Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Similar documents
R22 air-cooled modular chiller 50Hz unit. Content

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

[U] Serie MOV. Manual de Ingeniería

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

1 General information

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode

Modular Air Cooled Scroll Chillers

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

MODULAR CHILLER. R410a R22

Air Cooled Scroll Chiller

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45

MANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30

Content. The specifications, designs, and information in this book are subject to change without notice for product improvement.

Air Cooled Scroll Chiller / Heat Pump

Modular Water Cooled Water Chiller

Floor-Standing Type(E Series)

3 0 H X C A - H P 2

MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw)

High COP. Water-Cooled Screw Chiller

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Aqua Mini Full DC Inverter Unitary Chiller 50Hz. Content

Air-cooled modular Chiller. Nick Technical Engineer

1. Product Lineup. 2. External Appearance. 3. Nomenclature M R C 36 H W N1 - R. Power supply R: 380~415V 3Ph~ 50Hz. Refrigerant type N1: R410A

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

SWIMMING POOL HEAT PUMPS

Scroll Water Cooled Chiller

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

DAIKIN Modular Inverter Air Cooled Chiller

Screw Water Cooled Chiller SCW210

Shandong Vicot Air Conditioning Co.,Ltd. Modular&Packaged Air Cooled Water Chiller. Shandong Vicot Air Conditioning Co.,Ltd.

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

HEAT PUMP & HEAT PUMP & SOLAR HYBRID SOLAR HYBRID AIR CONDITIONER AIR CONDITIONER

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application

AQUASNAP JUNIOR 30RHV

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

RESIDENTIAL HIGH TEMPERATURE WATER SOURCE HEAT PUMP WATER HEATER

Koolman Air-Coolded Water Chiller With Heat Pump Option

DC Inverter Multi-split System Technical Manual - 50Hz/R410a

COMMERCIAL AIR CONDITIONERS. Aqua Mini Chiller 50/60Hz

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

[U] Serie MHB / MHA Manual de Ingeniería

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

Water Chiller Solutions. A solution to every water cooling need.

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Mini unitary chiller. Mini unitary chiller

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

Water cooled VRV IV W-series

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

HEAT PUMP. Dongguan New Times New Energy Science & Technology Co., Ltd.

MAC N-407 Air-Cooled Chiller

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

Condensing Units & Air Handlers

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

MACH N-407 Heat Pump Air-Cooled Chiller

HERO SERIES-DC INVERTER HEAT PUMPS

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

MODELS LIST. Nominal Capacity RT

MAC-A R410A Series Air cooled Modular Chiller

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

WATE R -C OOLE D WATE R C H ILLE R S

DC Inverter Multi-split System Technical Manual - 50Hz/R410a

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

inverter mini chiller

30HXC Nominal cooling capacity kw

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

EVI Scroll Air To Water Heat Pumps

Midea Precision Air Conditioner Technical Manual (Down delivery series)

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

Call us today! (800)

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

SCA 620C AIR COOLED SCREW CHILLER

DC inverter Outdoor-air Processing unit (GC )

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-to-Water Heat Pump

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Line Introduction. Karl Zhang Technical support engineer

Inverter Hot Water Heat Pumps

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Air-Cooled Condensing Units with Compact Screw Compressors

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

PRODUCT GUIDE

Midea Air Conditioners Chiller System

Air-water heat pump. Hydronic terminals. HYDROLution NEW 172 SINGLE HT 176 DUAL HT 178 MINI CHILLER 180 MODULAR CHILLER 182 WARM COIL 184 FAN COIL 186

.2 Section Waste Management and Disposal.

