Fire-fighting. TRITON Range USER MANUAL TRITON HF 12L - 24V. Version 1 07/11/17

Similar documents
Fire-fighting. PALLEON Range USER MANUAL PALLEON MOBILE. Version 1 19/10/16

Fire-fighting. PALLEON Range USER MANUAL PALLEON BP-HP. Version 2 29/11/17

The CE Marking Access to the European Market

USING AND MAINTENANCE MANUAL FOR SELF-CONTAINED POWER BRUSH MACHINE FOR CARPET AND HARD FLOOR. Elite-Silent. Elite-Silent

Concerning the use of GP4000 Series Graphic Operator Interface for applications in potentially explosive atmospheres (Zones 2/22)

Instruction Manual Captive Air Level Control. Model NLP

REFLOW OVEN FT01 Version REFLOW OVEN FT01. (Article number F31105) User s Manual

Operating Instructions for Liquid Level Transducer Model : MM Series

EN ISO/IEC :2016/AC

EG KONFORMITÄTSERKLÄRUNG EC DECLARATION AND MANUFACTURER S DECLARATION OF CONFORMITY CE DÉCLARATION DE CONFORMITÉ CE DICHIARAZIONE DI CONFORMITÀ

Operating instructions For Vibration level switch. Model NSV

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

The New National Fire-Fighting Fighting Foam Framework

CTC EcoMiniEl. Installation- and Maintenance Manual. External electric boiler. Providing sustainable energy solutions worldwide

BIOSTORE HEATING ROLL IN CABINETS SCC 1010, SCC 2320, SCC 1120, SCC 2340 TECHNICAL MANUAL INCLUDING - USER MANUAL - INSTRUCTIONS

Installation, Operation and Maintenance

LSM PUMPER Sigenvej 7 DK 9760 Vrå Tlf.: Fax USERS GUIDE FOR LSM PUMPS TYPE

AUTOMATIC VACUUM UNIT

Instruction manual

Illuminated Stopper Station Push Button

Foot control. No instrument selected. A Raise chair Chair to working position 1 B Incline backrest Chair to spitting. positioning

Hardware User s Manual

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

Tornado Operations & Maintenance Manual

manual addendum DELPHI Ex

Fire Suppression Performance of Manually Applied CAF and Other Water Based System

Hardware User s Manual

Cleaning systems custom-made for all application ranges

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Hardware User s Manual

CE Unit is suitable for material transport. The transported gas may be up to 80 C.

Wireless External Alarm

RC411 Operator Manual

OPERATING INSTRUCTIONS

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -6000C, -7500C, C. Service manual. Oxiperm 164C 4-10 kg Service en

SPRINKLER SYSTEM SOLUTIONS. Water-based Fire-Fighting Sprinkler System PROVEN TECHNOLOGY

DL/DLM. Operating instructions Manuel d instructions Instrucciones de uso

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

Switching on the pump. Measuring of PH. Aspiration of PH Down or PH up. Injection of the product. PH adjusted

Instruction manual. Water treatment Boiler system D 30 L

Tornado Operations & Maintenance Manual

Proportioners for Stationary Extinguishing Systems

Accu-Mix 500. Proportional Injector USER MANUAL

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

GLASS WASHING MACHINE INSTRUCTION MANUAL

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

Foam Products ENGLISH

Vacuum cleaner Instruction manual

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

aqua pump a PLAS-CONT company aqua pump Direct-Proportional- Injectionpumps DPI Venturipumps Spray-Systems Peristaltic Pumps ChemicalControlSystem

SAFETY FIRST INTERNATIONAL

OPERATING INSTRUCTIONS

IEC and CENELEC standards used to protect the electrical worker against an Arc Flash

Air-cooled heat pump USER MANUAL HBI IHBIFY _01

INSTRUCTION MANUAL SLIDE 865. S.E.F.A Z.I PASTABRAC ESPERAZA FRANCE Tel: 33 (0) Fax:33.(0)

NRG NRG NRG NRG

Materials Handling and Intralogistics. Industrial Trucks. In accordance with the Directive Equipment for potentially explosive atmospheres (ATEX)

