HGM1750 Automatic Generator Module OPERATING MANUAL Smartgen Electronics

Similar documents
LXC31X0/LXC39X0 Series. Flywheel teeth configuration items increase (When genset has no magnetic sensor,please set to 5 to close magnetic sensor)

M2500 Engine Controller Installation Manual

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

DGC-500 DIGITAL GENSET CONTROLLER

DGC-1000 DIGITAL GENSET CONTROLLER

M2000 Engine Controller

Installation, Operating and Maintenance Manual

Intelligent addressable fire alarm control panel

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

20 Light Remote Annunciator

EL-OEM-3 OEM Packaged Voltage Data Logger

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

HRX Technical Manual. Version 1.2

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB-1-LCD Temperature Data Logger with LCD

EL-OEM-3 OEM Packaged Voltage Data Logger

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Specifications Minimum Typical Maximum Unit

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

EL-USB-TC Thermocouple Data Logger with USB Interface

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

HRX3000. Technical Manual

21-light Remote Annunciator. Owner s Manual

HART XL High Sensitivity Smoke Detection

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

Monitoring Solutions

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

ELMTEC. Kattreppeln Königslutter / /

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

UNC100 Integra Manual

Speed and Frequency Seite 1 von 7

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

Spectron LSN (Life Safety Network) Suggested Specifications

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

HART XL High Sensitivity Smoke Detection

Networked Access Control Panel. Installation Guide

FLOW CONTROLLER TYPE S/601

Excel-EN Conventional Fire Control Panel

Cimco Series 21. Series 21 - Operator Instruction Manual INDEX. Description. Standard Instructions 2 to 4. Operating Control Panel 5

Addressable and Conventional Fire Protection

MOBILE CALL GSM Alarm System User s Manual

MiLAB Oxygen Control MANUAL & INSTALLATION. MOC-100 Ver 3.0

Intelligent Wireless GSM Alarm System

NGC-40 Advanced Heat-Tracing Control System

Moulded case circuit brakers

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

System 800 Addressable Fire Detection & Alarm System

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

ONX908MTW-0/24V MULTI STAGE THERMOSTAT

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

LORAIN CIP 4890/48120 DC Power System

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

SC-F3G User Manual 1.0

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

PTE0705 Electric Fence Monitor

S/601 Controller Installation Manual

E1000 Portable gas detector

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Item Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22

IMR EX610. Portable Gas Detector. Operation Manual

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

Process & TeMPerATUre UniversAl input DigiTAl MeTers

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue


SENTINEL A - Fault Passage Indicator

Specification/ Data Sheet

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

T5000 LCD Digital Fan Coil Thermostat

Tachometer/Hourmeter/Trip. Installation and Operation Manual

An introduction to... Sigma

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

B-40/B-41 Modulating Temperature Controller

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

EKL3 short circuit and earth fault indicator

Sentry G3 Machinery Protection Monitor

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

STA16 SELECTRONIC ALARM ANNUNCIATORS DESIGN, INSTALLATION AND OPERATING MANUAL STA16

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

M2000 Engine Controller

30.45 Electric Release PDRP-2001

Transcription:

HGM1750 Automatic Generator Module OPERATING MANUAL Smartgen Electronics

CONTENT 1. SUMMARY...4 2. PERFORMANCE AND CHARACTERISTICS...4 3. SPECIFICATION...5 4. OPERATION...5 5. PROTECTION...6 6. PARAMETER RANGE AND DEFINE...7 6.1 PARAMETERS TABLE (TABLE 1)... 7 6.2 PROGRAMMABLE OUTPUT (TABLE 2)... 9 6.3 SENSOR (TABLE 3)... 9 7. CONNECTING TERMINAL...10 8. DIMENSIONS (PANEL CUTOUT 78*66MM)...11 9. INSTALLATION...11 HGM1750 Automatic Generator Module ISSUE2010-06-19 Version1.1 Page 3 of 11

