IEI NETWORK INTERFACE MODEL TS2040

Similar documents
TECOM SYSTEMS NETWORK MASTER

P0WER SUPPLY & OUT AUX PWR INPUTS IN O O O O O O RELAYS 1-4 RELAYS 5-8

PERMACONN PM1030 Includes DI300. Installation Manual

Challenger V8 4-Way Relay Card TS0840 TECOM. Installation Guide. Revised! see Protective Earthing Addendum O O O O. Relays: Dimensions ( PCB Card )

OPERATION / INSTALLATION

Fratech Multipath-IP

Challenger Version 8 Programming Relays.

20 Light Remote Annunciator

Networked Access Control Panel. Installation Guide

Each reader connected to the Challenger LAN system is programmed as an Arming Station.

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Version 1.03 January-2002 USER S MANUAL

RCS Residential Control Systems Inc.

P2267 NETWORK INTERFACE

RTD-10 Installation Instructions

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

KT-100 Door Controller

21-light Remote Annunciator. Owner s Manual

T4000 Security Communicator

PERMACONN PM1048 v3 3G Install Manual Australia

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

SEC 2000 Millenium Infrared Gas Detector

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS


General Routing Interface

Independent Zone Control (I.Z.C.)

Installation Guide. Bacharach HGM300 to LonWorks FT-10 Communications Adapter

RS485 MODBUS Module 8AI

Product Data Sheet. Remote Terminals. Features:

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

SCR100 User Manual. Version:1.1 Date:Dec 2009

GE Security. ATS1250/ door DGP / 4-lift DGP. Installation guide

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

MD12-1 Vehicle Loop Detector

Water Source Heat Pump Module Technical Guide

UNC100 Integra Manual

Control/Communicator Installation Manual

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

HARDwired Installation/ Owner s Manual

Ethernet General Purpose

2G & 3G GSM Door Contact Alarm

2G & 3G GSM Portable PIR Alarm

Long Range Radio Alarm Transmitter

Planning Elevator Relay Groups Programming Millenium for Windows Software

ANNUNCIATOR FIXED MODULE

RMS/RPX Reader. User Manual

HRX Technical Manual. Version 1.2

OVEN INDUSTRIES, INC.

VA301C CONTROLLER WITH BACnet OPTION

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

REPEATER FS5200R INSTRUCTION MANUAL

ANC BBX-FXMNS or BBX Audio Network Controller Board Installation Instructions TNC-5000 ANC Module Mounting Locations

SC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS

Installation, Operating and Maintenance Manual

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

HRX3000. Technical Manual

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

GLOBAL. InstallatIon & operation manual

ALARM OUTPUT MODULE. Product #7736

Installation and Operation Manual. Model Q916

C-Bus Four Channel General Input Unit Installation Instructions

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

RCS Residential Control Systems Inc.

DC 60 & DM 60 displays

ZLM4 OEM Technical Manual

SMARTWALK DEMENTIA WANDERING SYSTEM

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

Interface Modules for SENTRI

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

TECHNICAL DATA OBSOLETE

SmartTerminal. Installation Commissioning & Operation. Our aim is to provide Consistently Excellent Service in the eyes of our customers MAN1536-6

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

Carbon Monoxide Transmitter

Installation Instructions Model DLC

DualCom GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

ACCURATE ELECTRONICS INC

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

D720 and D1255 Command Centers

Isolation Relay: If Needed. # 9. NO relay for TT To Thermostat NO relay. MZ308 Exquisite Heat Controller

Power Wave Zone Alarm Panel V8.5. Installation Manual

Booster Power Supply Manual

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

MD12-2 Vehicle Loop Detector

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

Instruction Manual SCD24. Read this document prior to installation. Contents

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

ORION Mini-Rep INSTALLATION MANUAL

Transcription:

IEI NETWORK INTERFACE MODEL TS2040 INSTALLATION GUIDE Revised! see Protective Earthing Addendum NOTE: This equipment must only be installed and serviced by professional qualified personnel. O O + - D+ D- - + LINE COMMS IEI O O The IEI Network Interface provides an IEI compatible line interface for reporting to a remote monitoring station on the Tecom Direct Line Network. All states, including Partial are supported. Five tone groups are supported ( Wormalds A,B,C & Chubb A,B). The IEI Network interface allows existing IEI panels to report on the Tecom Direct Line Network via an E63 concentrator. The Leader in Innovative Security Technology IEI Network Interface Model TS2040. Issue I Revision II: July 1996 1

