Vertical Air-Cooled Split-System Cooling Units Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 50VZ (40PZ/38VZ) Nominal cooling capacity 14.6-74.4 kw The 50VZ air-cooled split-system cooling units are ideal for installation in new buildings or refurbishment projects in existing buildings. They are designed for small and medium-sized air conditioning systems for commercial and residential applications, such as restaurants, shops, laboratories, art galleries, offices and homes. The units consist of two sections: an evaporator section (40PZ) and a condenser section (38VZ) of matching size. Features The cabinet is made of prepainted metal sheets. The panels are thermally and acoustically insulated. All moving components incorporate internal and external shock absorbers. The evaporator and condenser sections incorporate double inlet centrifugal fans, with forward-curved blades, driven by three-phase motors with adjustable belt-pulley, adequately dimensioned and easily adjusted. Refrigerant-to-air heat exchangers are manufactured from high quality, deoxidized and dehydrated copper tubing, mechanically expanded into precoated aluminium fins. Hermetic, reciprocating or scroll, three-phase compressors for use with refrigerant R-407C (depending on model). A thermal protection device in the windings protects the motor from overcurrent and excessive temperatures. Built-in overpressure valves protect the compressor against high discharge pressure. The motors are force-lubricated, cooled by suction gas and can operate in high ambient temperatures. Internal mufflers and mounting on shock absorbers guarantee exceptionally quiet compressor operation. All components are designed to work in a wide range of compression ratios and temperatures. The refrigerant circuit is made of deoxidized and dehydrated copper tubing and soldered with a silver alloy rod. Completely hermetic and leak tested, it incorporates access and service valves and a stainless steel mesh filter at the capillary inlet which prevents obstruction by foreign matter. The control box includes an electronic control system to operate the unit and improve performance. This control also simplifies and facilitates service operations.
Master Link II The control system is made up of a main board. This electronic board is standard for all units. It can display eight digital inputs and six analogue inputs. The board functions are: - Management of the application program - Supervision of internal communications - Control of the rest of the system elements - Communication with the service network - Display of the analogue and digital input - Management of the output relays - Signalling of the alarm codes - Selection of optional functions The board includes a number of warning LEDs that give information about the system and unit operation. The LED status enables service and maintenance operations. Options and accessories Option Accessory Head pressure control kit x x Electric heating x x Crankcase heater x x Hot water coil x x Economizer x Outdoor air filter x x User interface x Protection grille x x Minimum opening potentiometer x x Volt-free contacts x Optional communications x x Return air sensor x x drive x 38VZ for vertical discharge x Physical data Operating limits Zone Air temperature C Dry bulb Indoor Maximum 35 21 Minimum 19 14 Outdoor Maximum 46 - Minimum 19* - Wet bulb * With optional head pressure control the unit will operate at temperatures below 19 C. 50VZ (40PZ/38VZ) 015 025 030 031 040 045 055 065 075 Nom. cooling capacity* kw 14.60 22.74 29.75 27.80 35.05 45.21 53.90 63.89 74.35 Unit weight kg 50VZ 230 390 402 410 618 842 894 943 1033 40PZ 78 140 150 150 230 297 317 335 365 38VZ 152 250 252 260 388 545 577 608 668 Compressor Hermetic reciprocating Scroll Oil charge l 1.8 3.9 3.9 1.8 x 2 4 x 2 4 x 2 4 x 2 4 x 2 6.6 x 2 Oil type Maneurop 160PZ Mobil EAL Arctic 22CC Maneurop 160SZ Refrigerant R-407C Refrigerant charge** kg 3.80 6.62 7.43 3.80 x 2 4.70 x 2 6.70 x 2 8.80 x 2 9.40 x 2 11.00 x 2 Evaporator section (40PZ) Copper tubes, aluminium fins Face area m 2 0.34 0.64 0.69 0.69 0.84 1.10 1.10 1.34 1.34 Rows...fins/m 3...551 4...472 4...472 4...472 4...472 4...551 6...472 6...551 6...551 Test pressure bar 30 30 30 30 30 30 30 30 30 Condenser section (38VZ) Copper tubes, aluminium fins Face area m 2 0.49 0.87 0.87 0.87 1.19 1.73 1.73 2.12 2.12 Rows...fins/m 5...551 4...551 5...551 5...551 5...551 5...551 6...551 6 551 6...551 Test pressure bar 30 30 30 30 30 30 30 30 30 Evaporator fan (40PZ) Double inlet centrifugal type Quantity 1 2 2 2 2 2 2 2 2 Nominal air flow l/s 960 1490 1690 1690 2190 2640 2910 3140 3530 Air flow range l/s 768-1152 1192-1788 1352-2028 1352-2028 1752-2628 2112-3168 2328-3492 2512-3768 2824-4236 Nominal static pressure (dry/ wet) Pa 90/70 90/70 120/100 120/100 140/120 170/150 180/160 200/180 210/180 Condenser fan (38VZ) Double inlet centrifugal type Quantity 1 2 2 2 2 2 2 2 2 Nominal air flow l/s 1470 3020 2780 2780 3610 4580 5080 6030 6890 Air flow range l/s 1176-1764 2416-3624 2224-3336 2224-3336 2888-4332 3664-5496 4064-6096 4824-7236 5512-8268 Nominal static pressure Pa 50 50 60 60 60 75 100 100 100 Air filter Filter class M1 Quantity 1 2 2 2 2 3 3 3 3 Width x height mm 800x443 596x540 596x590 596x590 716x590 676x587 616x587 749x587 749x587 Thickness mm 15 15 15 15 15 15 15 15 15 Condensing unit 38VZ*** 015 025 030 031 040 045 055 065 075 Nom. cooling capacity kw 13.47 19.97 27.02 24.80 32.54 40.30 48.21 59.13 71.10 * Based on an outdoor air temperature of 35 C db and an indoor air temperature of 19 C wb ** The refrigerant charge given is for the complete system, but excludes the connection lines. *** Based on an outdoor air dry bulb temperature of 35 C and a dew point suction temperature of 7 C.
