Engineering Specification

Similar documents
Engineering Specification

Engineering Specification

Engineering Specification

Engineering Specification

Engineering Specification

Engineering Specification

Engineering Specification

Engineering Specification

Engineering Specification

ENGINEERING SPECIFICATIONS

Engineering Specification

Engineering Specification

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS

Engineering Specification

Engineering Specification

Engineering Specification

ENGINEERING SPECIFICATIONS

Engineering Specification

Engineering Specification

Engineering Specification

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

Installation and Service Manual. In-Floor Warming Module external desuperheater for 3rd party air source heat pumps

MACH N-407 Heat Pump Air-Cooled Chiller

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

water to water heat pumps

MAC N-407 Air-Cooled Chiller

SpaceKeeper Console (SKC)

GUIDE SPECIFICATIONS AQUARIUS ii

MAC-120HE-03 Air-Cooled Chiller

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

GT-PW (50YEW) Water-To-Water Series. WATER-TO-WATER PURON SYSTEMS SIZE 010 [10 kw]

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units

SECTION ROTARY-SCREW WATER CHILLERS

GUIDE SPECIFICATIONS AQUARIUS ii

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

Versatec Specification Catalog

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Installation Manual BCS2000/3000

Installation and Service Manual

Call us today! (800)

Indoor Air Handlers with Compressors MVS and MVW

Installation and Service Manual

Installation, Operation & Service Manual

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Installation Manual BCS 1000/1500

Installation and Service Manual

Call us today! (800)

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

INSTRUCTIONS! DO NOT DISCARD!

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Submittal. Date: September 04, Customer P.O. Number: Customer Project Number:

EarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions

Call us today! (800)

EarthLinked SCW Series Compressor Unit R-410A Quik-Start Instructions

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

C13-Series Engineering Guide

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

Installation and Service Manual

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

VertiCool Aurora Engineering Guide

NO: 9-16 DATE: 2/11/16 EMERSON CLIMATE TECHNOLOGIES WHOLESALERS -EXECUTIVES -PRODUCT MANAGERS -EMERSON TM TECHNICAL SPECIALISTS -BRANCH PERSONNEL

JH Series Installation

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

Air-Cooled Modular Split Systems. Product Data Catalog

Advance Split

AS950 REFRIGERATED SAMPLERS

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

EarthLinked SC Series Compressor Unit R-407C Quik-Start Instructions

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions

AVAILABLE WITH ENERGY SAVING ECM MOTOR

VariCool VAV Engineering Guide

Precise Temperature Control; Compact Footprint

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Pioneer Gold Controller Technical Guide

Condensing Units CUS 15-60

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

NQ Series Portable Chillers

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

INSTALLATION INSTRUCTIONS

Transcription:

Engineering Specification WH-55-H-B-*S-** High Temperature Water to Water Heat Pump 60 Hz Maritime Geothermal Ltd. P.O. Box 2555, 170 Plantation Road Petitcodiac, NB E4Z 6H4 (506) 756-8135 info@nordicghp.com www.nordicghp.com 001929SPC-03 ECO 000254 1-Sep-2017

Model Nomenclature WH 55 H B 1S CC xx Series: WH = high temperature liquid to water Revision: 01, 02 etc. Nominal Size: 55 = 042 compressor Functions: H = Heating Refrigerant: B = R134a Indoor Loop Exchanger: C = Copper coaxial Y = CuNi coaxial & piping Z = CuNi coaxial Outdoor Loop Exchanger: C = Copper coaxial Y = CuNi coaxial & piping Z = CuNi coaxial Compressor Stages: S = single stage scroll Voltage Code: 1 = 208/230-1-60VAC 2 = 208-3-60 VAC 4 = 460-3-60 VAC 5 = 575-3-60 VAC APPLICATION TABLE MODEL SIZE FUNCTION REFRIGERANT VOLTAGE COMPRESSOR STAGES OUTDOOR COIL INDOOR COIL REVISIONS WH-55 H B 1 2 4 5 S C Y Z C Y Z 03 This manual applies only to the models and revisions listed in this table. Maritime Geothermal Ltd. has a continuous improvement policy and reserves the right to modify specification data at any time without prior notice. 1-Sep-2017 Page 2 001929SPC-03

