LEAK DETECTOR AND SOLENOID SAFETY VALVES

Gas Safety Products. Installation, operating and maintenance. Merlin 1000BH Gas Proving/Gas Detection System

Multi Channel Gas Detection System AGDS MC. The Home of Control & Automation in Ireland

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

GAS MONITOR Model Model

Sintrol Snifter A1+ Manual. Version 1.2.2

Carbon Monoxide Transmitter

Dräger Polytron 5700 IR Detection of flammable gases and vapours

AT-G-DETECT Gas Sensing System

CP01 Fixed gas detector

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

ASHRAE Safety Standards. Mechanical Rooms and Gas Detection in Commercial Applications

KSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR. Instructions for :- KSGD-01W/S Semi Conductor Standalone Refrigerant Leak Detector

XLH210: controller for gas leak detectors

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

AT-G-SENSE Gas Sensing System

Danfoss gas detection units

RE-PR3-E-27 3-Phase Panel Mount 27kW

Operating Instructions. For. Alarm Control Module. Model SSR 500

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Macurco HD-11 Hydrogen Gas Detector

INSTALLATION AND OPERATING INSTRUCTIONS

Operation and Maintenance Manual

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

PolyGard 2-channel Gas Controller MGC-03

Dixell Installing and Operating Instructions release 7.0

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

ANALOX 3000 Carbon Monoxide Monitor

GD Series Gas Alarm Operation Manual

(CH 4 ) METHANE GAS DETECTOR AE09/GM, AE09/GM-12, AE09/GM-24

Operation Manual. Rev. D GEM-II Self-Contained Gas Detector.

Control Unit BX280 CONFORMITY EN EN EMC EN Isntallation and user Guide. Firmware Version 9.0

Operations Manual GMA 313 CO 2. Gas Monitor for one detection point

Gas Safety Products. Installation, operating and maintenance. Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System

Gas Detection System TOX ALARM DG2000-Garage

G.O.L.D. GAS OPERATIONS LEAK DETECTION USER MANUAL

TECHNICAL INSTRUCTIONS

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Macurco CM-21A Carbon Monoxide

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

MGD - Murco Gas detector / Monitor. Installation & Operation* 08 ASH (1)

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Pioneer-R16 Gas Monitor Operator s Manual

Installation & Operation

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

Transcription:

Four Elms Road Edenbridge Kent TN8 6AB UK Features & Benefits Remote sensors for natural gas, LPG and CO 1 x SPST relay outputs DIN-rail as standard, panel mounting kit available Adjustable alarm thresholds Self-diagnosis fault system Audio & visual alarms Technical Overview The CL-CO-RFG361 is a single channel gas leak alarm system, that is designed for the detection of gas leaks in spaces such as boiler plant rooms, workshops and other industrial gas installations, to provide safety alarm and shutdown facilities on detection of gas leakage. Product Codes Controller 1 Channel gas leak alarm system (DIN rail mount) Mounting option GL-CO-FMK3 Panel mounting kit Sensors GL-CO-SRS-150 Natural gas sensor GL-CO-SRS-250 LPG, Propane sensor GL-CO-SR-S350 Carbon Monoxide sensor Specification Power supply 230Vac ±10% @ 50/60Hz Power consumption 3VA Radio disturbance VDE0875/0871 Vibration test with 2g (DIN 40046) Relay output SPDT, 250V @ 5(1) A Housing dimensions 115 x 53 x 70mm Housing materials: Cover ABS Base Nylon Housing protection IP30 Sensor dimensions 77 x 77 x 44 Sensor material Nylon Sensor protection IP44 Ambient: Storage temp. -25 to + 60 C Operating temp. 0 to 45 C RH Class F Din 40040 Country of origin Italy WEEE Directive: At the end of the products useful life please dispose as per the local regulations. Do not dispose of with normal household waste. Do not burn. The products referred to in this data sheet meet the requirements of EU 2014/30/EU and 2014/35/EU Page 1 of 5

