Second Revision No. 11-NFPA [ Section No. 2.4 ] Submitter Information Verification. Committee Statement

Similar documents
Correlating Committee on Automatic Sprinkler Systems

Public Comment No. 2-NFPA [ Section No ]

MODULE 2. Water-Based Suppression System Basics


Foam Products ENGLISH

SECURITY BLANKET Foam Fire Protection Products

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

TECHNICAL DATA 3% AR-AFFF

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.


A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO AUPCI

Foam Systems U.S. Quick Reference Guide

Public Input No. 2-NFPA [Chapter F]

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

Becoming an Expert on Dry-pipe, Preaction, and Deluge Sprinkler Systems

Aircraft Hangars DESCRIPTION. A single fire area not larger than 40,000 sq. ft. (3,716 sq. m) per hangar construction type as defined by NFPA 409

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

Public Input No. 79-NFPA [ Section No. 1.1 ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Aircraft Hangers. ft. (3,716 sq. m) per hangar construction type as defined by NFPA 409

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

RIM SEAL SYSTEMS E-BOOK

Second Revision No. 36-NFPA [ Detail ] Submitter Information Verification. Committee Statement 5/18/2015 1:01 PM

Inspection of Fire Sprinkler Systems. NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems

The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring)

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

Tel Web: dyayan.com

Technical Article. Foam Systems - Low Expansion, Medium Expansion, High Expansion. Martin Workman, Product Manager Special Hazards Division

A.8.6 Part 6 : Special Fire Extinguishing Systems

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

SECTION COMMERCIAL-KITCHEN HOODS

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Proportioners for Stationary Extinguishing Systems

Design & Construction Standards, Revised January

Foam Products. Quick Reference Guide EMEA. Trusted above all.

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

Second Revision No. 3-NFPA [ Section No. 2.3 ]

TECHNICAL DATA APPROVED SPRINKLERS FOR USE WITH FOAM CONCENTRATES 1. GENERAL DESCRIPTION 2. LISTINGS AND APPROVALS

The Committee updated the edition dates for the reference sources for extracted text within the standard per the NFPA Manual of Style.

Understanding, Applying and Enforcing NFPA 25. James D. Lake NFSA Director of Training

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Australian Standard. Water mist fire protection systems System design, installation and commissioning AS

Second Revision No. 20-NFPA [ Section No. 1.4 ] Supplemental Information. Submitter Information Verification. Committee Statement

NFPA 72 is in the same cycle as NFPA 80. The extracted text will be updated with a Second Revision during the second draft meeting.

SECTION SPRINKLER SYSTEMS

First Revision No. 15-NFPA [ Chapter 2 ]

The development Of the new CEN standard For fire fighting foam systems EN13565 Part 2

Second Revision No. 3 implements the text of Committee Input No. 36 as proposed in the First Draft Report, along with the following amendments:

A HISTORICAL REVIEW OF FLUORINATED FOAM FIREFIGHTING AGENTS, PERFORMANCE REQUIREMENTS/ ENVIRONMENTAL SAFEGUARDS REVIEW

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

The Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

First Revision No. 3-NFPA 51B-2016 [ New Section after 1.5 ] Submitter Information Verification. Committee Statement 11/18/2016 2:25 PM

NFPA 96, 2017 REVIEW SUMMARY

Public Input No. 4-NFPA [ Section No. 4.2 ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ]

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

Committee Input No. 28-NFPA 13R-2013 [ Global Input ]

NFPA Technical Meeting (Tech Session) June 24-25, 2015 Agenda*

FIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES

Changes for the New Edition. Senior Engineer, NFPA NFPA

Committee Input No. 60-NFPA [ Sections , ]

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

NFPA Edition Update

Foam Solutions, LLC Performance Parkway, Columbus, Ohio Ph ; Fax

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

Deluge & Preac tion Systems

"Spray area" is the term that is used throughout the document. This change is for consistency.

Agenda Technical Committee on Initiating Devices for Fire Alarm and Signaling Systems June 24-25, 2013 Saint Louis, MO


Fire Prevention Plan Program

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

SECTION FM-200 FIRE SUPPRESSION SYSTEM

Florida Building Code 2010

SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET

Change all instances of "flame resistant (hypobaric)" to "Limited-Combustible (material)" in all instances in the document.

