Hazardgard. Product Profile. Engineered to perform in the harshest environments. Hazardous Location Room Air Conditioners

Similar documents
Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

Product Profile SINGLE PACKAGE VERTICAL AIR CONDITIONERS. Features

Service & Parts Manual

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Single Package Vertical Air Conditioners

Single Package Vertical Air Conditioners

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

14+ SEER R-410a AIR CONDITIONERS. Aluminum Coil Series. Efficiencies up to 14+ SEER/12 EER. Nominal Sizes Ton. Capacities 16.

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

MACH N-407 Heat Pump Air-Cooled Chiller

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

INSTALLATION & OPERATION GUIDE

Field Top Mounted Condensing Unit

MAC N-407 Air-Cooled Chiller

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

ProAir CR43 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

Horizontal Bottle Cooler Installation and Operation Manual

Model R060 Installation - Operation Manual

PTW 42 Series 230/208 VOLT

ProAir CR29 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Refrigerator Freezer Installation and Operation Manual

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

APPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS

Glass Door Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

5) Do not start or stop the unit by inserting or pulling out the power plug.

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL. Rev. F 2015 Pentair Equipment Protection P/N

Installation and Operations Manual

Ice Cream Freezer Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

M52 3-Phase INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Equipment Protection P/N

INSTRUCTIONS! DO NOT DISCARD!

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Installation & Operation Manual Ice Cream Freezers

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

PROAIR Air Conditioner

ProAir CR23 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

June PRODUCT DESIGN GUIDE Whisperline Console

OPERATION MANUAL. CLASSIC 10 and CLASSIC 18. Unit Serial Number Range: 1111XXXX### to Present (From November 2011 to Present)

THRU-THE-WALL AIR CONDITIONERS

BLOCK ICE MAKERS BY DELTA ICE, AIR AND HEAT INC.

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

POWER PACK SERVICE MANUAL

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Operator s Manual. IP-100 Immersion Probe Cooler

Superdryer Dehumidifiers

GENESIS Air Conditioner. M52 3-Phase Model INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

OPERATING INSTRUCTIONS

TECHNICAL SPECIFICATIONS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

INSTRUCTION MANUAL. T-SERIES Air Conditioner. T29 Model Pentair Equipment Protection P/N McLean Parts 5736 N. Michigan Rd.

INSTRUCTIONS! DO NOT DISCARD!

ion Genesis Pump Controller

Brasch Hazardous Location Unit Heaters

Power Pack Service Manual

13 GEP A L P - 1 A

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Quest Dry 105, 155, and 205 Dual

INSTALLATION AND OPERATING MANUAL

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

POWER PACK SERVICE MANUAL

User's Manual H-VC5. Chore-Logic. H-VC5 User manual. Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07. Page 1

GE Zoneline. vertical packaged terminal air conditioners Home Products and Services

User s guide RUH series Economical unit heater Replacement component list included

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Aluventa Design Guideline

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

Refrigerator Freezer Installation and Operation Manual

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

GETZ MANUFACTURING PART # CYLINDER DRYER


T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL. Rev. D 2015 Pentair Equipment Protection P/N

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

professional the the the

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

Transcription:

Product Profile Hazardgard Engineered to perform in the harshest environments Features Hazardous Location Room Air Conditioners Permanent split capacitor motor Hermetically sealed refrigeration system Environmentally sealed on/off switch and gold plated contacts in thermostat for corrosion resistance Solid-state control relays for compressor and fan operation Hot gas bypass allows the air conditioner to operate at low ambient conditions without freezing at outdoor temperatures as low as 45 F (7 C) Hermetically sealed reciprocating compressor is cooled during the refrigeration cycle, which allows the unit to tolerate higher outdoor temperatures up to 130 F (55 C) Larger, commercial grade, enclosed fan motor with hermetically sealed overload for arc-free operation. Field supplied, direct-wired, 15-amp circuit with time-delay fuse that will tolerate current surge without tripping the breaker 22-gauge, G60 steel air conditioner cabinet is powder coated for corrosion protection and to withstand years of hard use High density EPS foam insulation for thermal resistance and sound control Heavy duty hexacomb packaging resists damage during shipment and is environmentally friendly Coils coated for corrosion resistance 50 60 H E R T Z UL LISTED for CLASS 1, DIV 2, GROUPS A, B, C and D T4 / T4A Temperature Classification CERTIFIED in accordance with ISA 12.12.01 and NFPA 70 (NATIONAL ELECTRIC CODE), ANSI/UL 484 Room Air Conditioners KSA REGISTERED and TESTED in accordance with SASO

