Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Similar documents
CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

IGD.CO.UK

Two-Channel Gas Controller

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Sieger Apex. Flexibility that meets your requirements

incontrol Systems Inc. Flame and Gas Detection

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Recalibrate the way you look at gas detection

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

OLC(T) 100 FIXED GAS DETECTOR

Toxic Gas Detection. Model F12. Toxic Gas Detection

ST-IAM Sensor Transmitter Integrated Area Monitor. Check / Calibration Procedure* 10 ASH (1)

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

3M Oldham OLCT 100. Description. Fixed Gas Detector

Model D12. Digital Gas Transmitter

Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gas detecting sensor Types GDA, GDC, GDHC, GDHF, GDH

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

MGS Murco Gas Sensor EC / SC model Gas Detector and Transmitter. Installation & Operation* 08 ASH (1)

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

GAS DETECTION International Gas Detectors CH4 NO

Refrigerant Leak Detection Solutions

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Industrial Grade Gas Detection Detecting The Difference

Fixed Gas & Flame Detection International Product Range Overview

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Danfoss gas detection units

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

portable gas analyser

Monitores Personales. Personal Monitor

Warranty Registration

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Danfoss gas detection unit Type GD Heavy Duty

Frequently Asked Questions

MGD - Murco Gas detector / Monitor. Installation & Operation* 08 ASH (1)

G-TECTA TM. Portable Gas Detection Instruments

EXAMPLES OF HOW TO ORDER

APPLICATION DATA SHEET

EXAMPLES OF HOW TO ORDER

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Danfoss gas detection units

APPLICATION DATA SHEET

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

ALTAIR 5X Multigas Detector Product Specification

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Model D12-IR. Digital Gas Transmitter...

APPLICATION DATA SHEET

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

T.ex Single Gas Detector VISA

MGS-350 Gas Detector Installation and Operation Manual Instruction Revision 1 February 2013 Product Leadership Training Service

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Personal & Portable Gas Monitors

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

SP-220. Features. Combustible handheld gas leakage detector

YOUR PARTNER IN FIRE & GAS DETECTION

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Xgard. Fixed detectors For flammable, toxic or oxygen gases

P R O D U C T D ATA S H E E T

Dräger Polytron 8310 IR Detection of flammable gases and vapour

PRODUCT CATALOGUE. Gas & Air Quality Detectors Controllers Transmitters

MGD Murco Gas Detector. Check / Calibration Procedure* 10 ASH (1)

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone:

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

portable gas analyser

AT-G-SENSE Gas Sensing System

GAS DETECTOR ST400EC PART.NO

INSTALLATION AND OPERATING INSTRUCTIONS

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Installation & Operation

Global Gas Detection and Monitoring Solutions

AquiTron DATA S HEET. AT-GU Commercial Refrigerant Sensor

Carbon Monoxide CO Transmitter ADT-X3-1110

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Industrial Grade Gas Detection

Fixed Gas Detection Equipment

M2A Transmitter Operator s Manual

Danfoss Gas Sensor DGS MODBUS

SUPREMATouch. Modular Fire & Gas Detection System

Transcription:

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs Refrigerant Gases Toxic Gases Combustible Gases VOC s Legislation: F Gas Regulation, EH40 Standards: EN378 Lloyds Approval (MGD) Regulatory Approvals: UL, CE, CSA, IEC and EN

