COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

Similar documents
Glass Door Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Refrigerator Freezer Installation and Operation Manual

Ice Cream Freezer Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Refrigerator Freezer Installation and Operation Manual

Horizontal Bottle Cooler Installation and Operation Manual

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

Refrigerator Freezer Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Full Stainless Steel Visible Exterior. Turbo Air Speed up the Pace of Innovation REFRIGERATOR

Chef Base Refrigerators Installation and Operation Manual

Worktop Refrigerators & Freezers Installation and Operation Manual

Undercounter Refrigerators & Freezers Installation and Operation Manual

Turbo Air Speed up the Pace of Innovation REFRIGERATOR MUR-28 MUR-36 MUR-48 MUR-60 MUR-72 REFRIGERATOR MUF-28 MUF-48 MUF-60

Turbo Air Speed up the Pace of Innovation REFRIGERATED CASE CRT-77-1R CRT-77-2R

INSTRUCTIONN MANUAL. for Angle Curved MMF9106 MMF9109 MMF9112

Installation & Operation Manual Ice Cream Freezers

PREP TABLES AND UNDERCOUNTER REFRIGERATION INSTRUCTION MANUAL

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

Cooking Equipment. Who we are

Ice Cream Dipping Cabinets Installation and Operation Manual

GENERAL PURPOSE REFRIGERATORS ABT-9R, ABT-14R, ABT-17R, ABT-20R, ABT-30R

INSTALLATION AND OPERATION MANUAL

OWNER S GUIDE. Hazardous Locations Refrigerator and Freezer with Mechanical Temp Control. Table of Contents

MIM-500FA, MIM-650FA, MIM-900FA, MIM-1000FA

This manual describes how to operate and care for your appliance to get the best, most efficient, performance. READ THIS BOOK!

Full Stainless Steel Interior and Exterior. Turbo Air Speeds up the Pace of Innovation

Zeus Extreme Owner's Manual

This manual describes how to operate and care for your appliance to get the best, most efficient, performance. READ THIS BOOK!

Owner s Manual-Futura Silver Series 16 Cu. Ft. Dual Temp Refrigerator/Freezers OWNER S INSTRUCTIONS READ THIS BOOK!

OWNER S GUIDE. Undercounter Freestanding Refrigerator & Freezer with Mechanical Thermostat Temp Control. Table of Contents

REFRIGERATOR AND FREEZER UNITS FOR HAZARDOUS LOCATIONS MODEL: LABH 30RX, 30FX, 30DTX, 20RX, 20FX, 17RX, 17FX, 14RX, 14FX OWNER S INSTRUCTIONS

COMPACT REFRIGERATOR

UNDERCOUNTER & WORKTOP FREEZERS

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

Superdryer Dehumidifiers

OPERATING INSTRUCTIONS

Field Top Mounted Condensing Unit

Horizontal Bottle Coolers and Glass Frosters Installation and Operation Manual

WatchDog NXT60. Installation and Operations Manual. Seaira Global, LLC NC Highway 50 Surf City, NC (910)

Part No Revised: October 2004 BUN WARMER. Instruction Manual. Models:8018,8019,8117,8219,8170

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

PATRIOT INSTRUCTION MANUAL FMFW-1500W/C FULL SIZE COOKER/WARMER

INSTALLATION AND OPERATING MANUAL

OWNER & OPERATOR INSTRUCTION MANUAL

M3 Series Undercounter Refrigerators & Freezers Installation and Operation Manual

RPI Industries, Inc.

TAC (TRUE AIR CURTAIN MODELS)

2018 PRICE LIST EffecTiVe 10/01/2018

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

ST-120/2 ST-120/3 ST-240/4 Steam Table

IW-25-2 Dehumidifier Installation & Operations. Manual

INSTALLATION AND OPERATING MANUAL

OWNER S GUIDE. Flammable Material Storage Freezer with Alarm System & Microprocessor Temp Control V5.2. Table of Contents

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Instruction Manual for the Chefmate Countertop Soup Warmer Model CPSKB1

Part No Revised: June TS1 TOASTER SYSTEM Instruction Manual Models # 5700 AND # 5700SF

HD-26, HD-36, HD-48 Heated Displays

Hot Dog Roller Grills

Instruction Manual Refrigerated Counter Top Displays

Super Deluxe Series Sandwich/Salad/Mega Top Units Installation and Operation Manual

MODEL (Single Door) MODEL (2 Door pass through)

Instruction Manual. Cheese Warmer with Pump

OWNER S GUIDE. Pharmacy, Laboratory, & Chromatography Glass or Solid Door(s) & Stainless Steel Refrigerator with Microprocessor Temp Control V1.