Model Identification & Specifications SH 15 M 20 A Series SH = Hazardgard Series Marketing Code Nominal Capacity (BTU) Voltage & Frequency 15 =15000 20 = 230/208V - 60Hz / 240/220V 50 Hz 20 = 20000 30 = 230/208V - 60Hz 24 = 24000 50 = 240/220V - 50 Hz M = Hazardgard Engineering Series Model Cooling Capacity Btu / Hr. Electrical Characteristics (60 Hertz) Volts - Frequency Rated Cooling Amps Cooling Watts Energy Efficiency Ratio ( EER) Moisture Removal (Pints/Hr.) Air Direction Controls Air Circulation (CFM) 60 Hz North America SH15M30A 14500/14000 230/208-60 6.9/7.5 1495/1443 9.7/9.7 4.0 8-way 375 SH20M30A 20000/19000 230/208-60 8.7/9.6 2125/2021 9.4/9.4 5.5 8-way 375 50 Hz / 60 Hz International / North America SH24M20 * 24000/23700 230/208-60 12.6/13.5 2727/2788 8.8/8.5 8.0/7.5 8-way 385 21000/20500 240/220-50 15.0 /13.2 2600/2412 8.1/8.5 7.0 /7.0 8-way 360 50 Hz International SH20M50A 19500/19100 240/220-50 9.8/10.3 2167/2156 9.0/9.0 5.6/5.5 8-way 425 Refrigerant: R 410A (all Models) Due to continuing engineering research and technology, specifications are subject to change without notice. Manufactured under U.S. Design Patent DES 368, 306 decorative front; Utility Patent 5, 622, 058. MAXIMUM outdoor ambient operating temperature is 130 F. (55 C) MAXIMUM TEMPERATURE RATING FOR CLASS I, DIVISION 2, GROUPS A,B,C,D. For global applications, Hazardgard cooling capacities are tested in a certified laboratory at moderate (T1*) and hot (T3*) climate conditions in accordance with SASO (Saudi Arabian Standards Organization) Standard 2681. SASO Standard 2681 is adopted from ISO Standard 5151 for testing and rating for performance of non-ducted air conditioners and heat pumps.

Features Hazardgard meets T4 temperature classification which means unit surface temperatures will not rise above 135 C/275 F. (note: 50/60Hz model listed as T4A for surface temperatures to 120 C/248 F). Operates at low ambient conditions without freezing at outdoor ambient temperatures as low as 7 C/45 F Tolerates higher outdoor temperatures up to 55 C /130 F Equipment is certified in accordance with ISA 12.12.01 and NFPA 70 (National Electric Code) ARTICLE 501 Class I, Div. 2, Group A and Group B Class I, Div. 2, Group B Class I, Div. 2, Group C Class I, Div. 2, Group D ARTICLE 505 Class I, Zone 2, Group IIC Class I, Zone 2, Group IIB plus hydrogen, or +H2 Class I, Zone 2, Group IIB Class I, Zone 2, Group IIA COILS COATED FOR CORROSION RESISTANCE MODEL SH24M20 ElectroFin 5-stage, immersion ecoat process on 100% of metallic surfaces on the outdoor coil provides outstanding corrosion resistance protection in coastal or corrosive environments ELECTROFIN BENEFITS: Excellent adhesion characteristics Less than 1% thermal degradation Outstanding chemical resistance Passed 6048 hrs.astm B-117 Salt Spray Test ELECTROFIN MEETS THE FOLLOWING: MIL-C-46168 Chemical Agent Resistance - DS2, HCI Gas CID A-A-52474A (GSA) MIL-STD 810F, Method 509.4 (Sand and Dust) MIL-P-53084 (ME)-TACOM Approval MIL-DTL-12468 Decontamination Agent (STB) DPG (Douglas Proving Grounds) Soil & Water Exposure Tests GM9540P-97 Accelerated Corrosion Test (120 cycles) ASTM B117-G85 Modified Salt Spray (Fog) Testing-2,000 hours ASTM B117 Salt Spray Test (tested by ARL for Lockheed Martin) MODELS SH15M30A, SH20M30A, SH20M50A Diamonblue Advanced Corrosion Protection on the outdoor coil protects the coil against deterioration and extends the life of the unit especially in coastal Hazardgard or corrosive Product environments Profile_2014