Fixed Gas Detectors MGD-MURCO GAS DETECTOR & Standard Plus 1-2 Channel Or 3-6 Channel Long-life semi-conductor sensors for detection of most halocarbon refrigerants (HFC, HCFC, CFC), ammonia, hydrocarbons, combustibles and VOC gases. Infrared sensors can detect CO2 and selected hydrocarbons Quick and easy installation of a stand-alone detector with controller s monitored by a central controller with an on-board buzzer and LED alarm indicators High/Low volt-free relays for turning on fans, alarms or connecting with BMS/SCADA systems Multi- options allows for the detection of different gases in one system The most cost effective system available select from 1 to 6 remote sensors with 1 or 2 levels of alarm Optional Relay expander box for additional relays to switch on individual sensor alarms Robust IP66 enclosure allows units to be placed directly in areas where detection is needed A scalable gas detection system for reliable real-time monitoring that alarms when pre-set thresholds are exceeded Ideal for Chiller Rooms Supermarkets Brewing Industrial Refrigeration Food Storage/Processing Technology s 230V ac. 50Hz/120V ac. 60 Hz/12V dc. 1 or 2 1 or 2 (volt free) Semiconductor + Infrared 7 (refer to back page) and can integrate into BMS IAM INTEGRATED AREA MONITOR with 1 Optional Standard Remote / Faceplate Option Long life semiconductor sensors for the detection of most halocarbon refrigerants, hydrocarbons, ammonia, VOC s and combustible gases Ideal for VRV or Air Conditioning Systems where thousands of sensors may be required A competitively priced, easy to use, stand-alone system Optional IAM C control panel allows connection of up to 16 sensors per panel which can be pyramided for system expansion. 2 volt-free relays connect to activate alarms/shut down off valves Filtered sensors and selectable delays eliminate false alarms Ideal for public areas with an optional remote sensor/faceplate Ideal for Air Conditioning Hotels Hospitals Schools Conference Rooms Theatres Office Blocks Apartments Airports Leisure Centres Shopping Malls Machinery rooms Technology s 230V ac. 120V ac. 1 (Refrigeration 1,000 ppm & Air Conditioning 10,000 ppm) 2 (volt free) 23 V dc. 1 Amp/120V ac. 1 Amp Optional (using controller) Semiconductor 1 only remote sensor/faceplate 1 (Optional) IAM-C Panel Call us today Tel: +353(1)284 6388 Just some of the more common gases that our instruments detect... Carbon Dioxide (CO2); Refrigerant Gases such as R404a, R407c, R410a, R22, R507a, R134a, R290, R600, Ammonia (NH3); Hydrocarbons (HC); Methane/Natural Gas (CH4); Ethylene (C2H4); Sulphur Dioxide (SO2); Ozone (O3); Chlorine (Cl2); Chlorine Dioxide (ClO2); Carbon Monoxide (CO); Nitrogen Dioxide (NO2); Nitric Oxide (NO); Hydrogen (H2); Hydrogen Sulphide (H2S); Hydrogen Chloride (HCl); Liquefied Petroleum Gas (LPG); Oxygen (O2)

MGS-MURCO GAS SENSOR with 3 Optional s Standard IP66 Robust Continuous monitoring of most halocarbon refrigerants (HFC, HCFC, CFC), ammonia, hydrocarbons combustible, toxic and VOC gases s to meet almost any gas detection need at the most affordable cost electrochemical for low level monitoring; infrared for fast response; semiconductor for long life For customers who want to add to an existing system, the MGS can interface with any BMS or SCADA system. User-selectable linear analogue or digital outputs provide continuous monitoring and reporting: 4-20mA, 0-5V, 0-10V, 1-5V, 2-10V Optional stand-alone system using Murco controllers (1 to 16 channels) Robust design and remote sensor options allow sensors to be placed directly in areas where detection is needed Available in a variety of housings including IP66 and duct mount for placement in the toughest of environments Ideal for Commercial/Industrial Refrigeration Chiller & Plant Rooms Supermarkets Underground Car Parks Boiler & Machinery Rooms Food Ripening/Storage Processing Hospitals Schools Chemical Storage Rooms Greenhouses Water/Waste Treatment Technology s 12/24V dc./ac. 50/60Hz 1 (using controller) but also field programmable 1 (volt free) Optional (using controller) Semiconductor + Infrared + Electrochemical 7 (refer to back page) Optional (3) or can integrate into BMS MGS MODBUS with 3 Optional s Ideal for Maintenance Facilities Schools/Universities Hospitals Garages Boiler Rooms Chiller Plants Wineries Supermarkets Food/Beverage Processing MGS-IR-RS - MGS Infrared Refrigerant (with Modbus) Can detect Carbon Dioxide (CO2) and selected hydrocarbons and refrigerant gases MGS Modbus RS485 RTU interface offers easy integration and increased connectivity Versatility of Modbus offers software control alarm delay and set points User-Selectable linear analogue and digital outputs: 4-20mA, 0-5V, 0-10V, 1-5V, 2-10V On-board alarm LED and audible alarm Digital Output; 1 relay, 1 A, 24 VAC/DC Alarm Delay; User selectable; 0, 1, 5, 10 minutes 7 Optional housings and 3 optional controllers (refer back page) MGS-IR-RS Detects the most common halocarbon refrigerants R134a, R404a, R22, R407a, R407c, R507. The Infrared sensor allows for accurate, low level detection up to 1,000 ppm. This product is only available with the standard enclosure. ST-IAM SENSOR TRANSMITTER INTEGRATED AREA MONITOR with 3 Optional s Can detect the widest range of refrigerant, toxic, combustible and VOC gases to suit most applications Linear analogue, RS485 port and digital (relay) outputs for continuous monitoring and reporting (with ST-MON 350 transmitter) Easy plug in replacement sensors reduce yearly calibration and maintenance costs Ideal for multi sensor applications requiring a high degree of monitoring and reporting Stand-alone system combining sensor and monitor 2 volt-free relays connect to activate alarms/shut off valves Relays: 2 volt free contacts that can be manually or automatically reset 3 optional control panels allows for system expansion up to 65 sensors or connects directly to most BMS, SCADA or control systems Ideal for Industrial Refrigeration Chiller & Plant Rooms Underground Car Parks Boiler & Machinery Rooms Food Ripening/Storage/Processing Chemical Storage Rooms Greenhouses Water/Waste Treatment Technology s 12/24 V ac. 12/30 V d.c. 400mA maximum 2 (low and high) 2 (volt free) 24 V dc. Optional (using controller) Catalytic + Semiconductor + Infrared + Electrochemical 7 (refer to last page) Optional (3) or integrate into BMS