Electrical data 50VZ (40PZ/38VZ) 015 025 030 031 040 045 055 065 075 Nominal voltage ±10%* V 230 400 230 400 230 400 230 400 230 400 230 400 230 400 230 400 230 400 Nominal power input** kw 7.3 7.3 11.1 11.1 14.0 14.0 14.6 14.6 18.1 18.1 21.4 21.4 25.4 25.4 30.0 30.0 37.6 37.6 Nominal current drawn** A 23.8 13.8 33.1 19.1 39.4 22.8 44.9 26.0 52.6 30.4 64.9 37.5 74.3 43.0 87.8 50.8 122.1 67.1 Effective power input kw 6.8 6.8 10.2 10.2 13.0 13.0 13.6 13.6 16.8 16.8 19.0 19.0 22.2 22.2 26.1 26.1 33.1 33.1 Effective current drawn A 21.6 12.5 30.5 17.6 37.0 21.4 41.9 24.2 56.5 32.6 57.9 33.4 70.0 40.5 76.6 44.3 102.0 59.0 Starting current A 139.5 80.0 174.1 106.3 219.0 133.3 165.9 95.3 235.2 134.0 278.4 156.7 329.1 187.8 384.5 219.0 450.1 256.0 Maximum power input*** kw 7.9 7.9 12.2 12.2 15.5 15.5 16.1 16.1 21.8 21.8 25.2 25.2 29.6 29.6 35.0 35.0 44.2 44.2 Maximum current drawn*** A 24.2 14.0 35.5 20.5 43.2 25.0 49.5 28.6 66.6 38.5 73.1 42.2 88.8 51.3 99.7 57.6 129.5 74.8 Condensing unit 38VZ 015 025 030 031 040 045 055 065 075 Nominal voltage ±10%* V 230 400 230 400 230 400 230 400 230 400 230 400 230 400 230 400 230 400 Nominal power input+ kw 6.5 6.5 10.1 10.1 12.8 12.8 13.2 13.2 16.7 16.7 19.4 19.4 23.0 23.0 26.9 26.9 34.7 34.7 Nominal current drawn+ A 20.6 11.9 29.9 17.3 36.6 21.2 37.8 21.9 56.2 32.5 59.4 34.3 72.7 42.0 79.1 45.7 106.6 61.6 Effective power input kw 6.3 6.3 9.6 9.6 12.3 12.3 12.7 12.7 16.0 16.0 18.3 18.3 21.4 21.4 25.0 25.0 32.5 32.5 Effective current drawn A 20.1 11.6 28.5 16.5 35.4 20.4 36.4 21.1 54.0 31.2 56.0 32.4 67.6 39.1 73.5 42.5 99.9 57.7 Starting current A 136.7 78.4 170.1 104.0 214.1 130.5 161.1 92.5 226.9 129.2 270.9 151.2 317.2 180.9 372.2 211.9 434.2 246.8 Maximum power input++ kw 7.7 7.7 11.5 11.5 14.9 14.9 15.3 15.3 20.6 20.6 24.0 24.0 29.1 29.1 33.8 33.8 43.9 43.9 Maximum current drawn++ A 23.5 13.6 33.5 19.4 41.4 23.9 42.5 24.5 62.9 36.4 69.4 40.1 87.4 50.5 96.2 55.6 128.5 74.3 * All units are built for 3-phase, 50 Hz supply. ** Based on an outdoor air dry bulb temperature of 35 C and an indoor air wet bulb temperature of 19 C. *** Based on an outdoor air dry bulb temperature of 46 C and an indoor air wet bulb temperature of 21 C. + Based on an outdoor air dry bulb temperature of 35 C and a dew point suction temperature of 7 C. ++ Based on an outdoor air dry bulb temperature of 46 C and a dew point suction temperature of 12 C. Effective power input is in accordance with Eurovent.
