Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Similar documents
Commercial High-Efficiency Condensing Units

16 SEER TWO-STAGE AIR CONDITIONERS

Commercial High-Efficiency Condensing Units

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

13 SEER CONDENSING UNITS

TECHNICAL SPECIFICATIONS

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

MAC N-407 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

PACKAGE AIR CONDITIONER

TECHNICAL SPECIFICATIONS

Condensing Units & Air Handlers

R4H4. Product Specifications

R4H4. Product Specifications

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

PRODUCT SPECIFICATIONS

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH


JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

TECHNICAL SPECIFICATIONS

13 SEER CONDENSING UNITS & AIR HANDLERS

General Description. Operation

N4H4. Product Specifications

Indoor Air Handlers with Compressors MVS and MVW

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

RSG16**S1M. Split System Air Conditioner 16 SEER

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

T P A 120 S 4 S N 1 Y

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

Advance Release September 2009

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

2 shp 13 lc 1 36 t - 1 a

PAJ3. Product Specifications

MAC-120HE-03 Air-Cooled Chiller

WCH5**4. Product Specifications

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

C13-Series Engineering Guide

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

Submitted to Reference Approval Construction Unit Designation Schedule #

TZPL SERIES. Applications Thermal Zone remote heat pumps offer comfort and dependability for single, multi-family and light commercial applications.

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Product Catalog Split System Air Conditioners Odyssey

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Corp L2 Revised

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Unit Features & Benefits RQPM/RQRM Series

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

TECHNICAL SPECIFICATIONS

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

CWA4 Chilled & Hot Water Fan Coil

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

ELECTRICAL QUANTITY WEIGHT (LB)

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

Bosch BVA Series Air Handler

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

VertiCool Aurora Engineering Guide

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

Transcription:

RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 1

Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 46,500 Electric Power (W) 3,550 Energy Efficiency Ratio (EER) 13.1 Integrated Energy Efficiency Ratio (IEER) 14.4 Qty-Nominal Tons-Type Capacity Reduction 1-3.5 - Scroll 0/50/100 (HGBP) or 0/10-100 (Digital) Electric Supply (V/Phase/Hz) 230/1/60 208-230/3/60 460/3/60 575/3/60 Run Load Amps (RLA) 21.8 13.7 6.2 4.8 Locked Rotor Amps (LRA) 117 83 41 33 Qty - Horsepower (HP) 1-1/2 FLA (ea) 6.2 5.4 2.7 1.3 Type Minimum Circuit Ampacity 33.5 22.5 10.5 7.3 Max. Time Delay Fuse or HACR Breaker 50 35 15 15 PSC Airflow (CFM) 4,000 Diameter (in)-pitch (deg) 24-36 Quantity 2 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 15.4 Rows - Fins per Inch 4-12 Suction Line (in OD) 3 / 4 Liquid Line (in OD) 1 / 2 Optional Hot Gas Bypass (in OD) 3 Optional Hot Gas Reheat (in OD) 3 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 565 Shipping Weight (lbs) 615 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages 18-19. 24 Cooling Saturated Suction Temperature ( F) 35.0 40.0 45.0 50.0 55.0 Ambient Temperature ( F) 95.0 100.0 105.0 Total Capacity (Btu/h) 39,000 37,400 36,000 Electric Power (W) 3,370 3,560 3,765 Total Capacity (Btu/h) 42,500 41,000 39,500 Electric Power (W) 3,380 3,575 3,780 Total Capacity (Btu/h) 46,500 44,500 43,000 Electric Power (W) 3,400 3,590 3,800 Total Capacity (Btu/h) 50,500 48,500 47,000 Electric Power (W) 3,420 3,615 3,815 Total Capacity (Btu/h) 54,500 52,500 50,500 Electric Power (W) 3,440 3,635 3,840 2