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

RPI Industries, Inc.

PREMIER CUBE FREEZERS, UNDERCOUNTER FREE STANDING & MID-SIZE REFRIGERATORS

COMMERCIAL REFRIGERATORS AND FREEZERS

INSTRUCTIONS AND WARRANTY

RPI Industries, Inc.

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

TH MODELS - (HEATED CABINETS)

OPERATING INSTRUCTIONS

TCM MODELS (CONVENIENCE MERCHANDISER)

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

InstructIon Manual KrEs EQuIPMEnt stands

RC-E25, RC-E30, RC-E50 Rice Cooker

CUBE ICEMAKER MODELS SCU25, SCU35, SCU45, SCU75, SCU95, SCU120 INSTALLATION AND SERVICE MANUAL VERSION 2

Operation Manual For Sodir. Finishing Ovens SEM-60/80 Q/VC

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST Bottom Mount Reach-Ins

5300, 5300CH, 5300EX, 5300FN

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

Super Deluxe Series Underbar Equipment Installation and Operation Manual

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

Cincinnati, OH USA

Part No Revised November / Instruction Manual Model #8150 AND #8151

Portion Bag Cheese Warmer

Part No Revised December 2002 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5510, 5511 AND 5512

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

US 11/2005. Greens Machine VP-1/VP-3 Salad & Vegetable Dryer VP-1 VP-3. Instruction manual

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

OWNER S GUIDE. Undercounter & Mid-Size Laboratory Refrigerator & Freezer with Temp Display System V5.2. Table of Contents

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

INSTALLATION AND OPERATING MANUAL

J Series Refrigerators & Freezers Installation and Operation Manual

USE & CARE INSTRUCTIONS 10- SPEED HAND MIXER FSHM100

Transcription:

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL Model No.: TGM-69R FEATURE CHART ADVERTISING PANEL FLOURESCENT SWITCH COOLING FAN FLOURESCENT LAMP EVAPORATOR INNER DRAIN PAN SHELF DOOR HANDLE GLASS DOOR CONDENSER BOTTOM GRILL DRAIN PAN ADJUSTABLE FOOT COMPRESSOR FRONT SIDE Before operating this unit, please read these instructions completely.

HOW TO INSTALL In good ventilation. Place the refrigerator in well ventilated area for better cooling. Place the refrigerator on hard and level floor. Unlevel floor may cause the refrigerator to make noise. Put away heat source from the refrigerator. High ambient temperature will make cooling efficiency lower. Install the refrigerator indoor do not get unit wet. This unit is designed for indoor usage only. Avoid places that are exposed to smoke. The discoloring can occur to the refrigerator. Place the refrigerator in an area with low moisture. Splashing water or a high moisture area may cause short circuit and make rusting easier. Ambient temperature should be below 85 F. Warmer temperature will cause problems with cooling efficiency. Set the front of the refrigerator a little bit higher than back-side by using adjustable feet to drain the water away with easily. Adjust the temperature in the refrigerator. Controller is attached to the right to the upper. Set the temperature control at normal position. NORMAL Set the front side higher than back side. COLD COLD COOL OFF NORMAL 2

CLEANING Caution Unplug the power cord before cleaning. Clean the refrigerator periodically. Do not use the abrasive cleaners, solvents or polishing agents on plastic parts. These cleansers may cause cracking or discoloring. Cleaning the interior and exterior Wash it with warm and soapy water and rinse, and dry it. Wash the shelf with water. Dewdrops in rainy-season, wipe it with a dry cloth. Check points after cleaning Check again the refrigerator for safety. Do not plug the power cord with wet hands. Check the noise or overheating. Compressor Condenser should be cleaned every 3 months or as needed, unit will not cool properly if dirty. Especially, be sure to clean the condenser before reoperating, after a long period of non-operation. 3

CAUTION Ventilation - Place the refrigerator under proper ventilation - Keep the cabinet 4 from rear wall. Warning - It is the responsibility of the purchaser in case of followings. Compressor under low voltage Compressor more than 7 feet from plug-in connection. Compressor under unstable voltage Compressor not under 115V/60Hz Start-up - Plug the power cord into the wall outlet. - The outlet should be only for the refrigerator. - The temperature controller should be on normal position. - If disconnected, shut down, wait 5 minutes before re-starting it. Temperature control - To keep the temperature down : Turn the dial CW. - To keep the temperaure up : Turn the dial CCW. 4