Dimensions, mm 50VZ 015 Optional discharge Power connection 38VZ 015 Drain 3/4" gas 40PZ 015 Drain
Dimensions, mm 50VZ 025 Optional discharge Power connection 38VZ 025 Drain 3/4" gas 40PZ 025 Drain
Dimensions, mm 50VZ 030 Optional discharge Power connection 38VZ 030 Drain 3/4" gas 40PZ 030 Drain
Dimensions, mm 50VZ 031 Optional discharge Power connection 38VZ 031 Drain 3/4" gas 40PZ 031 Drain
Dimensions, mm 50VZ 040 Optional discharge Power connection 38VZ 040 Drain 3/4" gas 40PZ 040 Drain
Dimensions, mm 50VZ 045-055 Optional discharge Power connection 38VZ 045-055 Drain 3/4" gas 40PZ 045-055 Drain
Dimensions, mm 50VZ 065-075 Optional discharge Power connection 38VZ 065-075 Drain 3/4" gas 40PZ 065-075 Drain
50VZ Clearances, mm 38VZ 40PZ * Service space behind the unit depends on whether or not the unit is installed with outdoor air ducts. It is also necessary to leave space for cleaning and inspection of the outdoor heat exchanger. ** Space for removal of the air filter and the indoor or outdoor section belt and pulley is required on the right and left-hand side.
Cooling capacities, kw 50VZ 015 (38VZ 015+40PZ 015) - air flow 960 l/s Ewb Edb Outdoor air temperature C 25 30 35 40 46 15 CAP 14.50 13.64 12.68 11.76 10.61 kw 4.49 4.75 5.00 5.26 5.56 19 SHC 8.35 7.97 7.49 6.91 6.24 21 SHC 10.23 9.84 9.36 8.79 8.16 23 SHC 12.15 11.76 11.28 10.71 10.04 25 SHC 14.02 13.60 12.58 11.72 10.56 17 CAP 15.46 14.50 13.64 12.68 11.57 kw 4.63 4.88 5.14 5.39 5.70 21 SHC 8.45 8.07 7.59 7.01 6.34 23 SHC 10.32 9.94 9.46 8.88 8.26 25 SHC 12.24 11.86 11.38 10.80 10.13 27 SHC 14.12 13.73 13.25 12.68 11.52 19 CAP 16.42 15.56 14.60 13.64 12.48 kw 4.76 5.01 5.27 5.52 5.84 23 SHC 8.55 8.16 7.68 7.11 6.43 25 SHC 10.42 10.04 9.55 8.98 8.35 27 SHC 12.34 11.96 11.48 10.90 10.23 29 SHC 14.21 13.83 13.35 12.77 12.15 21 CAP 17.48 16.61 15.65 14.79 13.73 kw 4.79 5.06 5.34 5.62 5.95 25 SHC 8.64 8.26 7.78 7.20 6.53 27 SHC 10.52 10.13 9.65 9.07 8.45 29 SHC 12.44 12.05 11.57 11.00 10.32 31 SHC 14.31 13.92 13.44 12.87 12.24 50VZ 030 (38VZ 030+40PZ 030) - air flow 1690 l/s Ewb Edb Outdoor air temperature C 25 30 35 40 46 15 CAP 29.46 27.77 25.95 24.56 22.09 kw 8.56 9.18 9.81 10.44 11.14 19 SHC 18.70 17.40 15.86 14.43 12.75 21 SHC 22.39 20.95 19.57 18.04 16.36 23 SHC 25.95 24.56 23.08 21.70 19.97 25 SHC 29.36 27.68 25.90 24.46 21.99 17 CAP 31.33 29.55 27.77 26.04 23.87 kw 8.83 9.46 10.08 10.71 11.40 21 SHC 18.78 17.45 15.96 14.53 12.85 23 SHC 22.49 21.05 19.62 18.14 16.41 25 SHC 26.04 24.66 23.18 22.09 20.07 27 SHC 29.65 27.68 26.84 25.35 23.62 19 CAP 33.26 31.43 29.75 27.97 25.80 kw 9.10 9.73 10.36 10.98 11.75 23 SHC 18.88 17.54 16.31 14.63 12.95 25 SHC 22.59 21.15 19.72 18.24 16.51 27 SHC 26.14 24.76 23.28 21.84 20.16 29 SHC 29.75 27.87 26.93 25.45 23.72 21 CAP 34.74 33.36 31.63 29.95 27.77 kw 9.35 10.03 10.71 11.39 12.21 25 SHC 19.37 17.59 16.21 14.73 13.05 27 SHC 22.68 21.25 19.82 18.34 16.61 29 SHC 26.24 24.86 23.38 21.89 20.21 31 SHC 29.85 28.32 26.98 25.50 23.82 50VZ 040 (38VZ 040+40PZ 040) - air flow 2190 l/s Ewb Edb Outdoor air temperature C 25 30 35 40 46 15 CAP 35.00 33.22 31.21 29.02 26.56 kw 10.24 11.58 12.92 14.29 