VariCool VAV Engineering Guide

Transcription:

Product Data 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Introduction Air-cooled modular chiller is a kind of central airconditioning unit which adopts air as the cooling (or heating) source and water as cooling (or heating) heat exchange medium. As a sort of integrated equipment, it no needs cooling tower, cooling water pump, boiler and corresponding auxiliary parts for the condenser, which makes system more simple to install and convenient maintenance, saves energy and installation space, thus it is very suitable for the regions that are short of water. SSI 30RQ Air-cooled modular chillers are designed and produced on the basement of sufficiently absorbing the top technology in AC areas, adopting high quality self-control components which are made by world famous producers. Moreover, after improvement, units can run more efficiently and more stably. 30kW module adopts independent unit frame, 65kW module consists of two units and 130kWmodule consists of four, and also several modules can be formed into an integrated unit by connecting each module s inlet & outlet pipeline in parallel. The whole unit consists of 2-32 modules (For 130module max.16 units) and the max capacity can be achieved to 2080kW. SSI 30RQ Air-cooled modular chillers can be widely applied to civilian projects and industrial projects, such as office, hotel, villa, restaurant, hospital, factory, etc. It is a wide choice. Features/Benefits Modular design, flexible combination, more convenient for installation and transportation. The unit adopts modular design, which can make more units connect together. The unit can combine 16 numbers of 130 module at most. Meanwhile every separate module can operate as main unit, also each module can be a slave unit with modules combination, more convenient for design and installation. The maximum combination of the system consists of 1 main unit and 31 slave units, for 130 module combine 15 slave units at most.

Chilled water outlet temperature adjustable. Chilled water Inlet temperature can be adjusted by wired controller according to customer s demand. In cooling mode, the adjustable range from 9-25. Easy connection between main master unit and slave units. Back up function When unit is failure If master unit fails, all the units will stop. If one slave unit fails, this unit will stop but the others will keep running. When the master unit fails, any of the slave one can be set as the master unit by manual setting. When unit is under protection If master unit s protection occurs, this system will stop. If slave unit s protection occurs, this unit will stop but the others will keep running. Compact structure, no need cooling tower, which reducing installation cost. System will be more reliable with new type efficient heat exchanger Evaporator adopts tube-in-shell heat exchanger, higher reliability and efficiency, lower requirement of the water quality. Environmental care Both R22 and ecological refrigerant R410A for choice meet different requirement. Chlorine-free and environmental friendly refrigerant, zero ozone depletion potential. High density refrigerant, therefore, less refrigerant required. Leak-tight refrigerant circuit, Brazed refrigerant connections for increased leak-tightness. Economical operation New design adopts electronic expansion valve precise refrigerant control in wider range. Electronic expansion valve allows operation at lower condensing pressure, adjustment can be made fast linear response, making the system more stable output, the indoor temperature more uniform, and enhance human comfortable. Applicable temperature range R410A, R22 Mode Cooling R407C Mode Cooling Ambient temperature range 10 C ~46 C -10 C ~21 C Ambient temperature range 20 C ~46 C -15 C ~35 C Water inlet temperature range 9 C ~25 C (12 C is default) 30 C ~48 C (40 C is default) Water inlet temperature range 9 C ~25 C (12 C is default) 25 C ~53 C (40 C is default)

Product Line Up No Model Refrigerant Dimension (mm) Weight L W H (kg) 1 30RQ30HW R22 1160 900 2090 320 2 30RQ65HW R22 2000 900 2090 570 3 30RQ130HW R22 2000 1700 2090 1100 4 30RQ30HW-410 R410A 1160 900 2090 320 5 30RQ65HW-410 R410A 2000 900 2090 570 6 30RQ130HW-410 R410A 2000 1700 2090 1100 7 30RQ30HW-407 R407C 1160 900 2090 320 8 30RQ65HW-407 R407C 2000 900 2090 570 9 30RQ130HW-407 R407C 2000 1700 2090 1100 Note: Power Supply for all units is 380V/3ph/50Hz. External Appearance 30kW 65kW 130kW

Capacity Line Up Model 30RQ30HW 30RQ65HW 30RQ130HW 30RQ30HW-410 30RQ65HW-410 30RQ130HW-410 30RQ30HW-407 30RQ65HW-407 30RQ130HW-407 Mode Compressor quantity Refrigerant Maximum combinations 1 R22 32 2 R22 32 4 R22 16 1 R410A 32 2 R410A 32 4 R410A 16 1 R407C 32 2 R407C 32 4 R407C 16

