SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Similar documents
Installation, Operating and Maintenance Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

EXTINGUISHING AGENT RELEASE MODULE

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

FEC400 Series. Installation Manual

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Occupant Warning System

Fire / CO Alarm Interface

Application, Installation, Operation & Maintenance Manual

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Excel-EN Conventional Fire Control Panel

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

STROBE / SOUNDER INTERFACE

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

OPERATION AND INSTALLATION MANUAL

System 800 Addressable Fire Detection & Alarm System

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Control Panel Engineering and Commissioning Instructions

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

Conventional Fire Alarm System 2014 V1.2

Electric Release Panel Wiring Tips

Intelligent Security & Fire Ltd

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

FEC403EN Installation Manual

RE 102 RE Fire Alarm Control Panel. Installation, Commissioning & Operating Manual

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

An introduction to... Sigma

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

Public Safety DAS Annunciator Panel

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Intelligent addressable fire alarm control panel

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

PTE0705 Electric Fence Monitor

User Operation Manual

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

RELAY BASES & COVERS

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

ESP TECHNOLOGIES LIMITED

Addressable Loop Modules

Alarm Controller Fire and CO

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

Deaf & Hearing Impaired RadioLINK Alarm System

Owner's Manual BARFS-1 Rev 2.1. Residential Fire System

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

RELAY BASES & COVERS

Vocia VACIE. Reference Guide

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

Pioneer-R16 Gas Monitor Operator s Manual

MR-2602 Two Zone Fire Alarm Control Panel

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

Beacon 800 Gas Monitor Operator s Manual

VACIE REFERENCE GUIDE REVISION 1.2.6

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

General Routing Interface

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

Conventional Releasing Control Panel

Model 17A00 Expansion Enclosure

Model: Ei450. Instruction Manual

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

Operation and Maintenance Manual

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Fratech Multipath-IP

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

5000 INSTALLATION GUIDE

Interface Modules for SENTRI

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Precept Marine Control Panel Application Guide

FIRERAY 5000 range USER GUIDE

Scope. Warning sounders except specific requirements. Intercom Systems for Emergency Purposes. Sound Systems for Emergency Purposes

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

TECHNICAL DATA OBSOLETE

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

PERMACONN PM1030 Includes DI300. Installation Manual

Intelligent Security & Fire Ltd

MTRA-FSP Level Control Relay. Installation & Operation Manual

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

MINERVA MX. 800 Series Ancillary Equipment

ORION Mini-Rep INSTALLATION MANUAL

Transcription:

SYSTEM MANUAL FT1-SB Single Zone Fire Alarm System

DOCUMENT HISTORY Issue Date Description Written By Checked By Draft 0 2/9/2008 Original Document. A. Shenouda C. Orr Issue 1 4/11/2011 Update drawing in figure 7 A. Shenouda A. Shenouda 1

INDEX 1 INTRODUCTION... 4 1.1 Important Information... 4 1.2 System Overview... 4 1.3 Features... 5 2 OPERATION... 6 2.1 Front Display Module... 6 2.2 Termination and Control Module... 7 2.3 Power Supply... 8 2.4 FT1-SB Indications... 9 2.4.1 LED flash functions... 9 2.4.2 Buzzer Indicating Pattern... 9 2.4.3 Control Functions...10 2.4.4 Control Outputs...10 2.5 Zone Input...11 2.6 FT1-SB Specification...13 3 INSTALLATION AND COMMISSIONING...14 3.1 Installation...14 3.1.1 FT1-SB Installation...14 3.1.2 Wiring...16 3.1.3 Visual inspection...16 3.2 Commissioning...16 3.2.1 Power ON...16 3.2.2 Alarm & Fault Test (Test controls)...16 3.2.3 Actual Test...17 4 PRODUCT GUARANTEE...18 2

