PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Similar documents
S5000 Gas Monitor. GMS5000.com

ULTIMA X5000. MSAX5000.com

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8310 IR Detection of flammable gases and vapour

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Dräger Flame 2500 Flame Detection

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Flame 2100 Flame Detection

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger PEX 3000 Flammable Gas Detection

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

Dräger PIR 7000 Flammable Gas Detection

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

SUPREMATouch Modular Fire & Gas Detection System

Dräger Polytron Pulsar 2 Open Path Gas Detector

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Dräger Flame 2350 (UV&IR) Flame Detection

GAS PLUS ALARM SYSTEM

Dräger Flame 2500 (IR3) Flame Detection

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Polytron 8200 Stationary gas detector (CatEx)

MERIDIAN UNIVERSAL GAS DETECTOR

Dräger Flame 2100 (UV) Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Flame 2370 (UV&IR) Flame Detection

ESD3000IR ESD3000IR. Infrared Gas Detector

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Dräger PIR 3000 Detection of flammable gases and vapours

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

ALTAIR 5X Multigas Detector Product Specification

Dräger Polytron 7000 Fixed gas detector

OLC(T) 100 FIXED GAS DETECTOR

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

The SharpEye 40/40R (IR) Flame Detection

The SharpEye 40/40I (IR3) Flame Detection

Dräger PIR 7200 Toxic Gas Detection Transmitter

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

3M Oldham OLCT 100. Description. Fixed Gas Detector

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Model D12-IR. Digital Gas Transmitter...

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron 8000 Stationary gas detector (EC)

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Dräger Polytron 5720 IR Detection of carbon dioxide

IT S WHAT S INSIDE THAT

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

SEC Millenium Hydrocarbon Gas Detector

ESD3000 ESD200 Combustible / Toxic Gas Detector

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Certificate of Compliance

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Dräger Polytron 5100 EC Detection of toxic gases and vapors

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Operation and Maintenance Manual

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

APPLICATION DATA SHEET

Dräger Polytron 8720 IR Detection of carbon dioxide

Lamp Supply (Recommended)

Dräger PIR 7200 Detection of toxic gases and oxygen

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Certificate of Compliance

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

GS01 (wireless) Detection of flammable gases and vapours

The SharpEye 40/40I (IR3) Flame Detection

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

FUNCTIONAL SAFETY MANUAL

Dräger Polytron 5720 IR Toxic Gas Detection

ESD500. ESD500 Combustible / Toxic Gas Detector

The SharpEye 40/40M (Multi IR) Flame Detection

P R O D U C T D ATA S H E E T

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Hydrocarbon Gas Detector

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

Searchpoint Optima Plus

SERIES 47K GAS SENSOR

PrimaX Gas Transmitter Versatile Gas Detection to Meet Your Needs

PREMIER PLATINUM INFRARED GAS SENSOR

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Instructions Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL /

Dräger GS01 (wireless) Detection of flammable gases and vapours

GAS DETECTORS. When every second counts

Dräger Polytron 8100 EC Detection of toxic gases and vapors

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Searchpoint Optima Plus

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions ***

Dräger REGARD -1 Control System

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Transcription:

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions Because every life has a purpose

PrimaX IR Gas Transmitter Every feature of the SIL 2 engineered PrimaX IR Gas Transmitter is designed with reliability in mind to withstand the most challenging environmental conditions throughout the product s life. MSA s PrimaX IR Gas Transmitter offers LEL (Lower Explosive Limit) combustible gas detection through a patented PrimaX Gas Transmitter IR dual source design. A redundant IR source provides reliability and uninterrupted monitoring should a source failure occur. Furthermore, the possibility of obscurations due to rain, fog, dirt, dust, and other environmental conditions is minimized due to dual source design. In addition, optics are optimized for maximum signal, resulting in a product of extraordinary stability.