Physical data Specification for R22 Model 30RQ30HW 30RQ65HW 30RQ130HW Cooling Capacity kw 30 65 130 Capacity kw 32 69 140 Power Supply V/Ph/Hz 380V/3Ph/50Hz 380V/3Ph/50Hz 380V/3Ph/50Hz Power supply Compressor Manual switch A 100 150 250 Fuse A 50 100 200 Type Scroll Scroll Scroll Brand Copeland Copeland Copeland Model VR144KS-TFP-52E VR144KS-TFP-52E VR144KS-TFP-52E Qty. 1 2 4 Cooling kw 11.1 22 44 Cooling rated A 19 38 78 current Power Input kw 10.8 21.3 43 rated current A 18 37 76 Max. Input consumption kw 16 28 56 Max. Current A 29 51 102 Type R22 R22 R22 Refrigerant Refrigerant control EXV+ capillary EXV+ capillary EXV+ capillary Weight kg 7 6.5 2 6.2 4 Air side heat-exchanger type Finned coil pipe type Quantity of fan motor 1 2 4 Air flow volume 103m3/h 12 24 48 Condenser Fan motor model YDK550-6S01 YDK550-6S01 YDK550-6S01 (Air side) Fan motor Evaporator (Water side) rated current A 4.2 4.2 4.2 Fan motor input kw 0.911 0.911 * 2 0.911 * 4 Water side heat-exchanger type shell and tube shell and tube shell and tube Water resistance loss kpa 30 30 40 Water inlet/outlet mm DN40 DN100 DN65 diameter Water flow volume m3/hr 5.16 11.18 22.36 Max. Pressure MPa 1.1 1.1 1.1 Water pipe connection type flange connection flange connection flange connection Net(W H D) mm 1160 2090 900 2000 2090 900 2000 2090 1700 Dimension Packing size(w H D) mm 1240 2250 950 2080 2250 950 2080 2250 1740 Weight Net weight kg 320 530 960 Gross weight kg 330 545 980 Connection Power wiring mm2 No. 10mm2 3+6mm2 2 16mm2 3+10mm2 2 25mm2 3+10mm2 2 wiring Signal wiring mm2 No. (0.5~1)mm2 2 (0.5~1)mm2 2 (0.5~1)mm2 2 Control Type wired controller wired controller wired controller

Power supply protection (lack of phase, phase sequence, frequency, voltage) Chilled water pump overload protection Chiller water shortage protection Water outlet temp. protection Compressor discharge temp. protection Safety protection device Compressor low pressure protection Compressor high pressure protection Sensor malfunction protection. Compressor current input protection Fin temp. (Ambient temp.) protection Anti-frozen protection Sound level(semi-anechoic ) db(a) 62 65 68 Operation cooling 9-25 9-25 9-25 water temp. heating 30-48 30-48 30-48 Ambient temp cooling 10-46 10-46 10-46 heating -10-21 -10-21 -10-21 Remarks: Specifications are based on the following conditions: Cooling: chilled water inlet/outlet: 12 C / 7 C, and outdoor ambient temp. of 35 C DB. : warm water inlet/outlet: 40 C / 45 C, and outdoor ambient temp. 7 C DB/6 CWB. Water side fouling factor: 0.086m2 C /kw.