FIGURE LIST Figure 1 FT1-SB Display... 6 Figure 2 FT1-SB Control & Termination Module... 7 Figure 3 Din rail Power supply... 8 Figure 4 Typical Relay or Sounder Control Circuit...11 Figure 5 Zone Input Circuit...12 Figure 6 FT1-SB Block Wiring Diagram... Error! Bookmark not defined. Figure 7 Control / Termination Module & Power Supply mounting...15 Figure 8 FT1-SB Front Display typical mounting...15 TABLE LIST Table 1 FT1-SB LED Indicating Patterns... 9 Table 2 FT1-SB Buzzer Indicating Pattern... 9 Table 3 FT1-SB Control Buttons...10 Table 4 Zone Input Circuit Specifications...11 Table 5 Compatible Actuating Devices...12 Table 6 FT1-SB General Specifications...13 3

1 INTRODUCTION 1.1 Important Information The Brooks Firetracker FT1-SB is single zone conventional fire alarm panel with compatible smoke and/or heat detectors and auxiliary devices, it provides a complete single zone automatic fire detection and alarm system. FT1-SB has been designed to comply with the Australian standard AS7240.2 and for specific use in non critical switchboard applications such as main switch boards and motor control panels. FT1-SB consists of 3 basic modules: 1. Display Module, provides the user interface to control and monitor the FT1-SB system. The display module is designed to be mounted on the front door of a switch board and utilizes the standard square cut-out 90 x 90 mm in any switch board door cabinet. This provides full control of the system without needing to enter the panel and avoid exposure to live parts 2. Termination Module is housed in a DIN rail enclosure and mounted on the equipment gear tray inside the switch board cabinet. All detector termination and auxiliary outputs are available on the termination module. Only 4 wires are required to interface the front display module to the termination module allowing flexibility of mounting location within the switchboard cabinet. 3. Power supply, is a DIN rail mounted module and for installation beside the termination module. 1.2 System Overview Brooks FT1-SB is designed for those switchboard applications where fire detection is required within the switchboard cabinet itself rather than protecting the room within which the switchboard is located. The design of the system allows for the utilization of the same techniques as originally used in the switchboard design itself, i.e. standard meter case format and DIN rail mounting. The system monitors continuously the zone circuit for normal, alarm and faults (short or open circuit). The system provides alarm, fault and disable (isolate) voltage free contacts and a fully supervised 24V dc switched output to initiate external ancillary devices as well as provide an input to local system monitoring such as a building management system. FT1-SB system utilizes a non battery backed 24V dc power supply. The din rail switch mode power supply provided with the system has a wide range of mains input voltages and an adjustable 24V DC output. 4

1.3 Features The Brooks FT1-SB utilizes the leading edge technology: Microprocessor based system in both display and termination modules. Easy to install, standard meter enclosure DIN rail termination module and power supply Intuitive indication and controls, high intensity LED indicators and pushbutton switches. Transparent protective cover for the display module. Fully supervised detector circuit. One supervised alarm output limited to 0.5 Amp. Two alarm changeover relay contacts rated to 240VAC @ 5Amp and 24VDC @ 0.5Amp. Two fault changeover relay contacts. One disable (isolate) changeover relay contact. Universal AC input DIN rail switch mode power supply 240VAC / 24VDC @ 1Amp 5

2 OPERATION 2.1 Front Display Module The front display of Brooks FT1-SB is shown in Figure 1. Figure 1 FT1-SB Display The front display of FT1SB compromises indicators and controls for all system functions. The alarm zone facility is segregated and includes a separate control and LED indicator for each function, i.e. alarm test, fault test and disable (isolate). A Power ON and Common Fault indicators are provided to indicate that the mains power is applied and to identify if a system fault is present (see Table 1) FT1-SB provides a mute facility to silence the panel buzzer. Any new event, alarm or fault, will reactivate the buzzer. A reset control is also provided to reset any latched alarm or fault condition. 6

2.2 Termination and Control Module The Termination & Control Module of Brooks FT1-SB is shown in Figure 2. Figure 3 FT1-SB Termination & Control Module The control and termination module should be mounted on a DIN rail installed at a convenient location within the switchboard cabinet. The control and termination module as shown Figure 3 provides the termination point for all the field wiring. It is connected to the front display via 4 wires, 2 of these are used to supply 24V dc (0V & 24V) and the other two for communications via RS232 (Rx & Tx). 7