P.N Rev A ELECTRIC HOT WATER DISPENSER User Manual BVSTWD7915 Series MODEL

MIXING UNITS ANS HOSES STATIONS STEAM AND COLD WATER NL-551 SERIES. 1

This document is a preview generated by EVS

Type examination certificate: INERIS 07ATEX3003X and Additions 01/02

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

WHE 2.24 / WHE 2.24 FF

Washer disinfectors. MLC Series. for transfer trolleys, sterile containers and bulky items

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Concerning the use of GP4000 Series Graphic Operator Interface for applications in potentially explosive atmospheres (Zones 2/22)

Kit Instructions COMMON VENT KIT (PVC AND DURAVENT)

SMK 22 SMK SMK SMK 22-82

Washer disinfectors. > Small - Medium range. devoted to hygiene. For the Environmentally conscious

Mounting and Operating Instructions EB 5206 EN. Thermostats. Type 5343 Safety Temperature Monitor (STM) Type 5344 Temperature Regulator (TR)

Operating Instructions

BCF1080 FORWARD PLATE COMPACTORS PARTS BOOK

Supply and installation of a gas delivery unit for Hydrogen fluoride (HF) and a vertical furnace

SOUTH AFRICAN NATIONAL STANDARD

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

An Overview Of Fluorinated Firefighting Foams: Past, Present & Future Presented by: Jerry Back, JENSEN HUGHES FOAM SYSTEM SYMPOSIUM

SuperMagnum 270 ELC Hot Water High-Pressure Cleaner

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

Datasheet Automatic Protection System for Vehicle Engine Rooms Model: BPS

USER S MANUAL ATH WH220

Firefighting Monitors Tunnels Fire Protection Systems. Integrated Fire Safety and Security Solutions

User Guide Topax Hygiene System. S Booster MP44/MP66/MP88

Proportional Injector

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

Installation and maintenance instructions

EUROPUMP ATEX Guideline Part II

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

Certificate of Compliance

User instructions DHP-AT

Glass and Dishwashers AMX / AUX Series

Single Pumps_ 2 Double Pumps _ 4. Air freshener dosing pump for air-conditioning equipments _ 7 Car Wash_ 7 Enzyme dosing pumps_ 8

Glass and Dishwashers AMX / AUX Series

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD

High Pressure Washer 130

Compact Pressure Washer 100

USERS MANUAL FOR GAS BOILERS

Transcription:

Fire-fighting TRITON Range USER MANUAL TRITON HF 12L - 24V Version 1 07/11/17

History of modifications Date Version Modification N pages modified 07/11/17 1 Creation 2

Sommary Pages General presentation... 4 Description of the system... 4 PERFORMANCES Triton HF - Flowmeter DN40... 6 List of compatible foam concentrates... 7 to 8 HYDRAULIC DRAWING Triton... 10 PRESENTATION OF THE TRITON CONTROL UNIT Intervention screen... 12 Maintenance screen... 13 Daily report screen... 14 PROCEDURE OF INTERVENTION Procedure of intervention... 16 to 19 Specific effects during the intervention... 20 PROCEDURE OF MAINTENANCE Maintenance to be accomplished... 22 Notes... 22 ANNEXES EC declaration of conformity... 24 3

General presentation Triton is a single-point pressurized injection device compliant with the requirements of EN 16327. Triton can be used with soft water or seawater. Triton is designed to be installed on fire trucks used under normal operating conditions (outdoors, tunnel, etc.). Explosive atmospheres must be avoided. Triton operates within a temperature range of - 15 C and + 60 C with a humidity level between 30 and 90%. CTD recommends the use of gloves compliant with DIN EN 659 when using a Triton device. Description of the system The output of the system Triton is 12 l/min. Triton 12L is in version low pressure. These model comply with EN 16327 classification. > Operating ranges: See operating curves in page 6. The automatic «Flushing» fonction can be provided optionally. Refer to CTD s delivery slip to find out the exact model installed on the vehicule. 4