Physical data (Cont.) Specification for R410A Model 30RQ30HW-410 30RQ65HW-410 30RQ130HW-410 Cooling Capacity kw 30 65 130 Capacity kw 32 69 140 Power Supply V/Ph/Hz 380V/3Ph/50Hz 380V/3Ph/50Hz 380V/3Ph/50Hz Power supply Compressor Manual switch A 100 150 250 Fuse A 50 100 200 Type Scroll Scroll Scroll Brand Copeland Copeland Copeland Model ZP144KCE-TFD-522 ZP144KCE-TFD-522 ZP144KCE-TFD-522 Qty. 1 2 4 Cooling kw 11.1 22 44 Cooling rated A 19 38 78 current Power Input kw 10.8 21.3 43 rated current A 18 37 76 Max. Input consumption kw 16 28 56 Max. Current A 29 51 102 Type R410A R410A R410A Refrigerant Refrigerant control EXV+ capillary EXV+ capillary EXV+ capillary Weight kg 6.5 6.5 2 6.5 4 Air side heat-exchanger type Finned coil pipe type Quantity of fan motor 1 2 4 Air flow volume 103m3/h 12 24 48 Condenser Fan motor model YDK550-6S01 YDK550-6S01 YDK550-6S01 (Air side) Fan motor Evaporator (Water side) rated current A 4.2 4.2 4.2 Fan motor input kw 0.911 0.911 * 2 0.911 * 4 Water side heat-exchanger type shell and tube shell and tube shell and tube Water resistance loss kpa 30 30 40 Water inlet/outlet mm DN40 DN100 DN65 diameter Water flow volume m3/hr 5.16 11.18 22.36 Max. Pressure MPa 1.1 1.1 1.1 Water pipe connection type flange connection flange connection flange connection Net(W H D) mm 1160 2090 900 2000 2090 900 2000 2090 1700 Dimension Packing size(w H D) mm 1240 2250 950 2080 2250 950 2080 2250 1740 Weight Net weight kg 320 530 960 Gross weight kg 330 545 980 Connection Power wiring mm2 No. 10mm2 3+6mm2 2 16mm2 3+10mm2 2 25mm2 3+10mm2 2 wiring Signal wiring mm2 No. (0.5~1)mm2 2 (0.5~1)mm2 2 (0.5~1)mm2 2 Control Type wired controller wired controller wired controller

Power supply protection (lack of phase, phase sequence, frequency, voltage) Chilled water pump overload protection Chiller water shortage protection Water outlet temp. protection Compressor discharge temp. protection Safety protection device Compressor low pressure protection Compressor high pressure protection Sensor malfunction protection. Compressor current input protection Fin temp. (Ambient temp.) protection Anti-frozen protection Sound level(semi-anechoic ) db(a) 62 65 68 Operation cooling 9-25 9-25 9-25 water temp. heating 30-48 30-48 30-48 Ambient temp cooling 10-46 10-46 10-46 heating -10-21 -10-21 -10-21 Remarks: Specifications are based on the following conditions: Cooling: chilled water inlet/outlet: 12 C / 7 C, and outdoor ambient temp. of 35 C DB. : warm water inlet/outlet: 40 C / 45 C, and outdoor ambient temp. 7 C DB/6 CWB. Water side fouling factor: 0.086m2 C /kw.

Physical data (Cont.) Specification for R407C Model 30RQ30HW-407 30RQ65HW-407 30RQ130HW-407 Cooling Capacity kw 30 65 130 Capacity kw 35 70 140 Power Supply V/Ph/Hz 380V/3Ph/50Hz 380V/3Ph/50Hz 380V/3Ph/50Hz Power supply Compressor Manual switch A 100 150 250 Fuse A 50 100 200 Type Scroll Scroll Scroll Brand Copeland Copeland Copeland Model ZP144KCE-TFD-522 ZP144KCE-TFD-522 ZP144KCE-TFD-522 Qty. 1 2 4 Cooling kw 11 22 44 Cooling rated A 19 38 78 current Power Input kw 10.3 21.5 43 rated current A 18 37 76 Max. Input consumption kw 16 28 56 Max. Current A 38 76 155 Type R407C R407C R407C Refrigerant Refrigerant control EXV+ capillary EXV+ capillary EXV+ capillary Weight kg 6.2 6.2 2 6.2 4 Air side heat-exchanger type Finned coil pipe type Quantity of fan motor 1 2 4 Air flow volume 103m3/h 12 24 48 Condenser Fan motor model YDK550-6S01 YDK550-6S01 YDK550-6S01 (Air side) Fan motor Evaporator (Water side) rated current A 4.2 4.2 4.2 Fan motor input kw 0.911 0.911 * 2 0.911 * 4 Water side heat-exchanger type shell and tube shell and tube shell and tube Water resistance loss kpa 30 30 40 Water inlet/outlet mm DN40 DN100 DN65 diameter Water flow volume m3/hr 5.16 11.18 22.36 Max. Pressure MPa 1.1 1.1 1.1 Water pipe connection type flange connection flange connection flange connection Net(W H D) mm 1160 2090 900 2000 2090 900 2000 2090 1700 Dimension Packing size(w H D) mm 1240 2250 950 2080 2250 950 2080 2250 1740 Weight Net weight kg 320 530 960 Gross weight kg 330 545 980 Connection Power wiring mm2 No. 10mm2 3+6mm2 2 16mm2 3+10mm2 2 25mm2 3+10mm2 2 wiring Signal wiring mm2 No. (0.5~1)mm2 2 (0.5~1)mm2 2 (0.5~1)mm2 2 Control Type wired controller wired controller wired controller