Data - RCA 061 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 55,600 Electric Power (W) 4,244 Energy Efficiency Ratio (EER) 13.1 Integrated Energy Efficiency Ratio (IEER) 14.2 Qty-Nominal Tons-Type Capacity Reduction 1-4.5 - Scroll 0/50/100 (HGBP) or 0/10-100 (Digital) Electric Supply (V/Phase/Hz) 230/1/60 208-230/3/60 460/3/60 575/3/60 Run Load Amps (RLA) 26.4 16.0 7.8 7.6 Locked Rotor Amps (LRA) 134 110 52 54 Qty - Horsepower (HP) 1-1/2 FLA (ea) 6.2 5.4 2.7 1.3 Type Minimum Circuit Ampacity 39.2 25.3 12.3 8.4 Max. Time Delay Fuse or HACR Breaker 60 40 20 15 PSC Airflow (CFM) 4,000 Diameter (in)-pitch (deg) 24-36 Quantity 2 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 15.4 Rows - Fins per Inch 4-12 Suction Line (in OD) 7 Liquid Line (in OD) 1 / 2 Optional Hot Gas Bypass (in OD) 3 Optional Hot Gas Reheat (in OD) 3 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 590 Shipping Weight (lbs) 640 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages 18-19. 24 Cooling Saturated Suction Temperature ( F) 35.0 40.0 45.0 50.0 55.0 Ambient Temperature ( F) 95.0 100.0 105.0 Total Capacity (Btu/h) 45,000 43,000 42,000 Electric Power (W) 4,250 4,485 4,775 Total Capacity (Btu/h) 53,500 47,000 46,000 Electric Power (W) 4,355 4,530 4,785 Total Capacity (Btu/h) 55,000 51,000 50,000 Electric Power (W) 4,380 4,615 4,865 Total Capacity (Btu/h) 57,000 56,000 54,000 Electric Power (W) 4,435 4,675 4,930 Total Capacity (Btu/h) 62,000 60,000 58,000 Electric Power (W) 4,530 4,770 5,035 3

Data - RCA 071 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 74,500 Electric Power (W) 6,422 Energy Efficiency Ratio (EER) 11.6 Integrated Energy Efficiency Ratio (IEER) 12.7 Qty-Nominal Tons-Type Capacity Reduction 1-6.3 - Scroll 0/50/100 (HGBP) or 0/10-100 (Digital) Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60 Run Load Amps (RLA) 23.2 11.2 7.7 Locked Rotor Amps (LRA) 164 75 54 Qty - Horsepower (HP) 1-1/2 FLA (ea) 5.4 2.7 1.3 Type Minimum Circuit Ampacity 34.4 16.7 11.2 Max. Time Delay Fuse or HACR Breaker 50 25 15 PSC Airflow (CFM) 4,000 Diameter (in)-pitch (deg) 24-36 Quantity 2 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 15.4 Rows - Fins per Inch 4-12 Suction Line (in OD) 7 Liquid Line (in OD) 1 / 2 Optional Hot Gas Bypass (in OD) 3 Optional Hot Gas Reheat (in OD) 1 / 2 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 610 Shipping Weight (lbs) 660 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages 18-19. 25 Cooling Saturated Suction Temperature ( F) 35.0 40.0 45.0 50.0 55.0 Ambient Temperature ( F) 95.0 100.0 105.0 Total Capacity (Btu/h) 60,200 58,000 56,000 Electric Power (W) 6,285 6,585 6,905 Total Capacity (Btu/h) 66,000 63,000 61,000 Electric Power (W) 6,415 6,720 7,045 Total Capacity (Btu/h) 71,000 69,000 66,000 Electric Power (W) 6,600 6,860 7,245 Total Capacity (Btu/h) 77,000 74,000 71,000 Electric Power (W) 6,695 7,005 7,330 Total Capacity (Btu/h) 82,000 80,000 77,000 Electric Power (W) 6,840 7,150 7,480 4

Data - RCA 101 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 107,500 Electric Power (W) 9,430 Energy Efficiency Ratio (EER) 11.4 Integrated Energy Efficiency Ratio (IEER) 12.8 Qty-Nominal Tons-Type Capacity Reduction 1-9.0 - Scroll 0/50/100 (HGBP) or 0/10-100 (Digital) Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60 Run Load Amps (RLA) 30.1 16.7 12.2 Locked Rotor Amps (LRA) 225 114 80 Qty - Horsepower (HP) 1-1 FLA (ea) 5.4 2.7 2.0 Type Minimum Circuit Ampacity 41.6 23.1 19.3 Max. Time Delay Fuse or HACR Breaker 70 35 30 PSC Airflow (CFM) 6,200 Diameter (in)-pitch (deg) 26-26 Quantity 3 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 23.1 Rows - Fins per Inch 4-12 Suction Line (in OD) 1 1 Liquid Line (in OD) 5 Optional Hot Gas Bypass (in OD) 1 / 2 Optional Hot Gas Reheat (in OD) 5 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 825 Shipping Weight (lbs) 900 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages 18-19. 30 Cooling Saturated Suction Temperature ( F) 35.0T 40.0 45.0 50.0 55.0 Ambient Temperature ( F) 95.0 100.0 105.0 Total Capacity (Btu/h) 89,000 86,000 83,000 Electric Power (W) 8,910 9,435 9,840 Total Capacity (Btu/h) 97,000 94,000 90,000 Electric Power (W) 9,130 9,515 10,075 Total Capacity (Btu/h) 105,000 101,000 98,000 Electric Power (W) 9,300 9,750 10,225 Total Capacity (Btu/h) 113,000 109,000 106,000 Electric Power (W) 9,465 9,935 10,395 Total Capacity (Btu/h) 122,000 118,000 113,000 Electric Power (W) 9,660 10,110 10,680 5