Design Features TUV listed for electrical certification 18/20ga satin galvanized case with reinforcing channel stiffeners Powder coat finish Acoustically insulated cabinet (1 and 1/2 thick) Completely insulated heat exchangers and piping Four removable access panels Refrigeration service ports located inside unit (1/4 Schrader) Swing out electrical box for unobstructed access to compressor Component layout allows easy access for service 1 Brass FPT fittings for Outdoor Loop and Indoor Loop connections Single Copeland Scroll compressor with start capacitor kit on single phase models Dual mounting system for compressor reduces noise and vibration Suction line accumulator Liquid line filter-dryer Liquid line sight glass Electronic Expansion Valve (EEV) Coaxial heat exchangers with CuNi available Refrigerant high and low pressure sensors Suction line temperature sensor Manual reset high pressure control Temperature sensors on all 4 water lines Control transformer with resettable breaker or fuse protection Advanced control board with BACNet interface for remote operation and data access including all sensor data and alarm conditions, PWM outputs (or 0-10VDC), configurable analog inputs (0-5VDC or 4-20mA) with onboard 5VDC, 12VDC and 24VDC power supplies USB port for complete data access including real-time charting, data logging, and diagnostic functionality with manual override operation 2 x 16 LCD display for control and data access; unit may be configured for standalone operation with outdoor reset functionality (requires outdoor temperature sensor accessory) Random start on power up (0-2 minutes) 24VAC output for external pump / water valve control (24VAC 500mA max) Electrical box layout and schematic diagrams Available Accessories Hydronic buffer tank with 12, 15, or 20kW of electric backup elements Circulator pump module with loop / unit isolation valves (230VAC) for ground loop applications Barbed P/T port adapters for heat pump Anti-vibration pad for under unit Compressor sound jacket Secure Start module 1 water valve (slow closing or solenoid) & wiring harness for open loop applications CuNi heat exchangers Outdoor temperature sensor with enclosure, for outdoor reset functionality Compressor current sensor 1-Sep-2017 Page 3 001929SPC-03

Design Features High and low refrigerant access ports Heavy duty cabinet, satin galvanized and powder coated Advanced control board with BACNet interface, real-time graphing and data logging Four removable access panels for easy servicing Sight glass 2x16 LCD display and 4 button control interface Heavy duty electrical components Start capacitor kit standard on all single phase models Solid core filter-dryer Electronic expansion valve for consistent superheat control High efficiency coaxial heat exchangers; copper or CuNi available Cabinet completely insulated with 1 and 1/2 acoustic insulation Swing out electrical box for easy servicing Heavy duty heat pump rated Copeland scroll compressor Powder coat finish inside and out 1 brass FPT connection ports Double grommet compressor mounting plate for low noise Suction accumulator 1-Sep-2017 Page 4 001929SPC-03

Dimensions Electrical Specifications Electrical Information FLA MCA Maximum Fuse/Breaker V-ø-Hz MIN MAX RLA LRA Max A Amps Amps Amps ga Code Power Supply Compressor In/Outdoor Circulators Other Information Minimum Wire Size 1 208/230-1-60 187 253 22.1 104 7.0 29.3 34.8 50 #8-2* 2 208-3-60 187 229 14.3 93 7.0 21.5 25.1 40 #8-3* 4 460-3-60 414 506 6.4 48 N/A 6.6 8.2 15 #14-3 5 575-3-60 518 632 5.3 38 N/A 5.5 6.8 15 #14-3 *one additional conductor required if connecting 115VAC circulators to unit. Refrigerant - R410a MODEL lb. kg WH-55 6.5 3.0 System contains POE oil. Shipping Information MODEL WEIGHT DIMENSIONS in (cm) lb. (kg) L W H WH-55 370 (168) 34 (86) 34 (86) 35 (89) Operating Temperature Limits Loop Parameter ( F) ( C) Note Indoor (water) Outdoor (water) Minimum EWT 70-110 21-43 Maximum LWT 160 71 Minimum ELT 45 7 Maximum ELT 90 32 Use formula (Outdoor ELT + 20 F) or (Outdoor ELT + 11 C). Indoor loop may require flow control. Values in this table are for rated liquid flow values. ELT - Entering Liquid Temperature, EWT - Entering Water Temperature, LWT - Leaving Water Temperature Loop Flow Rates SIZE gpm L/s WH-55 12 0.76 Pressure Drops Water as loop fluid gpm L/s OUTDOOR LOOP INDOOR LOOP psi kpa psi kpa 10 0.631 3.5 24.1 3.3 22.7 12 0.757 4.0 27.6 3.8 26.2 14 0.883 4.9 33.8 4.7 32.4 1-Sep-2017 Page 5 001929SPC-03