16.16 19 SHC 20.63 19.67 18.89 18.07 17.11 21 SHC 25.10 24.23 23.41 22.54 21.63 23 SHC 29.57 28.75 27.88 27.06 26.10 25 SHC 34.09 33.13 31.12 28.93 26.47 17 CAP 36.78 35.10 33.13 31.12 28.75 kw 10.47 11.80 13.14 14.49 16.38 21 SHC 20.67 19.85 18.98 18.16 17.20 23 SHC 25.19 24.32 23.50 22.63 21.72 25 SHC 29.66 28.84 27.97 27.11 26.19 27 SHC 34.18 33.31 32.49 31.03 28.66 19 CAP 38.49 36.87 35.05 32.90 30.53 kw 10.68 12.03 13.37 14.71 16.60 23 SHC 20.76 19.94 19.17 18.25 17.30 25 SHC 25.28 23.82 23.55 22.73 21.77 27 SHC 29.75 28.89 28.07 27.20 26.29 29 SHC 34.27 33.40 32.54 31.72 30.44 21 CAP 40.11 38.56 36.64 34.59 32.22 kw 10.90 12.25 13.59 14.94 16.80 25 SHC 20.85 19.99 19.17 18.30 17.34 27 SHC 25.33 24.51 23.64 22.82 21.86 29 SHC 30.12 28.98 28.11 27.38 26.38 31 SHC 34.32 33.50 32.63 31.81 30.85 50VZ 025 (38VZ 025+40PZ 025) - air flow 1490 l/s Ewb Edb Outdoor air temperature C 25 30 35 40 46 15 CAP 23.02 21.61 19.92 18.33 16.68 kw 6.35 6.80 7.25 7.69 8.20 19 SHC 14.00 13.34 12.73 12.08 11.23 21 SHC 16.77 16.12 15.51 14.85 14.00 23 SHC 19.55 18.89 18.23 17.62 16.12 25 SHC 22.32 21.38 19.74 18.23 16.59 17 CAP 24.43 22.93 21.29 19.74 18.04 kw 6.61 7.06 7.51 7.96 8.47 21 SHC 14.28 13.63 13.02 12.36 11.51 23 SHC 17.06 16.40 15.74 15.13 14.28 25 SHC 19.83 19.27 18.51 18.33 17.06 27 SHC 22.60 21.93 21.10 19.55 17.95 19 CAP 25.80 24.34 22.74 21.10 19.45 kw 6.88 7.33 7.77 8.22 8.75 23 SHC 14.57 13.91 13.25 12.64 11.79 25 SHC 17.34 16.68 16.02 15.41 14.57 27 SHC 20.11 19.45 18.80 18.14 17.34 29 SHC 22.86 22.23 21.57 20.91 19.27 21 CAP 27.02 25.61 23.96 21.94 20.82 kw 6.94 7.43 7.92 8.41 9.00 25 SHC 14.85 14.19 13.53 12.92 12.08 27 SHC 17.62 16.96 16.31 15.65 14.85 29 SHC 20.39 19.74 19.08 18.42 17.62 31 SHC 23.12 22.49 21.85 21.19 20.39 50VZ 031 (38VZ 031+40PZ 031) - air flow 1690 l/s Ewb Edb Outdoor air temperature C 25 30 35 40 46 15 CAP 27.34 25.96 24.21 22.23 20.25 kw 9.12 9.90 10.67 11.45 12.38 19 SHC 17.68 16.34 14.96 13.62 12.01 21 SHC 21.08 19.70 18.37 16.98 15.37 23 SHC 24.49 23.11 21.73 20.39 18.78 25 SHC 27.25 25.87 24.12 22.19 20.16 17 CAP 28.95 27.62 26.14 24.30 22.23 kw 9.33 10.07 10.82 11.59 12.52 21 SHC 17.77 16.43 15.05 13.72 12.11 23 SHC 21.17 19.79 18.46 17.08 15.47 25 SHC 24.58 23.75 21.82 20.48 18.87 27 SHC 27.94 26.56 25.22 23.84 22.19 19 CAP 30.56 29.27 27.80 26.19 24.12 kw 9.53 10.25 10.96 11.74 12.67 23 SHC 17.86 16.52 15.14 13.81 12.20 25 SHC 21.27 19.88 18.55 17.17 15.56 27 SHC 24.67 23.29 21.91 20.57 18.96 29 SHC 28.03 26.65 25.32 23.94 22.37 21 CAP 32.17 31.07 29.60 28.12 26.05 kw 9.74 10.42 11.11 11.88 12.81 25 SHC 17.95 16.62 15.24 13.90 12.29 27 SHC 21.36 19.98 18.64 17.26 15.65 29 SHC 24.76 23.11 22.00 20.67 19.06 31 SHC 28.12 26.74 25.41 24.03 22.46 50VZ 045 (38VZ 045+40PZ 045) - air flow 2640 l/s Ewb Edb Outdoor air temperature C 25 30 35 40 46 15 CAP 44.32 41.71 38.45 35.09 31.14 kw 12.57 14.14 15.73 17.49 19.51 19 SHC 26.21 25.02 23.79 22.21 21.12 21 SHC 31.19 30.01 28.82 27.64 26.11 23 SHC 36.23 34.80 33.81 32.58 30.60 25 SHC 41.21 40.03 38.25 34.99 31.05 17 CAP 47.73 44.91 41.76 38.50 34.75 kw 12.77 14.36 15.92 17.50 19.72 21 SHC 26.65 25.47 24.28 23.05 