DESCRIPTION OF COOLING TOWERS SERIES TAT

Similar documents
DESCRIPTION WATER COOLING TOWER TAS/TASF (*) SERIES

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

Series 5000 Industrial Modular Cooling Tower. Series 5000 Cooling Tower. engineering Data

CROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M)

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

What is a Closed circuit Cooling Tower (CCT)?

NEWIN Centrifual Fan Forced Draft Cooling Tower Product Introduction

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

SECTION COOLING TOWERS

SECTION COOLING TOWERS

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

FAN IMPELLERS & FAN CASINGS

Ultimate energy saving technology

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

Michigan State University Construction Standards. COOLING TOWERS Page SECTION COOLING TOWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Industrial Fans & Blowers

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

COOLING TECHNOLOGY INSTITUTE

NIBA COOLING TOWERS. Niba is established in 1993 in Istanbul, Turkey.

Ultimate energy saving technology

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Installation and maintenance manual. Open type cooling tower. Axial type. Series TAA

ULTIMATE ENERGY SAVING TECHNOLOGY

IEC- Direct-driven radial fans with IEC-Standardmotor

COMPANY PRESENTATION

Series 1500 Cooling Tower Specification

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Efficient, Long Lasting Evaporative Condensers

MARLOW PUMPS RECIRCULATION

HOMA Pump, Ansonia Connecticut

HasconWing. Fixed or variable airfoil profile axial impellers

MCV - MCH - MCHZ Multistage pumps

EXPRESSION OF INTEREST (EOI) FOR. Fire Fighting System (FFS)

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

Centeral Station Air Handling Unit

POWER TOWER SERIES Fiberglass Construction 45 to 540 Tons

CPC PRODUCT DESCRIPTION

ACN SMOKE INSTALLATION AND MAINTENANCE

Technology for life. Unit heater LH

IRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems

Baltimore Aircoil RCF CLOSED CIRCUIT COOLING TOWERS. ...because temperature matters COUNTERFLOW INDUCED DRAFT

QuadraFlow Cooling Tower

What is Cooling S.Sen

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

AZN ATEX INSTALLATION AND MAINTENANCE

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

CPF PRODUCT DESCRIPTION

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

TITLE: SPECIFICATION NO. PE-MSE-VD-ACC VOLUME:

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

A. Codes and Standards that are Standard at the University:

INFO. Stainless Steel Evaporative Cooler. The New Choice In Evaporative Cooling

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

DIVISION 15 MECHANICAL

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

E. Baffle Tray Column (or, Termed Shower Deck, No Holes, Caps, or Other Contact Devices)

Centrifugal Blower. Backward/Aerofoil Curved.

KELVIN Clim F497. Kelvin air conditioning

EVAPORATIVE COOLING, a natural occurrence

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

ANSI RAB QMS. Parag Energy Efficient Axial Flow FRP Fans

Chemical Pumps Vertical Chemical Pump Type TNP

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Axial flow fan AXICO ANTI-STALL

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

CPVS PRODUCT DESCRIPTION

Wilo IL Vertical Split-Coupled Inline Pumps

JM Aerofoil Fans Bulletin JMA60-05

Evaporative Condensers

With the world-renowned SIGMA PROFILE

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

Un-Used Series CXV Evaporative Condenser

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Vibration Of Cooling Tower Fans. Barry T. Cease Cease Industrial Consulting Vibration Institute 2015

Double Skin Casing Air Handling Units

Product Introduction...D9. Benefits...D11. Construction Details...D13. Custom Features & Options...D15. Accessories...D18. Engineering Data...

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SECTION FAN COIL UNITS

TOPAZ ADIABATIC COOLER

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

BEIER MACHINERY SRL-Z MIXING UNIT BEIER MACHINERY JIANGSU BEIER MACHINERY CO., LTD SUZHOU BESTAR BLOW MOLDING TECHNOLOGY CO.

PURESTREAM CHILL-CUBE TM BY FRIULAIR

Fa n s. Fans AF/LA Series AFT Series MAP/AVP/MF/XF Series AFH Series Centrifugal fan units OR/COR/ORV Series CNX/MXF Series ATEX Fans

Transcription:

DESCRIPTION OF COOLING TOWERS SERIES TAT The TAT series are dedicated to every industrial sector with a modular conception. These models are characterized by SCAM T.P.E. S.r.l. well defined standards and are supplied with a structure preassembled and welded in continuous with a polyurethane coating and epoxy-bituminous according to ISO 12944-5:2007. The stacks and the collecting basin are supplied with a treatment carried out on wrought carpentry SCAMBOND/STD, a protective cycle effected on wrought carpentry of polyurethane type for external surfaces and epoxybituminous for internal surfaces, according to EN ISO 12944-5:2007(E) standards. This type of towers has dimensions compatible with road and ocean transport. The ordinary maintenance is ensured by oversized ispection doors placed on every cell / fan unit. The fan units are planned for a long life and with components of utmost quality, with a very easy maintenance program. 1