Performance Tables 120 F (49 C) Output WH-55-H R134a 60 Hz Source Data (Outdoor Loop) Water Power / Efficiency Sink Data (Indoor Loop) Water ELT Evap. Cond. Flow LLT Delta T HAB Effective COPh EWT Temp Temp. Flow LWT Delta T Output F F gpm F F Btu/hr Watts Amps W/W F F gpm F F Btu/hr C C L/s C C Watts C C L/s C C Watts 50.0 41 12.0 47.1 2.9 17,134 2,229 16.3 3.22 116.0 128 12.0 120.1 4.1 24,523 10.0 5.0 0.757 8.4 1.6 5,020 46.7 53.1 0.757 48.9 2.3 7,185 60.0 49 12.0 56.3 3.7 22,189 2,172 16.2 3.96 115.1 128 12.0 120.0 4.9 29,383 15.6 9.4 0.757 13.5 2.1 6,501 46.2 53.4 0.757 48.9 2.7 8,609 70.0 57 12.0 65.5 4.5 27,256 2,133 16.2 4.71 114.3 129 12.0 120.0 5.7 34,317 21.1 13.9 0.757 18.6 2.5 7,986 45.7 54.0 0.757 48.9 3.2 10,055 80.0 65.5 12.0 74.5 5.5 33,165 2,174 16.2 5.44 113.1 131 12.0 119.8 6.7 40,367 26.7 18.6 0.757 23.6 3.1 9,717 45.1 54.9 0.757 48.8 3.7 11,827 90.0 74 12.0 83.2 6.8 40,591 2,381 16.1 5.97 112.0 133 12.0 120.1 8.1 48,498 32.2 23.3 0.757 28.5 3.8 11,893 44.4 55.9 0.757 48.9 4.5 14,210 140 F (60 C) Output 50.0 41 12.0 47.6 2.4 14,515 2,725 22.4 2.54 136.0 147 12.0 139.9 3.9 23,599 10.0 5.0 0.757 8.7 1.3 4,253 57.8 64.0 0.757 60.0 2.2 6,914 60.0 49.2 12.0 56.8 3.2 19,363 2,641 22.5 3.12 135.3 148 12.0 140.0 4.7 28,159 15.6 9.6 0.757 13.8 1.8 5,673 57.4 64.7 0.757 60.0 2.6 8,251 70.0 57.5 12.0 66.0 4.0 23,871 2,671 22.5 3.59 134.7 150 12.0 140.2 5.5 32,770 21.1 14.2 0.757 18.9 2.2 6,994 57.1 65.3 0.757 60.1 3.0 9,602 80.0 66.7 12.0 75.1 4.9 29,310 2,797 22.5 4.05 133.4 151 12.0 139.8 6.4 38,639 26.7 19.3 0.757 24.0 2.7 8,588 56.3 66.2 0.757 59.9 3.6 11,321 90.0 76 12.0 83.9 6.1 36,600 2,993 22.4 4.56 132.1 153 12.0 139.9 7.8 46,597 32.2 24.4 0.757 28.8 3.4 10,724 55.6 67.1 0.757 59.9 4.3 13,653 160 F (71 C) Output 50.0 42 12.0 47.9 2.1 12,446 3,044 30.2 2.18 156.2 165 12.0 160.0 3.8 22,617 10.0 5.6 0.757 8.8 1.2 3,647 69.0 73.9 0.757 71.1 2.1 6,627 60.0 50.5 12.0 57.3 2.7 16,188 3,142 29.9 2.49 155.2 165 12.0 159.7 4.5 26,692 15.6 10.3 0.757 14.1 1.5 4,743 68.4 74.1 0.757 70.9 2.5 7,821 70.0 59 12.0 66.6 3.4 20,261 3,247 29.5 2.81 154.2 166 12.0 159.4 5.2 31,124 21.1 15.0 0.757 19.2 1.9 5,936 67.9 74.3 0.757 70.8 2.9 9,119 80.0 67.7 12.0 75.7 4.3 25,590 3,342 29.0 3.22 153.2 166 12.0 159.3 6.1 36,778 26.7 19.8 0.757 24.3 2.4 7,498 67.3 74.5 0.757 70.7 3.4 10,776 90.0 76.5 12.0 84.6 5.4 32,497 3,532 28.6 3.68 152.1 167 12.0 159.5 7.4 44,335 32.2 24.7 0.757 29.2 3.0 9,522 66.7 74.9 0.757 70.8 4.1 12,990 Compressor: ZR42K5E-PFV (230-1-60) 1-Sep-2017 Page 6 001929SPC-03

