GuardShield TM Safe 4 GuardShield TM Safe 4 PAC

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

SensaGuard TM Integrated Latch Installation Instructions

Installation And commissioning manual. Series S Double Beam 1/16

Online data sheet WS/WE45-P260S01 W45 PRODUCT PORTFOLIO

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

GuardShield PAC Type 4 (Perimeter Access Control) Safety Light Curtain User Manual

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

OIL FILM DETECTOR (Long-distance correspondence Version)

F3SJ Overview. Three Versions available to meet your exact safety needs. Safety Light Curtains NEW! Introducing the F3SJ Series

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Safety Function: Single-beam Area Access Control (AAC)

Flameproof Type Light Curtain Type 4

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Dräger Polytron 5700 IR Detection of flammable gases and vapours

MA Series. Safety, Technology & Innovation MA 12 MA 13. Description. Approvals. Operation. Applications. Declaration Conformity

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

Shown here with optional quick-disconnect cable kit.

Class 1 laser beam sensor safe for your eyes

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

/ / 2018

CM Series. Safety, Technology & Innovation. Description. Approvals. Operation. Applications. Certificate of Conformity

Safety Light Curtain F3SG-R


PROFIBUS-PA Display RID 261 PROFIBUS-PA

Class 1 laser beam sensor safe for your eyes

Contents. Photoelectric Sensors / Standard Sensors...4. Safety Sensors Photoelectric Sensors / Miniature Sensors... 12

FF-SYB14, FF-SYB30 and FF-SYB50 Series Safety Light Curtains. FF-SYB234 Multibeam Systems for Access Detection

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

Class 1 laser beam sensor safe for your eyes

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

Retroreflective sensor with polarization filter

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Safe Machines with opto-electronic protective devices. Reliable safety and flexibility in an advanced manner.

Series 25B Photoelectric Sensors and Light Scanners PRODUCT INFORMATION

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

Small Light Curtain. Industry s smallest Type 4 light curtain for safeguard SERIES

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Retroreflective sensor with polarization filter

culus and CE Marked for all applicable directives Operating Environment Operating Temperature [C (F)]

Magnetically Coded Non-contact Switch (MC2)

FF-ST4 Series. Type 4 Safety Light Curtains. Potential Applications. Features

Wiring Transmitter and Detectors. mounting hole. A023a. mounting hole. A024a

Single-beam Photoelectric Safety Switches and Multiple Light Beam Safety Devices

INFRARED MODULATED BARRIERS

GuardShield Safe 2 and Safe 2 PAC Safety Light Curtains User Manual

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

Compact Catalog Solar

UV Flame Supervision System

DUAL OPTIC. Installation manual

General Specifications

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

Laser Collimated Beam Sensor

MBCE-110/230UV Flame Sensor Module

SELECTION TABLE x 42 x x 48 x x 50 x M12 x 70. Housing material. Typ. operating range/scanning range [mm]

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning. Sensor. Ensure productivity. Emergency stop.

Ultrasonic Proximity Sensor

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

PHOTOELECTRIC AMPLIFIER SERIES

SAFETY INTERFACES SAFETY INTERFACES AND RELAYS

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

Adjustable Range Reflective Photoelectric Sensor. General terms and conditions... F-17 Glossary of terms / General precautions...p.1359~ / P.

E3M-V. Mark Sensor. Applications

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

MLDSET Light Beam Safety Device Sets for access guarding with muting function

Emitter. Emitting circuit. Control circuit. Check. Monitoring section (CPU) Emitting element failure. Emitting circuit failure

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Annunciator Unit SACO 16 D1. Product Guide

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Dräger Polytron 5720 IR Toxic Gas Detection

SENSOR SOLUTIONS FOR DOORS

Interface and EOL Modules 8

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

Machine Guarding and Safety

Quick-disconnect cables. Adjustable mounting brackets

Annunciator unit. Application

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing

onlinecomponents.com

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Movement Detector GJD 300

Sensing light curtain as per DIN 18650/EN 16005

Innovation right to the point. Optical distance detection. Low cost and compact due to PMD technology.

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

D-Tect 2 GJD300 Quad PIR Movement Detector

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

E3FA PHOTOELECTRIC SENSORS

ISIS SAFETY SYSTEM Installation guide

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Analog Annunciator Unit SACO 16 A3. Product Guide

Call for more information RP-QM72/QMT72 page 644. RP-LS42 page 643. RP-RM83 page 642

Transcription:

Presence Sensing Safety Devices Description The AAC photoelectric safety switch is a single-beam, noncontact presence sensing safety device consisting of separate transmitter and receiver units. The light beam produced between the emitter and receiver provides access protection for hazardous areas. The AAC serves as a presence sensing safety device for perimeter guarding to protect personnel from potentially hazardous areas such as: Robotic work cells Machining centres Palletizers Plastics machinery Stackers Settling machinery in the stone working industry Features Long scan range Easy installation Die cast aluminium housing Heated front lens, i.e. it can be used even in outdoor applications Specifications Standards EN 50100 Approvals BG and CE marked for all applicable directives Protective Field Range 0.5 to 18m or 15 to 70m Number of Beams 1 Light Beam Diameter 23mm Sender/ Unit Supply Voltage ±20% +15% to -10% (special order) +15% to -10% Ripple Max. 5% of Uv Frequency 48 to 62Hz with AC version, Sender Test contact Test Time Max. 150ms Min. Opening Time of NC 75ms Contact for Test Power Consumption Voltage Version 24V 115V 230V Sender Unit 5W 8W 8W Unit 8W 11W 11W Synchronization Optical Safety Relays Max. Operating Frequency 0.2Hz (1 operation in 5 seconds) Switching Current (max./ 2A/0.02A min.) Switching Voltage (max./ 250V AC/ min.) Response Time 22ms Connection Cable PG connector: IP67, max cable length 50m Front Screen Heating Standard Operating Data Protection Class I Enclosure Rating IP67 Safety Category Type 4 Requirements EN 50100 Part I/Part II Ambient Operating -25 C to 55 C Temperature Storage Temperature -25 C to 70 C Air Humidity 15% to 95% Vibration 5g, 10 to 55Hz to IEC 68-2-6 Impact Resistance 10g, 16ms to IEC 68-2-29 Weight Sender unit: approx. 0.9 to 1.3kg unit: approx. 1 to 1.4kg 2-46