Installation Information Model Height Width Dimensions (Inches) Depth Overall A Depth J Box to Louvers B Minimum Extension Into Room Minimum Extensio n Outside Window Width (Inches) SH15M30A 15 15/16 25 15/16 27 3/8 6" 3 1/16 16 15/16 27 7/8 42 16 3/16 26 3/16 6" 250V - 15A 140 167 SH20M30A 17 15/16 25 15/16 27 3/8 6" 3 1/16 16 15/16 27 7/8 42 18 3/16 26 3/16 6" 250V - 15A (230V) 166 170 250V - 20A (208V) SH20M50A 17 15/16 25 15/16 27 3/8 6" 3 1/16 16 15/16 27 7/8 42 18 3/16 26 3/16 6" 250V - 15A 171 175 SH24M20 17 15/16 25 15/16 27 3/8 6" 3 1/16 16 15/16 27 7/8 42 18 3/16 26 3/16 6" 250V - 30A 180 185 Min Max In-Wall Installation Finished Hole (Inches) Height Width Max. Depth C Circuit Rating Breaker or T - D Fuse Volts - Amps Net Weight (lbs.) Shippin g

Electrical Requirements ALL FIELD WIRING MUST MEET THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (ANSI/NFPA 70) ARTICLE 501. THE FIELD-PROVIDED CIRCUIT PROTECTION DEVICE (HACR CIRCUIT BREAKER OR TIME DELAY FUSE) MUST NOT EXCEED THE AMPACITY INDICATED ON THE PRODUCT NAMEPLATE. IMPORTANT: Before you begin the actual installation of your air conditioner, check local electrical codes and the information below. Your air conditioner must be connected to a power supply with the same A.C. voltage and frequency (hertz) as marked on the data plate located on the chassis. Only alternating current (A.C.), no direct current (D.C.), can be used. An overloaded circuit will invariably cause malfunction or failure of the air conditioner; therefore, it is extremely important that the electrical power is adequate. Consult your dealer or Power Company if in doubt. The following instructions are for HAZARDGARD models and cabinet sizes listed below GROUPS CABINET SIZE (H x W x D) SMALL CHASSIS SH15 MEDIUM CHASSIS SH20, SH24 15 15 / 16 " x 25 15 / 16 " x 27 3 / 8 " (405 mm x 660 mm x 695 mm) 17 15 / 16 " x 25 15 / 16 " x 27 3 / 8 " (455 mm x 660 mm x 695 mm) Model Number Plug Type Circuit Rating Time Delay Fuse SH15 Junction Box 250V-15 Amp SH20, SH 24 Junction Box 250V-15 Amp

Hazardgard - EXTENDED COOLING PERFORMANCE Model SH15M30A SH20M30A SH20M50A SH24M20 (230 / 208 V - 60 Hz) SH24M20 (240 / 220 V - 50 Hz) OUTDOOR DRY BULB TEMP. (DEGREES F AT 40% R.H.) 75 85 95 105 110 INDOOR WET BULB TEMP. (DEGREES F AT 80 F D.B.) 72 67 62 72 67 62 72 67 62 72 67 62 72 67 62 BTUh 17052 16400 15182 16240 15312 14123 15602 14500 12833 14616 12978 11441 13811 12086 10665 WATTS 1220 1239 1253 1329 1343 1359 1495 1495 1495 1616 1615 1619 1689 1689 1695 AMPS 5.7 5.7 5.8 6.1 6.2 6.2 6.9 6.90 6.9 7.4 7.4 7.5 7.8 7.8 7.8 SHR 0.48 0.65 0.88 0.49 0.68 0.89 0.49 0.70 0.9 0.5 0.74 0.9 0.52 0.76 0.9 BTUh 23520 22620 20940 22400 21120 19480 21520 20000 17700 20160 17900 15780 19050 16670 14710 WATTS 1734 1762 1781 1889 1908 1932 2125 2125 2125 2297 2295 2301 2401 2400 2409 AMPS 7.2 7.2 7.3 7.8 7.8 7.8 8.7 8.70 8.7 9.4 9.4 9.4 9.8 9.8 9.8 SHR 0.45 0.61 0.83 0.46 0.64 0.84 0.46 0.66 0.85 0.48 0.7 0.85 0.49 0.72 0.85 BTUh 22932 22055 20417 21840 20592 18993 20982 19500 17258 19656 17453 15386 18574 16253 14342 WATTS 1768 1796 1816 1926 1946 1970 2167 2167 2167 2343 2340 2347 2449 2448 2456 AMPS 8.1 8.2 8.3 8.7 8.8 8.8 9.8 9.80 9.8 10.5 10.5 10.6 11 11 11.1 SHR 0.49 0.66 0.89 0.5 0.69 0.91 0.5 0.71 0.91 0.51 0.75 0.92 0.52 0.77 0.91 BTUh 28224 27144 25128 26880 25344 23376 25824 24000 21240 24192 21480 18936 22860 20004 17652 WATTS 2225 2261 2285 2424 2449 2479 2727 2727 2727 2948 2945 2953 3082 3080 3091 AMPS 10.4 10.5 10.6 11.2 11.3 11.3 12.5 12.60 12.7 13.6 13.6 13.6 14.2 14.2 14.2 SHR 0.42 0.57 0.76 0.43 0.59 0.78 0.43 0.61 0.78 0.44 0.64 0.79 0.45 0.67 0.78 BTUh 24696 23751 21987 23520 22176 20454 22596 21000 18585 21168 18795 16569 20003 17504 15446 WATTS 2122 2155 2179 2311 2335 2363 2600 2600 2600 2811 2808 2816 2938 2937 2947 AMPS 12.4 12.5 12.6 13.4 13.4 13.5 14.9 15.00 15.1 16.1 16.1 16.2 16.9 16.9 16.9 SHR 0.44 0.6 0.8 0.45 0.62 0.82 0.45 0.64 0.82 0.46 0.68 0.83 0.47 0.7 0.82 RATING POINT ANSI/ASHRAE 16