Data - RCA 141 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 137,100 Electric Power (W) 12,578 Energy Efficiency Ratio (EER) 10.9 Integrated Energy Efficiency Ratio (IEER) 12.2 Qty-Nominal Tons-Type Capacity Reduction 1-12.0 - Scroll 0/50/100 (HGBP) or 0/10-100 (Digital) Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60 Run Load Amps (RLA) 48.1 18.6 15.1 Locked Rotor Amps (LRA) 245 125 100 Qty - Horsepower (HP) 1-1 FLA (ea) 5.4 2.7 2.0 Type Minimum Circuit Ampacity 64.0 25.4 22.4 Max. Time Delay Fuse or HACR Breaker 110 40 35 PSC Airflow (CFM) 6,200 Diameter (in)-pitch (deg) 26-26 Quantity 3 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 23.1 Rows - Fins per Inch 4-12 Suction Line (in OD) 1 3 Liquid Line (in OD) 5 Optional Hot Gas Bypass (in OD) 1 / 2 Optional Hot Gas Reheat (in OD) 5 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 900 Shipping Weight (lbs) 975 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages 18-19. 35 Cooling Saturated Suction Temperature ( F) 35.0 40.0 45.0 50.0 55.0 Ambient Temperature ( F) 95.0 100.0 105.0 Total Capacity (Btu/h) 113,000 110,000 106,000 Electric Power (W) 12,000 12,470 13,085 Total Capacity (Btu/h) 124,000 119,000 115,000 Electric Power (W) 12,150 12,845 13,340 Total Capacity (Btu/h) 133,000 129,000 124,000 Electric Power (W) 12,535 13,005 13,615 Total Capacity (Btu/h) 143,000 139,000 134,000 Electric Power (W) 12,710 13,295 13,905 Total Capacity (Btu/h) 153,000 148,000 144,000 Electric Power (W) 13,070 13,710 14,210 6

Data - RCA 171 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 165,900 Electric Power (W) 13,598 Energy Efficiency Ratio (EER) 12.2 Integrated Energy Efficiency Ratio (IEER) 13.6 Qty-Nominal Tons-Type Capacity Reduction 1-13.5 - Scroll 0/50/100 (HGBP) or 0/10-100 (Digital) Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60 Run Load Amps (RLA) 51.3 23.1 19.9 Locked Rotor Amps (LRA) 300 150 109 Qty - Horsepower (HP) 2-1 FLA (ea) 3.4 / 5.4 1.7 / 2.7 2.0/2.0 Type Minimum Circuit Ampacity 74.8 33.4 28.9 Max. Time Delay Fuse or HACR Breaker 125 50 45 PSC Airflow (CFM) 12,400 Diameter (in)-pitch (deg) 26-32 Quantity 4 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 30.8 Rows - Fins per Inch 4-12 Suction Line (in OD) 1 3 Liquid Line (in OD) 7 Optional Hot Gas Bypass (in OD) 5 Optional Hot Gas Reheat (in OD) 5 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 1,250 Shipping Weight (lbs) 1,345 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages 18-19. 50 Cooling Saturated Suction Temperature ( F) 35.0 40.0 45.0 50.0 55.0 Ambient Temperature ( F) 95.0 100.0 105.0 Total Capacity (Btu/h) 144,000 138,000 133,000 Electric Power (W) 12,265 12,865 13,540 Total Capacity (Btu/h) 157,000 151,000 146,000 Electric Power (W) 12,400 13,015 13,670 Total Capacity (Btu/h) 170,000 164,000 158,000 Electric Power (W) 12,560 13,170 13,820 Total Capacity (Btu/h) 183,000 177,000 171,000 Electric Power (W) 12,775 13,390 14,015 Total Capacity (Btu/h) 198,000 191,000 185,000 Electric Power (W) 12,980 13,560 14,180 7

