INSTRUCTION MANUAL HETO CBN 8 / 18 / C Cooling Baths ID: IM.doc Revision 1

Similar documents
USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE.

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

PORTABLE ICE MAKER. Model: IM-124S INSTRUCTION MANUAL

ASPIRE Laboratory Aspirator

User manual. Fridge Freezer ZRT18100WA

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

Ui REFRIGERATOR SPEC SHEET

USING THE REFRIGERATOR COMPARTMENT

Instruction Manual. Refrigerator. Model: HS-65L

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 17 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 19

Refrigerator INSTRUCTION MANUAL W1BF17 & W1WF17

Tabletop Cooler. Installation and User Guide. Swan Service Helpline For model: SR12010 (all colours) SR12010_IM.indd 1 17/02/ :56

REFRIGERATED RECIRCULATORY COOLER

MODEL 7000 SUCTION UNIT

WHS-65LB1/WHS-65LW1/WHS-65LSS1

V 120 SG - V 160 SG. Instructions for use

CHILLER. Operator s & Installation Manual

LABORATORY ILLUMINATED FLOTATION BATH

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 15 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 17

4L Instant Water Boiler Instructions for Use

Cold Soak Filtration Test (CSFT) of Biodiesel. ASTM D IP PM EA - CEN N CGSB 3.0 No Range

User Manual. Chest Freezer ZFC26500WA

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

LARDER Instruction booklet

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Cabinet Refrigerators/Freezers Instruction manual

Bauknecht AG, Industriestrasse 36, 5600 Lenzburg,

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

CH250 AND CH251 CHILLERS

OPERATING INSTRUCTIONS FOR:

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Contents. For your safety About your product Installing your appliance Using your appliance Care & cleaning...

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

Solid Door Top Mount Reach-In Freezer

PC87 American Style Double Door Fridge Freezer Manual for Installation, Use and Maintenance

Instruction Manual Refrigerator-freezer

CHEST FREEZER HS225523

PRODUCT DESCRIPTION CONTROLS

Water Baths. with BioCote antimicrobial protection. Find out more!

CHEST FREEZER USER GUIDE LEC CF61LW

INSTALLATION AND OPERATING MANUAL

MD-MINI Dry Bath. Instruction Manual

REFRIGERAT A OR USE DF1-15 F ridge

ES-20 Orbital Shaker-Incubator

TCW 2000 Ice liner refrigerator and freezer PIJ

ER MANUAL FOR YOUR BAUMATIC

User Instruction &)+ 4: CFH110QB

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

Freestanding Wine Cooler Instruction Manual

Operations Manual VCS/VCR/VLS

SPR7-OS SPR601-OS SCR600L-OS SPR601-OSRC SCR600L-OSRC SP6DSSTB-OS

REFRIGERATOR USER S MANUAL MODEL: HS-306LN

Installation & Operations Manual for. MSC-A & MSF-A Model. Display Freezers. 5/16 Rev. A

HOW TO USE THE FREEZER COMPARTMENT PAGE 16

smeg LARDER Instruction booklet

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

PORTABLE AIR CONDITIONER

CFC-FREE CB-60/CB-80 Cryobath Low Temperature Bath. Thermo NESLAB Manual P/N U00551 Rev. 04/03/00. Instruction and Operation Manual

INSTALLATION AND OPERATING MANUAL

Slow Cooker. All Retro Models & Colours. Help line: v1.0. Retro_SlowCookers.indd 1 16/06/ :26

DynaQube Portable Sample Cooling Device

Shaking Hot Tubs. Orbital / Reciprocating Shaking Water Bath Liter 115V S 28 Liter 115V Liter 230V

BEFORE USING THE REFRIGERATOR PAG. 9 PROTECTING THE ENVIRONMENT PAG. 9 PRECAUTIONS AND GENERAL SUGGESTIONS PAG. 9

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

IQ/OQ Protocol Installation Qualification/ Operation Qualification zz FreeZone Stoppering Tray Dryer & Bulk Tray Dryer Freeze Dry Systems

AG2TEMP PRESTIGE SPECIAL REFRIGERATOR Model: AG2TEMP SPECIAL

Glass and Dishwashers AMX / AUX Series

Portable Refrigerator

TM585. Refrigerator - Freezer Operation manual. Contents

Retro Tall Freezer. Installation and User Guide. Swan Service Helpline For model: SR11040 (all colours)

CONTENT REFRIGERATOR MODEL: HBF130 HBF130S. * The manufacturer keeps on developing various types OPERATING INSTRUCTIONS OF.