21.57 23 SHC 31.69 30.40 29.27 28.08 26.55 25 SHC 36.67 35.44 34.25 33.20 31.59 27 SHC 41.71 40.47 39.29 38.00 34.55 19 CAP 51.13 48.47 45.21 41.95 38.25 kw 12.99 14.56 16.14 17.72 19.93 23 SHC 27.15 25.91 24.68 23.49 23.00 25 SHC 32.18 30.90 29.71 28.53 27.05 27 SHC 37.17 35.93 34.75 33.51 32.08 29 SHC 42.20 40.97 39.73 38.50 37.02 21 CAP 54.09 51.53 48.72 45.56 41.71 kw 13.20 14.77 16.35 17.93 20.13 25 SHC 27.64 26.41 25.17 23.99 22.51 27 SHC 32.58 31.39 30.21 28.97 27.49 29 SHC 37.61 36.43 35.19 33.96 32.53 31 SHC 42.59 41.46 40.23 38.99 37.51
Cooling capacities, kw 50VZ 055 (38VZ 055+40PZ 055) - air flow 2910 l/s Ewb Edb Outdoor air temperature C 50VZ 075 (38VZ 075+40PZ 075) - air flow 3530 l/s Correction factors 25 30 35 40 46 15 CAP 53.35 50.44 46.79 42.73 37.24 kw 14.37 16.13 17.87 20.71 22.06 19 SHC 30.47 28.33 26.17 24.00 21.83 21 SHC 37.01 34.84 32.67 30.50 27.92 23 SHC 43.52 41.35 39.18 37.01 34.43 25 SHC 49.98 47.81 45.69 42.64 37.19 17 CAP 57.04 53.90 50.95 46.98 42.09 kw 14.71 16.46 18.22 21.06 22.39 21 SHC 30.83 28.66 26.53 24.37 21.84 23 SHC 37.33 35.16 33.00 30.83 28.24 25 SHC 43.84 41.67 39.50 37.33 34.75 27 SHC 50.35 48.18 46.01 43.84 41.07 19 CAP 60.22 57.33 53.90 50.16 45.04 kw 15.05 16.79 18.54 20.28 22.72 23 SHC 31.20 29.03 26.86 24.69 22.10 25 SHC 37.67 35.53 33.36 31.20 28.61 27 SHC 44.21 41.99 39.87 37.70 35.07 29 SHC 50.67 48.50 46.33 44.21 41.53 21 CAP 63.68 61.01 57.68 53.72 48.92 kw 15.40 17.14 18.88 20.61 23.05 25 SHC 31.52 29.35 27.23 25.01 22.43 27 SHC 38.03 35.90 33.71 31.56 28.93 29 SHC 44.53 42.36 40.19 38.03 26.21 31 SHC 51.04 48.87 46.70 44.53 41.90 Ewb Edb Outdoor air temperature C 25 30 35 40 46 15 CAP 70.52 67.66 64.86 60.41 54.39 kw 21.05 23.99 26.93 29.87 33.14 19 SHC 40.60 38.78 36.97 35.15 32.92 21 SHC 48.43 46.61 44.80 42.98 40.75 23 SHC 56.26 54.49 52.68 50.86 48.64 25 SHC 64.14 62.32 60.51 58.69 54.18 17 CAP 75.03 72.49 69.48 65.23 59.21 kw 21.49 24.43 27.37 30.31 33.66 21 SHC 39.98 38.16 36.35 34.53 32.30 23 SHC 47.81 45.99 44.18 42.41 40.18 25 SHC 55.69 53.87 52.06 50.24 48.01 27 SHC 63.52 61.70 59.89 58.07 55.89 19 CAP 79.85 77.52 74.35 70.67 64.97 kw 21.91 24.85 27.79 30.73 34.25 23 SHC 39.35 37.54 35.72 33.91 31.73 25 SHC 47.18 45.42 43.61 41.79 39.56 27 SHC 55.06 53.25 51.44 49.62 47.44 29 SHC 62.95 61.13 59.32 57.50 55.27 21 CAP 85.80 83.27 80.26 76.63 70.46 kw 22.54 25.83 28.22 31.06 34.47 25 SHC 38.78 36.97 35.15 33.34 31.11 27 SHC 46.61 44.80 42.98 41.17 38.94 29 SHC 54.49 52.68 50.86 49.05 46.82 31 SHC 62.32 60.51 58.69 56.88 54.65 50VZ 40PZ + 38VZ Indoor air flow % 80 90 110 120 015 CAP 0.94 0.97 1.03 1.05 SHC 0.92 0.96 1.03 1.04 kw 0.96 0.98 1.02 1.03 025 CAP 0.96 0.98 1.02 1.04 SHC 0.92 0.96 1.03 1.06 kw 0.98 0.99 1.01 1.02 030-031 CAP 0.98 0.99 1.01 1.02 SHC 0.94 0.97 1.02 1.05 kw 0.98 0.99 1.01 1.02 040 CAP 0.96 0.98 1.02 1.04 SHC 0.92 0.97 1.03 1.06 kw 0.97 0.99 1.01 1.02 045-075 CAP 0.96 0.98 1.02 1.04 SHC 0.92 0.96 1.03 1.06 kw 0.97 0.99 1.01 1.02 CAP - Cooling capacity SHC - Sensible heat capacity kw - Compressor power input 50VZ 065 (38VZ 065+40PZ 065) - air flow 3140 l/s Ewb Edb Outdoor air temperature C 25 30 35 