Cover: The cover is secured by 4 M3 screws. Mounting: The TS2040 IEI Interface is supplied in a small metal enclosure which can be mounted in a convenient location. Mounting holes are provided in the base. Cable entry points are provided by a Knock-out at one end of the enclosure. An Installation kit is included with all connectors required for operation. Dimensions: 182 x 110 x 45 mm Links: TERM: GND: This termination link is fitted if the unit is the first or last device on the RS485 Sublink LAN. See LAN details on page 5. This Link connects the negative of the supply to the chassis and earth lug and should be left in. LEDs: The TS2040 is equipped with five indicator LEDs; PWR UP DN P R +12VDC power indicator. RS485 UpLink Communications to TS2030 (Link). Indicates Interface is replying to polling from the Network Concentrator Link RS485 DownLink Communications from TS2030 (Link). Indicates Interface is receiving polling data from the Network Concentrator Link IEI Poll Indicator. Indicates polling data being sent to the E63 Concentrator, or E62 Panel. IEI Response Indicator. Indicates E62 Panel responding to polling data. (Either directly, or via E63 Concentrator) When system is operating, the Poll LED will indicate a double flash followed by a double flash from the Response LED after a brief delay. Encryption: The Encryption key has been internally set to 0.. 2 TS2040IN.PM5. Issue I Revision II: July 1996

DIPSwitch Settings: Addressing: Dipswitches 1 to 4 are used to identify the IEI Network interface number: Dipswitch Number SUB-LINK UNIT No. 1 2 3 4 1 ON OFF OFF OFF 2 OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF 8 OFF OFF OFF ON 9 ON OFF OFF ON Note: Address 0 is NOT VALID for an external Sublink. (Address 0 is the Sublink number reserved for the main concentrator link) Tone Group Selection: Dipswitches 5 and 6 are used to specify the TONE GROUP used: (Normally left at default setting - both OFF) Dipswitch Number UNIT No. 5 6 Wormald A OFF OFF Wormald B ON OFF Wormald C OFF ON Chubb A OFF OFF Chubb B ON ON Concentrator / Panel Selection: Dipswitch 7 is switched ON if the interface is to communicate directly with an E62 Panel and not via an E63 concentrator. IEI Network Interface Model TS2040. Issue I Revision II: July 1996 3

Revised! see Protective Earthing Addendum SUBLINK LAN SYSTEM & EARTH CONNECTION. Another cable run to other Sublinks RS485 SUBLINK LAN + - D+ D- J12 Comms Network Concentrator LINK TS2030 470 TERM Link FITTED (1st device on LAN) "TERM" link fitted on first and last devices on the LAN. In a "star" wiring configuration the "TERM" link is only fitted on the devices at the ends of the two longest LAN cable runs. (See page 5) RS485 LAN cable Belden 8723-2pair twisted shielded data cable. * Earth System Earth + - D+ D- J2 Comms (GND link FITTED) IEI Network Interface SUBLINK TS2040 TERM Link NOT FITTED Earth (GND link FITTED) Separate Earth wire (2.5mm min.) run with LAN cable to connect all Earth terminals. Note that the Shield of each length of Data cable is only connected at one end. * Shield of Data Cable NOT connected at this end. See: LAN & Earthing Details on Page 5. * J12 Comms + - D+ D- Earth Network Concentrator SUBLINK TS2030 TERM Link FITTED (Last device on LAN) (GND link FITTED) 4 TS2040IN.PM5. Issue I Revision II: July 1996