BEFORE REQUESTING SERVICE SYMPTOMS CAUSES SOLUTIONS When product freezes. Because of the differences between ambient temperature and a quantity of food stored, when the temp. dial is on the cold position. Turn the temp. dial to the cool position. When the refrigerator does not refrigerate at all. When the refrigerator does not refrigerate well. When there is a severe noise. When there are dewdrops on the refrigerator exterior. When there are dewdrops in the refrigerator interior. When the door does not close tightly. Food would freeze in ambient temperature of below 41 F and the temp. dial on the cold position. When there is a power connection or failure problem. When the refrigerator is in sunlight or near a heating device. When the refrigerator contains hot food or too much food. When the refrigerator door is opened too frequently or left open long. When the temp. dial is not on the correct position. When the condenser is dirty. When the installation floor is weak or the adjustable feet is set incorrectly. When the back-side of the refrigerator is close to the wall. When the tray is not on the correct position. High-moisture air can produce dewdrops during the rainy season. When the refrigerator door is opened too frequently or left open long. When damp food is stored. When the door has a slant. When the place is not level. Turn the temp. dial to the cool position. Check the power cord and plug it. Check the installation place. Check the condition of stored food. Check the position of the temp. control dial. Clean with brush or vacuum. Check the installation and insert the tray correctly. Wipe with a dry cloth. Keep the door closed to remove dewdrops. Regulate adjustable feet. Install on level floor. The following points are not malfunctions: Water-flowing sound can be heard when the compressor stops. This is a sound of REFRIGERANT flowing. 5

MANUFACTURING COMPANY ONE YEAR WARRANTY Turbo air warrants to the original purchaser of every new Turbo air refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or workmanship, under normal use and service, for a period of one(1) year from the date of original installation or 15 months after shipment date from Turbo air, whichever occurs first. Any parts covered by this warranty that are examined and determined by Turbo air to have been defective within one (1) year of original installation or fifteen (15) months after shipment date from manufacturer, whichever occurs first, shall be repaired or replaced as stated below. Turbo air shall be deemed to have fully complied with its obligation under the foregoing warranties by electing either one of the following procedures, at the sole discretion of Turbo air. 1. Furnishing a replacement part, freight collect, in even exchange for the returned part, freight collect. 2. Receiving the defective part, freight collect; repairing it; and returning it, freight collect. ADDITIONAL FOUR YEAR COMPRESSOR WARRANTY In addition to the (1) one year warranty stated above, Turbo air warrants its hermetically and semi-hermetically sealed compressor to be free from defects in both material and workmanship under normal use and service for a period of four (4) additional years from the date of original installation but not to exceed five (5) years and three (3) months after shipment from manufacturer. Compressors determined by Turbo air have been defective within this extended time period will, at Turbo air s option, be either repaired or replaced with a compressor or compressor parts of similar design and capacity. The for (4) year extended compressor warranty applies only to hermetically and semi-hermetically sealed parts of the compressor and does not apply to any other parts or components, including, but not limited to, cabinet, paint finish, temperature control, refrigerant, metering device, driers, motor starting equipment, fan assembly any other electrical component, etcetera. 134A COMPRESSOR WARRANTY The four year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to: 1. This system contains R134A refrigerant and polyol ester lubricant. The Polyol ester lubricant has rapid moisture absorbing qualities. If long exposure to the ambient conditions occur, the lubricant must be removed and replaced with new. Listed below are the approved lubricants for the Tecumseh compressors. 1 ICI-Emkarate RL 184 2 Emery-2927-A 3 Mobile Artic 22A Failure to comply with recommended lubricant specification will void the compressor warranty. 2. Dryer replacement is very important and must be changed when a system is opened for servicing. dryer must be used with XH- 9 desiccant. 3. Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower must obtained. 6

WHAT IS NOT COVERED BY THIS WARRANTY Turbo air s sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below. This warranty neither assumes nor authorizes any person to assume obligations other than expressly covered by this warranty. 1. WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered. ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES HEREIN MADE AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 2. NO CONSEQUENTIAL DAMAGES. TURBO AIR IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT LOSS OR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOSSES OR DAMAGES ARISING FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT ON ACCOUNT OF REFRIGERATION FAILURE. 3. ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE, FLOOD, ACTS OF GOD. TURBO AIR is not responsible for the repair or replacement of any parts that Turbo Air determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse, accident, damage during transit or installation, fire, flood, or an Act of God. 4. NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO OTHER WARRANTIES, EXPRESS, IMPLIED OR STATUTORY, EXCEPT THE ONE(1) YEAR WARRANTY AND THE ADDITIONAL FOUR (4) YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE. THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. 5. TRANSPORTATION COSTS. Turbo Air will accept parts covered under this warranty freight collect, provided that shipment has received prior approval. Turbo Air is not responsible for any other transporation costs, but will ship freight collect parts either repaired or replaced under these warranties. 6. WARRANTY CLAIMS. All claims should include: model number of the cooler, the serial number of the cabinet, proof of purchase, date of installation, and all pertinent information supporting the existence of the alleged defect. Any action or breach of these warranty provisions must be commenced within one (1) year after that cause of action has accrued. 1250 Victoria street Carson, CA 90746 U.S.A. & Canada Toll Free 1-800-627-0032 For Service 1-800-381-7770 TEL: 310-900-1000 FAX: 310-900-1077 www.turboairinc.com