Friedrich Air Conditioning Company 10001 Reunion Place, Suite 500 San Antonio, TX 78216 800.541.6645 www.friedrich.com HAZARDGARD ROOM AIR CONDITIONERS LIMITED WARRANTY LIMITED ONE YEAR PARTS WARRANTY 1. Limited warranty One year. Friedrich warrants that it will provide a replacement for any part of this HazardGard Room Air Conditioner found defective in material or workmanship for a period of one (1) year from the date of original purchase. 2. Limited warranty One year. The Friedrich warranty also covers the cost of labor for repairing any compressor, condenser, evaporator or inter-connecting tubing found defective within the warranty period, provid ing the unit is returned to an authorized Friedrich Repair Station located within the Continental United States. The Friedrich warranty does not cover: LIMITATIONS: This warranty is a LIMITED warranty. Anything in the warranty notwithstanding, IMPLIED WARRANTIES FOR PARTICULAR PURPOSE AND MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESS WARRANTY. MANUFACTURER EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY. Performance of Friedrich s Warranty obligation is limited to one of the following methods: 1. Repair of the unit 2. A refund to the customer for the prorated value of the unit based upon the remaining warranty period of the unit. 3. Providing a replacement unit of equal value The method of fulfillment of the warranty obligation is at the sole discretion of Friedrich Air Conditioning.

Friedrich Air Conditioning Company 10001 Reunion Place, Suite 500 San Antonio, TX 78216 800.541.6645 www.friedrich.com INTERNATIONAL LIMITED WARRANTY TERMS OF LIMITED WARRANTY Friedrich Air Conditioning Co. warrants to the original purchaser that this Friedrich Air Conditioner is free from defects as to material and workmanship. This Warranty pertains to such manufacturing defects as may develop through normal usage and is in effect for a period of 12 months from date of installation or 18 months from the original date of purchase (date of invoice), whichever date shall occur first. The Company s obligation under this Warranty is limited to furnishing (FOB San Antonio, Texas no freight allowed), at its option, either a suitable replacement part or a remanufactured part or assembly for the sole purpose of replacing any part or parts which may be defective. All such warranty claims shall be directed through an authorized Friedrich Distributor/Dealer. Friedrich reserves the right to have the defective part returned to Friedrich for examination at the customer s expense. This Warranty does not apply to air filters, fuses, cabinet enclosures, refrigerant charge, and damage to any part resulting from installation not in accordance with manufacturer s recommendations; nor does it apply to exterior finishes, except where examination discloses that same was defective at the time of initial shipment. This Warranty also does not apply to a Friedrich Air Conditioner, or any part thereof, which has been subject to misuse, neglect, alteration, accident, flood, fire, or Act of God. No warranty shall apply if the product has been used on electrical circuits of voltage and cycle characteristics other than specified on the model and serial number plate. GENERAL TERMS The furnishing of replacement parts as described above shall constitute complete fulfillment of all obligations with respect to the Friedrich Air Conditioner. Under no circumstances does Friedrich assume any responsibility for service, labor costs, or transportation charges. THESE WARRANTIES ARE GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.