Features & Benefits Patented dual source design provides redundancy and reliable, uninterrupted performance Patented environmental guard sensor housing for fast, efficient response time Heated optics prevent condensation buildup 4 20 ma analog output User-friendly setup, calibration diagnostics, and maintenance via HART digital communication One-person calibration is easily performed using calibration cap Easy connection using aluminium or stainless steel junction box 316 stainless steel, IP 67-rated, rugged housing protects unit from environmental extremes Factory-calibrated for fast commissioning Wide temperature range of 50 C to +80 C 3 Applications OGP including platforms, refineries, drilling rigs, and compressor stations Chemical plants Fuel-loading and storage facilities Wastewater Various other industrial applications MSAsafety.com

Installation The PrimaX IR Gas Transmitter is designed for quick and easy installation. Stainless steel and aluminium junction boxes can be ordered pre-installed for further ease of installation and wiring. A unique environmental guard with patented clamshell design provides convenient installation in tight locations. Calibration Users may choose the most suitable calibration method for their applications. A calibration cap is placed on the unit to provide one-person calibration. Calibration cap icon-driven user interface guides users through the calibration process. Alternatively, HART (Highway Addressable Remote Transducer) output provides remote calibration capability. A HART junction box is offered for local calibration in classified areas; HART software is provided to initiate calibration from remote locations. Maintenance The PrimaX IR Gas Transmitter is designed to minimize maintenance costs without replacement of internal components. The PrimaX IR Gas Transmitter dual source design reduces potential system faults due to obscurations caused by rain, fog, dirt, etc. This monitor provides maintenance alerts as well as other fault conditions over 4 20 ma and HART outputs.

Options & Accessories Calibration cap Junction boxes Flow cap Duct-mount kit Sun shield Insect guard 5 HART calibration cover HART junction box Environmental guard tether MSAsafety.com

Specifications Description Specification Gas Types and Ranges Temperature Range Repeatability Response Times Humidity Sensor Warranty Power Input Current Draw Wiring Requirements Signal Output Sensor Physical Characteristics Approval Ratings without environmental guard with environmental guard Weight Dimensions Hydrocarbon gases & vapors; 0 100 % LEL The PrimaX IR Detector is ATEX performance approved to following gases: Methane, Propane, Toluene, n-butane, n-pentane, n-hexane, Propylene, Ethane, Propylene Oxide, Acetone, Cyclopentane, Ethyl Acetate, IsoButane and is shipped from the factory set and calibrated to one of these gases. Most of other flammable hydrocarbon vapours are also detectable. 50 C to +80 C ( 58 F to +176 F) ±1 % full-scale ₉₀ <4 sec. Tested as per procedure in EN 60079-29-1. For 50 % LEL, 50% response <12 sec., 90 % response <25 sec. 0 % 95 % RH, non-condensing 10 years for IR source 18 32 VDC, 5 watts ( 50 C to +80 C) 350 ma RMS average @ 24 VDC 3-wire, 2.0 mm max (14 AWG) 4 20 ma 3-wire current source with HART protocol 316 stainless steel 1.5 kg (3.3 lbs.) 89 x 203 mm (3.5 dia. x 8 long) Europe/International EN 60079-0:2009, EN 60079-1:2007 IEC 60079-31:2009 EN 60079-29-1:2007, EN 50271:2010 CE EMC Directive: 2014/30/EU II 2 G Ex d IIC T4 Gb II 2 D Ex tb IIIC T130 Db IP67 US and Canada cfmus Class I, Div.1, Groups A, B, C, & D Class II, Div.1, Groups E, F, & G Class III ANSI/ISA 12.13.01 CSA C22.2 No. 152 Combustible Gas Performance IEC China Ex/CMC/CCCF Russia Ex/EAC (Tamb 50 C to +80 C) Ingress Protection IP67 Source Redundancy 100 % redundancy with failure of 1st source HART Compatibility with HART 7.0 Safety Integrity Level SIL 2 Your direct contact Great Britain Hopton Park, Devizes Wiltshire, SN10 2JP United Kingdom Phone +44 (0)800 066 2222 info.gb@msasafety.com For contact details of your local MSA affiliate, please visit our website. Subject to change without notice ID 07-715.2 UK/03 MSAsafety.com