Data - RCA 201 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 192,000 Electric Power (W) 16,271 Energy Efficiency Ratio (EER) 11.8 Integrated Energy Efficiency Ratio (IEER) 13.2 Qty-Nominal Tons-Type Capacity Reduction 1-15.0 - Scroll 0/50/100 (HGBP) or 0/10-100 (Digital) Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60 Run Load Amps (RLA) 55.8 26.9 23.7 Locked Rotor Amps (LRA) 340 173 132 Qty - Horsepower (HP) 2-1 FLA (ea) 3.4 / 5.4 1.7 / 2.7 2.0/2.0 Type Minimum Circuit Ampacity 78.8 40.0 57.6 Max. Time Delay Fuse or HACR Breaker 125 60 80 PSC Airflow (CFM) 12,400 Diameter (in)-pitch (deg) 26-32 Quantity 4 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 30.8 Rows - Fins per Inch 4-12 Suction Line (in OD) 1 3 Liquid Line (in OD) 7 Optional Hot Gas Bypass (in OD) 5 Optional Hot Gas Reheat (in OD) 3 / 4 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 1,300 Shipping Weight (lbs) 1,400 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages 18-19. 58 Cooling Saturated Suction Temperature ( F) 35.0 40.0 45.0 50.0 55.0 Ambient Temperature ( F) 95.0 100.0 105.0 Total Capacity (Btu/h) 167,000 161,000 155,000 Electric Power (W) 14,500 15,230 16,020 Total Capacity (Btu/h) 182,000 176,000 170,000 Electric Power (W) 14,740 15,415 16,175 Total Capacity (Btu/h) 197,000 191,000 185,000 Electric Power (W) 14,955 15,665 16,355 Total Capacity (Btu/h) 213,000 207,000 199,000 Electric Power (W) 15,170 15,865 16,635 Total Capacity (Btu/h) 230,000 223,000 215,000 Electric Power (W) 15,390 16,100 16,850 8

Data - RCA 271 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 241,300 Electric Power (W) 22,343 Energy Efficiency Ratio (EER) 10.8 Integrated Energy Efficiency Ratio (IEER) 12.4 Qty-Nominal Tons-Type Capacity Reduction 1-21.0 - Tandem Scroll 0/50/100 (HGBP) or 0/10-100 (Digital) Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60 Run Load Amps (RLA) 33.3 17.9 12.8 Locked Rotor Amps (LRA) 239 125 80 Qty - Horsepower (HP) 2-1 FLA (ea) 3.4 / 5.4 1.7 / 2.7 2.0/2.0 Type Minimum Circuit Ampacity 85.7 45.7 32.8 Max. Time Delay Fuse or HACR Breaker 110 60 45 PSC Airflow (CFM) 12,400 Diameter (in)-pitch (deg) 26-32 Quantity 4 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 30.8 Rows - Fins per Inch 4-12 Suction Line (in OD) 1 5 Liquid Line (in OD) 7 Optional Hot Gas Bypass (in OD) 5 Optional Hot Gas Reheat (in OD) 7 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 1,400 Shipping Weight (lbs) 1,500 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages 18-19. 58 Cooling Saturated Suction Temperature ( F) 35.0 40.0 45.0 50.0 55.0 Ambient Temperature ( F) 95.0 100.0 105.0 Total Capacity (Btu/h) 213,000 205,000 197,000 Electric Power (W) 19,315 20,310 21,360 Total Capacity (Btu/h) 232,000 224,000 216,000 Electric Power (W) 19,590 20,570 21,620 Total Capacity (Btu/h) 252,000 243,000 236,000 Electric Power (W) 20,020 21,000 21,895 Total Capacity (Btu/h) 273,000 264,000 254,000 Electric Power (W) 20,360 21,330 22,365 Total Capacity (Btu/h) 294,000 284,000 275,000 Electric Power (W) 20,720 21,700 22,730 9

Data - RCA 361 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 288,600 Electric Power (W) 24,879 Energy Efficiency Ratio (EER) 11.6 Integrated Energy Efficiency Ratio (IEER) 12.8 Qty-Nominal Tons-Type Capacity Reduction 1-24.0 - Tandem Scroll 0/50/100 (HGBP) or 0/10-100 (Digital) Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60 Run Load Amps (RLA) 48.1 18.6 15.1 Locked Rotor Amps (LRA) 245 125 100 Qty - Horsepower (HP) 4-1 FLA (ea) 3.4 / 3.4 / 5.4 / 5.4 1.7 / 1.7 / 2.7 / 2.7 2.0 / 2.0 / 2.0 / 2.0 Type Minimum Circuit Ampacity 125.6 51.6 41.1 Max. Time Delay Fuse or HACR Breaker 150 70 50.0 PSC Airflow (CFM) 28,000 Diameter (in)-pitch (deg) 26-32 Quantity 4 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 70.0 Rows - Fins per Inch 2-14 Suction Line (in OD) 1 5 Liquid Line (in OD) 1 1 Optional Hot Gas Bypass (in OD) 7 Optional Hot Gas Reheat (in OD) 7 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 1,700 Shipping Weight (lbs) 1,820 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages 18-19. 65 Cooling Saturated Suction Temperature ( F) 35.0 40.0 45.0 50.0 55.0 Ambient Temperature ( F) 95.0 100.0 105.0 Total Capacity (Btu/h) 240,000 231,000 221,000 Electric Power (W) 23,635 24,700 26,050 Total Capacity (Btu/h) 260,000 251,000 243,000 Electric Power (W) 24,090 25,140 26,135 Total Capacity (Btu/h) 283,000 274,000 264,000 Electric Power (W) 24,410 25,485 26,620 Total Capacity (Btu/h) 306,000 296,000 285,000 Electric Power (W) 24,890 26,010 27,190 Total Capacity (Btu/h) 332,000 320,000 309,000 Electric Power (W) 25,085 26,360 27,570 10