Wiring Diagram (208/230-1-60) 1-Sep-2017 Page 7 001929SPC-03

Electrical Box Layout (208/230-1-60) 1-Sep-2017 Page 8 001929SPC-03

Wiring Diagram (208-3-60) 1-Sep-2017 Page 9 001929SPC-03

Electrical Box Layout (208-3-60) 1-Sep-2017 Page 10 001929SPC-03

Wiring Diagram (460-3-60) 1-Sep-2017 Page 11 001929SPC-03

Electrical Box Layout (460-3-60) 1-Sep-2017 Page 12 001929SPC-03

Wiring Diagram (575-3-60) 1-Sep-2017 Page 13 001929SPC-03

Electrical Box Layout (575-3-60) 1-Sep-2017 Page 14 001929SPC-03

1-Sep-2017 Page 15 001929SPC-03

BACnet Interface The BACnet interface is an MS/TP connection via RS-485 twisted pair. There is a termination jumper if required to terminate the connection. It is located just above the BACnet connector, marked as TERM on the control board. The connector on the control board is a three wire removable screw connector. The signals are as follows: A: Communications line (+) (right pin) B: Communications line (-) (middle pin) C: Ground connection (left pin) Vendor: Maritime Geothermal Ltd. Vendor ID: 260 Model Name: MGT GEN2 Control Board The following parameters can be set via the LED Display Configuration Menu or via the PC APP Configuration Page. 1) Baud rate 2) Instance number 3) MAC address The data is available regardless of the selected control method. In order to control the unit via the BACnet interface, set the Control Source to BACnet either by using the PC APP configuration page or the display menus. The following tables provide a list of the objects applicable to this model series, along with a description of each. Note that there may be other objects available that do not apply to this model. BACnet OBJECTS - CONTROL SIGNALS (READ/WRITE) Name Data Type ID Property Description SYSTEM_Y1A Binary Value BV0 Present Value Stage 1 heating mode compressor (active is on) BACnet_Units Binary Value BV9 Present Value Select the units to use for the BACnet objects Note: object names may be subject to change without prior notice. 1-Sep-2017 Page 16 001929SPC-03