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

An Overview Of Fluorinated Firefighting Foams: Past, Present & Future Presented by: Jerry Back, JENSEN HUGHES FOAM SYSTEM SYMPOSIUM

M E M O R A N D U M. NFPA Technical Committee on Fire Safety and Emergency Symbols. NFPA 170 Second Draft TC FINAL Ballot Results (F2014)

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

MEMORANDUM. NFPA 51 First Draft Technical Committee FINAL Ballot Results (A2017 Cycle)

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D40 FIRE PROTECTION 02/18

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

Technical Committee on Fluidized Bed Boilers

SPECIFICATION: ARGONITE Engineered Fire Suppression System

NFPA Technical Meeting (Tech Session) June 16, 2016 Agenda*

M E M O R A N D U M. NFPA 1911 Second Draft Technical Committee FINAL Ballot Results (F2016 Cycle)

MEMORANDUM. Technical Committee on Board and Care Facilities. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017)

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Transcription:

Second Revision No. 11-NFPA 16-2014 [ Section No. 2.4 ] 2.4 References for Extracts in Mandatory Sections. NFPA 11, Standard for Low-, Medium-, and High-Expansion Foam, 2010 2015 edition. NFPA 13, Standard for the Installation of Sprinkler Systems, 2010 2013 edition. Submitter Full Name: Sonia Barbosa Organization: [ Not Specified ] Submittal Date: Tue Mar 04 15:31:57 EST 2014 : Update edition dates.

Second Revision No. 1-NFPA 16-2014 [ Section No. 3.3.6 ] 3.3.6* Foam-Water Sprinkler System. A piping network employing automatic sprinklers, nozzles or other discharge devices, connected to a source of foam concentrate and to a water supply. The piping network is equipped with discharge devices, consisting of sprinklers or nozzles, for discharging the extinguishing agent over the area to be protected. The piping is connected to the water supply through a control valve that is commonly actuated by operation of automatic detection equipment installed in the same areas as open discharge devices. When this valve opens, water flows into the piping system, foam concentrate is injected into the water, and the resulting foam solution discharging through the discharge devices generates and distributes foam. Upon exhaustion of the foam concentrate supply, water discharge follows and continues until manually shut off. Existing deluge sprinkler systems that have been converted to the use of aqueous film-forming foam or film-forming fluoroprotein foam are considered foam-water sprinkler systems. 3.3.6.1* Foam-Water Deluge System. A foam-water sprinkler system employing open discharge devices, which are attached to a piping system that is connected to a water supply through a valve that is opened by the operation of a detection system, which is installed in the same areas as the discharge devices. When this valve opens, water flows into the piping system and discharges from all discharge devices attached thereto. 3.3.6.2* Foam-Water Dry Pipe System. A foam-water sprinkler system employing automatic sprinklers or nozzles that are attached to a piping system that contains air or nitrogen under pressure, the release of which (as from the opening of a sprinkler) permits the water pressure to open a valve known as a dry pipe valve. The water then flows into the piping system and out the opened sprinklers. 3.3.6.3* Foam-Water Preaction System. A foam-water sprinkler system employing automatic sprinklers or nozzles attached to a piping system containing air that might or might not be under pressure, with a supplemental detection system installed in the same area as the sprinklers. Actuation of the detection system opens a valve that permits water to flow into the sprinkler piping system and to be discharged from any sprinklers that have activated. 3.3.6.4* Foam-Water Spray System. A foam-water sprinkler system designed to use nozzles rather than sprinklers. 3.3.6.5* Preprimed System. A wet pipe system containing foam solution. Submittal Date: Tue Mar 04 11:17:14 EST 2014 The sentences proposed to be deleted in the definitions are not part of the definition but are an explanation which should be placed either in the annex (as recommended in public comments # 3 through 6) or in a separate part of the standard. Definitions are not enforceable and requirements or additional information should be placed out side the definitions area.a list of discharge devices was added to the revised single sentence definition.