1. Summary HGM1750Automatic Generator Module HGM1750 for a generator/engine protection modules that can display the electricity generating/engine parameters (such as voltage, speed, temperature, generator pressure, fuel oil, etc.), also can position in detecting faults (hydraulic cylinder, low temperature, high temperature/emergency stop alarm, speeding, etc.) during shutdown command. Graphical LCD panel parameter and instructions provide valid fault condition of fault alarm signal. 2. Performance and characteristics Using microprocessor as a core, graphics LCD with big screen and backlight, display and electrical parameters of oil and alarm. Precision measure and display of Generator voltage (V) Generator frequency (Hz) Generator temperature (ºC) Generator pressure (kpa) Speed (rpm) Generator hours count (h) Start battery voltage (V) Generator fuel level (%) Control protection: Oil pressure low High temperature warning, shutdown Low oil pressure warning, shutdown A low fuel oil warning High voltage power warning, shutdown Over frequency alarm shutdown Over speeding alarm shutdown Emergency shutdown Shutdown failure Charge failure Battery voltage high warning Battery voltage low warning Through the software can be aiming for engine controller (controller does not choose power voltage input). A panel installation has red light-emitting diodes (LED) work and alarm status. A generator excitation function battery can provide. A speed signal desirable frequency speed sensor or electricity. A multiple temperature, pressure and oil level sensor can use directly, and can be custom curve. A switch quantity with programmable input, according to the needs of user can choose different functions. A LINK through programming mouth with PC test software parameters settings (using the company's production SG72 adapter), only a PC USB interface, in really machine parameters can be set up, also don't battery, by a PC to working controller provides USB power parameter settings. A modular structure design, ABS plastic casing, embedded installation, HGM1750 Automatic Generator Module ISSUE2010-06-19 Version1.1 Page 4 of 11

compact structure, small volume, advanced MCU control, stable performance, convenient operation. 3. Specification Item Content Operating voltage DC8.0V to 35.0V, Continuous power supply Power consumption Waiting: 12V: 0.3W, 24V: 0.4W Work: 12V: 1W, 24V: 1.1W Alternator input range 1P2L 30VAC - 360 VAC (ph-n) Alternator input frequency 50/60Hz Magnetic input range 1V to 24V Magnetic input frequency Max 15kHz The biggest accumulative run time 99999.9 hour (After decimal point for1/10 hour, namely 6 minutes varied once). Stop relay output 7Amp Alarm relay output 7Amp Digital input Connect the B- valid Dimensions 88mm*76mm *44mm Panel cutout 78*66mm Operating temperature Temperature: (-30~70)ºC range Humidity: (20~90)% Storage condition Temperature: (-40~+80)ºC Protective level IP55: When the control panel mounted between waterproof rubber rings. IP42: When the control panel mounted between waterproof rubber rings is not. Insulation intensity Object: In between the input/output/power Reference standard: IEC688-1992 Test method: AC1.5 kv / 1min 1mA leakage current Weight 0.20kg 4. Operation display panel Item Define Description Page down /decrease Page down, or in setting parameter status, pressing this key will decrease setting value. Power Running Alarm Led Power indicator Operation indicator When report to alarm, LED display. When the power is normal light controller. When the engine start after the success of light. HGM1750 Automatic Generator Module ISSUE2010-06-19 Version1.1 Page 5 of 11

