C A Heating Cable Gland Kit

Similar documents
JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

RayClic Connection System

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS

FTC-HST WARNING: CAUTION:

C Electrical Connection Kit

1SC-SSC Splice Connection Kit Installation Instructions

JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions

Gardian W51. Approvals

HS-TSPLICE - HEATSHRINK TEE / SPLICE. Installation Instructions

HEATING CABLE RATINGS APPROVALS* Drexan Energy Systems, Inc. Kelowna, BC, Canada, V4V 1S5

NELSON HEAT TRACING SYSTEMS

H908 WinterGard Plug-in Power Connection Kit with End Seal

Raychem Heating System

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Data Sheet. Self regulating process heating tapes RS stock numbers ,

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions

QuickStat-TC Installation & Operation Manual

Commercial and Residential Self-Regulating Heating Products

Data Sheet. Self regulating heating tapes. RS stock numbers

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS

Consignes d installation

SERGE BARIL GTKB GUT TRACE KIT BAG

NELSON HEAT TRACING SYSTEMS INSTALLATION

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

Retro-DWS Other Methods Internal Heating Cable System for Sewer Pipe and Waste Drain Applications

C910 Series. Single-point heat-tracing control system

NELSON HEAT TRACING SYSTEMS

Tyco Thermal Controls provides complete heat tracing and speciality. wiring solutions for the industrial, commercial, and residential markets.

XL-Trace System Application and Design Guide

NELSON HEAT TRACING SYSTEMS

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

NELSON HEAT TRACING SYSTEMS ALT-BC STANDARD POWER CONNECTION KIT

SEALING FIBER SEALING COMPOUND

NELSON HEAT TRACING SYSTEMS

XL-Trace System Installation and Operation Manual

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

Manual No: Revision: D. Sump Sensor. Installation Guide

SERGE BARIL HEAT TRACING SYSTEMS

FOSC. Fiber Optic System Technology. Fiber Optic Splice Closures (FOSC-400)

ACCS-30. Multipoint commercial heat-tracing control system

Manual No: Revision: E. Groundwater Sensor. Installation Guide

DESTU. Direct Entry Sealed Termination Unit. Installation Instructions. Suitable for use in either safe or hazardous areas.

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

KE-Series Constant-Wattage Heating Cable

Industrial Strength Leak Detection

QAA 142 Termination instructions Self-regulating trace heaters type ELSR-NA and -HA in Div1 with heater entry kit EL-HAZELECT Kit part No: 09CA051

NELSON HEAT TRACING SYSTEMS

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

PLSRR Heat Trace Cable Data Sheet

Self-regulating Roof Heat and Gutter Trace Cable

Toll Free:

HWAT -ECO. Installation and Operation Manual. Electronic controller for hot water temperature maintenance systems

Toll Free:

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

Technical Databook for Industrial Heat-Tracing Systems 2006/2007

Frost Heave Protection System Installation and Operation Manual

Self-regulating Roof Heat Cable

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

ST. KITTS CEILING FAN

Toll Free:

Installation Procedure for D-200 series Shielded Cable Splice Kits with MiniSeal Crimp Primary Splices

HVS S 15kV Class

TE Connectivity's AMP NETCONNECT Cable Management

Manual No: Revision: D. Mag Sump Sensor. Installation Guide

The DEF-System by BRUGG. The Best Way to defeat the problem of DEF heat Installation Instructions

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

DATASHEET PolySwitch RKEF Devices

Selection guide for self-regulating heat-tracing systems

Retro-DWS Internal Heating Cable System for Non-Pressurized Sewer and Waste Drain Pipes

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

EN RaychemRIM2StandardInstallationManual IM H /16 1

FIND LEAKS BEFORE THEY FIND YOU. Leak Detection and Location Systems

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Seal Kits for BUDI Enclosures

Fuel Leak Detection Find Leaks Before They Find You

TT3000 and TT5000 Series

Freezer Frost Heave Prevention

DRAIN WATER TEMPERING INSTALL

Union County Vocational - Technical Schools Scotch Plains, New Jersey

HVS S Splice Series

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty

PolySwitch TS600 Overcurrent Protection Devices

ITEM # , CARATUK RIVER CEILING FAN MODEL #40046, 40303

RF one-step BNC/TNC connectors for coaxial cable termination

IceStop System Installation and Operation Manual

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

ITEM # SAIL STREAM CEILING FAN MODEL #40048

Hot Water Temperature Maintenance. HWAT System. Product Selection and Design Guide