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Glass Door Merchandiser Refrigerator and Freezer

Operations Manual VCC

CH750, CH751 & CH951 CHILLERS

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

Model No. NR-BU303 Series

Digital Heat Block User Manual

B 353 COFFEE BREWING MACHINES MACHINES A CAFE KAFFEEBRUEHMASCHINEN KOFFIEZETAPPARATEN

Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW)

Power Pack Service Manual

NEVER CHANGE ORIGINAL COMPONENTS WITH ALTERNATIVES.

Model:WHS-109FB1/WHS-109FW1/WHS-109FSS1

INSTALLATION AND OPERATING MANUAL

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

KF Fridge / Freezer User Guide

Incubating Shaker with Cooling

VISUAL DISPLAY DISPENSER OWNERS MANUAL

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

User Manual. Refrigerator ZRG16605WA

A few simple steps to ensure perfect water, every time.

BEVERAGE COOLER WITH DUAL TEMPERATURE ZONES INSTRUCTION MANUAL

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

ROTARY VACUUM EVAPORATOR RVO 004

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

INSTALLATION AND OPERATING MANUAL

Electric steam steriliser

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

INSTRUCTIONS. Installation, operation and care of HD SERIES HOT DELI DISPLAY CASES. MODEL HD5 Full-Service IMPORTANT READ BEFORE USING DISPLAY CASE

Transcription:

Revision 1 INSTRUCTION MANUAL HETO CBN 8 / 18 / 28-30 - 30 C Cooling Baths ID: 88872215

Page 2 / 9 INSTRUCTION MANUAL CBN 8 / 18 / 28-30 Important user information Please read this entire manual to fully understand the safe and effective use of this product. In case you have any comments about this manual we will appreciate receiving them at: Warranty and Liability HETO-HOLTEN A/S guaranties that the product delivered has been thoroughly tested to ensure that it meets its published specifications. The warranty included in the conditions of delivery is valid only if the product has been installed and used in accordance with the instructions supplied by HETO- HOLTEN A/S. HETO-HOLTEN shall in no event be liable for incidental or consequential damages, including without limitation, lost profits, loss of income, loss of business opportunities, loss of use, and other related exposures, caused by e.g. incorrect use of the product. Symbols used in this manual WARNING Used in case of danger of a serious accident or when documentation needs to be consulted. NOTE Used to direct attention to a special item. WARNING FIRE HAZARD Used in case of potential danger of fire. Copyright 2001 HETO-HOLTEN A/S Gydevang 17-19 DK-3450 Allerød Denmark Telephone +45 48 16 62 00 Fax +45 48 16 62 97 e-mail info@heto-holten.com Home page: http//www.heto-holten.com

CBN 8 / 18 / 28-30 INSTRUCTION MANUAL Page 3 of 9 Table of contents 1. Introduction... 4 2. Safety precautions... 4 3. Installation... 5 4. Recommended fluids... 5 5. Configurations... 6 6. Accessories... 6 7. Operations... 6 8. Typical applications... 7 9. Maintenance... 7 10. Technical data... 8 11. Appendix 1, Accessories... 9 Enclosure: Declarations of conformity

Page 4 / 9 INSTRUCTION MANUAL CBN 8 / 18 / 28-30 1. Introduction Information about this manual: This manual describes installation, use, and maintenance of the HETO COOLING BATHS type CBN 8-30, 18-30, and 28-30, with an operating range from 30 C to +100 C* continuously and up to +120 C* for shorter periods, using appropriate liquids to maintain a good temperature stability. *) Above ambient temperature only with use of heating thermostat. The only functional element is the cooling system. The Heto CBN -30 series cooling baths are high performance units. They combine the demand for high cooling power with low ultimate temperatures. The cooling baths have been specially designed to work together with the HETO HMT series thermostats, but can also be used together with previous Heto thermostats and other manufacturers products. Unit seen from the front and the rear: ID- label Drain Hose Mains Switch Fuses Opening for Air Circulation Mains Connection 2. Safety precautions The cooling bath is designed according to EN61010. This assumes that two separate faults do not occur simultaneously. The cooling bath therefore offers protection against a single fault. WARNING FIRE HAZARD A potential fire hazard exists when operating the bath with flammable fluids at temperatures above their respective flash point. Fluids with flash points below ambient temperature are particularly hazardous. WARNING When installing a thermostat with the cooling bath, ensure that the excess temperature protection is set no higher than 5 C below the flash point/boiling temperature of the liquid. See separate instruction manual for the thermostat.