LAN connection: The RS485 Sublink LAN is used to connect Network Concentrator Sublinks and IEI Network Interface Sublinks to a main Network Concentrator Link. Sublinks must be connected via a 2 pair twisted shielded data cable (Belden 8723 is recommended) from the LAN connection. The shield of any data cable connected to the Sublink should be connected to earth at one end only. i.e. The Link or Sublink that the other end of the data cable is connected to. It is recommended that where the distance between an IEI Network Interface Sublink and the nearest Link is more than 100 metres, a separate power supply be used to power the Sublink. To power the unit, do not connect + from the LAN. Connect '+' of the local power supply to '+' on the Interface and connect 0 volts from the power supply and 0 volts from the LAN connection to the terminal marked -. See wiring diagrams on page 4. Earthing: The earth terminals on every piece of equipment in the system must be earthed by connecting them all to one common earth point via separate Earth wire run with the LAN cable/s back to the main Network Concentrator Link. The separate Earth wire must be at least 2.5mm5. A heavier guage is recommended for runs of over 500 metres. The "GND" link must remain fitted. The Sublinks must not be connected to a local earth. This method of earthing is the only way to guarantee that the difference in earth potential between any two Network products connected to the LAN remains at an acceptable minimum. See wiring diagrams on page 4. IEI Network Interface Model TS2040. Issue I Revision II: July 1996 5

IEI INTERFACE WIRING ON 1 2 3 4 5 6 7 8 + + DIPSwitches 1-8 FINE COARSE TERM LINK EARTH LINK J4 J2 J1 J3 + - D+ D- - + LINE COMMS IEI Shield (If required) Red Black White Green RJ12 line cable Line Connection Options to E63 Concentrator. Twisted pair line cable 2.5mm Earth Wire. System Earth. Run with LAN cable. 2 Pair twisted, shielded data cable. Belden 8723 Figure 8 cable Auxiliary 12Volt supply output. 6 TS2040IN.PM5. Issue I Revision II: July 1996

Connections: J1 - IEI PWR +12 12 Volt DC supply output. 0V Power ground. Line 1 IEI line connection. 2 IEI line connection. J2 - Comms PWR +12 12 Volt DC supply input connection. 0V Power ground and LAN 0 Volt connection. COMMS D+ Positive and negative data connection of the RS485 LAN. D- Units can be up to 1.5klms from the Main Network Concentrator Link, depending on the cable used. Recommended cable is Belden 8723; 2 pair twisted, shielded, data cable. J3 - Private Line LINE 2 IEI line connection. 3 IEI line connection. J4 EARTH Earth connection. Earth wires from all pieces of equipment must be earthed at one system earth. See details on page 5. Trimpots: Coarse Fine These adjustments are factory set and MUST NOT be altered. IEI Network Interface Model TS2040. Issue I Revision II: July 1996 7

Commands Supported by TS2040 IEI Panel Interface: The TS2040 supports all of the TECOM direct-line command sets. These include the following; AN HKS AN HKSL AN HKSLP RN HKS RN HKSLP RS HKS - Activate the IEI sublink, and all of the panels attached. - Activate a downline (0 or 1) on the IEI intetface, and all of the panels on that downline. - Activate an individual IEI panel - Recall the software version from the IEI sublink. - Recall the software version of the IEI panel. - Recall the status of the IEI sublink. RS HKSL - Recall the status of the downline (0 or 1). RS HKSLP MN HKS MN HKSLP RC HKS PN HKSLP PO HKSLP - Recall the status of an IEI panel. - Set the Mapped Address of the IEI sublink and Activate it. - Set the Mapped Address of the IEI panel and Acticate it. - Recall Comm's errors on with the IEI sublink. - Point ON. Relay Control. / Closing Point Number. *See below. - Point OFF. Relay Control. / Opening Point Number. *See below. All other commands will provide data that is of no use to the user. An understanding of the TECOM direct-line HKSLP numbering systems is necessary to appreciate all of these commands. Page 11 contains a Direct Line Network block diagram which explains the numbering system. *Open / Close reporting Control: Each IEI E62 Panel connected to the TS2040, can be programmed to report Open or Close on a user defined Status number. To distinguish the Open / Close reporting control command from the standard Relay Control command, the status number is prefixed with a "1". Numbers in the range 100 to 109 may be used. Status numbers 100 to 108 may be used to program the Opening and Closing Point Status numbers, while Status number 109 is used to remove the Opening or Closing Point Status number if the facility is no longer required. e.g. To program panel 00100 to report a "Close" on Status #0/10, and an "Open" on Status #3, the following commands would be used: PN 00100 100 Report Closing on point status 0 PO 00100 103 Report Opening on point status 3 To program panel 00100 to no longer report a closing, the following command would be used: PN 00100 109 8 TS2040IN.PM5. Issue I Revision II: July 1996