INSTALLATION INSTRUCTIONS. Aluminum Blinds - Standard - - Lift & Lock -

ITEM # SAIL STREAM CEILING FAN MODEL #41695

Transcription:

C75-100-A Heating Cable Gland Kit Installation Instructions Description The C75-100-A is a NEMA 4X rated gland kit used to transition heating cables into a junction box when making connections off of a pipe, tank or roof. It may be used for power, splice, or tee connections. The C75-100-A is for use with Raychem BTV-CR, BTV-CT, QTVR-CT, XTV-CT, KTV-CT (1), LBTV2- CT (2), VPL-CT industrial parallel heating cables and GM-XT roof and gutter deicing heating cables. The kit does not include the junction box, flexible tubing, or tape, which are required to make a complete connection. For technical support call Tyco Thermal Controls at (800) 545-6258. Tools Required Utility knife Wire cutters No. 2 Phillips or 1/4 (6 mm) slotted screwdriver For LBTV2-CT only: Heat gun or mini-torch Needle nose pliers Adjustable pliers Marker 3/16 (4 mm) or smaller slotted screwdriver Wire stripper (for VPL) Additional Materials Required Agency approved NEMA 4X rated junction box with 3/4" NPT threaded entry or through hole. Tape GT-66 Installation temperature above 40 F (5 C) GS-54 Installation temperature above 40 F ( 40 C) One length of flexible tubing, 6 ft (1 3/4 m) maximum, Raychem HCTE-1000-0 P/N 3679754004 (1) For KTV only: PMK-GP-10 grommet P/N 700823-000 (2) For LBTV2-CT only: HCS-100-A heat shrink core sealer P/N 257649-000 and PMK-GK-10 grommet P/N 222724-000 Approvals Hazardous Locations Class I, Div. 2, Groups A, B, C, D Class II, Div. 2, Groups F, G Class III Class I, Div. 2, Groups A, B, C, D Class II, Div. 2, Groups F, G 29ZL For BTV and LBTV2 heating cable systems only. Class I, Div. 2, Groups A, B, C, D GM-XT heating cable system only 877Z Non-Hazardous Locations De-icing and Snow Melting Equipment for GM-XT heating cable system only GM-XT heating cable system only Kit Contents Item Qty Description A 1 Red grommet B 1 Gland with threaded inserts C 1 Gland with screws D 1 Gland gasket E 1 Locknut F 1 Green/yellow tube G 1 CS-100 core sealer H 1 Terminal block A B C D H G F E WARNING: This component is an electrical device that must be installed correctly to ensure proper operation and to prevent shock or fire. Read these important warnings and carefully follow all of the installation instructions. To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged or improperly installed, and to comply with the requirements of Tyco Thermal Controls, agency certifications, and the national electrical codes, ground-fault equipment protection must be used. Arcing may not be stopped by conventional circuit breakers. Component approvals and performance are based on the use of Tyco Thermal Controls-specified parts only. Do not use substitute parts or vinyl electrical tape. The black heating cable core and fibers are conductive and can short. They must be properly insulated and kept dry. Damaged bus wires can overheat or short. Do not break bus wire strands when scoring the jacket or core. Keep components and heating cable ends dry before and during installation. Use only fire-resistant insulation materials, such as fiberglass wrap or flame-retardant foam. CAUTION: Health Hazard: Prolonged or repeated contact with the sealant in the core sealer may cause skin irritation. Wash hands thoroughly. Overheating or burning the sealant will produce fumes that may cause polymer fume fever. Avoid contamination of cigarettes or tobacco. Consult MSDS RAY5510 for further information. CHEMTREC 24-hour emergency telephone: (800) 424-9300. Non-emergency health and safety information: (800) 545-6258.