Aspirated Refrigerant Leak Detectors HGM-SZ Single Zone Monitor Single Zone gas leak refrigerant monitor Proprietary infrared sensor No calibration required Measurement range of 0-10,000 ppm sensitivity to 1 ppm Provides continuous unattended monitoring Capable of detecting and measuring any CFC, HFC, HCFC or NH3 Can monitor a location up to 150 metres from display unit Displays monitored gas as well as current and peak gas levels on LCD front panel Logs up to 200 previous gas readings for analysis Ideal for Mechanical Rooms Supermarkets Manufacturing Facilities Chiller Plants Measuring Range Gases Detected Output Signal 0-10,000 ppm (HGM-SZ). NH3 is 25-10,000 ppm (AGM-SZ) CFC, HFC, HCFC Refrigerant Gases (38 pre-programmed) NH3 (AGM-SZ) 3 SPDT 3 Amp, 250 VAC rated alarm relays and 1 SPDT 3 Amp 250 VAC rated system fault relay, plus a digital display with dedicated 4-20mA DC analogue output (floating ground) HGM-MZ Multi- Zone Monitor Halogen gas monitor detects HFC, CFC, HCFC, NH3 and C02 Lowest minimum detectable limit in the industry, 1 ppm Proprietary infrared sensor Expandable to support monitoring of up to 16 remote locations Optional remote display for centralised readings Each location can be up to 355 metres from centralized display unit No calibration required Fastest sampling rate with the longest sampling distance in the industry Large graphic LCD for easy set up and real time monitoring Ideal for Mechanical Rooms Supermarkets Physical Plants Refrigeration Racks Walk-in Freezers Measuring Range Gases Detected User Interface 0-10,000 ppm (HGM-MZ); 25-10,000 ppm (AGM-MZ); 0-8,000 ppm (CO2-MZ) CFC, HFC, HCFC Refrigerant Gases (38 pre-programmed) NH3, CO2 Front panel w/3 indicator lights: Green power on; Normal Yellow fault ; Yellow Flashing system fault; Red/Flashing point has exceeded alarm set PAGM Portable Area Gas Monitor Finds leaks as small as 1 ppm Portable gas detection for refrigerant gas HFC, CFC, HCFC s and C02 Stable, accurate non-dispersive IR (NDIR) technology Data storage up to 200 readings Can locate leaks in small and hard to reach areas Fast response and clearing times The LCD Display shows concentration in real time Visual and audible alarms for preset gas concentrations and ranges Logs up to 200 previous gas readings for analysis Ideal for Supermarket maintenance Measuring Range Gases Detected 0-10,000 ppm (refrigerant gases) in 1 ppm increments Refrigerants, CFC, HFC, HCFC, CO2