CBN 8 / 18 / 28-30 INSTRUCTION MANUAL Page 5 of 9 3. Installation WARNING When working with extreme temperatures always use suitable personal protection equipment. The cooling bath must never work in ambient temperatures lower than +5 C and higher than +32 C. The cabinet has openings for air circulation. The openings must never be covered and there must always be sufficient room for air circulation around the cabinet, 100 mm is recommended. Since the unit is capable of achieving temperatures down to 30 C, precautions should be taken to avoid freezing of the liquid, which could damage the circulation pump on the thermostat. Use liquids recommended by HETO-HOLTEN A/S to secure maximum performance and avoid unnecessary problems. Check that the mains supply is in accordance with the specifications stated on the type label on the back of the unit and connect the power cord to a power socket with protective ground. Fill the bath with a suitable fluid 30 to 40-mm below the rim of the bath. Make sure that the drain is closed. If a thermostat is installed with the cooling bath, ensure that a possible stopcock on this unit is closed. See separate manual for the thermostat. For circulation through external circulation systems connect it to the outlet and inlet on the thermostat by means of insulated rubber hoses. The cooling bath is designed to fit under standard laboratory tables with a HETO THERMOSTAT installed. Do not position the bath closer than 10 cm from walls or other obstructions, as the bath require good air circulation around the unit to assure maximum performance. 4. Recommended fluids Liquid HETOCOLD (Isopropanol) HETOEXTREME Minimum temperature Maximum temperature Flash point temperature Max. cut out temperature Cat. No. -80 C -14 C +11 C +6 C 88924072 (Ethylenglycol) -20 C +95 C +120 C +115 C 88921512 Water +2 C +90 C N A +90 C - HETOWARM +90 C +150 C +237 C +180 C 88928001 (Glycol fluid)* *The bath can operate daily, but not continuously at 100-120 C. EN 61010 demands that the operating temperature must be at least 25 C below the flash point of the liquid being used. The excess temperature protection should be set no higher than 5 C below the flash point. HETO HOLTEN recommends that liquids with a flash point below ambient temperature should be stored and handled refrigerated.

Page 6 / 9 INSTRUCTION MANUAL CBN 8 / 18 / 28-30 NOTE The volume of some liquids varies due to thermal expansion when the bath temperature rises. Make sure that overflow is avoided. 5. Configurations 1. Without thermostat. In this case the bath will keep cooling the liquid until a state of equilibrium between the cooling power and the load from flasks and the surroundings around 30 C is reached. The approximate cool down time in minutes may be calculated from: Cool down time = T V k W 70, where T V k W = Temp start - Temp end in degrees Centigrade = volume of liquid in litres = 1 for water, 0.5 for alcohol = average cooling capacity between Temp start and Temp end. 2. With HETO HMT thermostat. In all cases the thermostat regulates the temperature in the bath by applying heat to the bath. See also the instruction manual for the thermostat. 3. With older HETO THERMOSTAT. A number of accessories is available, to allow the use of older HETO THERMOSTATS with the CBN cooling baths. See Appendix 1. See also the instruction manual for the thermostat. 4. Bath with thermostat from other manufacturers. Select the appropriate fixation clamp or bridge to place the thermostat securely on the bath. For operation, see the instruction manual for the thermostat. 6. Accessories A number of accessories is available, i.e. high inclined cover lids, flat cover lids, insulated cover lids, ring systems, and pp-balls. See appendix 1 for an overview of available accessories. 7. Operations Press the main switch on the front. The cooling bath starts. Press the main switch again to stop the cooling bath. NOTE If the bath is stopped for more than 5 minutes, the bath must not be switched on again until the temperature in the bath is above 0 C otherwise the cooling system may be damaged.

