Powrmatic PZN / PZN X Hot Water Heater

Similar documents
Powrmatic PZN / PZN-X Hot Water Heat Emitter Industrial & Commercial Heating Systems

CP+ Gas & Oil Cabinet Heater Range

VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

PT Radiant Heater Range

PT Radiant Heater Range Controlling your working environment. heating ventilation integrity

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

OUH Suspended Oil Unit Heater

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

Radiant Heaters Vacuum / Forced U-Tube & Linear Range

HEM Heat Exchange Modules

OUH Suspended Oil Unit Heater Gas Oil Fired & Optional Kerosene

Radiant Heater Range SRP Superior Radiant Products From Powrmatic

TE Air Rotation Space Heater Industrial & Commercial Heating Systems

NVxEA External Gas Unit Heater

VPC Gas Cabinet Heater Range

Destratification Fans Industrial & Commercial Heating Systems

NEW GREEN TECHNOLOGY

NVx Suspended Gas Unit Heater

Powrmatic PQ Electric Quartz Infrared Heaters - A Range

Powrmatic Control Systems Industrial & Commercial Heating Systems

CECx Destratification Fan

Installation Instructions

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

Aquamatic PZN - water unit heater

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

Küba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

UniTrane Ductable Units D-line and B-Line

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

CLIMACIAT AIR COMPACT

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

Flue & Flue Kits for NVx, VPC & NVS

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

42AM. Air heaters PRODUCT SELECTION DATA

Roof top SPACE RPC 315Z R407C MA00

Condensing Units CUS 15-60

Halton Rex 600 Basic R6B - Active chilled beam

Technology for life. Unit heater LH

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

OUH Suspended Oil Unit Heater Industrial & Commercial Heating Systems

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

Equipment guide for local exhaust ventilation (LEV)

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

ENERGY RECOVERY VENTILATION (ERV)

Conditioning your ambient, maximising your comfort.

Polaris-I-60. active chilled beam. the future of space conditioning

Power X High Power Condensing Wall-Hung Boilers

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

Technical documentation Fan coil unit

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

VERSO Air Handling Units

PQ-A Electric Quartz Infrared Heaters

Engineered efficiency - no matter where or what. KMe Coolers Fresh ideas from Searle. GEA Searle

Power X High Power Condensing Wall-Hung Boilers

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

Powrmatic Air Conditioning Product Brochure 2017 In Partnership With Midea Air Conditioning & Coolair Evaporative Cooling

Transformer oil coolers BETA & CETA

Warnings, Safety Information and Guidance

Fan coil unit KL. Wall unit Ceiling unit

Units for suspended ceilings

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

Helios. Unit Heater. Thickness 1 mm. Diameter 22 mm. Pitch 2,5 mm. Fin 0,12 mm

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON EL. PROTON EL Electric heating.

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

Energy. The Energy ducted units have been designed. Heat Recovery Unit

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

CPx Gas or Oil Cabinet Heater Range

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Centrifugal air heaters hot water or electrical supply

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Product Specifications. Vertical Floor Consoles By First Co.

ECV SP GUE ALO CAT ICAL TECHN

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

The ultimate in air handling units: directly and indirectly fired

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

Recessed. Air Curtain. Fig 1. Recessed air curtain

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

Heating / Air Conditioning Energy Heat Recovery Units ENVIRONMENTAL COMFORT

Conditioning your ambient, maximising your comfort.

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Vertical self-contained air conditioner

Transcription:

Powrmatic PZN / PZN X Hot Water Heater Industrial & Commercial Heating Systems. www.powrmatic.co.uk HEATING // VENTILATION // AIR CONDITIONING // OEM PRODUCTS

PZN Overview The Powrmatic PZN is a water-supplied suspended air heater which can discharge air horizontally or vertically. The unit has a powerful axial fan which means it is suitable for many applications. Powrmatic offers an extensive range of accessories allowing it to be aligned for various applications. For example, the unit can be made suitable for external air connection in combination with filtering and a mixing box for the dilution of fresh external air. Models Available PZN - Pre Painted Panels PZN-X - Stainless Steel Casing (Special Order) Casing Constructed of a self supporting galvanized, pre-painted metal or stainless steel (PZN-X). The casing features a modern and attractive aesthetic line. The geometry adopted gives the heater maximum compactness and versatility. Heat Exchanger Constructed of a high efficiency copper tube battery with an aluminium finned exchange coil. Steel water couplings with air vent valves and both fixed on anti-break clamp brackets. Axial Fan ERP 2015 compliant low noise, high performance axial fans mounted in a safety protection cage. Featuring a two or three speed motor (model dependant). Accessories Full range of accessories available ( see pages 4 & 5) Construction 1 - Electric propeller fan with safety protection grid 2 - Fan panel. 3 - Collector with upper and bottom air vent and anti-torsion plate. 4 - Exchange battery copper-aluminium. 5 - Removable frontal panel with horizontal diffusion louvres. Galvanized painted steel 2