2.3 Power Supply Brooks FT1-SB is powered by a DIN rail switch mode power supply as shown in Figure 4 below Figure 4 Din rail Power supply Features: Universal AC input Short circuit / Overload / Over voltage Protections Can be installed on a 35mm DIN rail LED indicator for power on No load power consumption Current Range 0-1A +/-10% voltage adjustment 84% efficiency AC current consumption 0.35A @ 240V Complies with safety, EMS immunity and EMI standards 8

2.4 FT1-SB Indications The default state of the LED indicators and the buzzer is OFF if it is not defined below. 2.4.1 LED flash functions The FT1-SB LED indicators use the following flash pattern to signal the system conditions. Table 1 FT1-SB LED Indicating Patterns Indicators Pattern Function Power On Steady On Power On Zone Alarm Zone Fault Flashing Steady on Flashing Steady Alarm Test True Alarm Fault Test Open or short circuit fault Zone Disable Steady Zone outputs disabled Common Fault Steady on Memory Fault Communication Fault Monitored Output Fault Zone Fault 2.4.2 Buzzer Indicating Pattern Table 2 FT1-SB Buzzer Indicating Pattern Function Alarm Fault Mute Any Key Pattern Continuous sound Pulsing one pulse every 3 seconds One pulse only to silence the buzzer One pulse for every button pressed 9

2.4.3 Control Functions Table 3 FT1-SB Control Buttons Control Condition Description Buzzer Mute Reset Alarm Test Fault Test Disable Buzzer Off System resetting Alarm LED flashes once every second. All alarm outputs active Fault LED flashes once every second Fault relay activate Disable LED Steady on Silences the panel buzzer until a new fault or alarm occurs Reset active alarm or fault Disable active test mode. Note: If alarm or fault condition still active, the alarm or fault will re-activate Perform zone alarm test. It takes approximately 3 seconds for the alarm condition to be detected and verified before the alarm relays and buzzer become active Perform zone fault test. It takes approximately 3 seconds for the fault condition to be detected and verified before the fault relay and buzzer become active Disable all alarm or fault outputs Energise disable relay Zone alarm or fault LED remains illuminating 2.4.4 Control Outputs Non-supervised outputs The non-supervised outputs include the following. Alarm condition relay output, 2 sets of changeover voltage contacts Fault condition relay output, 2 sets of changeover voltage contacts Disable condition relay output. 1 set of changeover voltage contacts 10

Supervised Output FT1-SB provides one supervised output protected with 1 Amp fuse. External relays, sounders, or strobes, shall be connected as shown in Figure 5. Figure 5 Typical Relay or Sounder Control Circuit If the supervised output is not used, the EOL resistor shall be installed on the output terminals on the control / termination module. The EOL resistor type is 47K, 1/2W or 1W, 1%, metal film. 2.5 Zone Input The zone input specifications and compatible devices are listed in table 5 and table 6. Table 4 Zone Input Circuit Specifications Item Number of detectors per zone Number of detectors in alarm state Zone current limit Typical Zone quiescent current per zone Typical zone input resistance in alarm conditions per zone Description 0 40, including MCPs if any Up to 2 detectors including MCPs, heat and smoke detectors. 42mA 6mA 560 Ohm 11

Table 5 Compatible Actuating Devices Part No. Manufacturer Description 4350 Panasonic Conventional multi detector 4352 Panasonic Conventional photoelectric smoke detector 6295 Panasonic Conventional enclosed heat detector 60 degrees 6296 Panasonic Conventional enclosed heat detector 80 degrees 6297 Panasonic Conventional enclosed heat detector 100 degrees 6298 Panasonic Conventional enclosed heat detector 120 degrees 4318 Panasonic Conventional combination heat detector MRCSRR Menvier Red MCP complete with 470 / 680 Ohm alarm resistance. The typical zone input circuit is shown in Figure 6. Figure 6 Zone Input Circuit If a zone input is not used, an EOL resistor shall be installed. Otherwise a fault condition will always be generated. The zone EOL resistor type is 3k9, 1W, 1%, metal film. 12

