Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Similar documents
Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

GAS DETECTORS. When every second counts

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

Frequently Asked Questions

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

Instructions. Duct Mount Accessory Q Rev: 11/

Instructions Det-Tronics Standard Gas Panel. 1.1 Rev: 10/

Integrating Fire and Gas Safety with Process Control Systems:

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

INSTRUCTIONS. Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH. 5.1 Rev: 4/

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Industrial Grade Gas Detection

Instructions Electrochemical Toxic Gas Detector GT3000 Series Includes Transmitter (GTX) and Sensor Module (GTS) 5.

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Fire protection in hazardous locations:

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Selecting fire and gas detectors for extreme environments:

incontrol Systems Inc. Flame and Gas Detection

Instructions FlexVu Explosion-Proof Universal Display Unit Model UD Rev: 9/

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/

Nanotechnology Metal Oxide Semiconductor (NTMOS) H 2 S Gas Sensor

Toxic Gas Detection. Model F12. Toxic Gas Detection

Instructions. Nanotechnology Metal Oxide Semiconductor (NTMOS) H 2 S Gas Detector. 2.2 Rev: 6/

Industrial Grade Gas Detection

Industrial Grade Gas Detection Detecting The Difference

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Smoke detection in hazardous areas:

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Case Study. INTEGRATING Fire & GAS SAFETY WITH PROCESS CONTROL SYSTEMS

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Global Gas Detection and Monitoring Solutions

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

FM Approved Fire & Gas Detection System

Instructions. Explosion Proof Smoke Detector U Rev: 9/

Model D12-IR. Digital Gas Transmitter...

Safety Manual. Eagle Quantum Premier SIL 2 Rated Fire & Gas System. 7.2 Rev: 8/

MSA Fixed Gas & Flame Detection for the Automotive Industry

Selecting fire and gas detectors for harsh and remote locations

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

Autronica Fire and Security AS ID:

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Instructions FlexVu Universal Display Unit Model UD10 DCU Emulator. 4.2 Rev: 9/

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Zareba Sensepoint Pro

Sieger Apex. Flexibility that meets your requirements

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Instructions. FlexVu Explosion-Proof Universal Display Unit Model UD Rev: 6/

Products and performance

INSTRUCTIONS. Duct Mount Kit Q900. Description. Operation

Model D12. Digital Gas Transmitter

ALTAIR 5X Multigas Detector

Gas safety standards are changing in 2020:

Dependable Solutions for Gas Detection

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

OLC(T) 100 FIXED GAS DETECTOR

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

MERIDIAN UNIVERSAL GAS DETECTOR

Addendum. HART Communication with the FlexSonic Acoustic Detector. 1.1 Rev: 1/

Gas safety standards are changing in 2020:

Selecting fire and gas detectors for extreme environments

Dräger Flame 2100 Flame Detection

3M Oldham OLCT 100. Description. Fixed Gas Detector

Instructions. Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL Rev: 3/

ALTAIR 5X Multigas Detector Product Specification

Instructions Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL Rev.10/

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Gas Detection in Process Industry The Practical Approach

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

S5000 Gas Monitor. GMS5000.com

Personal & Portable Gas Monitors

Instructions Dual Spectrum Infrared Flame Detector PM-5MPX. 4.1 Rev: 8/

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

MSA Gas Detection. for the Water and Wastewater Industries. Does your facility meet NFPA 820?

Safety Manual. Eagle Quantum Premier SIL 2 Rated Fire & Gas System. 9.1 Rev: 9/

GAS PLUS ALARM SYSTEM

VENTIS PRO SERIES. Product Guide

Meeting NFPA standards for

Instructions. PointWatch TM Infrared Hydrocarbon Gas Detector Model PIR Rev: 9/

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

APPLICATION DATA SHEET

ESD3000 ESD200 Combustible / Toxic Gas Detector

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

The Art of Gas Detection

Warranty Registration

Recalibrate the way you look at gas detection

Transcription:

Combustible and Toxic Gas Detection Solutions Performance and Safety Beyond Compliance