Data - RCA 421 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s) Condenser Fan(s) Condenser Coil(s) Refrigerant Connection(s) Cabinet Refrigerant - R410A Weights Total Capacity (Btu/h) 369,700 Electric Power (W) 33,609 Energy Efficiency Ratio (EER) 11.0 Integrated Energy Efficiency Ratio (IEER) 12.2 Qty-Nominal Tons-Type Capacity Reduction 1-31.5 - Tandem Scroll 0/50/100 (HGBP) or 0/10-100 (Digital) Electric Supply (V/Phase/Hz) 208-230/3/60 460/3/60 575/3/60 Run Load Amps (RLA) 55.8 26.9 23.8 Locked Rotor Amps (LRA) 340 173 132 Qty - Horsepower (HP) 4-1 FLA (ea) 3.4 / 3.4 / 5.4 / 5.4 1.7 / 1.7 / 2.7 / 2.7 2.0 / 2.0 / 2.0 / 2.0 Type Minimum Circuit Ampacity 142.4 70.5 61.4 Max. Time Delay Fuse or HACR Breaker 175 90 85 PSC Airflow (CFM) 28,000 Diameter (in)-pitch (deg) 26-32 Quantity 4 Tube Material - Fin Material Copper - Aluminum Face Area (sq. ft) 70.0 Rows - Fins per Inch 2-14 Suction Line (in OD) 2 1 Liquid Line (in OD) 1 1 Optional Hot Gas Bypass (in OD) 7 Optional Hot Gas Reheat (in OD) 7 Sheet Metal Finish G90 Galvanized Polyester Coating Top Pan Thickness (ga) 16 Sides and Panels Thickness (ga) 18 Bottom Pan Thickness (ga) 16 Charge based on 25' line set (lbs per circuit) Weight (lbs) 1,770 Shipping Weight (lbs) 1,900 NOTES: 1. Refrigerant connections are actual connection sizes at unit. For line sizing, see Reference Information tables on pages 18-19. 75 Cooling Saturated Suction Temperature ( F) 35.0 40.0 45.0 50.0 55.0 Ambient Temperature ( F) 95.0 100.0 105.0 Total Capacity (Btu/h) 306,000 294,000 285,000 Electric Power (W) 31,685 33,335 34,495 Total Capacity (Btu/h) 334,000 322,000 309,000 Electric Power (W) 32,350 33,705 35,465 Total Capacity (Btu/h) 359,000 350,000 338,000 Electric Power (W) 33,355 34,440 35,885 Total Capacity (Btu/h) 391,000 375,000 365,000 Electric Power (W) 33,900 35,550 36,695 Total Capacity (Btu/h) 421,000 407,000 391,000 Electric Power (W) 34,815 36,165 37,925 11

Typical Wiring Diagram Condensing Disconnect L1 L2 L3 Condensing Control Panel R Y 24VAC, Switched Compressor G Supply Fan C 24VAC, Common, Unswitched NOTES: 1. All electrical wiring and connections, including electrical grounding must comply with: a. ed States: Refer to NFPA 70- latest revision, National Electrical Code, and local ordinances. b. Canada: Refer to CSA C22.1, Part 1- latest revision, Canadian Electrical Code and local ordinances. 2. Class 1 circuit 3. Condensing unit disconnect is not provided with condensing unit as standard. Disconnect may be obtained from factory as optional equipment or provided by others. 4. Terminal Y2 is only used on dual-circuit units. Typical Split System Installation Disconnect Interconnecting Control Wiring Liquid Line Suction Line Sleeve And Flashing Condensing Optional Hot Gas Reheat Optional Hot Gas Bypass Disconnect Outside Air or Return Air Air Handler Supply Air Trap And Drain Connection NOTES: 1. Condensing unit disconnect is not provided with condensing unit as standard. Disconnect may be obtained from factory as optional equipment or provided by others. 2. Air handler, air handler disconnect, interconnecting control wiring, all refrigerant line piping and sleeve/flashing materials are by others. 3. Suction, hot gas bypass, and hot gas reheat lines should be insulated with 5/8 minimum thickness closed cell foam insulation. Liquid line exposed to high ambient temperatures should be insulated 5/8 minimum thickness closed cell foam insulation. 12

