Tip obsega: fleksibilen (možnost uvajanja manjših sprememb ) / Type of scope: flexible (possibility of implementing minor modifications of the method) Mesto izvajanja: v laboratoriju / Sit e: in the laboratory Področje preskušanja glede na vrsto preskušanca: gradbeni proizvodi, in / Testing fields with reference to the type of test item: products, and structures Oznaka a ali nene preskusne Reference to or non Naslov a ali nene preskusne in morebitne navezave na druge e ali Title of or non- and eventual relations to other s or me-thods 1. SIST EN ISO 354:2004 Izračun po ih/ s - SIST EN 1793-1 ( / noise reducing barriers ) - SIST EN ISO 11654 (absorberji zvoka / noise absorbers ) Akustika - merjenje absorpcije zvoka v odmevnici Acoustics-Measurement of sound absorption in a reverberation room from 50 Hz to 5000 Hz α spodnja meja: 0,01 zgornja meja: 1 lower limit: 0,01 upper limit: 1, absorberji in,, absorbers and structures, noise reducing barriers 2. SIST EN ISO 10140-2:2010 V skladu s i / With application of s - SIST EN ISO 10140-1 - SIST EN ISO 10140-4 - SIST EN ISO 10140-5 Izračun po u / Akustika - Laboratorijsko merjenje zvočne izolirnosti gradbenih elementov - 1. del: Pravila uporabe za določene izdelke - 2. del: Merjenje izolirnosti pred zvokom v zraku - 4. del: Merilni postopki in zahteve - 5. del: Zahteve in oprema za laboratorije Acoustics - Laboratory measurement of sound of building elements - Part 1: Application rules for specific products - Part 2: Measurement of airborne sound - Part 4: Measurement procedures and requirements - Part 5: Requirements for test facilities and equipment from 50 Hz to 5000 Hz maksimalna in minimalna R w / maximum and minum R w - okna in vrata / windows and doors : zgornja meja: 49 db lower limit: 5 db upper limit : 49 db - lahke montažne stene / light assembly walls : zgornja meja: 63 db upper limit : 63 db - lahke masivne stene / light massive walls : zgornja meja: 63 db upper limit: 63 db - težke masivne stene / heavy massive walls : zgornja meja: 72 db upper limit : 72 db Zgornje meje pogojene s frekvenčnim potekom izolirnosti vzorca. Upper limits conditional to index frequency dependance of a specimen. okna in vrata, lahke montažne stene, težke masivne stene, lahke masivne stene in protihrupne ograje windows and doors, assembly walls, heavy massive walls, light massive walls and noise reducing barriers 3. SIST EN ISO 15186-1:2004 Akustika Merjenje zvočne izolirnosti v zgradbah in zvočne izolirnosti gradbenih elementov z uporabo zvočne intenzitete 1.del: Laboratorijska merjenja Acoustics Measurement of sound in buildings and of building elements using sound intensity Part 1: Laboratory measurements zgornja meja: 70 db upper limit: 70 db okna in vrata, lahke montažne stene, težke masivne stene, lahke masivne stene in protihrupne ograje windows and doors, assembly walls, heavy massive walls, light massive walls and noise reducing barriers Obr. P.F.10-001-2/2 Stran 1 od 5
Tip obsega: fleksibilen (možnost uvajanja manjših sprememb ) / Type of scope: flexible (possibility of implementing minor modifications of the method) Mesto izvajanja: na terenu / Sit e: on site Področje preskušanja glede na vrsto preskušanca: gradbeni proizvodi, in / Testing fields with reference to the type of test item: products, and structures Oznaka a ali nene preskusne Reference to or non Naslov a ali nene preskusne in morebitne navezave na druge e ali Title of or non- and eventual relations to other s or me-thods 4. SIST EN ISO 16283-1:2014 Izračun po u / Akustika - Terenska merjenja zvočne izolirnosti stavbnih elementov in v stavbah - 1. del: Izolirnost pred zvokom v zraku Acoustics - Field measurement of sound in buildings and of building elements - Part 1: Airborne sound lower limit : 1 db gradbeni elementi in elements, and structures 5. SIST EN ISO 16283-2:2016 Izračun po u / Akustika - Terenska merjenja zvočne izolirnosti v stavbah in stavbnih elementih - 2. del: Izolirnost pred udarnim zvokom Acoustics - Field measurement of sound in buildings and of building elements - Part 2: Impact sound L n,w : spodnja meja: odvisna od residualnega hrupa 40 db lower limit: depend on residual noise 40 db medetažne floors 6. SIST EN ISO 16283-3:2016 Izračun po u / Akustika - Terenska merjenja zvočne izolirnosti v stavbah in stavbnih elementih - 3. del: Izolirnost fasade Acoustics - Field measurement of sound in buildings and of building elements - Part 3: Façade sound R' 45 fasadni elementi in fasade façade elements and facades 7. SIST EN ISO 3382-1:2009 8. SIST EN ISO 3382-2:2008 Akustika - Merjenje akustičnih parametrov v prostorih - 1. del: Prostori za prireditve Acoustics - Measurement of room acoustic parameters - Part 1: Performance spaces Akustika - Merjenje parametrov prostorske akustike - 2. del: Odmevni čas v običajnih prostorih Acoustics - Measurement of room acoustic parameters - Part 2: Reverberation time in ordinary rooms konstantna raven zvoka raven ozadja / constant level of sound level of background noise < 35 db from 100 Hz to 5000 Hz odmevni čas od 100 ms do 20 s reverberation time: from 100 ms to 20 s prostori za prireditve performance spaces običajni prostori ordinary rooms 9. SIST-TS CEN/TS 1793-5:2004 Protihrupne ovire za cestni promet - Preskusna metoda za ugotavljanje akustičnih lastnosti - 5. del: Bistvene lastnosti - Terenske vrednosti odboja zvoka in izolirnosti pred zvokom v zraku Road traffic noise reducing devices - Test method for determining the acoustic performance - Part 5: Intrinsic characteristics - In situ values of sound reflection and airborne sound DL' SI spodnja meja: ~ 1 db zgornja meja: ~ 80 db lower limit: ~ 1 db upper limit: ~ 80 db DL' R spodnja meja: ~ 0 db zgornja meja: ~ 1 db lower limit: ~ 0 db upper limit: ~ 1dB noise barriers 10. SIST EN 1793-6:2013 Protihrupne ovire za cestni promet - Preskusna metoda za ugotavljanje akustičnih lastnosti - 6. del: Bistvene lastnosti - Terenske vrednosti izolirnosti pred zvokom v zraku 'Road traffic noise reducing devices - Test method for determining the acoustic performance - Part 6: Intrinsic characteristics - In situ values of airborne sound under direct sound field conditions DL' SI spodnja meja: ~ 1 db zgornja meja: ~ 80 db lower limit: ~ 1 db upper limit: ~ 80 db noise barriers 11. 13. Tehnična smernica TSG-1-005:2012 Zaščita pred hrupom v stavbah,poglavje 8.5 Technical guiedline TSG-1-005:2012 part 8.5 :2007 V skladu s om / With application of SIST ISO 1996-1 Merjenje hrupa v stavbi Noise measuring in buildings Akustika Opis, merjenje in ocena hrupa v okolju 2.del: Določanje ravni hrupa v okolju Acoustics Description, measurement and assessment of al noise Part 2: Determination of al noise levels / : (16 12500) Hz spodnja meja / lower limit : (L min +10 db): - linearno / linear : 31 db - po A / A-weighted : 23 db(a) - po C / C-weighted : 28 db(c) zgornja meja / upper limit : 130 db / : (16 12500) Hz spodnja meja / lower limit : (L min +10 db): - linearno / linear : 31 db - po A / A-weighted : 23 db(a) - po C / C-weighted : 28 db(c) zgornja meja / upper limit : 130 db obratovalna oprema in prostori druge namembnosti, viri zunaj stavbe Installations, other noise sources in building, outside noise sources Obr. P.F.10-001-2/2 Stran 2 od 5
Tip obsega: fleksibilen (možnost uvajanja manjših sprememb ) / Type of scope: flexible (possibility of implementing minor modifications of the method) Mesto izvajanja: na terenu in v laboratoriju / Sit e: on site and in the laboratory Področje preskušanja glede na vrsto preskušanja: akustika, hrup, vibracije (hrup) / Testing fields with reference to the type of test: acoustics, noise, vibration (noise) Področje preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (okolje) / Testing fields with reference to the type of test item: and samples from () Oznaka a ali nene preskusne Reference to or non Naslov a ali nene preskusne in morebitne navezave na druge e ali Title of or non- and eventual relations to other s or me-thods 14. NMPB / XPS 31-1331:2001 V povezavi s om/ In connection with Francoska nacionalna metoda računanja "NMPB-Routes-96 (SETRA-CERTU-LCPC-CSTB) " in francoski "XPS 31-133" Ocenjevanje hrupa cestnega prometa z modelnim izračunom 15. R RMR-SRM II:1996 V povezavi s om/ In connection with Modelni izračun za hrup železniškega prometa "Reken-en Meetvoorschrift Railverkeerslawaai '96, Ministerie Volkshuisvesting, Ruimtelijke Ordening en Milieubeheer, 20. novembra 1996" 16. SIST ISO 9613-2:1997 V povezavi s om/ In connection with Akustika-Slablenje zvoka pri širjenju na prostem - 2. del: Splošna metoda za računanje Acoustics -- Attenuation of sound during propagation outdoors -- Part 2: General method of calculation Obr. P.F.10-001-2/2 Stran 3 od 5