Four Elms Road Edenbridge Kent TN8 6AB UK Siting of Devices Detectors These must be sited in a dry space which meets the relevant ambient requirements. If installed in a location classified as Hazardous it must be installed in a cabinet for electrical equipment constructed according to the regulations in force for the class of danger concerned. The controller can be mounted on a DIN rail and housed in a standard DIN enclosure. Sensors The correct siting of the sensor is fundamental for the correct functioning of the system. The position depends on the type of gas to be monitored and, in particular, on its density in respect of air: Methane (gas lighter than air which therefore tends to rise). Position: at a distance of 10 to 50cm from the ceiling and, in any event, above doors or windows. Propane (LPG) (gas heavier than air and so tends to move downwards). Position: at a distance of 10 to 50cm from the floor. Carbon monoxide (CO) (gas with a density very similar to that of air and which therefore tends to diffuse uniformly) Position: at a height of 150 to 200cm from floor. Moreover, to ensure the correct operation of the detector and to avoid useless alarms due to a casual and momentary presence of gas, the sensor must NOT be positioned: Less than 1 to 2 metres from boilers or water heaters, Less than 2 to 3 metres from kitchen ranges and ovens, In spaces where air movement could be hindered (e.g. in corners or enclosed spaces), Near to doors or windows, Near to air extractors, In places where dust or dirt could contaminate the sensor and so render it ineffective, In places subject to possible sprays of water, particularly sensors positioned near the floor, In places where the temperature or humidity could be outside the limits stated. Solenoid shut-off valve This must be installed on the gas distribution pipe, taking the following precautions:: If possible, in a different space from the one being controlled, In an easily-accessible place, especially for the valves which have to be reset manually. If installed outside, it must be protected against the weather, In installations with external propane (LPG) gas tank, it must be installed downstream of the pressure-reducing valve (30 to 40 mbar). Alarm Levels Methane Alarm methane 0.5 0.8 1.25 % 5,000 8,000 12,500 ppm Pre-alarm methane 0.3...0.5...0.8 % 3,000...5,000...8,000 ppm Carbon monoxide (CO) Warning: in detecting carbon monoxide (CO), the levels and intervention times are processed and controlled by a microprocessor. The Sensitivity control must be set in the 0 position. Propane-GPL Alarm propane-lpg 0.22 0.35 0.56 % 2,200 3,500 5,600 ppm Pre-alarm propane-lpg 0.14...0.22...0.35 % 1,400...2,200...3,500 ppm Carbon monoxide-co alarm: "threshold + time" < 50 ppm: no alarm 50...100 ppm: 60 minutes 100...300 ppm: 10 minutes >300 ppm: immediate alarm Carbon monoxide-co pre-alarm: Time between exceeding alarm threshold and alarm Page 2 of 5

Four Elms Road Edenbridge Kent TN8 6AB UK Installation 1. The GL-CO-RFG361 should only be installed by a competent, suitably trained technician, experienced in installation with hazardous voltages. (>50Vac & <1000Vac or >75Vdc & 1500Vdc) 2. Ensure that all power is disconnected before carrying out any work on the GL-CO-RFG361. Maximum cable is 2.5mm², care must be taken not to over tighten terminals. 3. Separate the base from the cover, if DIN rail mounting clip onto the DIN rail. 4. Make connections as required using the following cables: 1.5 mm2 cross-section for power and relay control outputs, 1 mm2 cross-section for sensors positioned up to a maximum distance of 50 meters; or 1.5 mm2 cross-section for sensors positioned up to a maximum distance of 75 meters. 5. NB It is advised that no more than 2 cables be inserted into a single terminal. Use external junction boxes if necessary. 6. Select the link functions to adapt the detector to the desired type of operational control. Fascia & Wiring Sensitivity adjustment Basic operation: Solenoid valve N/C: Operational control Power LED Fault Alarm Reset button Links Warning, when changing link functions ensure all power is disconnected first. Link Functions: M - F1 F3 - F4 No link Internal buzzer enabled No link Relay with latching alarm Linked Internal buzzer disabled Linked Relay with non-latching alarm F2 - F3 No link Linked Relay normally energised when no gas present Relay normally de-energised when no gas present Latching alarm & reset: F3 - F4 linked: Alarm ceases when the gas concentration falls below the threshold level and the ALARM LED blinks slowly. Press the RESET button to clear the LED status. F3 - F4 unlinked: Alarm continues even when the gas concentration falls below the threshold level. To deactivate press the RESET button for at least 5 seconds. Page 3 of 5