Typical Installation with on Bottom Optional Hot Gas Reheat Condensate Trap And Pipe Loop To Top Of Coil Suction Liquid Optional Hot Gas Bypass Slope Down Towards Condensing NOTES: 1. To prevent oil migration, lines should slope downwards towards the condensing unit and should slope downward away from the air handler. 2. Vertical risers greater than 4' in height should have a P trap installed at the base of the air handler. 3. Vertical risers greater than 20' in height require an extra P trap for every 20' of riser height in addition to the P trap installed at the base of the air handler. The trap is inverted at the top of the vertical rise. Typical Installation with Condensing on Top Optional Hot Gas Bypass Suction Liquid Optional Hot Gas Reheat Condensate Trap And Pipe Slope Down From Air Handler NOTES: 1. To prevent oil migration, lines should slope downwards towards the condensing unit and should slope downward away from the air handler. 2. Vertical risers greater than 4' in height should have a P trap installed at the base of the air handler. 3. Vertical risers greater than 20' in height require an extra P trap for every 20' of riser height in addition to the P trap installed at the base of the air handler. The trap is inverted at the top of the vertical rise. 13

Dimensions - RCA 051/061/071 A TOP VIEW MULTI-DIMENSIONAL VIEW COIL B COIL CONTROLS ELECTRICAL C D Ø E SUCTION LIQUID OPTIONAL HOT GAS REHEAT OPTIONAL HOT GAS BYPASS COMPRESSOR F Q G L M N P H A K R SIDE VIEW BACK VIEW A B C D E F G H K L M N P Q R (in) 3.00 47.38 42.25 52.25 0.75 40.38 39.13 2.00 3.50 5.00 9.00 13.00 20.00 3.25 53.38 14

Dimensions - RCA 101/141 A TOP VIEW MULTI-DIMENSIONAL VIEW COIL COIL COIL B ELECTRICAL C D ØE SUCTION LIQUID OPTIONAL HOT GAS BYPASS OPTIONAL HOT GAS REHEAT COMPRESSOR F G P N M A L K A H J Q SIDE VIEW FRONT VIEW A B C D E F G H J K L M N P Q (in) 3.00 68.00 45.50 55.50 0.88 41.38 40.13 49.50 4.00 5.56 8.56 8.38 11.38 14.13 74.00 15

Dimensions - RCA 171/201/271 TOP VIEW MULTI-DIMENSIONAL VIEW COIL A LIQUID COMPRESSOR ELECTRICAL SUCTION OPTIONAL HOT GAS REHEAT OPTIONAL HOT GAS BYPASS B J H C G F E D SIDE VIEW A BACK VIEW A B C D E F G H J (in) 64.25 52.88 51.38 79.00 22.00 25.50 29.00 16.00 21.00 16

Dimensions - RCA 361/421 TOP VIEW MULTI-DIMENSIONAL VIEW COIL A COMPRESSOR ELECTRICAL SUCTION OPTIONAL HOT GAS REHEAT OPTIONAL HOT GAS BYPASS LIQUID J B C G F E H D SIDE VIEW A BACK VIEW A B C D E F G H J (in) 101.25 53.63 52.13 84.00 22.00 25.50 29.00 16.00 21.00 17