Duties Model Heating Capacity Rows Speed Max- Med- Min Fans Max. Air Flow Air Throw Water Pressure Drop Water flow rate Elect supply Elect power Sound pressure db (A) Kw RPM m 3 /h m KPa I/h V-50Hz W Max Min PZN-12 13.3 2 1 1750 22 26 785 73 50 41 PZN-13 17.3 3 1 1550 17 20 1020 73 50 41 PZN-22 17.7 2 1 2450 25 17 1044 105 51 45 PZN-23 23.8 3 1 2300 19 20 1401 105 51 45 PZN-32 22.0 2 1 2800 31 30 1296 110 52 43 PZN-33 28.5 3 1400 1 2550 25 17 1680 110 52 43 900 230 ~ PZN-42 27.4 2 700 1 3600 31 24 1612 130 53 43 PZN-43 35.4 3 1 3400 25 19 2141 130 53 43 PZN-52 31.9 2 1 3950 32 20 1876 160 53 43 PZN-53 42.7 3 1 3900 24 13 2514 160 53 43 PZN-62 39.1 2 1 5200 33 13 2300 200 53 47 PZN-63 52.4 3 1 4900 26 16 3086 200 53 47 PZN-72 47.4 2 1 6700 39 14 2793 245 52 46 PZN-73 63.0 3 1 6200 37 12 3707 245 52 46 PZN-82 67.7 2 900 2 8500 38 11 3985 400 3N 260 54 49 PZN-83 87.8 3 700 2 7700 32 9 5173 ~ 260 53 49 PZN-92 88.8 2 2 12550 40 21 5229 500 53 48 PZN-93 114.9 3 2 10900 38 17 6764 500 53 48 Notes: (1) Heating: air inlet temperature 15 C, water temperature 85-70 C, relative humidity 50%, atmospheric pressure 1013 mbar, at maximal fan speed. (2) Distance from the equipment where with remaining air speed of 0.2 m/s. (3) Equipment installed on the wall, at 3 meter distance from the floor, maximal and minimal fan speed, measured in free field. Dimensions PZN PZN Model Dimensions mm A B C Fan N Kg PZN 12 555 280 390 1 14 PZN 13 555 280 390 1 15 PZN 22 605 280 440 1 16 PZN 23 605 280 440 1 18 PZN 32 655 280 490 1 19 PZN 33 655 280 490 1 21 PZN 42 705 280 540 1 23 PZN 43 705 280 540 1 24 PZN 52 755 280 590 1 25 Notes: Please contact Powrmatic for PZN-X Weights 3 Model Dimensions mm A B C Fan N Kg PZN 53 755 280 590 1 28 PZN 62 805 280 640 1 29 PZN 63 805 280 640 1 32 PZN 72 855 280 690 1 40 PZN 73 855 280 690 1 43 PZN 82 1.205 280 690 2 58 PZN 83 1.205 280 690 2 63 PZN 92 1.405 280 690 2 70 PZN 93 1.405 280 690 2 76