Power supply protection (lack of phase, phase sequence, frequency, voltage) Chilled water pump overload protection Chiller water shortage protection Water outlet temp. protection Compressor discharge temp. protection Safety protection device Compressor low pressure protection Compressor high pressure protection Sensor malfunction protection. Compressor current input protection Fin temp. (Ambient temp.) protection Anti-frozen protection Sound level(semi-anechoic ) db(a) 62 65 68 Operation cooling 9-25 9-25 9-25 water temp. heating 25-53 25-53 25-53 Ambient temp cooling 20-46 20-46 20-46 heating -15-35 -15-35 -15-35 Remarks: Specifications are based on the following conditions: Cooling: chilled water inlet/outlet: 12 C / 7 C, and outdoor ambient temp. of 35 C DB. : warm water inlet/outlet: 40 C / 45 C, and outdoor ambient temp. 7 C DB/6 CWB. Water side fouling factor: 0.086m2 C /kw. Electrical data Model Outdoor Unit Application Power Supply Compressor OFM Hz VOL Ph Min. Max. TOCA MFA LRA RLA Qty W FLA Qty 30RQ30HW 50 380 3 342 418 29 50 110 17.6 1 550 5.06 1 30RQ65HW 50 380 3 342 418 51 100 110 17.6 2 550 5.06 2 30RQ130HW 50 380 3 342 418 102 200 110 17.6 4 550 5.06 4 30RQ30HW-410 50 380~415 3 342 457 29 50 107 19 1 550 5.06 1 30RQ65HW-410 50 380~415 3 342 457 51 100 107 19 2 550 5.06 2 30RQ130HW-410 50 380~415 3 342 457 102 200 107 19 4 550 5.06 4 30RQ30HW-407 50 380~415 3 342 418 29 50 107 19 1 550 5.06 1 30RQ65HW-407 50 380~415 3 342 418 51 100 107 19 2 550 5.06 2 30RQ130HW-407 50 380~415 3 342 418 102 200 107 19 4 550 5.06 4 Remark: TOCA: Total Over-current Amps. (A) MFA: Max. Fuse Amps. (A) LRA: Locked Rotor Amps. (A) RLA: Rated Load Amps. (A) OFM: Outdoor Fan Motor. FLA: Full Load Amps. (A) W: Rated Motor Output (W) Voltagevibrationbetween phases: <2%.

Outlook drawing 30kW (30RQ30HW, 30RQ30HW-410, 30RQ30HW-407) Rated cooling capacity( kw) A B C E F G H 30 1160 900 2090 150 460 840 850 65kW (30RQ65HW, 30RQ65HW-410, 30RQ65HW-407) Rated cooling D A B C E F G H capacity( kw) 65 2000 900 2090 386 1420 522 1586 850

130kW (30RQ130HW, 30RQ130HW-410, 30RQ130HW-407) Rated cooling D A B C E F G H capacity( kw) 130 2000 1700 2090 347 1420 510 1586 1640