2.6 FT1-SB Specification Table 6 FT1-SB General Specifications Feature Mains Power Supply Current Consumption Cable Length (between display & Term.) Operating Temperature Operating Humidity IP Rating End of Line Resistor Dimensions Specification Input 85-264V AC, 120-270VDC Output 24VDC adjustable +/- 10%. 20 Watt, 1Amp Nominal 50mA Alarm 150mA Up to 3 metres 0 C to +50 C. 5-95%, non-condensing. IP31 Detector Circuit 3k9 Supervised Output 47k Display Module - 96mm x 96mm x 72mm (H/W/D) Termination Module - 90mm x 106mm x 58mm (H/W/D) Power Supply 90mm x 22mm x 100mm (H/W/D) 13

3 INSTALLATION AND COMMISSIONING This chapter provides the CIE installation and commissioning guidelines. The installation and the commissioning of Brooks FT1-SB shall be carried out in accordance of AS3000. For detector selection and location refer AS1670.1 2004 Appendix A. The block wiring diagram of FT1-SB is shown in figure 7 EOL 3K9 DET. MCP FT1 - SB DISPLAY MODULE SUB931/931S/932 C 680 24V 0V TX RX DET. + I 24V 0V TX RX DISPLAY DETECTOR FT1 - SB CONTROL MODULE SUB930 - NO COM NC NO COM NC NO COM NC 47K CONTACT RATING 0.5A @ 24V DC CONTACT RATING 0.5A @ 24V DC CONTACT RATING 0.5A @ 24V DC 24VDC / 0.5 Amp SUPERVISED DISABLE N FAULT OUTPUTS + 240V AC A N POWER SUPPLY 24V / 1A V+ V- 24V POWER NO COM NC NO COM NC CONTACT RATING 0.5A @ 24V DC CONTACT RATING 5A @ 24VDC / 240VAC 0V ALARM OUTPUTS Figure 7 FT1-SB Block Wiring Diagram 3.1 Installation 3.1.1 FT1-SB Installation 1. The control / termination module and the power supply are designed to be rail mounted. These units can be installed at any convenient location within the switchboard cabinet and connected to the display module via 4 cores as sown in Figure 8. 2. The display module shall be mounted via a standard 90x90mm square cut out on the front door of a switch board. Please refer to the mechanical drawing of the system cabinet as shown in figure 9 3. Before the installation is complete, check and secure all the electrical connections. 14

Figure 8 Control / Termination Module & Power Supply mounting Rear Front Figure 9 FT1-SB Front Display typical mounting 15

3.1.2 Wiring The wiring of FT1-SB shall be according to the block wiring diagram shown in figure 7. 3.1.3 Visual inspection Full functional testing and visual check have been carried out in the factory before despatching the FT1SB System. Upon completion of installation and prior to applying power a visual inspection should be carried out to ensure: All detectors are connected with the correct polarity. End of Line resistor 3K9 is fitted in the last detector or MCP. Where the supervised output is used, the end of line resistor 47K is fitted as shown in Figure 5. The connection of mains power to the power supply is correctly terminated. 3.2 Commissioning 3.2.1 Power ON The Power ON Procedures shall be carried out during on-site commissioning as follow: 1. Turn ON the circuit breaker that connects mains power to FT1-SB power supply. Check that the green mains ON LED on the power supply module is illuminated. 2. On the front Display check that only the green Power ON LED is illuminated, all other LED indicators should be extinguished 3. Measure the DC voltage on the power supply output between +V and -V. The voltage shall be 24Vdc +/- 0.2V. If the voltage requires adjustment, locate the +V ADJ trim pot on the front of the power supply module and adjust until the measured voltage is within tolerance. 3.2.2 Alarm & Fault Test (Test controls) FT1-SB front display provides 3 controls; alarm test, fault test and disable. The alarm test and fault test procedures may be carried out as follow: 1. Press the alarm test control button and check: Alarm LED is flashing Buzzer is On Alarm relays energised and supervised output is active 2. Press the Silence Buzzer control, the buzzer shall stop sounding. 3. Press Disable, all alarm outputs de-activate, the alarm LED remains flashing 4. Press the Reset button, alarm relays de-energise and the alarm LED extinguishes 5. Re-Press the Disable control to re enable the system. 6. Press the fault test button and check the following: Fault LED is flashing Buzzer is On Fault relay is de-energised 7. Repeat step 2 5 for fault condition 16