Four Elms Road Edenbridge Kent TN8 6AB UK Operation Switching on When it is powered the GL-CO-RFG does not start detecting immediately and does not signal any alarm for the first two minutes of operation. This is the time necessary for the gas-sensing elements to become stabilised so that their readout can be considered accurate and reliable. This period for the stabilisation of the sensors is indicated, on the facia of the detector by the flashing of the FAULT and ALARM LEDs. At the end of the stabilisation period the FAULT and ALARM LEDs, in normal situations, switch off. Type of Fault Fault LED Alarm LED Sensor self-heating element broken ON OFF No connection to terminal G ON OFF No connection to terminal B ON OFF No connection to terminal M OFF ON Connections G & B reversed ON OFF Connections G & M reversed OFF ON Connections B & M reversed OFF ON Pre-alarm and alarm thresholds for methane and propane-lpg) By means of the SENSITIVITY knob, the intervention threshold (sensitivity) can be increased or decreased according to the particular conditions of the space in which the sensor is positioned, or for specific requirements: Knob towards + = increase of sensitivity. Knob towards - = decrease of sensitivity. These adjustments, however, remain within the limits required by the regulations so it is always possible to intervene under conditions of the maximum safety. The intervention levels, referred to the LEL (Lower limit of Explosivity) = volumetric ratio in air of combustible gas or vapour below which an explosive mixture is not formed) for the gases methane and propane LPG are as follows (the threshold values with the SENSITIVITY knob = 0 are shown in bold type): Type of gas LIE Pre-Alarm Alarm threshold Methane 5% 0.2..0.5..0.8% 0.5..0.8..1.25% 50000ppm 3000..5000..8000ppm 5000..8000..12500ppm Propane (LPG) 2.10% 0.14..0.22..0.35% 0.22..0.35..1.25% 21000ppm 1400..2200..3500ppm 2200..3500..5600ppm Pre-alarm and alarm threshold for carbon monoxide (CO) The danger of carbon monoxide (CO) does not derive from its inflammability or the danger of explosion, but from its very high toxicity to the human body. Moreover, its danger does not depend only on the concentration of the gas in air, but also on the length of time a person has remained in an atmosphere in which this gas is present. The pre-alarm and alarm levels of the sensor are determined by the processing of a microprocessor which takes into account the concentration of the gas in the air and the exposure time. For this reason the Sensitivity knob on the detector must not influence the sensor readout and, even if there is only one carbon monoxide (CO) sensor, it must be set in 0 position. If the pre-alarm threshold is exceeded, this is indicated, on the detector facia, by the intermittent lighting of the ALARM LED for the sensor which has detected the anomaly. The intervention modes of the detector are accordingly as follows: Concentration < 0.005% (50 ppm): the safety of the persons is guaranteed for an indefinite length of time and so the detector does not intervene, Concentration 0.005...0.01% (50...100 ppm): within this concentration range, for 60 minutes the detector signals a Pre-alarm situation and after this period switches to Alarm. Concentration 0.01...0.03% (100...300 ppm): within this concentration range, for 10 minutes the detector signals a Pre-alarm situation and after this period switches to Alarm. Concentration > 0.03% (300 ppm): the safety of the persons present in the space is not guaranteed. The detector immediately switches to the Alarm state. The concentration values and times taken into consideration by the detector have been established allowing a large safety margin to ensure there is no danger to the persons. The action of the detector is of the Dynamic type: if the concentration passes from one level to another, the time calculated increases or decreases as a consequence, thereby modifying the response of the detector. In particular, should the concentration of carbon monoxide (CO) return below 0.005% (50 ppm) for more than one minute, the detector returns to the Normal condition, cancelling all the times counted up to that moment and, if it has been programmed Without latching any Alarm condition will be terminated. Page 4 of 5

Four Elms Road Edenbridge Kent TN8 6AB UK Commissioning Power the device: LINE LED lights and FAULT LED and ALARM LED flash. After 1.5 2 minutes the detector is enabled to acquire alarms and the LEDs FAULT and ALARM should go out. Position the SENSITIVITY knob on "0". Since the sensors are selective, and so not influenced by gases other than that for which they are dedicated, to simulate the presence of gas it is necessary to use small gas cylinders containing specific gases at preset concentrations, releasing the gas as near as possible to the detecting sensor. Only for sensors for detecting propane (LPG) can gas from a normal cigarette lighter be used. When the gas concentration exceeds the pre-alarm threshold the ALARM LED flashes. With a delay (about 20 seconds) after exceeding the alarm threshold: o ALARM LED lights and stays lit. o The internal alarm and the outside warnings (only if without jumper M-F1) are switched on. o The operational relay closes the gas shut-off valve or switches on the aeration fan. Stop erogation of gas. When gas concentration on the sensor returns below the threshold level: o If detector is without latching (with jumper between F3-F4), alarm ceases and ALARM LED remains flashing slowly until RESET button is pushed o If detector is with latching (without jumper between F3-F4), alarm remains until RESET button is pressed for at least 5 seconds. If the detector controls a valve with manual reset, it is necessary to re-open manually also the valve. Whilst every effort has been made to ensure the accuracy of this specification, Sontay cannot accept responsibility for damage, injury, loss or expense from errors or omissions. In the interest of technical improvement, this specification may be altered without notice. Page 5 of 5