Reference Information Ambient Temperature Correction Factors Ambient Temperature ( F) 85 90 95 100 105 110 115 Total Capacity (Btu/h) 1.05 1.03 1.00 0.98 0.95 0.91 0.87 Sensible Capacity (Btu/h) 1.03 1.02 1.00 0.99 0.97 0.97 0.93 Electric Power (W) 0.95 0.98 1.00 1.03 1.05 1.08 1.11 Recommended Refrigerant Line Sizes- Air Handler Below Condensing (in OD) 0-25 ft. Equivalent Length 26-50 ft. Equivalent Length Nominal Capacity (Btu/h) Hot Gas Hot Gas Hot Gas Hot Gas Suction Liquid Suction Liquid Reheat Bypass Reheat Bypass 36,000 5/8, 5/8 3/8 1/2 3/8 3/4, 3/4 1/2 1/2 3/8 48,000 3/4, 3/4 3/8 5/8 3/8 3/4, 3/4 1/2 5/8 3/8 60,000 3/4, 3/4 1/2 5/8 1/2 7/8, 7/8 1/2 5/8 1/2 72,000 7/8, 7/8 1/2 5/8 1/2 7/8, 7/8 1/2 5/8 1/2 84,000 7/8, 7/8 1/2 3/4 1/2 1-1/8, 7/8 1/2 3/4 1/2 96,000 7/8, 7/8 1/2 3/4 1/2 1-1/8, 7/8 1/2 3/4 1/2 120,000 1-1/8, 7/8 1/2 3/4 5/8 1-3/8, 1-1/8 5/8 3/4 5/8 150,000 1-1/8, 1-1/8 5/8 7/8 5/8 1-3/8, 1-1/8 5/8 7/8 5/8 180,000 1-1/8, 1-1/8 5/8 7/8 5/8 1-3/8, 1-3/8 5/8 7/8 5/8 220,000 1-3/8, 1-3/8 5/8 1-1/8 3/4 1-3/8, 1-3/8 3/4 1-1/8 3/4 250,000 1-3/8, 1-3/8 5/8 1-1/8 3/4 1-3/8, 1-3/8 3/4 1-1/8 3/4 300,000 1-3/8, 1-3/8 3/4 1-1/8 3/4 1-5/8, 1-3/8 3/4 1-1/8 3/4 360,000 1-3/8, 1-5/8 3/4 1-1/8 7/8 1-5/8, 1-5/8 7/8 1-1/8 7/8 420,000 1-5/8, 1-5/8 3/4 1-3/8 7/8 1-5/8, 1-5/8 7/8 1-3/8 7/8 51-75 ft. Equivalent Length 76-100 ft. Equivalent Length Nominal Capacity (Btu/h) Hot Gas Hot Gas Hot Gas Hot Gas Suction Liquid Suction Liquid Reheat Bypass Reheat Bypass 36,000 7/8, 5/8 1/2 5/8 1/2 7/8, 3/4 1/2 5/8 N/A 48,000 7/8, 3/4 1/2 3/4 1/2 7/8, 7/8 1/2 5/8 N/A 60,000 1-1/8, 3/4 1/2 3/4 1/2 7/8, 7/8 1/2 3/4 N/A 72,000 1-1/8, 7/8 1/2 3/4 5/8 1-1/8, 7/8 5/8 3/4 N/A 84,000 1-1/8, 7/8 5/8 7/8 5/8 1-1/8, 7/8 5/8 3/4 N/A 96,000 1-1/8, 1-1/8 5/8 7/8 5/8 1-1/8, 1-1/8 5/8 3/4 N/A 120,000 1-1/8, 1-1/8 5/8 7/8 3/4 1-1/8, 1-1/8 5/8 7/8 N/A 150,000 1-3/8, 1-1/8 5/8 1-1/8 3/4 1-3/8, 1-1/8 3/4 7/8 N/A 180,000 1-3/8, 1-3/8 3/4 1-1/8 3/4 1-3/8, 1-3/8 3/4 1-1/8 N/A 220,000 1-3/8, 1-3/8 3/4 1-1/8 7/8 1-5/8, 1-3/8 3/4 1-3/8 N/A 250,000 1-3/8, 1-3/8 3/4 1-3/8 7/8 1-5/8, 1-3/8 7/8 1-3/8 N/A 300,000 1-5/8, 1-3/8 7/8 1-3/8 1-1/8 2-1/8, 1-5/8 7/8 1-3/8 N/A 360,000 2-1/8, 1-5/8 7/8 1-3/8 1-1/8 2-1/8, 1-5/8 1-1/8 1-3/8 N/A 420,000 2-1/8, 1-5/8 1-1/8 1-3/8 1-1/8 2-1/8, 1-5/8 1-1/8 1-5/8 N/A NOTES: 1. Line sizes are calculated assuming single scroll compressors in Models 051-201 and tandem scroll compressors in Models 271-421. Contact the factory for any other compressor configuration. 2. All piping must comply with standard refrigeration piping techniques. Consult the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Handbook-Refrigeration. 3. Suction, hot gas bypass and hot gas reheat lines should be insulated with a 5/8 minimum thickness closed cell foam insulation. Liquid line exposed to high ambient temperatures should be insulated with a 5/8 minimum thickness closed cell foam insulation. 4. First suction line diameter size is for horizontal runs. Second suction line diameter size is for vertical risers. 5. Maximum suction line vertical lift is 60. Riser-sized traps are required for every 20 of vertical riser starting at the lowest point. 6. If ordered, hot gas reheat and hot gas bypass require only one line. 7. Standard hot gas bypass is not recommended for use with greater than 75 of equivalent line length. Internal hot gas bypass should be used as an alternative. 8. Contact factory for applications with digital scroll compressors. 9. Contact factory for layouts requiring more than 75 of actual line length. 18