3.2.3 Actual Test Alarm Test 1. Using an aerosol smoke simulation spray, spray each smoke detector in turn and check the following: Alarm LED illuminates steady Buzzer is steady On Alarm relays on the Control / Termination Module are energized Supervised alarm output is active (24V on the terminal) 2. Press Silence Buzzer control, buzzer would silence. 3. Press Reset control, alarm relays de-energise and the alarm LED extinguishes Fault Test 1. Remove the last detector in the circuit (EOL) to simulated zone open circuit and check the following: Zone fault LED and common fault LED Illuminate steady Buzzer is pulsing once every 3 seconds Fault relay on the Control / Termination Module is de-energized 2. Press Silence Buzzer control, buzzer would silence. 3. Re fit the detector, check that the fault LED remains illuminated. 4. Press Reset control, fault LED extinguishes Disable Test 1. Press disable control, ensure disable LED illuminates 2. Carry out an ALARM TEST as per 3.2.2, ensure the alarm LED illuminates but the alarm outputs do not function. 3. Carry out an FAULT TEST as per 3.2.2, ensure the fault LED illuminates but the fault outputs do not function. 4. Re press the disable control to re-enable the system. 17

4 PRODUCT GUARANTEE Brooks guarantees the FT1-SB control and indicating panel for a period of either fifteen (15) months from the date of purchase or twelve (12) months from the date of installation, whichever is the lesser. If a product has any defect due to faulty workmanship or material it will upon return to Brooks be repaired or replaced free of charge. If FT1-SB panel, any smoke/heat detectors or any other equipment supplied by Brooks should become defective within the guarantee period, it must be returned to Brooks, with proof of purchase, carefully packaged, with the problem clearly stated. Brooks shall at its discretion repair or replace the faulty unit. If returning the complete product all accessories and documentation MUST be returned. This guarantee only applies to normal conditions of use and service, and does not cover damage caused to the product or its components as a resulting from accident, neglect, misuse, unauthorized dismantling, or contamination howsoever caused, incorrect installation, careless handling or where repairs have been made or attempted by others. Onsite warranty repairs are not part of this guarantee. This guarantee excludes incidental and consequential damage. This guarantee does not cover costs associated with the removal and/or installation of equipment No other guarantees written or verbal are authorised to be made on behalf of Brooks. All other conditions and warranties whether expressed or implied are, to the extent permitted by law, hereby excluded. As Brooks has no control over the system's design, installation to the relevant Australian Standard or maintenance, the Company and its agents take no responsibility for any damage, financial loss or injury caused to any equipment, property or persons resulting from the use of the FT1-SB system Do not interfere with any components of FT1-SB system or attempt to tamper with it. This will invalidate the guarantee, but more importantly may expose the user to shock or fire hazards. This guarantee is in addition to your statutory rights as a consumer. 18

Head Office New South Wales / Australian Capitol Territory 4 Pike Street, Rydalmere. 2116 Phone: 61 (0)2 9684 1466 Facsimile: 61 (0)2 9638 7700 E-mail: sales@brooks.com.au Regional Offices Victoria / Tasmania 1/3 Molan Street, Ringwood 3134 Phone: 61 (0)3 9879 5294 Facsimile: 61 (0)3 9879 5249 E-mail: salesvic@brooks.com.au South Australian / Northern Territory 729A Port Road, Woodville, 5011 Phone: 61 (0)8 8347 0000 Facsimile: 61 (0)8 8347 0600 E-mail: salessa@brooks.com.au Queensland / Papua New Guinea 2/49 Boyland Avenue, Coopers Plains, 4108 Phone: 61 (0)7 3373 8222 Facsimile: 61 (0)7 3373 8022 E-mail: salesqld@brooks.com.au Western Australia 4 Pike Street, Rydalmere. 2116 Phone: 61 (0)2 9684 1466 Facsimile: 61 (0)2 9638 7700 E-mail: sales@brooks.com.au New Zealand Unit 106 The Zone 23 Edwin St, Mt Eden, Auckland 1024 Ph: +64 9 638 4644, Toll Free 0800 220 007 (NZ only) Fax: +64 9 638 4645 OR NATIONAL SALES NUMBER: 1300 65 8000 FOR THE COST OF A LOCAL CALL 19