BACnet OBJECTS - DATA (READ ONLY) Name Data Type ID Property Units Description LPS1 Analog Input AI6 Present Value PSIG (kpa) Low pressure value (suction pressure) HPS1 Analog Input AI7 Present Value PSIG (kpa) High pressure value (discharge pressure) EVAP1 Analog Input AI8 Present Value degf (degc) Evaporating Temperature COND1 Analog Input AI9 Setpoint Value degf (degc) Condensing Temperature Suction_Line1 Analog Input AI10 Present Value degf (degc) Suction line temperature Superheat1 Analog Input AI11 Setpoint Value degf (degc) Superheat EEV1_POS Analog Input AI12 Present Value % EEV position (% open) Outside_Temp Analog Input AI20 Present Value degf (degc) Outdoor Ambient temperature ACCESSORY O_IN Analog Input AI21 Present Value degf (degc) Outdoor IN temperature O_OUT Analog Input AI22 Present Value degf (degc) Outdoor OUT temperature I_IN Analog Input AI23 Present Value degf (degc) Indoor IN temperature I_OUT Analog Input AI24 Present Value degf (degc) Indoor OUT temperature Comp1_Current Analog Input AI0 Present Value A Compressor current draw (AI0) - ACCESSORY AI_1 Analog Input AI1 Present Value User Selectable User defined (0-5VDC or 4-20mA) AI_2 Analog Input AI2 Present Value User Selectable User defined (0-5VDC or 4-20mA) AI_3 Analog Input AI3 Present Value User Selectable User defined (0-5VDC or 4-20mA) AI_4 Analog Input AI4 Present Value User Selectable User defined (0-5VDC or 4-20mA) AI_5 Analog Input AI5 Present Value User Selectable User defined (0-5VDC or 4-20mA) PWM_IN Analog Value AV0 Present Value % PWM input (from external source) PWM1 Analog Value AV1 Present Value % PWM output value (spare) PWM2 Analog Value AV2 Present Value % PWM output value (spare) PWM3 Analog Value AV3 Present Value % OV2 - PWM or 0-10VDC for Outdoor Loop water valve PWM4 Analog Value AV4 Present Value % IV2 - PWM or 0-10VDC for Indoor Loop water valve STAGE1 Binary Output BO0 Present Value N/A Compressor contactor ICR Binary Output BO2 Present Value N/A Indoor circulator control DO_1 Binary Output BO4 Present Value N/A IV1 (for 24VAC Indoor Loop water valve) HYD_AUX Binary Output BO5 Present Value N/A Hydronic Auxiliary DO_3 Binary Output BO6 Present Value N/A Hydronic Auxiliary Only (without compressor) Indoor_Flow Binary Value BV11 Present Value N/A Indoor Loop flow switch (ACCESSORY) Phase_Monitor1 Binary Value BV12 Present Value N/A Phase Monitor (ACCESSORY) Note: available objects may be subject to change without prior notice. BACnet OBJECTS - ALARMS AND FAULTS (READ ONLY) Name Data Type ID Alarm / Fault Description LPS1 Analog Value AI6 Alarm Low pressure alarm HPS1 Analog Value AI7 Alarm High pressure alarm Indoor_Flow Binary Value BV11 Alarm Indoor Loop flow alarm Phase_Monitor1 Binary Value BV12 Alarm Phase Monitor alarm PERM_ALARMS1 Binary Value BV16 Alarm Indicates a permanent alarm LPS1 Analog Value AI6 Fault Low pressure sensor faulty or disconnected HPS1 Analog Value AI7 Fault High pressure sensor faulty or disconnected Suction_Line1 Analog Value AI10 Fault Suction line 1 temperature sensor faulty or disconnected. Outside_Temp Analog Value AI20 Fault Outside temperature sensor faulty or disconnected. O_IN Analog Value AI21 Fault Outdoor IN temperature sensor faulty or disconnected. O_OUT Analog Value AI22 Fault Outdoor OUT temperature sensor faulty or disconnected. I_IN Analog Value AI23 Fault Indoor IN temperature sensor faulty or disconnected. I_OUT Analog Value AI24 Fault Indoor OUT temperature sensor faulty or disconnected. Note: objects may be subject to change without prior notice. 1-Sep-2017 Page 17 001929SPC-03