Product Selection 1a. Selection Guide for 0.5m to 18m Range 1b. Selection Guide for 15m to 70m Range 2. Safety Relay Interfaces Optional if additional outputs required Presence Sensing Safety Devices Operating Voltage Supply Current Connection Type Terminal Chamber with 440L-T4F0018-Q 440L-R4F0018-Q 120V AC Cable Gland (PG13.5 thread) 440L-T4F90018-Q 440L-R4F90018-Q Operating Voltage Supply Current Connection Type Terminal Chamber with 440L-T4F0070-Q 440L-R4F0070-Q 120V AC Cable Gland (PG13.5 thread) 440L-T4F90070-Q 440L-R4F90070-Q Voltage Reset Manual/ Automatic Floating Blanking Note: For wiring refer to Safeguarding Applications section of this catalogue. Fixed Blanking PSDI Muting no no no no Safety 4 amp 2 N.O. Safety 1 N.C. Aux. More Details 58 440L-M8200 3. Safety Relay Interfaces Optional Relay MSR127RP MSR126 1NC, 2NC, or Light Curtain Light Curtain or Single Channel (MSR126T) Dual Channel (MSR126.1T) Light Curtain or Single Channel (MSR126R) Dual Channel (MSR126.1R) Safety Auxiliary Terminals 3 N.O. 1 N.C. Removable 2 N.O. None Fixed Power Supply Reset Catalogue Number 440R-N23132 440R-N23135 440R-N23131 440R-N23134 440R-N23130 440R-N23133 440R-N23117 440R-N23116 440R-N23115 440R-N23114 440R-N23113 440R-N23112 440R-N23123 440R-N23122 440R-N23121 440R-N23120 440R-N23119 440R-N23118 440R-C23139 Light Curtain or Safety Mat 3 N.O. 2 N.C. 2 PNP Solid State Removable or 440R-C23137 MSR131RTP 440R-C23136 2-47

Presence Sensing Safety Devices Accessories Description Laser alignment aid Adaptor for alignment aid on AAC 440L-ALAT 440L-ALBRK1 Mounting bracket for AAC Corner mirror for scanning range 0 to 30m Mounting kit for 440L-AMIRR1 440L-AMBRK4 440L-AMIRR1 440L-AMKIT Mounting bracket for mirror 440L-AMIRRI 440L-AMBRK1 Glass corner mirror, 45 angle 0 to 30m 440L-AMIRR2 Long range mirror (15 to 79m) 440L-AMIRR3 Adaptor, Conduit, Pg13.5 to 1/2in NPT, Steel 440A-A17094 2-48

Approximate Dimensions mm (inches) Approximate Dimensions are not intended to be used for installation purposes. Presence Sensing Safety Devices 50 (1.96) 116 (4.57) 65 (2.5) 34 (1.33) 156 (6.14) 128 (5.03) 65 (2.5) 14 (0.55) 17.5 (0.68) Pg 13.5 Max Cable O.D. 8-10mm M6 x 8 (6 places) 2-49

Presence Sensing Safety Devices Approximate Dimensions mm (inches) (continued) Approximate Dimensions are not intended to be used for installation purposes. 9 (0.35) 65 51 6.5 (0.26) (2.56)(2.01) 20 (0.79) 26 (1.02) M 8 x 30 SW 13 20 64.5 (2.54) 46.5 (1.83) 39.5 64.5(1.55) (2.54) 60 82 (3.23) 9 (0.35) 43 (1.69) 40 (1.57) 58 (2.28) 20 71 (0.79) (2.80) M 8 x 45 SW 13 6 (0.23) 6.5 (0.25) 22 (0.87) Mounting bracket 440L-AMBRK4 67 (2.64) 16.5 (0.65) 33.5 (1.32) 63 (2.48) M6 160 (6.30) 149 (5.87) 177 (6.97) 124 (4.88) ~7 (0.28) 38 (1.50) 2.5 (0.10) 96 (3.78) 14 8.5 10 (.039) 100 (3.94) (0.55) (0.33) Corner mirror Catalogue number 440L-AMIRR1 Shown with bracket (440L-AMBRK1) Mounted to mirror (440L-AMIRR1) 76 (2.99) 80 (3.15) 96.5 (3.80) 40.5 (1.59) 40 (1.57) 63 (2.48) 8.5 (0.33) 146.5 (5.77) Catalogue number 440L-AMIRR2 69.5 (2.74) 8.5 (0.33) 80 (3.15) 2-50

Typical Wiring Diagrams Presence Sensing Safety Devices 1/2 3 10 11 1/2 3 4 5 6 7 8 9 0V DC Test 0V DC N.C. Output supply with terminal chamber 1/2 3 10 11 1/2 3 4 5 6 7 8 9 115V DC Test L1 N N.C. Output AC power supply with terminal chamber 2-51