2 Heating cable types Braid Inner jacket Heating element Bus wire connection Clear jacket Insulated bus wire Outer jacket Bus wire Braid Inner jacket Conductive fiber Spacer Outer jacket Braid Inner jacket Conductive core Bus wire Outer jacket VPL-CT XTV-CT, KTV-CT GM-XT, BTV-CR, BTV-CT, QTVR-CT, LBTV2-CT 1 Select correct grommet from the chart below. Heating Cable Grommet GM-XT, BTV-CR, BTV-CT, QTVR-CT, XTV-CT, VPL-CT Red KTV-CT P* LBTV2-CT K* * Order separately WARNING: Use of the wrong grommet can result in leaks, cracked components, shock or fire, and will invalidate approvals and certifications. For LBTV2-CT a separate heat-shrinkable core sealer is required. Order one HCS-100 heat shrink core sealer. 2a For threaded junction boxes Mount box on wall or bracket. Install gland with threaded inserts into hub. For VPL heating cables only: Cut heating cable 12" (30 cm) from the center of the first indentation. 12" (30 cm) minimum Indentation (bus wire connection) Note: Use junction box with 3/4" NPT entry, only. Fully tighten gland into box and orient inserts to plane of heater, as shown. 15" (40 cm) Slide heating cable through gland and box until it extends 15" (40 cm) beyond outside edge of box as shown. Slide parts onto Use correct grommet (see Step 1) Flexible tube

3 2b For through hole junction boxes Mount box on wall or bracket. Install gland with gasket into box wall; secure with locknut. Lock nut For VPL heating cables only: Cut heating cable 12" (30 cm) from the center of the first indentation. Gasket Gland with inserts 12" (30 cm) minimum Indentation (bus wire connection) 15" (40 cm) Slide heating cable through gland and box until it extends 15" (40 cm) beyond outside edge of box as shown. Slide parts onto Use correct grommet (see step 1) Flexible tube 2c For GM-XT and threaded junction boxes (outdoor location) Thread the cap of the Y fitting with 3/4 NPT entry. Thread the gland fitting without the captive screws into the cap of the Y fitting. Note: If your installation requires that the heating cable be installed in flexible conduit as shown in 14B, add the appropriate amount of WARNING: This configuration is supporting the junction box with a nonmetal mounting gland. It may only be used where not exposed to a mechanical stress, impact, or static loading, such as protected by shield or out of the height range of people and moving equipment. 15" (40 cm) Slide heating cable through gland and box until it extends 15" (40 cm) beyond outside edge of box as shown. Thread junction box onto gland fitting. Slide parts onto Use correct grommet (see Step 1) Y fitting See 14b for details mm 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 inches 1 2 3 4 5 6 7

4 2d For GM-XT and through hole junction boxes (indoor dry location) Thread the cap of the Y fitting with 3/4 NPT entry. Thread the gland fitting without the captive screws into the cap of the Y fitting. Slide parts onto Note: If your installation requires that the heating cable be installed in flexible conduit as shown in 14C, add the appropriate amount of Lock nut Gasket Gland with captive screws WARNING: This configuration is supporting the junction box with a nonmetal mounting gland. It may only be used where not exposed to a mechanical stress, impact, or static loading, such as protected by shield or out of the height range of people and moving equipment. 15" (40 cm) Slide heating cable through gland and box until it extends 15" (40 cm) beyond outside edge of box as shown. Tighten lock nut to junction box on gland fitting. Use correct grommet (see step 1) Y fitting See 14c for details 3 Lightly score outer jacket around and down as shown. Bend heating cable to break jacket at score, then peel off jacket. Do not cut braid 7 1/2" (190 mm) mm 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 inches 1 2 3 4 5 6 7

5 5 4 5a VPL VPL Go to Step 5a Push braid back and bunch as tight as possible. XTV, KTV Go to Step 5b GM-XT, BTV, QTVR, LBTV2 Go to Step 5c Lightly score inner jacket around and down as shown. 6" (152 mm) Peel off inner jacket. Unwind heating element, cut and remove as shown. Lightly score clear jacket around and down as shown. 6" (152 mm) Bend heating cable to break jacket at the score then peel off jacket. Push braid forward. Use a screwdriver to open braid as shown. Bend heating cable and work it through opening in braid. Remove insulation from ends of bus wires. Pull braid tight to make pigtail. 1/2" (13 mm) Go to Step 6 mm 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 inches 1 2 3 4 5 6 7

6 5b XTV, KTV 5c GM-XT, BTV, QTVR, LBTV2 Push braid back to create a pucker. At pucker use a screwdriver to open braid. Push braid back to create a pucker. At pucker use a screwdriver to open braid. Bend heating cable and work it through opening in braid. Bend heating cable and work it through opening in braid. Lightly score base jacket around and down as shown. 6 1/2" (165 mm) Lightly score base jacket around and down as shown. 6 1/2" (165 mm) Peel off base jacket. Peel off base jacket. Notch core. Cut and remove all fiber strands. Peel bus wire from core. 1/4" (5 mm) Score and remove center spacer. Remove any remaining fiber material from bus wires. Pull braid tight to make pigtail. Score core between bus wires at inner jacket. Bend and snap core. Peel core from bus wire. Remove any remaining core material from bus wires. Pull braid tight to make pigtail. Go to Step 6 Go to Step 6 mm 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 inches 1 2 3 4 5 6 7