CBN 8 / 18 / 28-30 INSTRUCTION MANUAL Page 7 of 9 8. Typical applications 1. Freezing and cooling of tubes and flasks positioned directly in the bath even without a thermostat installed. An accessory rod for holding flasks and tubes is available. This application should only be used with liquids that will not freeze, as the temperature is not regulated. 2. Freezing and cooling of small flasks and tubes. 3. Thermostating of other apparatus as e.g. photometers, by external circulation of the liquid, through a HETO THERMOSTAT. 4. Thermostating of other vessels by application of heat exchanger and extra stirring. 5. Pre-freezing for freeze drying. 6. An accessory spin-freezer is available. 7. Testing of viscosity in different media. 8. Cooling of materials for instance metals, for destructive material testing. 9. Etc. 9. Maintenance Cleaning: Disconnect the main cable. It is essential that especially the air-cooled condenser is kept clean and free from dust to offer maximum performance of the cooling bath. The air-cooled condenser therefore must be carefully cleaned at least twice a year. Use a soft brush and a vacuum cleaner. Be careful not to damage the fins. Drain and exchange the liquid on a regular basis to avoid stability problems. The outer cabinet is made from polyester coated steel. It may be cleaned with a wet cloth soaked in mild detergent. When cleaning the front and rear panels be careful not to get liquid inside the compressor compartment, the cable connection or the main switch. The top plate and the inner bath are made from stainless steel. Although this type of steel is particularly resistant to chloride containing solutions it is important to avoid high concentrations of halogens - especially chloride (all types of stainless steels are prone to attack from chlorides). Even this highly resistant quality may show rust, often coming from rusting of deposits of ordinary steel or deposits from external sources. The corrosion resistance of the stainless steel is closely connected to the surface conditions, which therefore should be maintained at the original conditions. The stainless steel surface should be cleaned with water - if necessary with added detergent or alcohol. Deposits of rust and/or calciumcarbonate may be easily removed with nitric acid (10 %) on a cloth. Wear protection gloves when working with nitric acid.

Page 8 / 9 INSTRUCTION MANUAL CBN 8 / 18 / 28-30 Fuses: For safety purposes the cooling bath is equipped with fuses. The fuses are dimensioned in such a way that they will only break in case of a serious fault. The user may change the fuses but the unit should as soon as possible after such a failure is inspected by authorised personnel to determine the reason for the broken fuses. 10. Technical data General Description Cooling bath Cooling bath Cooling bath CBN 8-30 CBN 18-30 CBN 28-30 DxWxH [mm] 439x273x521 469x423x672 644x423x672 Weight [kg] 31 47 55 Required power supply [V / Hz] 230 / 50 230 / 50 230 / 50 Maximum Power consumption [W] 325 800 800 Insulation rate [mm] 50 50 50 Operating parameters Description Working Temperature Range [ C] -30..120 (100) -30.. 120 (100) -30.. 120 (100) Liquid Volume [L] 8 18 28 Cooling Capacity at +20 C 600 900 900 Environmental Description Temperature Range [ C] 5.. 32 Relative Humidity [%] 15.. 80 Protection Class IP 21D

CBN 8 / 18 / 28-30 INSTRUCTION MANUAL Page 9 of 9 11. Appendix 1, Accessories For more information and ordering numbers on the below mentioned, please contact your local HETO-HOLTEN representative. Bridges For fixation of thermostats on bath. Different bridges are available. Used together with the various lids, the bath is completely protected against evaporation and/or ambient effects on the bath. Flat cover lids Used together with a thermostat installed on a bridge when evaporation is to be avoided and the sample does not exceed the depth of the bath. The lids are made from AISI 304 corrosion resistant steel. Flat cover lids covering a bath completely Used when evaporation is to be avoided and the sample does not exceed the depth of the bath. The lids are made from AISI 304 corrosion resistant steel. High inclined cover lids Used when the samples exceed the bath depth and evaporation must be avoided. The lids are made from AISI 304 corrosion resistant steel and equipped with hinges and handle for easy and protected opening. All HETO BATHS except CBN 8-30 are equipped with pre-drilled holes/threads for hinge mounting. PP-balls and support rod The unique floating lid of plastic balls is often used when operating many different objects in the bath and evaporation is to be minimised. Allows a tight adaptation to any container type. The balls are chemical resistant and they are convenient to use. The support rod fits both CBN 18-30 and CBN 28-30 for easy retaining of flasks and accessories. Insulated cover lids Insulated lids are available for additional performance. They are recommended used when temperature is below 30 C to avoid icing up the bath. Spin-freezer Used for pre-freezing of samples where a thin layer of ice is essential e.g. during freeze-drying. The unit consists of a motor with variable speed, and shaft, and a 12V transformer. Lids with ring system Are used when evaporation from bath is to be minimised and sample supervision needed. The lids are made from AISI 304 and include a 2-ring system for 28L baths and a 1 ring system for 18L baths. Petri dish water bath incubator To be used for accurate temperature control of Petri dishes Ø100 mm. The outer cylinder is made from AISI 304 corrosion resistant steel, and includes a tray insert holding up to 9 dishes. Anti-float lead ring system To be used to avoid floating of flasks in baths with high liquid level. Universal plate fixation system Together with different clamps the universal system allows fixation of flasks, bottles, and racks in the cooling baths.