Model Identification PZN - 4 2 MODEL SIZE NUMBER OF ROWS PZN Accessories 4

PZN Accessories (Continued) PZN Controls Accessories & Controls Part Numbers Descripton Ref No Model Number PZN 12-13 PZN 22-23 PZN 32-33 PZN 42-43 PZN 52-53 PZN 62-63 PZN 72-73 PZN 82-83 PZN 92-93 Support Brackets 1 PZN-SB Vertical Louvres 2 PZN-VL1 PZN-VL2 PZN-VL3 PZN-VL4 PZN-VL5 PZN-VL6 PZN-VL7 PZN-VL8 PZN-VL9 Ceiling Mounting Kit 3 PZN-CMK1 PZN-CMK2 PZN-CMK3 PZN-CMK4 PZN-CMK5 PZN-CMK6 PZN-CMK7 PZN-CMK8 PZN-CMK9 Inlet Hood 4 PZN-IH1 PZN-IH2 PZN-IH3 Air Filter 5 PZN-AF1 PZN-AF2 PZN-AF3 PZN-AF4 PZN-AF5 PZN-AF6 PZN-AF7 PZN-AF8 PZN-AF9 Support Brackets (Filter) 6 PZN-SBF Mixing Box 7 PZN-MB1 PZN-MB2 PZN-MB3 PZN-MB4 PZN-MB5 PZN-MB6 PZN-MB7 PZN-MB8 PZN-MB9 Support Brackets (F/MB) 8 PZN-SBMB 4 Speed Control 9 PZN-SC12 PZN-SC13 n/a n/a n/a Room Thermostat 10 PZN-RT Speed Changeover Switch 11 n/a n/a n/a n/a n/a n/a PZN-SCS n/a n/a Speed Control Panel 12 n/a n/a n/a n/a n/a n/a PZN-SCP Support brackets - for support and anchorage made of galvanised steel. Vertical Louvres - made of galvanized steel (PZN version), stainless steel (PZN-X version) to set the air flow horizontally. Ceiling mounting Kit - mounting onto ceiling Inlet Hood- for mounting on the fresh air intake in case of outside installation. Air filter- to treat and filter the intake fresh air or room inlet air with a plenum containing filtering cells, to be mounted inside the unit. Support brackets (filter) - for support of the unit with a filter kit in case of fresh air intake. Mixing Box - for the complete or partial renewal of the fresh air. The kit is composed of an air inlet plenum, two dampers connected by a connection device. Support brackets (F/MB) for support of the unit and the mixing chamber kit or the air filter kit 4-speed control - only for single phase models (STOP - I - II - III ). Room thermostat- single stage, with ON-OFF switch. Speed changeover switch - 3-modes speed control (STOP-MIN-MAX), only for three phase models. Speed Control Panel - with speed changeover switch, with 3-mode air speed switch settings, complete with fittings and connectors; only for three-phase models. 5

Contact Powrmatic General The following notes are provided as a guide, however installers and operators should fully acquaint themselves with the more detailed guidance provided in the relevant installation manual. For copies of such manuals please consult our technical department or visit our website - www.powrmatic.co.uk Installation Clearances Particular clearances may be necessary for the correct and safe function of the heater as well as for maintenance purposes. Such clearances are confirmed in the relevant installation manual. Standards PZN Unit heaters must be installed, commissioned and operated with due regard to appropriate regulations, relevant Codes of Practice which may include but is not limited to BS5410, BS6644, BS6880 and the possible requirements of Local Authorities, Fire Officers and insurers as well as Powrmatic s installation manual. Position & Location PZN heaters can be mounted either horizontally or vertically by using PZN support brackets. It is important that all supporting structures have due regard to the relevant weight loadings. Heaters should not be installed in hazardous areas or areas where there is a foreseeable risk of flammable or corrosion inducing particles, gases or vapours being drawn in. Water Treatment Water quality used with heaters can have a significant effect on both the efficiency of the heater and also the life expectancy of the heater. Water supply quality may adversely affect the efficiency and performance of heating systems. The situation can intensify where higher temperatures or demands exist. Guidance can be found in BSRIA BG 29/2011 Pre-Commission Cleaning of Pipework Systems. Additional physical treatment should be evaluated for the removal of oxygen and filtration of the system water. During final filling of the system, a chemical water treatment formulation should be added to the primary circuit to control corrosion and the formation of scale and sludge. Reasonable provision would be to follow the guidance on how to prepare and commission systems given in BS 7593. Chemical water treatment must be introduced in a controlled manner and with a facility for monitoring the water quality to ensure effective treatment is maintained. The chemical concentration of the system water should be regularly checked (especially after the event of any leaks being detected) to ensure it remains effective. Areas where special consideration or advice may be required could include but is not limited to - Where de-greasing solvents are present, even in minute concentrations Where paint spraying is carried out Where styrenes or other laminating products are used Where airborne silicone is present Where petrol engined vehicles are stored or maintained Where dust is present (i.e. wood working or joinery shops) Where high levels of extract persist Guarantee Powrmatic PZN heaters are provided with a comprehensive guarantee. For United Kingdom sales the heater has the benefit of a 12 month parts only guarantee. All guarantees are subject to terms and conditions. Installation in such areas may be possible under specific conditions. Please consult our technical department for further information. Powrmatic Limited Hort Bridge Ilminster Somerset TA19 9PS tel: +44 (0) 1460 53535 fax: +44 (0) 1460 52341 e-mail: info@powrmatic.co.uk web: www.powrmatic.co.uk Powrmatic Ireland 45 Broomhill Close Tallaght Dublin 24 tel: +353 (0) 1452 1533 fax: +353 (0) 1452 1764 e-mail: info@powrmatic.ie web: www.powrmatic.ie Powrmatic pursues a policy of continuous improvement in both design and performance of its products and therefore reserves the right to change, amend or vary specifications without notice. Whilst the details contained herein are believed to be correct they do not form the basis of any contract and interested parties should contact the Company to confirm whether any material alterations have been made since publication of this brochure. Issue 5.0 August 2015