PERFORMANCES 5

Performances Triton HF - Flowmeter DN40 TRITON HF (Low Pressure) - DZA 8 / 0,1-1 Flowmeter DN40 CONCENTRATION 0.1 % 0.5 % 1 % FLOW MINIMUM 200 50 30 MAXIMUM 850 850 850 900 800 700 600 500 400 300 200 100 0 0,1% 0,2% 0,3% 0,4% 0,5% 0,6% 0,7% 0,8% 0,9% 1,0% Standard EN 16327 Supply voltage Maximum power consumption Maximum injection pressure Electric motor power Maximum output of the foam pump Dimensions of the motor pump unit Total weight Compatible foam concentrate 24Vdc 60A 15 bar 1 Kw 12 L/min 610 mm (L) x 350 mm (l) x 280 mm (H) 50 Kg Class A (according to DIN EN 2 => See compatible foam concentrate table in page 7) 6

List of compatible foam concentrates MOUILLANT-MOUSSANT / CLASS A FABRICANT / MANUFACTURER NOM DU PRODUIT / NAME OF THE PRODUCT 3FFF Freefor 15 3FFF Freefor 21 3FFF Freefor 63 3FFF Freefor SF1 3FFF Freefor SF2 3FFF Freefor SF3 3M Light Wter FT-1150 3M Light Wter SFFF ANGUS FIRE Forexpan ANGUS FIRE FirePower Class A ANGUS FIRE Hi Combat Class A (1st Defense Class A Cold) ANSUL Silvex Class A Foam Concentrate ANSUL Ansul-A AUXQUIMIA Cafoam AUXQUIMIA Phos-Chek WD881 AUXQUIMIA Phos-Chek WD881C AUXQUIMIA First Response AUXQUIMIA Firefoam 103B AUXQUIMIA Phos-Chek Solid BIO-EX Biofor C BIO-EX Biofor N BIO-EX Biofor S CHEMGUARD Class A Plus CHEMGUARD First Class - Class A Foam P/N 5100-307 Dr STHAMER Sthamex R - Class A Dr STHAMER Sthamex-Class-A Synthetic Class A EAU & FEU M51 EAU & FEU M51+ EAU & FEU Forexpan FIRE RESPONSE SYSTEMS, INC. Class A - Fire Stop-R CCR# GOLD7386 FOMTEC Class A NATIONAL FOAM Knock-Down NATIONAL FOAM Responder ORCHIDEE Orchidex A 7

MOUILLANT-MOUSSANT / CLASS A FABRICANT / MANUFACTURER NOM DU PRODUIT / NAME OF THE PRODUCT ORCHIDEE Orchidex A Royal SOLBERG Fire-Brake UNIFOAM CO. LTD. UniA 1% VANRULLEN - UNISER Uniseral FF60* VS FOCUM Boldfoam A+ VS FOCUM Boldfoam A1 VS FOCUM Boldfoam AM VS FOCUM Boldfoam AMF 8

HYDRAULIC DRAWING 9

Hydraulic drawing Triton with flushing option 10

PRESENTATION OF TRITON CONTROL UNIT 11

Intervention screen 1 2 T1 T2 T3 T4 STARTING AND USING BUTTON T1 Button of access to the maintenance screen and priming in intervention. T2 Button for reducing the concentration percentage (mini 0.1%) T3 Button for increasing the concentration percentage (maxi 1%) T4 Button for start and stop the intervention INFORMATION DISPLAY ON THE SCREEN 1 Real time water flow 2 Concentration in % 12

Maintenance screen 1 2 T1 T2 T4 STARTING AND USING BUTTON T1 T2 T4 Button for accessing to the DAILY REPORTS Button for accessing to the SECURE MENU Button EXIT, return to the home screen INFORMATION DISPLAY ON THE SCREEN 1 Serial number of the TRITON 2 Date of the next maintenance 13