Public Comment No. 2-NFPA 16-2013 [Section No. 3.3.6]

Second Revision No. 13-NFPA 16-2014 [ Sections 3.3.7.2, 3.3.7.3 ] 3.3.7.2* Aqueous Film-Forming Foam Concentrate (AFFF). A concentrate based on fluorinated surfactants plus foam stabilizers to produce a fluid aqueous film for suppressing hydrocarbon fuel vapors and usually diluted with water to a 1 percent, 3 percent, or 6 percent solution. [11,2010 2015 ] 3.3.7.3* Film-Forming Fluoroprotein Foam Concentrate (FFFP). A protein-foam concentrate that uses fluorinated surfactants to produce a fluid aqueous film for suppressing hydrocarbon fuel vapors. [11,2010 2015 ] Submitter Full Name: Sonia Barbosa Organization: [ Not Specified ] Submittal Date: Wed Mar 05 11:44:52 EST 2014 : Update extract text

Second Revision No. 4-NFPA 16-2014 [ Section No. 5.11.2 ] 5.11.2 Unless required by other standards or product listings, strainers shall be required only where there are discharge orifices that are 3 8 in. (10 mm) or smaller. Submittal Date: Tue Mar 04 11:49:54 EST 2014 This section was addressing the protection of the concentrate pump. In reviewing this section, the TC realized the pump is not within the scope of this TC, therefore this section is being deleted. Public Comment No. 8-NFPA 16-2013 [Section No. 5.11.2]

Second Revision No. 2-NFPA 16-2014 [ Section No. A.3.3.6 ] A.3.3.6 Foam-Water Sprinkler System. The piping network is equipped with discharge devices, consisting of sprinklers or nozzles, for discharging the extinguishing agent over the area to be protected. The piping is connected to the water supply through a control valve that is commonly actuated by operation of automatic detection equipment installed in the same areas as open discharge devices. When this valve opens, water flows into the piping system, foam concentrate is injected into the water, and the resulting foam solution discharging through the discharge devices generates and distributes foam. Upon exhaustion of the foam concentrate supply, water discharge follows and continues until manually shut off. Existing deluge sprinkler systems that have been converted to the use of aqueous film-forming foam or film-forming fluoroprotein foam are considered foam-water sprinkler systems. These systems can be preprimed with foam solution. This solution would remain in the piping until the system is called upon to operate. Preprimed systems could require draining, flushing, and repriming on a periodic basis (see Section 9.3). This procedure will require an investment in both time and material and should be programmed into the total system operating cost. Submittal Date: Tue Mar 04 11:44:40 EST 2014 The sentences proposed to be deleted from the definitions in public comment # 2 are not part of the definition but are an explanation which should be placed either in the annex (as recommended in public comment # 3) or in a separate part of the standard. Definitions are not enforceable and requirements or additional information should be placed out side the definitions area. This comment is being submitted on behalf of the Glossary on Terminology. Public Comment No. 3-NFPA 16-2013 [Section No. A.3.3.6]

Second Revision No. 5-NFPA 16-2014 [ Section No. A.3.3.6.1 ] A.3.3.6.1 Foam-Water Deluge System. Foam-water sprinklers are open-type sprinklers designed to do the following: (1) Receive foam solution (water plus liquid concentrate) (2) Direct the solution through an integral foam maker, the nozzle action of which breaks the solution into spray and discharges it into a mixing tube, where it combines with air drawn in through openings in the housing (3) Provide mixing chamber capacity for development of the air foam (4) Direct the formed foam discharging from the open end of the mixing tube against a deflector, shaped to distribute the foam in a pattern essentially comparable to the water distribution pattern of present-day standard sprinklers (nomenclature from NFPA 13, Standard for the Installation of Sprinkler Systems ) and to do so with essentially no impingement of the foam on the ceiling (5) Develop a water distribution pattern directly comparable to that of standard sprinklers, in the case of discharge of water only (i.e., in the absence of foam) The normal direction of discharge from foam-water sprinklers is downward. To provide a choice in installation design, foam-water sprinklers are produced for installation in the upright position and in the pendent position with the pattern of discharge in either case in the downward direction. Sprinkler deflectors are formed to produce the required discharge pattern, which could mean differing shapes of deflectors for each of the two positions of installation. The variation in the shape of deflectors is illustrated in Figure A.3.3.6.1. When the valve in a foam-water deluge system opens, water flows into the piping system and discharges from all discharge devices attached thereto. Figure A.3.3.6.1 Variations in Deflector Shape.