Engineering Guide Specifications General The liquid source water-to-water heat pump shall be a single packaged high temperature heating unit. The unit shall be listed by a nationally recognized safety-testing lab (NRTL), such as ETL, TUV, UL or CSA. The unit shall be rated in accordance with applicable standards of the Air Conditioning, Heating, and Refrigeration Institute / International Standards Organization (AHRI/ISO) and/or Canadian Standards Association (CSA). The liquid source water to water heat pump unit, as manufactured by Maritime Geothermal, Petitcodiac, New Brunswick, shall be designed to operate correctly within liquid temperature ranges specified on the Minimum and Maximum Operating Temperatures page of this engineering specification document. Factory Quality Each unit shall be run tested at the factory with water circulating in both indoor and outdoor loops. Quality control system checks shall include: computerized nitrogen pressurized leak test, evacuation of refrigeration circuit to sustained vacuum, accurate system charge, detailed heating and cooling mode tests, and quality cross check all operational and test conditions to pass/fail criteria. Units tested without water flow are not acceptable. The units shall be warranted by the manufacturer against defects in materials and workmanship in accordance with the warranty section at the end of this document. Optional extended factory warranty coverage may be available. Cabinet Each unit shall be enclosed in a sheet metal cabinet. Cabinet shall be constructed of powder coated galvanized sheet metal of minimum 20 gauge. Sheet metal gauge shall be higher where structurally required. Design and construction of cabinet shall be such that it is rigid and passes the CSA/UL Loading Test requirements (200 lb roof test). All panels shall be lined with minimum 1/2 inch [12.7 mm] thick acoustic type glass fiber insulation. All insulation shall meet the fire retardant provisions of NFPA 90A. This material shall also provide acoustical benefit. The unit must have a minimum of four access panels for serviceability of the compressor compartment. Units having only one access panel to compressor/heat exchangers/expansion device/refrigerant piping shall not be acceptable. The electrical box shall have separate holes and knockouts for entrance of line voltage and low voltage control wiring. All factory-installed wiring passing through factory knockouts and openings shall be protected from sheet metal edges at openings by plastic grommets. Refrigerant Circuit All units shall contain only one sealed refrigerant circuit, containing a hermetic motor scroll compressor, Electronic Expansion Valve (EEV), coaxial heat exchangers, factory installed high and low pressure sensors, manual reset high pressure switch, service ports, liquid line filter-drier, sight glass, and suction accumulator. Compressors shall be specified for heat pump duty with internal isolation consisting of rubber vibration isolators and mounting plate with rubber vibration isolators. Compressor motors shall have internal high temperature overload protection. The water to refrigerant heat exchangers shall consist of a steel outer jacket with twisted copper inner tube, designed and certified for 600 psig [4136 kpa] working pressure on the refrigerant side and 450 psig [3108 kpa] on the water side. Heat exchangers headered together in parallel shall use a reverse-return or symmetrical arrangement on the water side and symmetrical arrangement on the refrigerant side to ensure even flow splitting. Heat exchangers shall be insulated over all of their outside surface with minimum 3/8 thick closed cell insulation. Insulation consisting of 1/8 closed-cell insulating tape shall not be acceptable. The electronic expansion valve shall be of stepper-motor rather than pulsing type, and shall provide proper superheat control over the unit s operating range with minimal deviation from superheat setpoint. Superheat shall be determined through the suction pressure-temperature method. Externally mounted pressure controlled water regulating flow valves or thermostatic expansion valves (TXV s) in place of electronic expansion valves are not acceptable. The suction accumulator shall be insulated with minimum 3/8 thick closed cell insulation to prevent condensation. The accumulator s internal oil return port shall be sized properly for the unit s operating range. To ensure proper oil return, suction accumulator shall not be oversized. 1-Sep-2017 Page 18 001929SPC-03

