FE1 Explosion-Proof Electric Air Heaters

Similar documents
FX5 Series Explosion-Proof Electric Air Heaters

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

CR1 Series Triton Corrosion Resistant Washdown Heaters

Owner s Manual. FX4 Series. Electric Forced Air Heaters for Hazardous Locations

FE2 Series. Installation, Operation, & Maintenance Instructions. Electric Forced Air Heaters for Hazardous Locations. Model Coding

Brasch Hazardous Location Unit Heaters

Owner s Manual. Electric Forced Air Heaters for Hazardous Locations. This manual covers the installation, maintenance, repair and replacement parts.

ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S

FX5 SD Series Electric Forced Air Heaters for Hazardous Locations

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

EXH Series Explosionproof Electric Air Heaters

Ultra-Safe EXP Unit Heater

CX1 ProVector Explosion-Proof Heaters

CF1 ProVector Explosion-Proof Heaters

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts.

Description. Applications

XEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

Comfort. Description. Applications

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters


ULTRA-SAFE Explosion-proof Duct Heaters

Explosion-Proof Forced Air Unit Heater - XGB

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Explosion-Proof Forced Air Unit Heater - XGB

Description. Applications

ULTRA-SAFE Explosion-proof Duct Heaters

HLA Series Hazardous Location Fan Forced Unit Heater Data Sheet

HLA Series Hazardous Location Fan Forced Unit Heater

HLA Series Hazardous Location Fan Forced Unit Heater

Electric Unit Heaters for Standard and Hazardous (Classified) Locations


products 22 º C Ventilation Air Conditioning Refrigeration Unit heaters Inside PROVIDED BY HEINEN & HOPMAN

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

TABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater

INSTALLATION, PARTS, SERVICE AND MAINTENANCE MANUAL HEX5 series, electric unit heaters for hazardous locations

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

Electric Unit Heaters

Type UB-2502A and UB-3002A Forced-Air Heater

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Electric Unit Heaters for Standard and Hazardous (Classified) Locations

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

ELECTRIC UNIT HEATERS FOR STANDARD AND HAZARDOUS (CLASSIFIED) LOCATIONS

CF1 ProVector Series. Installation, Operation, & Maintenance Instructions. Electric Convection Air Heaters for Hazardous Locations

MAC N-407 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

Centro-Matic Automated Lubrication Systems System Controls

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

Shipboard Electric Water Heater

Shipboard Electric Water Heater

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

CXH-A Forced-Air Heater

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Explosion-proof Immersion Heater Type D-8660

RGE 13 A T - 1 A

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

( )

(770) wwww.southgateprocess.com

Description. Construction

KUH. Horizontal Unit Heater. Applications. Description

Shipboard Electric Water Heater

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters Selection Guidelines

Commercial High-Efficiency Condensing Units

Tubular Industrial Process

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

MAC-120HE-03 Air-Cooled Chiller

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Air-Cooled Global Chiller

Custom Duct Heaters. Special Applications

INSTALLATION, PARTS, SERVICE & MAINTENANCE MANUAL FOR HLA SERIES HEATER

Q-TEC QC-Series Chilled Water Air Conditioner

TECHNICAL SPECIFICATIONS

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

TABLE OF CONTENTS page 2

Flanged Immersion Heaters

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

Product Data. ama. Model BW9 Gas-Fired Condensing Water Boiler Series A FEATURES

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Flanged Immersion Heaters

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Transcription:

Explosion-Proof Electric Air Heaters The heater core assembly is contained in a sturdy, epoxy-coated, 14-gauge steel cabinet which also carries the motor and fan assembly. Adjustable louvers allow directional control of the airflow. A narrow gap, twopiece fan guard is provided to shield all moving parts. All fasteners are zinc plated for corrosion protection. All aspects and details of the are subjected to exhaustive technical analysis and testing during design and development, and are manufactured under a registered quality assurance program. As a result, they have consistently proven their safety and reliability. heaters are CE Marked & ATEX Approved to Directive 94/9/EC for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries, petrochemical plants, pulp and paper mills, hazardous waste storage facilities, wastewater treatment plants, etc., where specific explosive gases or dusts maybe present. All heaters utilize the VacuCore liquid-to-air heat exchanger. The induced vacuum within the sealed core provides greater efficiency, even distribution of heat across the face of the exchanger, and a faster warmup. When necessary, the entire core can be safely and easily replaced with a new or factory reconditioned exchange unit. POCC CA. ГБ06.B00914 Model Coding - 2 1 50-126 - T Model Series 1st Generation Heater Voltage 2V 230V 240V 380V 400V 415V 440V 480V 600V Phase 1 3 Hertz 50 60 Heater KilowattS Options T - Built-in thermostat Reminder: This nomenclature illustration is intended primarily to explain how a product part number is defined. Not all voltage and/or wattage combinations are available - please consult the Performance Data chart(s) for product availability.