Reliable Solutions from Det-Tronics, Your Partner in Safety Trusted Response with the Utmost Confidence Our proven hazardous gas detection systems deliver the highest level of protection for people, processes and property even under the most extreme conditions. Rock-solid, performance-tested detectors for a wide variety of gas hazards all with global approvals Durable, integrated solutions for protection of people and critical industrial applications We partner with customers to design, manufacture, test and deliver complete, approved safety systems Det-Tronics leads the industry with performancetested hazardous gas detection solutions that perform optimally with minimal maintenance. Certified SIL 2 Capable solutions to streamline safety system design and provide maximum reliability Performance tested in third-party labs to validate response and accuracy Extra global approvals to ensure optimal safety and protection Multiple Layers of Detection LINE-OF-SIGHT GAS DETECTION Detect combustible gas between two points up to 120 meters apart with infrared technology POINT GAS DETECTION Detect toxic or combustible gases using electrochemical, catalytic, infrared or NTMOS technology ➊ Heated to improve operation in cold or damp environments ➋ Junction box designed to reduce installation cost ➍ ➊ ➏ ➋ FlexVu Universal Display ACOUSTIC LEAK DETECTION Detect pressurized gas leaks instantly without contact, regardless of wind direction Local display to provide confidence that you are being protected ➍ Special versions available that support easy integration with the Eagle Quantum Premier Safety System (EQP) Certified SIL 2 Capable to integrate into high availability safety systems ➐ GT3000 Electrochemical Toxic Gas Detector ➏ Approved to install without conduit seals to reduce installation cost ➐ Rugged-weather baffles for best-in-class protection HART communication for comprehensive diagnostic information ➐ ➊ ➏ ➍ ➋ Pointwatch Eclipse Infrared Hydrocarbon Gas Detector

Combustible Gas Detection Toxic Gas Detection POINTWATCH ECLIPSE INFRARED HYDROCARBON GAS DETECTOR Top selling gas detector Certified to detect methane, propane, ethylene and butane Proven infrared technology to detect and communicate gas leaks Rugged IP66/67 construction and extended interval testing reduces maintenance Faster response option available 5-year device warranty COMBUSTIBLE AND TOXIC GAS DETECTION GT3000 ELECTROCHEMICAL TOXIC GAS DETECTOR Detects hydrogen sulfide, hydrogen, oxygen, carbon monoxide, nitrogen dioxide, ammonia, chlorine and sulfur dioxide Certified SIL 2 Capable oxygen and hydrogen sulfide sensors Simple, one-person calibration CGS CATALYTIC BEAD SENSOR Best sensor for high temperature and hydrogen detection applications Cost-effective solution to detect a broad range of combustible gases Rugged, stainless steel construction Certified SIL2 capable when used with FlexVu UD10 universal display FLEXSONIC ACOUSTIC LEAK DETECTOR Detects instantly; no contact with gas required Sensitivity unaffected by wind direction or leak location Performs automatic integrity checks Works out of the box exida safety award winner FLEXVU UNIVERSAL DISPLAY Supports Det-Tronics combustible and toxic gas sensors and other 4-20 ma devices Backlit and heated LCD display Non-intrusive calibration, logging and diagnostics FLEXSIGHT LS2000 LINE-OF-SIGHT INFRARED HYDROCARBON GAS DETECTOR Easy to install and align Significantly improved alignment tolerance Third-party certified Ten-year IR source warranty; 5-year device warranty exida safety award winner POINTWATCH ECLIPSE INFRARED CARBON DIOXIDE GAS DETECTOR Quickly detects hazardous levels of carbon dioxide Tri-color LED provides local status indication and improves maintenance Proven performance 5-year device warranty