40 46 15 CAP 60.59 58.14 55.74 51.90 46.74 kw 17.63 19.86 22.09 24.32 26.86 19 SHC 34.88 33.33 31.77 30.21 28.29 21 SHC 41.61 40.05 38.49 36.93 35.02 23 SHC 48.34 46.82 45.27 43.71 41.79 25 SHC 55.11 53.55 51.99 50.43 46.56 17 CAP 64.47 62.28 59.70 56.05 50.88 kw 17.79 20.02 22.25 24.48 27.02 21 SHC 34.35 32.79 31.23 29.67 27.76 23 SHC 41.08 39.52 37.96 36.44 34.53 25 SHC 47.85 46.29 44.73 43.17 41.26 27 SHC 54.58 53.02 51.46 49.90 48.03 19 CAP 68.61 66.61 63.89 60.72 55.82 kw 17.94 20.17 22.40 24.63 27.31 23 SHC 33.82 32.26 30.70 29.14 27.27 25 SHC 40.54 39.03 37.47 35.91 33.99 27 SHC 47.31 45.76 44.20 42.64 40.77 29 SHC 54.09 52.53 50.97 49.41 47.49 21 CAP 72.84 71.55 68.97 65.85 60.55 kw 17.87 20.21 22.56 24.90 27.72 25 SHC 33.33 31.77 30.21 28.65 26.73 27 SHC 40.05 38.49 36.93 35.37 33.46 29 SHC 46.82 45.27 43.71 42.15 40.23 31 SHC 53.55 51.99 50.43 48.87 46.96 Legend: CAP - Total cooling capacity, kw Edb - Entering dry bulb temperature, ºC Ewb - Entering wet bulb temperature, ºC kw - Compressor power input SHC - Sensible heat capacity, kw
Cooling capacities (condensing unit 38VZ) 38VZ SST Condenser entering air temperature, C C 25 30 35 40 46 CAP kw CAP kw CAP kw CAP kw CAP kw 015 0 11.33 4.19 10.61 4.50 9.84 4.91 9.07 5.11 8.40 5.42 2 12.39 4.30 11.62 4.60 10.85 5.01 9.99 5.22 9.27 5.52 4 13.44 4.40 12.63 4.70 11.86 5.11 10.90 5.32 10.13 5.62 6 14.50 4.50 13.68 4.81 12.92 5.22 11.96 5.52 11.14 5.73 8 15.80 4.60 14.88 4.91 14.02 5.32 13.01 5.73 12.15 5.93 10 17.14 4.70 16.13 5.01 15.08 5.42 13.97 5.83 13.06 6.14 12 18.44 4.81 17.38 5.11 16.33 5.52 15.08 6.03 14.02 6.34 025 0 17.37 6.65 16.04 6.96 14.71 7.27 13.79 7.68 12.55 7.79 2 19.07 6.75 17.60 7.06 16.13 7.48 15.17 7.79 13.97 8.00 4 20.77 6.85 19.16 7.16 17.55 7.68 16.54 7.89 15.39 8.20 6 22.61 6.96 20.86 7.37 19.16 7.79 18.11 8.10 16.87 8.51 8 24.82 7.06 22.79 7.48 20.77 7.89 19.58 8.31 18.29 8.72 10 26.56 7.16 24.59 7.58 22.61 8.00 21.28 8.41 19.71 8.93 12 28.68 7.27 26.65 7.68 24.54 8.10 23.12 8.62 21.42 9.24 030 0 24.71 8.33 22.35 8.96 19.98 9.59 19.16 9.81 17.11 10.23 2 26.61 8.54 24.25 9.17 21.89 9.81 20.91 10.02 18.55 10.65 4 28.51 8.75 26.15 9.38 23.79 10.02 22.66 10.23 19.98 11.07 6 30.98 8.96 28.56 9.59 26.15 10.33 24.71 10.65 21.89 11.39 8 34.11 9.17 31.08 9.81 27.90 10.54 26.61 11.07 23.68 11.81 10 36.63 9.38 33.55 10.02 30.46 10.86 29.03 11.28 25.69 12.13 12 39.30 9.59 36.06 10.23 32.83 11.07 31.39 11.70 27.59 12.55 031 0 19.64 8.52 19.04 9.33 18.43 9.94 16.70 10.24 15.36 10.55 2 22.85 8.72 21.50 9.53 20.16 10.14 18.52 10.55 17.18 10.95 4 26.05 8.93 23.97 9.74 21.89 10.35 20.34 10.85 18.99 1136 6 27.43 9.13 25.61 9.94 23.80 10.75 22.15 11.26 20.42 11.77 8 29.59 9.33 27.69 10.14 25.79 10.95 23.97 11.66 22.46 12.17 10 32.28 9.53 30.07 10.35 27.86 11.16 25.96 11.97 24.36 12.58 12 34.31 9.74 32.23 10.55 30.16 11.36 28.08 12.17 26.44 12.98 040 0 27.58 10.91 26.04 11.51 24.50 12.02 22.91 13.25 21.06 14.74 2 30.36 11.21 28.46 11.82 26.57 12.42 24.98 13.62 23.13 15.06 4 33.13 11.51 30.89 12.12 28.64 12.82 27.05 13.99 25.20 15.38 6 35.56 11.71 33.40 12.42 31.24 13.12 29.52 14.29 27.58 15.71 8 38.99 12.02 36.44 12.72 33.84 