Tip obsega: fleksibilen (možnost uvajanja manjših sprememb ) / Type of scope: flexible (possibility of implementing minor modifications of the method) Mesto izvajanja: na terenu / Sit e: on site Področje preskušanja glede na vrsto preskušanca: gradbeni proizvodi, in / Testing fields with reference to the type of test item: products, and structures Oznaka a ali nene preskusne Reference to or non Naslov a ali nene preskusne in morebitne navezave na druge e ali Title of or non- and eventual relations to other s or me-thods 17. SIST ISO 8302:1997 Toplotna izolacija Določanje toplotne upornosti in sorodnih lastnosti v stacionarnem stanju Aparat z zaščitenimi vročimi ploščami Thermal - Determination of steady-state thermal resistance and related properties - Guarded hot plate apparatus gradbeni 18. SIST EN 12667:2002 Toplotne karakteristike gradbenih materialov in proizvodov Ugotavljanje toplotne upornosti z zaščiteno vročo ploščo in/ali merilniki toplotnih tokov Proizvodi z visoko ali srednjo toplotno upornostjo Thermal performance of building and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Products of high and medium thermal resistance 19. SIST EN 12939:2001 Toplotne značilnosti gradbenih materialov in proizvodov Ugotavljanje toplotne upornosti s ščiteno ploščno napravo in z napravo z merilniki gostote toplotnega toka Izdelki velike debeline z visoko ali srednje visoko toplotno upornostjo Thermal performance of building and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Thick products of high and medium thermal resistance 20. SIST EN 1026:2001 Okna in vrata Propustnost zraka Preskusna metoda Windows and doors - Air permeability - Test method -2kPa do +2 kpa (0-100) m3 /h 21. SIST EN 1027:2001 Okna in vrata Nepropustnost za vodo Preskusna metoda Windows and doors Watertightness - Test method (0 2) kpa, višina vzorca do 2500 mm (0 2) kpa, height of sample up to 2500 mm 22. SIST EN 12211:2001 Okna in vrata Odpornost proti obremenitvi z vetrom Preskusna metoda Windows and doors - Resistance to wind load - Test method 23. SIST EN 822:2013 24. SIST EN 823:2013 25. SIST EN 824:2013 26. SIST EN 825:2013 Določanje dolžine in širine Determination of length and width Določanje debeline Determination of thickness Določanje pravokotnosti Determination of squareness Določanje ploskosti Determination of flatness dolžina / length : 9000 mm, širina / width : 1500 mm debelina do 150 mm thickness up to 150 mm dolžina / length : 1500 mm, širina / width : 1500 mm debelina do 150 mm thickness up to 150 mm 27. SIST EN 12431:2013 Določanje debeline izolacijskih proizvodov za plavajoče pode Determination of thickness for floating floor insulating products debelina / length > 10 mm Obr. P.F.10-001-2/2 Stran 4 od 5
Tip obsega: fiksni / Type of scope: fixed Mesto izvajanja: v laboratoriju / Sit e: in the laboratory Področje preskušanja glede na vrsto preskušanca: gradbeni proizvodi, in / Testing fields with reference to the type of test item: products, and structures Oznaka a ali nene preskusne Reference to or non Naslov a ali nene preskusne in morebitne navezave na druge e ali Title of or non- and eventual relations to other s or me-thods 28. SIST EN ISO 140-4:1999 Izračun po u/ Akustika Merjenje zvočne izolirnosti v zgradbah in zvočne izolirnosti gradbenih elementov 4. del: Terenska merjenja izolirnosti med prostori pred zvokom v zraku Acoustics Measurements of sound in buildings and of buildings elements Part 4 : Field measurements of airborne sound between rooms gradbeni elementi in elements, and structures 29. SIST EN ISO 140-5 Izračun po u/ Akustika - Merjenje zvočne izolirnosti v stavbah in zvočne izolirnosti stavbnih elementov - 5. del: Terenska merjenja izolirnosti fasadnih elementov in fasad pred zvokom v zraku Acoustics - Measurements of sound in buildings and of buildings elements - Part 5 : Field measurements of airborne sound of façade elements and facades R' 45 spodnja meja : 1 db zgornja meja : 80 db asadni elementi in fasade façade elements and facades 30. SIST EN ISO 140-7:1999 Izračun po u/ SIST EN ISO 717-2 Akustika - Merjenje zvočne izolirnosti v zgradbah in zvočne izolirnosti gradbenih elementov - 7. del: Terenska merjenja izolirnosti medetažnih konstrukcij pred udarnim zvokom Acoustics - Measurements of sound in buildings and of buildings elements - Part 7 : Field mesasurements of impact sound of floors L n,w : spodnja meja: odvisna od residualnega hrupa 40 db lower limit: depend on residual noise 40 db medetažne floors Obr. P.F.10-001-2/2 Stran 5 od 5