Daily report screen 1 2 3 T1 T2 T3 T4 STARTING AND USING BUTTON T1 Button «GUM» to clear the daily reports T2 Button «NEXT PAGE» T3 Button «PREVIOUS PAGE» T4 Button EXIT, return to the home screen INFORMATION DISPLAY ON THE SCREEN 1 Quantity of water used 2 Quantity of product used 3 Interventions duration 14

INTERVENTION PROCEDURE 15

Intervention procedure - TRITON powers on after switch on the battery switch. - The screen displays the current water flow and the last concentration used. - Select the concentration wanted by pressing the «+» and «-» buttons. (Possible change during the intervention) - Press «START» - Dosing begins automatically when the water flow rate is higher than 30 l/mn. Triton keep the concentration depending the water flow without any action from the users. - Check the injection pressure (Manometer of the injector), which must be greater than the discharge pressure of the water pump. - If the injection pressure is lower than the water pressure, press and hold down the «PRIMING» button until the liquid escapes from the prime tube then release. Check again the injection pressure. - At the end of the intervention press the button 16

Intervention procedure FUSHING : - Press the button «TOOLS» - Press the button «FLUSHING» - Start flushing by pressing the button «START» - When clear water flows at the spear and the priming hose, flushing is finished, press the button «STOP» Note: - You need not rinse Triton when you use a wetting or foaming agent. 17

Intervention procedure FILLING : - Press the button «TOOLS» - Press the button «FILLING» - Switch the suction valve on external. - Start filling by pressing the button «START» - To priming the system, press and hold down the «PRIMING» button. until the product escapes from the prime tube and release Filling is done When the tank is full, the filling stops automatically - If you want to stop the filling, press the «STOP» button - Exit the menu by pressing the button Flushed by selecting the button in the tool menu (see previous page) 18

Intervention procedure EXTERNAL SUCTION : During an intervention, it is possible at any time to connect to an external source product: - Connect a suction pipe to the external intake outlet and place it in a tank of product. Switch the manual valve in «EXTERNAL SUCTION» position. External suction Tank suction - The operating mode is identical to that previously described. 19

Specific effects during the intervention EFFECTS CAUSES The water flow rate value is blinking => Insufficient output If the flow rate is lower than the measuring threshold, The system does not dispense the liquid and this makes the value blink. SOLUTIONS Increase the nozzle output => The system starts dispensing again when the flow rate becomes higher than the measuring threshold. EFFETS CAUSES The water flow rate value is blinking => Excessive output If the flow rate is higher than the maximum measuring performance, the system measures out the liquid at its maximum value. The value flashes to alert the user. SOLUTIONS Reduce the nozle output or the concentration => The system starts dispensing correctly again when the flow rate falls bellow the maximum measuring value 20

MAINTENANCE PROCEDURE 21

Maintenance to be accomplished MAINTENANCE TO BE MADE EVERY 6 MONTHS : Control the level of oil inside the piston pump (Type 5W40) Clean the filter of the suction part of the pump. MAINTENANCE TO BE MADE EVERY 3 YEARS : CTD OFFERS MAINTENANCE CONTRACTS Drain the pump Control the valves and the joints of the pump Control the hydraulic and electrical circuits Clean the paddle of the flowmeter NOTES : 22

ANNEXES 23

EC declaration of conformity DECLARATION DE CONFORMITE CTD pulvérisation Parc d entreprises VISIONIS 01090 GUÉREINS - FRANCE déclarons sous notre seule responsabilité que l ensemble des produits de la gamme : TRITON auxquels se réfère cette déclaration, satisfont aux dispositions des directives : - Directive 2006/42/CE - Directive 97/23/CE et sont conformes à la norme européenne suivante : - EN 16327 Fait à Guéreins, le 13/11/2017 F.R. BARBIER Représentant légal 24

HEAD OFFICE Parc d entreprise Visionis - 01090 GUÉREINS (France) Tel. : +33 (0)4 74 06 47 00 Fax. : +33 (0)4 74 06 47 09 Email : incendie@ctd-pulverisation.com www.ctd-pulverisation.com SAS (simplified joint stock company) with a capital of 150,000 - SIRET 347 522 823 00025 - NAF 2920Z 25