13.42 31.94 14.75 29.65 16.35 10 41.42 12.42 38.99 13.02 36.57 13.72 34.54 15.10 32.08 16.77 12 44.68 12.52 42.25 13.32 39.83 14.12 37.23 15.43 34.50 16.99 045 0 37.63 12.42 33.90 13.42 29.85 14.12 26.27 15.98 20.88 18.21 2 40.57 12.62 36.80 13.62 32.61 14.42 28.93 16.20 23.32 18.32 4 43.52 12.82 39.70 13.82 35.37 14.72 31.60 16.41 25.76 18.43 6 46.64 13.02 42.73 14.22 38.64 15.12 34.55 16.67 28.38 18.53 8 49.91 13.32 46.09 14.52 41.95 15.52 37.72 16.98 31.10 18.74 10 53.08 13.82 49.40 15.02 45.40 16.02 41.12 17.35 34.50 18.95 12 56.63 14.42 52.95 15.52 49.04 16.53 44.80 17.83 37.86 19.38 055 0 42.96 13.57 39.48 14.35 36.09 15.31 31.18 16.80 23.34 18.61 2 46.94 14.26 43.13 15.05 39.44 16.00 34.53 17.52 26.39 19.35 4 50.92 14.96 46.77 15.74 42.79 16.70 37.87 18.24 29.44 20.10 6 54.90 15.66 50.45 16.44 46.30 17.31 41.35 18.92 32.62 20.84 8 59.27 16.26 54.48 17.05 50.12 17.92 45.33 19.63 36.18 21.68 10 63.67 16.87 58.72 17.57 53.93 18.53 49.23 20.31 40.29 22.42 12 68.04 17.40 62.87 18.18 57.91 19.05 53.08 20.88 44.74 23.08 065 0 55.19 17.62 50.22 17.96 46.25 18.79 40.99 20.20 31.68 21.90 2 59.03 18.13 54.10 18.63 49.97 19.46 44.67 20.97 35.36 22.79 4 62.87 18.63 57.98 19.30 53.68 20.13 48.34 21.75 39.03 23.68 6 66.92 19.13 61.95 19.88 57.44 20.80 52.14 22.52 42.83 24.57 8 71.30 19.71 66.08 20.55 60.82 21.47 55.94 23.28 46.63 25.46 10 76.06 20.30 70.80 21.30 65.62 22.22 60.32 24.13 51.01 26.44 12 81.11 20.97 75.85 21.97 70.47 22.97 65.04 25.04 55.73 27.51 075 0 66.35 23.48 60.38 23.93 55.61 25.04 49.29 26.96 38.09 29.25 2 70.97 24.15 65.05 24.82 60.08 25.93 53.70 27.98 42.51 30.44 4 75.59 24.82 69.72 25.71 64.55 26.82 58.12 29.00 46.93 31.63 6 80.46 25.48 74.48 26.49 69.06 27.71 62.69 30.03 51.50 32.82 8 85.73 26.26 79.45 27.38 73.13 28.60 67.26 31.05 56.06 34.01 10 91.45 27.04 85.12 28.38 78.90 29.60 72.53 32.20 61.33 35.31 12 97.52 27.93 91.20 29.27 84.72 30.60 78.20 33.39 67.00 36.74 CAP - Total cooling capacity, kw kw - Compressor power input SST - Dew point suction temperature, C
Fan performance 50VZ 015 indoor fan (40PZ 015) standard 50VZ 015 indoor fan (40PZ 015) optional larger 50VZ 015 outdoor fan (38VZ 015) standard Indoor fan Curve Pulley open Standard 0 Closed 19.6 23.08 1 1 18.75 22.18 2 2 18.33 21.28 3 3 17.67 20.38 4 4 17 19.5 5 5 16.33 18.6 Outdoor fan Standard Factory 3.5 17.33 15.25
Fan performance 50VZ 025 indoor fan (40PZ 025) standard 50VZ 025 indoor fan (40PZ 025) optional larger 50VZ 025 outdoor fan (38VZ 025) standard 50VZ 025 outdoor fan (38VZ 025) optional larger Indoor fan Curve Pulley open Standard Outdoor fan Standard 0 Closed 19.8 20.5 17.42 19.33 1 1 18.33 19.83 16.66 18.46 2 2 17.58 19.16 15.92 17.6 3 3 16.83 18.5 15.16 16.73 4 4 16.08 17.83 14.42 15.86 5 5 15.33 17.16 13.66 15 Factory 3.5/2* 16.45 15.92 * The first value is for the indoor unit pulley; the second value is for the outdoor unit pulley