Warranty Claims... All claims for parts or labor must be made directly thorough Turbo Air. All claims should include: model number of the unit, the serial number of the cabinet, proof of purchase, date of installation, and all pertinent information supporting the alleged defect. In case of compressor replacement under warranty, either compressor or compressor tag must be returned to Turbo Air along with above listed information. Failure to comply with warranty policies will result in voiding claims. One Year Parts & Labor Warranty... Turbo Air warrants all new refrigerated components, the cabinet and all parts, to be free from defects in materials or workmanship, under normal and proper use and maintenance service as specified by Turbo Air and upon proper installation and start-up in accordance with the instruction packet supplied with each Turbo air unit. Turbo Air s obligation under this warranty is limited to a period of one (1) year from the date of original installation or 15 months after shipment date from Turbo Air, whichever occurs first. Any part, covered under this warranty, that are by Turbo Air to have been defective within one (1) year of original installation or fifteen (15) months after shipment date from manufacturer, whichever occurs first, is limited to the repair or replacement, including labor charges, of defective parts or assemblies. The labor warranty shall include standard straight time labor charges only and reasonable travel time, as determined by Turbo Air. Additional Four Year Compressor Warranty... In addition to the one (1) year warranty stated adove, Turbo Air warrants its hermetically sealed compressor to be free from defects in both material and workmanship under normal and proper use and maintenance service for a period of four (4) additional years from the date of original installation, but not to exceed five (5) years and three(3) months after shipment from the manufacturer. Compressor determined by Turbo Air to have been defective within this extended period will, at Turbo Air s discretion, be either repaired or replaced with a compressor or compressor parts of similar design and capacity. The four(4) year extended compressor warranty applies only to hermetically sealed parts of the compressor and does not apply to any other parts or components, including, but not limited to, cabinet, paint finish, temperature control, refrigerant, metering device, driers, motor starting equipment, fan assembly or and other electrical components, etcetera. 404A / 134a Compressor Warranty... The four-year compressor warranty detailed above will be void if the following procedure is not carefully adhered to: 1. This system contains R404A or R134a refrigerant and polyol ester lubricant. The polyol ester lubricant has rapid moisture absorbing qualities. 2. Drier replacement is very important and must be changed when a system is opened for servicing. A620 copper drier or better is highly recommended. 3. Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower must be obtained. 4. When compressor is grounded, suction drier and 620 drier or better must be replaced. 5. Compressor must be obtained through Turbo Air, unless otherwise specified in writing, through Turbo Air s warranty department. 404A / 134a Compressor Warranty... Turbo Air s sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below. This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty. NO CONSEQUENTIAL DAMAGES. TURBO AIR IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT LOSS; OR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOSSES, OR DAMAGES ARISING FROM FOOD OR PRODUCT SPOILAGE REGARDLESS OF WHETHER OR NOT THEY RESULT FROM REFRIGERATION FAILURE. WARRANTY IS NOT TRANSFERABLE, This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered. ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANNTIES HEREIN AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR LABOR COVERAGE FOR COMPONENT FAILURE OR OTHER THE WARRANTY PACKET PROVIDED WITH THE UNIT. ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE, FOOD, ACTS OF GOD. Turbo Air is not responsible for the repair or replacement of any parts that Turbo Air determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse, accident, damage during transit or installation, fire, flood, or act of GOD. IMPROPER ELECTRICAL CONNECTIONS. TURBO AIR IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM ELECTRICAL POWER FAILURE, THE USE OF EXTENSION CORDS, LOW VOLTAGE, OR VOLTAGE DROPS TO THE UNIT. NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE; THERE ARE NO OTHER WARRANTIES, EXPRESSED, IMPLIED OR STATUTORY, EXCEPT THE ONE (1) YEAR PARTS & LABOR WARRANTY AND THE ADDITIONAL FOUR (4) YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE. THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. Outside U.S.and Canada; This warranty does not apply to, and Turbo Air is not responsible for, any warranty claims made on products sold or used outside the continent of the United States and Canada. CHANGES MADE TO WARRANTY COMMENCED ON 11/01/2007