FAN UNIT For TAT series of classic induced execution towers, the choice concerning the type of fan is almost obliged. The electric motor is placed inside the saturated air flow, the motor foreseen for utilization in saturated ambient, in hard working conditions. An axial fan in reinforced polypropylene (or FRP) or in aluminum alloy is placed on the same. The stacks of pyramid truncated shape allow a dynamic pressure recovery and a consequent reduction in the energy consumption. Axial fans : With multiblade solution, have the function to ensure the cooling tower with the necessary air volume. The axial fan is placed on the cell high section (levelled with the tower walk-over floor) and it is directly coupled on the motor drive shaft. The high efficiency blades are of asymmentric profile NACA aeronautic type, balanced with PALA MASTER system. All the blades are equipped with the adjustable incidence solution with still fan in order to better optimize the tower performances and the electric power consumption. The constituent materials are the galvanized steel for the hub and the 6060T5 aluminum (FRP or PPG) for the blades. Electric motors : are planned for severe conditions with continuous working type S1 asynchronous three-phase TEFC with SKF bearings type 2RSC3 with watertight oiled for life, IP55 + SCAM T.P.E. S.r.l. specifications ensuring durability. They are placed inside the flow crossing the truncated cone stacks for a better fluo-dynamic distribution. The electric motors frames are designed to transfer the dynamic loads to the cooling tower structure, minimising vibrations and allowing an easy and intuitive maintenance. All the rotating parts outside the stack are protected against accidental interferences in accordance with the most updated safety standards. Unexpected vibration switch : All the fan cells / groups are equipped with a switch cutting the motors power in case of excessive vibrations and it is contained outside the fan duct on every stack of the tower. This device is already wired to the external Junction box on which the power supply is grafted. 2

STACKS All the mechanical groups in each cooling tower cell have an high thickness steel stack with SCAMBOND/STD protection. Each stack has a circular inlet junction and a pyramidal section: the outlet section is designed to recover dynamic pressure obtaining an high efficiency of the axial fan. The stacks are fixed to the structure through dedicated bolts by securing them to the tower walk-over floor. WATER DISTRIBUTION SYSTEM Inside the cooling tower upper section is placed the distribution system of pressure type. It is composed by a main channel connected to secondary ones whereon the spray nozzles are placed to ensure a water uniform distribution upon all the dispersion section. The a.m. nozzles are of Eco type. This innovative spray nozzle has been designed to reach the following main goals: Large square water distribution (approximately 1 m2) in order to avoid any possible overlapping of the nozzles distribution on the same dispersion surface. Uniform hydraulic load in order to avoid any air bypass where the load is low and not equally supplied. Lower distance between nozzle and filling (600mm) in order to reduce the pumping elevation. Low pressure of utilization in order to reduce the pumping elevation. Self cleaning surface by means of dedicated hydraulic impeller. Anti clogging. 3

TECHNICAL DATA SHEET ECO S-L MATERIAL: DIAMETER RANGE: OPERATING PRESSURE: DISTRIBUTION: CONNECTIONS : PP from 23 to 40 mm 0,03 to 0,3 bar-g static cone + hydraulic impeller PE ADAPTOR COOLING TOWER STRUCTURE The structure is characterized by painted steel profiles with continuous welding. Stainless steel bolts and main structure solidity are the main features. This structure typology envisages the utilization of lateral cover panels realized in painted welded steel by ensuring a good aesthetical and functional maintenance of the tower over the years. LADDER AND HANDRAILS All cells of TAT SERIES are equipped with the following items, designed in accordance with the most updated safety regulations to satisfy the most demanding plant standards: Back-up frame to mechanical groups Safety handrails Access ladder to deck 4

INCLUSIONS AND EXCLUSIONS INCLUSIONS Thermal & hydraulic design. Basic design and water collecting tank loads design. Detailed calculations of the back-up structure. Internals and equipments drawing. Mechanical groups drawing. Quality Certificates. Structure. Casing. Fan Stack. Internal dispersion. Drift eliminators. Distibution system. Spray nozzles. Accessories (Vibration switches). Electric motors. Axial fans. Ladder from the basin to the tower walk-over floor (optional). Inspection doors. EXCLUSIONS Transport and installation on site. Spare parts. Water treatment equipment. Hot water piping from ground to the cooling tower (expansion joints, risers, valves). Chemical products and chlorine injection. Blow down make up connections (valves excluded). Pumps. Lightning and grounding. All that not clearly specified in the inclusions. BATTERY LIMIT Hydraulic: water inlet flanges. Electrical: IP66 terminal boxes placed on fan ducts (wired vibraswitch in the same box in order to meet one point of electric link). Instrumentation: Not wired instrumentation into dedicated JB. 5