Reference Information Recommended Refrigerant Line Sizes- Air Handler Level with or Above Condensing (in OD) 0-25 ft. Equivalent Length 26-50 ft. Equivalent Length Nominal Capacity (Btu/h) Hot Gas Hot Gas Hot Gas Hot Gas Suction Liquid Suction Liquid Reheat Bypass Reheat Bypass 36,000 5/8 3/8 1/2 3/8 3/4 3/8 1/2 3/8 48,000 3/4 3/8 5/8 3/8 7/8 1/2 5/8 3/8 60,000 3/4 1/2 5/8 1/2 7/8 1/2 5/8 1/2 72,000 7/8 1/2 5/8 1/2 1-1/8 1/2 5/8 1/2 84,000 7/8 1/2 3/4 1/2 1-1/8 5/8 3/4 1/2 96,000 7/8 1/2 3/4 1/2 1-1/8 5/8 3/4 1/2 120,000 1-1/8 5/8 3/4 5/8 1-1/8 5/8 3/4 5/8 150,000 1-1/8 5/8 7/8 5/8 1-3/8 3/4 7/8 5/8 180,000 1-1/8 3/4 7/8 5/8 1-3/8 3/4 7/8 5/8 220,000 1-3/8 3/4 1-1/8 3/4 1-3/8 7/8 1-1/8 3/4 250,000 1-3/8 3/4 1-1/8 3/4 1-3/8 7/8 1-1/8 3/4 300,000 1-3/8 7/8 1-1/8 3/4 1-5/8 7/8 1-1/8 3/4 360,000 1-3/8 7/8 1-1/8 7/8 1-5/8 7/8 1-1/8 7/8 420,000 1-5/8 1-1/8 1-3/8 7/8 1-5/8 1-1/8 1-3/8 7/8 51-75 ft. Equivalent Length 76-100 ft. Equivalent Length Nominal Capacity (Btu/h) Hot Gas Hot Gas Hot Gas Hot Gas Suction Liquid Suction Liquid Reheat Bypass Reheat Bypass 36,000 3/4 3/8 5/8 1/2 3/4 1/2 5/8 N/A 48,000 7/8 1/2 3/4 1/2 7/8 1/2 5/8 N/A 60,000 7/8 1/2 3/4 1/2 7/8 1/2 3/4 N/A 72,000 7/8 1/2 3/4 5/8 7/8 1/2 3/4 N/A 84,000 1-1/8 5/8 7/8 5/8 1-1/8 5/8 3/4 N/A 96,000 1-1/8 5/8 7/8 5/8 1-1/8 5/8 3/4 N/A 120,000 1-1/8 3/4 7/8 3/4 1-3/8 5/8 7/8 N/A 150,000 1-3/8 3/4 1-1/8 3/4 1-3/8 3/4 7/8 N/A 180,000 1-5/8 3/4 1-1/8 3/4 1-3/8 3/4 1-1/8 N/A 220,000 1-5/8 7/8 1-1/8 7/8 1-5/8 3/4 1-3/8 N/A 250,000 1-5/8 7/8 1-3/8 7/8 1-5/8 7/8 1-3/8 N/A 300,000 1-5/8 7/8 1-3/8 1-1/8 1-5/8 7/8 1-3/8 N/A 360,000 2-1/8 1-1/8 1-3/8 1-1/8 2-1/8 1-1/8 1-3/8 N/A 420,000 2-1/8 1-1/8 1-3/8 1-1/8 2-1/8 1-1/8 1-5/8 N/A NOTES: 1. Line sizes are calculated assuming single scroll compressors in Models 051-201 and tandem scroll compressors in Models 271-421. Contact the factory for any other compressor configuration. 2. All piping must comply with standard refrigeration piping techniques. Consult the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Handbook-Refrigeration. 3. Suction, hot gas bypass and hot gas reheat lines should be insulated with a 5/8 minimum thickness closed cell foam insulation. Liquid line exposed to high ambient temperatures should be insulated with a 5/8 minimum thickness closed cell foam insulation. 4. Maximum suction line vertical lift is 60. Loop piping to the top of the coil. 5. Maximum liquid line vertical lift is 60. 6. If ordered, hot gas reheat and hot gas bypass require only one line. 7. Standard hot gas bypass is not recommended for use with greater than 75 of equivalent line length. Internal hot gas bypass should be used as an alternative. 8. Contact factory for applications with digital scroll compressors. 9. Contact factory for layouts requiring more than 75 of actual line length. 19

Thank you for your business! There are references on this document to various trademarks. All trademarks mentioned herein, whether registered or not, are the property of their respective owners. Weather-Rite LLC is not sponsored by or affiliated with any of the trademark or registered trademark owners, and make no representations about them, their owners, their products or services. Weather-Rite LLC is not sponsored by or affiliated with BACnet or LonWorks. These products (with the exception of the CGTH and UHA[X][S] 30-75) are not for residential use. This document is intended to assist licensed professionals in the exercise of their professional judgment. Weather-Rite LLC 1100 Seven Mile Road NW Comstock Park, MI 49321 Telephone: +1.612.338.1401 Fax: +1.616.784.0435 Toll Free: 1.800.589.3691 www.weather-rite.com 2017 Weather-Rite LLC All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems without written permission of Weather-Rite LLC. Printed in the USA WRRCADSGNA 0117 Rev B