7 7 6 7 Mark the jacket as shown. CAUTION: Health Hazard. Wash hands after contact with sealant. Consult material safety data sheet RAY5510. 5/8" (15 mm) If needed, re-twist and straighten bus wires, then insert into the guide tubes as shown. Make sure all strands go into the tubes. Tubes 8 9 Push core sealer onto the heating cable to the mark made in step 6. Extra force may be required for larger cables or at lower temperatures. Remove the guide tubes and dispose of them in a plastic bag. Make sure the bus wires do not kink, bunch, or crossover. 10 1 " (25 mm) Apply 3 wraps of glass tape (Raychem GT-66 or GS-54). Slip the green/yellow tube onto the braid. Heat shrinking is not required. mm 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 inches 1 2 3 4 5 6 7

8 11a For threaded junction boxes Pull cable back through gland and box until tape is located just inside hub. Seat grommet in gland as shown. Position gland with screws next to grommet and tighten screws. Thread flexible tube onto gland. Install conduit and pull in power and ground wires for power connections. Tape (hidden) Grommet Flexible tube Gland with screws Gland with Inserts 11b For through hole junction boxes Pull cable back through gland and box until tape is located just inside gland with inserts. Seat grommet in gland as shown. Position gland with screws next to grommet and tighten screws. Thread flexible tube onto gland. Install conduit and pull in power and ground wires for power connections. Tape (hidden) Grommet Flexible tube Gland with screws Gland with inserts

9 9 12 Note the following instructions on bus wire preparation: For tee, install two wires in one terminal: - Twist appropriate wire pair together. - Trim twisted wires to 1/2" (13 mm). 1/2" (13 mm) 13 Connect bus wires and braid to terminal block. Connect power wires and ground wire to terminal block for power connections. This connection must be protected by a ground-fault equipment protection device. Otherwise, trim single wires to 3/8" (10 mm). 3/8" (10 mm) 14a Stow wires in box and install lid. Secure flexible tube with tape (Raychem GT-66 or GS-54). Tyco Thermal Controls recommends the use of a conduit drain to prevent water condensation build-up. Water tight conduit seal Flexible tube (HCTE-1000-0) Weather seal 6 feet maximum (1 3/4 m) Heating cable Thermal insulation Tape

10 14b For GM-XT and threaded junction boxes (outdoor location) Install the junction box either directly to the gland fitting in the cap of the Y fitting or to the end of the flexible conduit as shown below. Stow wires in box and install lid. WARNING: This configuration is supporting the junction box with a non-metal mounting gland. It may only be used where not exposed to a mechanical stress, impact, or static loading, such as protected by shield or out of the height range of people and moving equipment. Tyco Thermal Controls recommends the use of a conduit drain to prevent water condensation build-up. 14c For GM-XT and through hole junction boxes (indoor dry location) Install the junction box either directly to the gland fitting in the cap of the Y fitting or to the end of the flexible conduit as shown below. Stow wires in box and install lid. WARNING: This configuration is supporting the junction box with a non-metal mounting gland. It may only be used where not exposed to a mechanical stress, impact, or static loading, such as protected by shield or out of the height range of people and moving equipment. Worldwide Headquarters Tyco Thermal Controls 300 Constitution Drive Menlo Park, CA 94025-1164 USA Tel (800) 545-6258 Fax (800) 527-5703 info@tycothermal.com www.tycothermal.com Canada Tyco Thermal Controls 250 West St. Trenton, Ontario Canada K8V 5S2 Tel (800) 545-6258 Fax (800) 527-5703 Tyco and Raychem are trademarks or registered trademarks of Tyco Thermal Controls LLC or its affiliates. Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their particular application. Tyco Thermal Controls makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Thermal Controls' only obligations are those in the Tyco Thermal Controls Standard Terms and Conditions of Sale for this product, and in no case will Tyco Thermal Controls or its distributors be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Tyco Thermal Controls reserves the right to make changes without notification to Buyer to processing or materials that do not affect compliance with any applicable specification. 1997, 2000, 2002, 2004 Tyco Thermal Controls LLC Printed in USA PN 391663-000 H56343 08/04