Fan performance 50VZ 030-031 indoor fan (40PZ 030-031) standard 50VZ 030-031 indoor fan (40PZ 030-031) optional larger 50VZ 030-031 outdoor fan (38VZ 030-031) standard 50VZ 030-031 outdoor fan (38VZ 030-031) optional larger Indoor fan Curve Pulley open Standard Outdoor fan Standard 0 Closed 19.33 21.76 18.2 20.5 1 1 18.5 20.76 17.36 19.58 2 2 17.66 19.76 16.53 18.66 3 3 16.92 18.76 15.7 17.75 4 4 15.83 17.76 14.86 16.83 5 5 14.92 16.76 14.03 15.92 Factory 2.5/2* 17.29 16.53 * The first value is for the indoor unit pulley; the second value is for the outdoor unit pulley
Fan performance 50VZ 040 indoor fan (40PZ 040) standard 50VZ 040 indoor fan (40PZ 040) optional larger 50VZ 040 outdoor fan (38VZ 040) standard 50VZ 040 outdoor fan (38VZ 040) optional larger Indoor fan Curve Pulley open Standard Outdoor fan Standard 0 Closed 21.92 24.33 15 17 1 1 21.08 23.42 14.5 16.33 2 2 20.25 22.5 14 15.66 3 3 19.42 21.58 13.5 15 4 4 18.5 20.66 13 14.33 5 5 17.58 19.75 12.5 13.66 Factory 2.5/2.5* 19.84 13.75 * The first value is for the indoor unit pulley; the second value is for the outdoor unit pulley
Fan performance 50VZ 045 indoor fan (40PZ 045) standard 50VZ 045 indoor fan (40PZ 045) optional larger 50VZ 045 outdoor fan (38VZ 045) standard 50VZ 045 outdoor fan (38VZ 045) optional larger Indoor fan Curve Pulley open Standard Outdoor fan Standard 0 Closed 19.5 21.33 12.25 12.83 1 1 18.66 20.58 11.75 12.33 2 2 17.92 19.83 11.25 11.83 3 3 17.16 19.08 10.75 11.33 4 4 16.42 18.33 10.25 10.83 5 5 15.66 17.58 9.75 10.33 Factory 3/3* 17.16 10.75 * The first value is for the indoor unit pulley; the second value is for the outdoor unit pulley
Fan performance 50VZ 055 indoor fan (40PZ 055) standard 50VZ 055 indoor fan (40PZ 055) optional larger 50VZ 055 outdoor fan (38VZ 055) standard 50VZ 055 outdoor fan (38VZ 055) optional larger Indoor fan Curve Pulley open Standard Outdoor fan Standard 0 Closed 21.16 22.75 13 15 1 1 20.42 22 12.5 14.5 2 2 19.66 21.16 12 14 3 3 18.92 20.42 11.5 13.5 4 4 18.16 19.58 11 13 5 5 17.42 18.83 10.5 12.5 Factory 4/2* 18.16 12 * The first value is for the indoor unit pulley; the second value is for the outdoor unit pulley
Fan performance 50VZ 065 indoor fan (40PZ 065) standard 50VZ 065 indoor fan (40PZ 065) optional larger 50VZ 065 outdoor fan (38VZ 065) standard 50VZ 065 outdoor fan (38VZ 065) optional larger Indoor fan Curve Pulley open Standard Outdoor fan Standard 0 Closed 21.5 22.66 12.75 14.33 1 1 20.66 21.9 12.25 13.83 2 2 19.83 21.13 11.75 13.33 3 3 19 20.36 11.25 12.73 4 4 18.16 19.6 10.83 12.33 5 5 17.33 18.83 10.42 11.83 Factory 3.5/2* 18.58 11.75 * The first value is for the indoor unit pulley; the second value is for the outdoor unit pulley
Fan performance 50VZ 075 indoor fan (40PZ 075) standard 50VZ 075 indoor fan (40PZ 075) optional larger 50VZ 075 outdoor fan (38VZ 075) standard 50VZ 075 outdoor fan (38VZ 075) optional larger Indoor fan Curve Pulley open Standard Outdoor fan Standard 0 Closed 22.66 23.58 14.33 15 1 1 21.9 22.75 13.83 14.5 2 2 21.13 21.92 13.33 14 3 3 20.36 21.08 12.83 13.5 4 4 19.6 20.25 12.33 13 5 5 18.83 19.42 11.83 12.5 Factory 3/2.5* 20.36 13.08 * The first value is for the indoor unit pulley; the second value is for the outdoor unit pulley
Order No. 15001-20, 11.2001. Supersedes New. Manufacturer reserves the right to change any product specifications without notice. Printed in the Netherlands.