Benefit from Unparalleled Control Select from Proven Products to Meet Your Safety Needs A B C D E F G H I J K FLEXVU UNIVERSAL DISPLAY EAGLE QUANTUM PREMIER (EQP) SAFETY SYSTEM Reduces parts inventory and manpower; lowers risk Non-intrusive, one-person calibration Approved to trigger life-safety horns and alarms Loop-powered options for easy integration Combines gas and flame detection and extinguishing flame release in a single integrated solution Certified SIL 2 Capable NFPA 72 compliant Redundant, fault-tolerant loop reduces installation costs GP16 GAS PANEL ACCESSORIES Pre-configured EQP system with 16 detection inputs for combustible or toxic gas types Flexible communication options of 4/20mA and/or LON User friendly HMI touch screen and sounder on panel Including duct mounts, junction boxes, calibration kits and more Single source and application specific with highest-quality products and support COMBUSTIBLE GAS TOXIC GAS ACOUSTIC LEAK UNIVERSAL DISPLAYS Model PointWatch Eclipse CGS Catalytic Bead Sensor FlexSight LS2000 Line-of-Sight GT3000 Detected Gases Hydrocarbons (not hydrogen) Wide range of combustible gases (including hydrogen) Hydrocarbons (not hydrogen) H 2 S, CO, O 2, NH 3, CI 2, SO 2, H 2, NO 2 A Performance Certified: Outside laboratories independently validate Det-Tronics accuracy across the temperature range. B Event Historian: Most sensors maintain calibration logs and usage history. When combined with UD10, additional diagnostic information is maintained like alarm events and faults like failed calibration or loss of power. C Certified SIL 2 Capable: Det-Tronics uses exida to verify and certify the reliability of combustible gas and toxic gas detectors and displays. D Heated Sensors or Displays: A sensor covered with condensation, rain or snow cannot detect hazards. Det-Tronics detectors are heated to operate in extreme conditions. E IP Rating: Verifies that dust and water will not affect the products operation, third-party testing and ratings are provided on all products. F Analog 4-20mA: The device outputs to the most common communication method for safety systems. This method requires home run wiring topography to the controller. G HART Digital: The device allows for the use of the HART handheld maintenance tool. In addition, the GT3000, UD10 and Eclipse are FDT/DTM and AMS compatible. H Relays: The device has multiple relay outputs to drive local horns and alarms without the need to connect to a controller. I EQP/LON: The device is compatible with Det-Tronics Eagle Quantum Premier (EQP) Safety System. The EQP uses an addressable loop, which allows customers to use multidrop wiring techniques to reduce installation costs. J Digital Modbus RTU: Device outputs to an addressable loop, which allows customers to use multidrop wiring techniques to reduce installation costs. K Loop Powered: A device that uses two wires for both power and signal. Operating Temp. Range PERFORMANCE CERTIFIED EVENT HISTORIAN CERTIFIED SIL 2 CAPABLE HEATED SENSOR OR DISPLAY -55 to +75C 66/67-55 to +125C -55 to +75C 66/67-40 to +55C 66/67 Eclipse CO 2 CO 2-40 to +75C 66/67 FlexSonic Any gas -55 to +75C 66 FlexVu UD10-55 to +75C 66/67 FlexVu UD20-20 to +70C 66/67 IP RATING Additional capabilities when integrated with the FlexVu UD10 Universal Display ANALOG 4-20 ma HART DIGITAL RELAYS EQP/LON DIGITAL MODBUS RTU LOOP POWERED

The Global Leader in Fire and Gas Safety Systems QUALITY // PROTECTION // SOLUTION // FLEXIBLE // FUNCTIONAL // RELIABLE // EXPERIENCED // ENGINEERED // ADVANCED Det-Tronics offices Representative offices VdS FlexSonic Acoustic Leak Detector X3301 Multispectrum IR Flame Detector PointWatch Eclipse IR Combustible Gas Detector FlexVu Universal Display with GT3000 Toxic Gas Detector Eagle Quantum Premier Safety System 92-1066-1.6 Corporate Office 6901 West 110 th Street Minneapolis, MN 55438 USA www.det-tronics.com Phone: +1 952.941.5665 Toll-free: +1 800.765.3473 Fax: +1 952.829.8750 det-tronics@det-tronics.com All trademarks are the property of their respective owners. 2018 Detector Electronics Corporation. All rights reserved. Det-Tronics is certified to ISO 9001:2008 in all manufacturing processes.