General Specifications Approvals Hazardous Location Classifications Enclosures Motor Type Fan Fan Guard Mounting Holes Heating Elements Temperature High-Limit Control Circuit Optional Built-in Thermostat Control Transformer Contactor Heat Transfer Fluid Cabinet Material Core Conduit Material Overpressure Protection Operational Temperature Limitations Storage Limitations ATEX Approved (Directive 94/9/EC), GosStandart Certificate of Conformity (GOST) ITS07ATEXQ5657 II 2 G, Ex d IIB T3 Zone 1 NEMA Type 7 & 9. For indoor use only. Do not immerse in water. Do not store or use in areas exposed to rain or snow Explosion-proof. Thermally protected. Permanently lubricated ball bearings Aluminum blades with steel spider and hub, 0.625 (16 mm) bore Split design with close wire spacing. 0.248 (6 mm) diameter probe will not enter Two 0.563 (14 mm) diameter holes at top of heater Three long-life, low watt-density, high grade metal-sheathed elements Automatic reset type, snap-action bimetal, open on temperature rise. Rated 0,000 cycles at amps 1V, 0.128 amps, 15VA. (Grounded) Flame-proof. 2 C to 28 C (36 F to 82 F) Multiple primary, 1V secondary, 25VA 40 or 75 amp. Rated for 500,000 mechanical operations. 1V, 15VA coil (separately fuse-protected) Long-life formulated PROPYLENE glycol and water, freeze protected to -45 C (-49 F) 14-gauge (2 mm) Steel. Epoxy coated with five-stage pretreatment, including iron phosphate. Optional Heresite coating available for corrosive atmospheres Core Steel with integral aluminum fins, vacuum charged and sealed. Optional Heresite coating available for corrosive atmospheres Heavy wall, 0.122 (3 mm) steel Preset 690 kpa (0 psig) pressure relief valve, aluminum body, no serviceable parts - C to 40 C (-4 F to 4 F) -45 C to 80 C (-49 F to 176 F), short term to 150 C (302 F) maximum 16 hours continuous. Do not immerse in water. Do not store in areas exposed to rain or snow

Performance Data for 60 Hertz ITS07ATEXQ5657 II 2 G, Ex d IIB T3 Zone 1 1. To order a heater with a built-in room thermostat, add a T suffix to model number. 2. Heater is functioning normally if at rated voltage the amp draw is within % of the value in this table.

Performance Data for 50 Hertz ITS07ATEXQ5657 II 2 G, EEx d IIB T3 Zone 1 1. To order a heater with a built-in room thermostat, add a T suffix to model number. 2. Heater is functioning normally if at rated voltage the amp draw is within % of the value in this table.

Specifications for 60 Hertz 60 HERTZ NOMINAL kw 2.5 to 3.7 to 5.0 6.3 to 7.5 8.4 to 12.5 to 13.9 14.9 to.9 to 21 22.4 to 23.1 Maximum Altitude (ft) 12,000 8,000,000 7,000,000 7,000,000 7,000 3,658 2,438 3,048 2,134 3,048 2,134 3,048 2,134 Air Delivery @21ºC (m 3 /hr) 850 1,444 2,973 6,116 @70ºF (CFM) 500 850 1,750 3,600 Horizontal Throw (ft) 15 4.6 30 9.1 40 12.2 70 21.3 Maximum Mounting Height (ft) 7 (to underside) 2.1 6.1 Motor Speed (RPM) Fan Diameter Net Weight (in) (mm) 12 305 131 16 406 153 508 192 59.5 69.5 87.3 Shipping Weight 180 81.8 2 91.8 241 9.5 Weights are an approximate maximum. 50 HERTZ NOMINAL kw 2.5 to 3.7 to 5.0 6.3 to 7.5 8.4 to 12.5 to 13.9 14.9 to.9 to 21 22.4 to 23.1 Maximum Altitude (ft) 12,000 8,000,000 7,000,000 7,000,000 7,000 3,658 2,438 3,048 2,134 3,048 2,134 3,048 2,134 Air Delivery @21ºC (m 3 /hr) 679 1,189 2,463 5,096 @70ºF (CFM) 400 700 1,450 3,000 Horizontal Throw (ft) 13 4.0 25 7.6 35.7 60 18.2 Maximum Mounting Height (ft) 7 (to underside) 2.1 6.1 Motor Speed (RPM) 1,425 1,425 1,425 Fan Diameter Net Weight (in) (mm) 12 16 Shipping Weight Weights are an approximate maximum. Specifications for 50 Hertz 305 131 59.5 180 81.8 406 153 69.5 2 91.8 508 192 87.3 241 9.5 1. Minimum conductor size for 30 C (86 F) ambient. Derate conductor for ambient temperature. Use minimum 90 C (194 F) insulation. 2. Operation at lower voltage will result in reduced heat output and amp draw. 3. Add T to model number when adding a built-in thermostat. Installation Conditions: 1. The Series Electric Air Heaters are for dry indoor use only. Do not immerse in water. Do not store or use in areas exposed to rain or snow. 2. The heaters are to be used only in atmospheres having an ignition temperature higher than Temperature Code T3 0 C (329 F) for Class I & II. 3. Altitude restrictions apply - see specifications above. 4. Heaters should be connected to a fixed power supply and must be permanently mounted in a level, upright position during operation. 5. Read and be aware of the terms of our Warranty located in the owner s manual. 6. Refer to Owner s Manual.