Piping and Connections The unit shall have one set of primary water in and water out connections. The primary connection type shall be 1 nominal female National Pipe Thread (NPT). All water connectors shall be rigidly mounted to cabinet with corrosion resistant fasteners to prevent relative movement. All water connectors shall be constructed of copper or brass material for corrosion resistance. All internal water and refrigerant piping shall be insulated with minimum 3/8 thick closed cell insulation. Insulation consisting of 1/8 closed-cell insulating tape shall not be acceptable. Electrical Controls and safety devices shall be factory wired and mounted within the unit. Controls shall include 24 volt alternating current (24VAC) activated compressor contactor, and 24VAC 100VA transformer with built in circuit breaker or fused on both primary and secondary sides. A terminal strip with screw in terminals shall be provided for field control wiring. Units shall be name-plated for use with time delay fuses or circuit breakers. Unit controls shall be 24VAC and provide heating as required by the remote thermostat or controller, or on-board controller. Unit shall provide remote fault indication to the control system via serial communications as well as provide fault messages on the front panel LCD display. Unit Control The control system shall have the following features: 1. Anti-short cycle time delay on compressor operation. Time delay shall be a minimum of 5 minutes, for both thermostat demand and safety control reset starts. An override shall be provided to disable this delay for unit commissioning and testing purposes. 2. Random compressor start delay of 0-120 seconds on unit power up to facilitate starting multiple units after a power failure. 3. Compressor shutdown for high or low refrigerant pressures, Loss of Charge (LOC), optional low flow conditions, and for optional phase protection faults on three phase models. 4. Automatic intelligent reset: unit shall automatically restart after a trip short cycle delay expires if after trip if the fault has cleared. Should a fault reoccur 3 times sequentially then permanent lockout shall occur, requiring cycling of the power to the unit in order to reset. 5. Manual reset high pressure in case of electronic board failure. 6. The low pressure shall not be monitored for the first 90 seconds after a compressor start to prevent nuisance safety trips. 7. 2 x 16 backlit Liquid Crystal Display (LCD) and four buttons provide basic configuration and data access. Unit may be configured for stand alone operation. 8. Universal Serial Bus (USB) port for full data access and diagnostic information, including manual override of all inputs and outputs, data-logging and real-time charting. Maritime Geothermal works continually to improve its products. As a result, the design and specifications of any product may be changed without notice. Please contact Maritime Geothermal at 1-506-756-8135 or visit www.nordicghp.com for latest design and specifications. Purchaser s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any commercial contract or other agreement between any parties, but are merely Maritime Geothermal s statement of opinion regarding its products. 1-Sep-2017 Page 19 001929SPC-03

LIMITED WARRANTY MARITIME GEOTHERMAL LTD. warrants that its commercial geothermal heat pumps shall be free from defects in materials and workmanship for a period of ONE (1) YEAR after the date of installation or for a period of ONE (1) YEAR AND SIXTY (60) DAYS after the date of shipment, whichever occurs first. This warranty covers all internal components of the heat pump. MARITIME GEOTHERMAL LTD. shall, at its option, repair or replace any part covered by this warranty. Defective parts shall be returned to MARITIME GEOTHERMAL LTD., transportation charges prepaid. Replacement or repaired parts and components are warranted only for the remaining portion of the original warranty period. This warranty is subject to the following conditions: 1. The geothermal heat pump must be properly installed and maintained in accordance with MARITIME GEOTHERMAL LTD. guidelines. 2. The installer must complete the Startup Record and return it to MARITIME GEOTHERMAL LTD. within 21 days of unit installation. 3. For new construction, it is the responsibility of the building or general contractor to supply temporary heat to the structure prior to occupancy. Geothermal heat pumps are designed to provide heat only to the completely finished and insulated structure. Startup of the unit shall not be scheduled prior to completion of construction and final duct installation for validation of this warranty. 4. It is the customer's responsibility to supply the proper quantity and quality of water or properly sized ground loop with adequate freeze protection. If a geothermal heat pump manufactured by MARITIME GEOTHERMAL LTD. fails to conform to this warranty, MARITIME GEOTHERMAL LTD.'s sole and exclusive liability shall be, at its option, to repair or replace any part or component which is returned by the customer during the applicable warranty period set forth above, provided that (1) MARITIME GEOTHERMAL LTD. is promptly notified in writing upon discovery by the customer that such part or component fails to conform to this warranty; (2) the customer returns such part or component to MARITIME GEOTHERMAL LTD., transportation charges prepaid, within (30) thirty days of failure, and (3) MARITIME GEOTHERMAL LTD.'s examination of such component discloses to its satisfaction that such part or component fails to conform to this warranty and the alleged defects were not caused by accident, misuse, neglect, alteration, improper installation, repair or improper testing. MARITIME GEOTHERMAL LTD. will not be responsible for any consequential damages or labour costs incurred. In additional, MARITIME GEOTHERMAL LTD. will not be responsible for the cost of replacement parts purchased from a third party. 1-Sep-2017 Page 20 001929SPC-03