Submittal Date: Tue Mar 04 12:00:14 EST 2014 The sentences proposed to be deleted from the definitions in public comment # 2 are not part of the definition but are an explanation which should be placed either in the annex (as recommended in public comment # 4) or in a separate part of the standard. Definitions are not enforceable and requirements or additional information should be placed out side the definitions area. This comment is being submitted on behalf of the Glossary on Terminology. Public Comment No. 4-NFPA 16-2013 [Section No. A.3.3.6.1]

Second Revision No. 6-NFPA 16-2014 [ Section No. A.3.3.6.2 ] A.3.3.6.2 Foam-Water Dry Pipe System. After the valve is opened, the water then flows into the piping system and out the opened sprinklers. Dry pipe systems are inherently slower in operation and have a tendency to develop internal scale. Since the foam solution would be proportioned into the system upon operation, the first discharge would be an effective foam. However, due to the slower operation, this should be considered the least desirable type of sprinkler system for closed-head foam-water sprinkler application. Submittal Date: Tue Mar 04 12:00:42 EST 2014 The sentences proposed to be deleted from the definitions in public comment # 2 are not part of the definition but are an explanation which should be placed either in the annex (as recommended in public comment # 5) or in a separate part of the standard. Definitions are not enforceable and requirements or additional information should be placed out side the definitions area. This comment is being submitted on behalf of the Glossary on Terminology. Public Comment No. 5-NFPA 16-2013 [Section No. A.3.3.6.2]

0 Second Revision No. 7-NFPA 16-2014 [ Section No. A.3.3.6.3 ] A.3.3.6.3 Foam-Water Preaction System. Actuation of the detection system opens a valve that permits water to flow into the sprinkler piping system and to be discharged from any sprinklers that have activated. These systems combine the features of both wet pipe and dry pipe systems. The piping is empty and might or might not contain air under low pressure for supervision of the piping. There is a separate detection system that operates the water control valve to release foam solution into the piping. (The actuating means of the valve is described in NFPA 13, Standard for the Installation of Sprinkler Systems.) This detection system should be more sensitive than the sprinkler elements. With this arrangement, foam solution is usually released into the piping before the sprinklers operate so that, when they do, there is an immediate discharge, as with a wet pipe system. To ensure this discharge, supervision of the actuation system is recommended. Foam solution would be proportioned into the system upon operation, so there is no need for prepriming. Overall response time generally approaches that of a wet pipe system. Actual time of foam discharge would depend on the type of separate detection system used and the type of fire. With a rapidly developing fire, the sprinklers might begin to operate very close to the initial operation of the separate detection system, and the piping might not have time to fill with foam solution to achieve immediate discharge. With a slowly developing fire, there would be sufficient time to fill the piping, and there would be a discharge of fresh foam upon sprinkler operation. These systems are more complex than dry pipe and wet pipe systems, and this factor should be considered. Submittal Date: Tue Mar 04 12:00:54 EST 2014 The sentences proposed to be deleted from the definitions in public comment # 2 are not part of the definition but are an explanation which should be placed either in the annex (as recommended in public comment # 6) or in a separate part of the standard. Definitions are not enforceable and requirements or additional information should be placed out side the definitions area. This comment is being submitted on behalf of the Glossary on Terminology. Public Comment No. 6-NFPA 16-2013 [Section No. A.3.3.6.3]

1 Second Revision No. 12-NFPA 16-2014 [ Section No. C.3 ] C.3 References for Extracts in Informational Sections. NFPA 11, Standard for Low-, Medium-, and High-Expansion Foam, 2010 2015 edition. NFPA 13, Standard for the Installation of Sprinkler Systems, 2010 2013 edition. Submitter Full Name: Sonia Barbosa Organization: [ Not Specified ] Submittal Date: Tue Mar 04 15:33:30 EST 2014 : Update edition dates.