LCD ICO instruction Item Define Item Define WHT Run OPL Over speed alarm Emergency stop alarm Gens over volt Fail to stop Start battery voltage abnormity Aux Alarm Fuel level low Gens Volt Battery Volt Speed unit Oil press unit Volt unit Fuel oil level unit Temperature unit Freq unit Generator hours count 5. Protection 1. Low oil pressure warning/stop: after a successful start-up, delay 10 seconds to begin testing, low pressure and last 2 seconds after the alarm or stop. 2. High temperature warning/stop: after a successful start-up, delay 10 seconds to begin testing, high temperature and last 2 seconds after the alarm or stop. 3. Low fuel oil level warning: when a low fuel below a preset fuel continues for 10 seconds, low fuel bits, this value only warning signal, don't keep. 4. Over speeding alarm stop: when the alarm speed for more than 2 seconds after the preset alarming downtime. 5. High voltage generator outage warning stop: when sampling voltage over preset 5 seconds, warning or stop. 6. Generator over frequency alarm shutdown: when frequency for more than 2 seconds after the preset alarming shutdown. 7. High battery voltage: when the battery voltage over 10 seconds, preset a warning signal voltage battery, don't stop. 8. Lower battery voltage: when the battery voltage continue below the default values for 10 seconds, lower cell voltage warning signal, without stopping. 9. Emergency stop: when the emergency stop input, output, immediately to stop an emergency stop alarm signal. 10. Charging failure: starting, delay 10 seconds began testing, when charging machine D + (WL) voltage 3V below and lasts 5 seconds, charging failure alarming signals, don't stop. 11. Shutdown failure: when the alarm controller, on delay shutdown command, if still end on a warning, don't stop failure. 12. Common alarm: when over speeding, over frequency, over volt, high temperature, low oil pressure, emergency shutdown, shutdown failure, charging failure, battery over voltage, battery under voltage(pre-alarm), panel alarm lights flashing, alarm relay output. HGM1750 Automatic Generator Module ISSUE2010-06-19 Version1.1 Page 6 of 11

Description: The protection of the judge success when starting conditions: 1. When the oil pressure be more than 200kPa. 2. When generator frequency more than nominal value for 40% of the frequency, (When rated frequency for 50Hz, setting value for 20Hz). 3. When the engine speed more than 40% of the rated speed setting (600 R.P.M., when the rated speed for 1500RPM). If meet any more, think start-up success, while the protection. 6. Parameter range and define 6.1 parameters table (table 1) Num Parameter Range Default Remart 1 2 3 High temperature shutdown High temperature warning value Low oil pressure shutdown value (50-140)ºC 102 (50-140)ºC 95 (0-600)kPa 103 When the external temperature sensor is greater than this value, the temperature too high a temperature alarm the stop signal. When setting value equal to 140, not only a high temperature of the temperature sensor signal (not including temperature is exorbitant, switch quantity alarm signal). When the external temperature sensor is greater than this value, the temperature too high a temperature warning alarm, without stopping. When setting value equal to 140, not only a high temperature of the temperature sensor signal (not including temperature is exorbitant, switch quantity alarm signal). In the engine running process when external pressure sensor is less than the value of pressure, low pressure alarm the stop signal. When setting value equal to 0, not a low pressure (pressure sensor signal, not including low pressure switch quantity alarm signal). HGM1750 Automatic Generator Module ISSUE2010-06-19 Version1.1 Page 7 of 11

Num Parameter Range Default Remart In the engine running process when external pressure sensor is less than the value of pressure, low pressure 4 Low pressure warning alarm, without (0-600)kPa 124 warning value stopping. When setting value equal to 0, not a low pressure (pressure sensor signal, not including low pressure switch quantity alarm signal). When the external level sensor level than the value 5 and lasts 10 seconds, a Low fuel oil (0-100)% 10 warning signal low level, the level warning value only warning, when set to 0 not detection of low position of fuel. 6 7 8 9 10 Generator rated voltage Generator over voltage shutdown Generator over voltage warning value Generator rated frequency Generator over frequency value (80-300)V 230 (20-150)% 150 (20-150)% 115 (25-60)Hz 50 (20-150)% 115 The rated voltage phase generators. When power voltage values and above this lasts 5 seconds that power voltage, high voltage power outage warning. When set to 150% high voltage, detection signal. When power voltage values and above this lasts 5 seconds, namely that high voltage power generating over voltage warning, alarm, without stopping. When set to 150% high voltage, detection signal. The rated voltage phase generators. When the generator frequency than the value and lasts for three seconds that had made, and, when the stop signal frequency alarm set the value for 150, don't ever detection. 11 Generator pole (2-16)pole 4 A number of generators. 12 Flywheel teeth (10-300) 118 13 Engine speed rated (750~5000)r pm 1500 HGM1750 Automatic Generator Module ISSUE2010-06-19 Version1.1 Page 8 of 11