IEI Panel Numbering: IEI panels are numbered from 0-9 and A-F. This numbering system has been modified for use with the TECOM Direct-Line and the TS2040. The new numbering system is as follows; IEI panel I.D TECOM I.D 0 HKS00 1 HKS01 2 HKS02 3 HKS03 4 HKS04 5 HKS05 6 HKS06 7 HKS07 8 HKS10 9 HKS11 A HKS12 B HKS13 C HKS14 D HKS15 E HKS16 F HKS17 Relay Control: The Command-Back (Relay Control) function provides a means of switching remote relays as follows; Point ON. PN HKSLP XX Point OFF. PO HKSLP XX Where XX specifies the relay to be switched (XX is the IEI relay number + 1). The relay numbers follow a straight decimal notation as follows; IEI Relay number TECOM relay number 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 A 11 B 12 C 13 D 14 E 15 F 16 IEI Network Interface Model TS2040. Issue I Revision II: July 1996 9

IEI Interface Events: The following table lists the Contact ID Event numbers reported for each of the External Alarm states. System Reset E305 00 C001 TROUBLE - System Reset. Alarm State 0 E140 00 C010 *ALARM* 10 Alarm State 1 E140 00 C001 *ALARM* 01 Alarm State 2 E140 00 C002 *ALARM* 02 Alarm State 3 E140 00 C003 *ALARM* 03 Alarm State 4 E140 00 C004 *ALARM* 04 Alarm State 5 E140 00 C005 *ALARM* 05 Alarm State 6 E140 00 C006 *ALARM* 06 Alarm State 7 E140 00 C007 *ALARM* 07 Alarm State 8 E140 00 C008 *ALARM* 08 Activate E359 00 C000 TROUBLE - Panel Activate On/Off line E357 00 C000 TROUBLE - D/L Panel Polling Exp Module E143 00 C000 TROUBLE - Exp Module Failure Power Failure E301 00 C000 TROUBLE - Mains Failure Opening E402 00 U000 OPENING Closing R402 00 U000 CLOSING 10 TS2040IN.PM5. Issue I Revision II: July 1996

NETWORK MASTER - DIRECT LINE ADDRESSING CPU CARD TECOM NETWORK MASTER LINE CARD 0 (Hwy 0) LINE CARD 1 (Hwy 1) LINE CARD 2 (Hwy 2) H K S L P Highway LINK Sub-link Line Panel Direct Line Mode. Hkslp 0???? Direct Line Mode. Hkslp 1???? Direct Line Mode. Hkslp 2???? CHALLENGER PANEL Address 0 hkslp 20000 Highway 0 Highway 1 Highway 2 CONCENTRATOR LINK. 4 Lines Address 0 hkslp 200?? # Line 0 2000? TECOM PARALLEL INTERFACE Address 1 hkslp 20001 CONCENTRATOR LINK. 4 Lines Address 0 hkslp 000?? # RS485 Sublink LAN IEI INTERFACE SUB-LINK. Address 1 hkslp 201?? Line E63 CONCENTRATOR. IEI PANEL Panel ID 1 hkslp 20101* IEI PANEL Panel ID F hkslp 20117* IEI INTERFACE SUB-LINK. Address 2 Line hkslp CHALLENGER PANEL Address 1 hk 01 Sublink, Line & Panel digits are not used. 202?? CONCENTRATOR SUB-LINK. 4 Lines Address 3 hkslp 203?? Line 0 Line 1 Line 2 Line 3 * See Page 9: IEI Panel numbering. # A Concentrator Link connected directly to the Highway is given a Sub-link Address of 0. IEI Network Interface Model TS2040. Issue I Revision II: July 1996 11

WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. The Challenger is Designed and Manufactured by: Tecom Systems Pty. Ltd. A.C.N. 005 523 562 646 Whitehorse Rd MITCHAM VIC 3132 Telephone: 03 9259 4700 Facsimile: 03 9259 4799 C Tecom Systems Pty. Ltd. 1995 Note: IEI is a trade name of I.E.I Pty. Ltd. 12 TS2040IN.PM5. Issue I Revision II: July 1996