Optional Control Panels to provide stand-alone gas detection systems IAM MGS ST-IAM Standard s Temperature Rating *-20 C to +50 C IAM C Allows up to 16 sensors per panel which can be pyramided for system expansion MGD (IP41) 1 or 2 Channel 3 to 6 Channel 1 or 2 alarm levels 110VAC/ 220VAC operation 4-20 ma input Extra channels can be blanked off using a resister MGS (IP41) ST-MON 350 (Modbus) The ST-MON 350 is a combined data collection, monitoring and alarm system for small refrigeration installations User friendly LCD graphic screen records temperature readings Visual and audible alarms alert if thresholds are exceeded Alarms can be monitored off site as well as on site Stored data and graphs can be retrieved by connecting to a printer, PC or modem Eliminates false alarms as sensors can be individually programmed for one or more levels of alarm with individual delays Can connect with up to 16 MGS sensors using a direct signal 4-20 ma input Can connect with up to 65 ST-IAM sensors using data protocol. IAM (IP30) ST-IAM (IP41) Optional s MGD MGS ST-IAM Temperature Rating *-40 to + 50 C IP66 (optional splashguard) IP66 with Remote head IP66 with Pressure Relief Valve A very robust enclosure for high levels of dust moisture or where condensation is present. In heavy spray or wash down areas a splashguard can be added. Similar to the IP66, but for remote areas which are difficult to access, out of eye-line or compressure enclosures. (M42 thread fitting on remote head). To monitor blow off or weeping from pressure relief valves. Normally teed off vent pipe line to exterior. IP66 with Exd Rated Remote Head IP66 Airflow Duct Mount Exd Exd To monitor hazardous areas where ATEX rating is required such as areas with flammable gases. A more cost effective sensor to the full Exd model. The enclosure is placed outside the ATEX area with the remote sensor fitted inside the area. Certified to ATEX Exd 11C T5, Zone 1, Zone 2 ( Element only). To monitor refrigerant leaks in air conditioning systems or any gas in an airflow or ducts while allowing easy access to the sensor for maintenance. It is mounted on the outside of the duct and a pitot sample tube extends into the duct. The airflow goes in one leg of the pitot up into the sensor enclosure where the sensor head lies and back out into the duct. To monitor hazardous areas where flammable gases, vapour fumes or dust are present. The enclosure is approved for Zone 1 and Zone 2. It is flame proof, explosion proof, and weather proof (ATEX, Ex d IIB+H2 T6 IP66). Designed with individually certified EXD main housing enclosure and certified Exd sensor enclosures. The final Exd Gas Monitor assemblies (main enclosure and sensor assembly) have not been certified as a complete unit. *Exceptions: Electrochemical detect from -20 C to +40 C. s can detect as low as -40 C up to 40 C for ammonia (NH3) 0-2,000 ppm only

Fixed Gas Detection Target Markets, Products, Hazards and Applications Market Products Gas Hazards Commercial Refrigeration Industrial Refrigeration Commercial Gas Detection Light Industrial / Industrial MGD IAM MGS MGS Modbus ST-IAM HGM-MZ/SZ Ammonia (NH3) Carbon Dioxide (CO2) Carbon Monoxide (CO) Combustible Gases (hydrocarbons) Formaldehyde (HCHO) Hydrogen - Combustible Gas Ethylene (C2H4) Hydrogen Sulfide (H2S) Oxygen (O2) Nitrogen Dioxide (NO2) Refrigerants Sulfur Dioxide (SO2) Chlorine Dioxide (ClO2) Chlorine (Cl2) Ozone (O3) Volatile Organic Compounds (VOC) Applications Airports Bakery Battery Charging Rooms Boiler/Machinery Rooms Brewing Chemical Storage Rooms Chiller Rooms Conference Rooms Convenient Stores Dormitories Fishing Vessels Food Distribution Centres Food Processing Fruit Ripening Greenhouses Hockey Arenas Hospitals Hotels Ice Making Plants Indoor Air Quality Laboratories Leisure Centres Loading Docks/Bays Meat Processing Plants Office Blocks Pharmecuetical Power Generation Poultry Farms Pulp and Paper Pumping Stations Shopping Malls Steel and Metal Production Supermarkets Operating Theatres Underground Car Parks Universities Vehicle Repair Shops Water / Waste Water Wineries Murco Limited, (A Bacharach Company) 114a George s St. Lower, Dun Laoghaire, Co. Dublin Tel: +353 1 284 6388 Fax: +353 1 284 6389 Email: sales@murco.ie Web: www.murcogasdetection.com QUALITY I.S. EN ISO 9001:2008 NSAI Certified HEALTH & SAFETY LEGAL COMPLIANCE EFFECTIVE COST