Num Parameter Range Default Remart 14 15 16 17 18 19 20 21 22 Over speeding shutdown Battery volt Battery volt over under ETS solenoid hold Programmable switch input Programmable switch input delay Select temp sensor Select press sensor Select liquid level sensor (20-150)% 115 (12-40V) 33.0 (4-30V) 8.0 (1-120)S 20 (0-7) 2 0-20.0S 2.0 (0-10) 06 SGD(120ºC) (0-10) 06 SGD(10Bar) (0-7) 0 Not used 6.2 Programmable output (table 2) Num Description Remarks 0 Not used External 1 warning input 2 alarm External shutdown alarm input 3 Reserved 4 Reserved 5 Reserved 6 Reserved 7 Reserved When the engine speed than the value and lasts for three seconds that a speeding, speeding the stop signal, when the alarm set to 150, don't test for speeding When generator battery voltage is over than the point and hold for 10seconds, battery over voltage signal is active. It s a warning alarm. When generator battery voltage is less than the point and hold for 10 seconds, battery under voltage signal is active. It s a warning alarm. It s the delay for energizing to stop. The factory default for: external downtime alarm input Programmable input port entered a valid delay time If the signal is valid only warning, non-stop If the signal generator, will stop immediately give an alarm 6.3 Sensor (table 3) Num Item Content Remark 1 Temperature 0 Not used Defined curve input HGM1750 Automatic Generator Module ISSUE2010-06-19 Version1.1 Page 9 of 11

Num Item Content Remark sensor 1 Digital input(low) 2 Digital input(high) 3 Defined curve 4 VDO 5 SGH 6 SGD 7 CURTIS 8 DATCON 9 Reserved 1 10 Reserved 2 2 3 Oil pressure Sensor Fuel oil level sensor 0 Not used 1 Digital input(low) 2 Digital input(high) 3 Defined curve 4 VDO 10Bar 5 SGH 6 SGD 7 CURTIS 8 DATCON 10Bar 9 Reserved 1 10 Reserved 2 0 Not used 1 Digital input(low) 2 Digital input(high) 3 Defined curve 4 SGH 5 SGD 6 Reserved 1 7 Reserved 2 resistance range is 0-999.9 ohm, default is SGD. Defined curve input resistance range is 0-999.9 ohm, default is SGD. Defined curve input resistance range is 0-999.9 ohm, default is not used. 7. Connecting Terminal Pin1 (B-): System DC negative input. (Battery Negative). Pin 2(B+): System DC positive input. (Battery Positive). Pin 3(Em. stop input): Plant Supply +ve. Also supplies fuel & start outputs. Pin 4 (Magnetic pickup): Head signal input, suggest using shielded wire, shielding layer one-port grounding. Pin 5 (Oil Pressure Switch): Low oil pressure switch input ports, connect to B - effectively. Pin 6(Engine Temp Switch): High temperature water/cylinder switch input ports, connect to B - effectively. Pin 7(Level Sensor): Liquid level sensor input, but circumscribed fuel level sensor. Pin 8(Oil Pressure Sensor): Oil pressure sensor input. Pin 9(Engine Temp Sensor): High temperature/temperature sensor input VAT. Pin 10(L) 11 (N): External generator voltage signal, the judge success and provide over clocking protect start-up. HGM1750 Automatic Generator Module ISSUE2010-06-19 Version1.1 Page 10 of 11

Pin 12(Aux Input): Programmable switch input ports, connect to B- effectively. Pin 13(D+ Input): After charging WL generator (or D +) terminals, internal controller provides charger exciter current. When the battery charging generator (i.e. failure in the operation process of the D + voltage < 3V), (Rechargeable battery failure alarming out when failure, only alarm). Pin 14(Alarm Output): Alarm output voltage output (B +) contacts capacity 7A. Pin 15(Stop Output): ETS solenoid to stop export (B + voltage output), Contacts capacity 7A. PC programming socket (LINK): Use SG72 programming cable connected to the PC USB parameter programming. 8. Dimensions (Panel cutout 78*66mm) 9. Installation HGM1750 Automatic Generator Module ISSUE2010-06-19 Version1.1 Page 11 of 11