PRODUCT CONFORMITY CERTIFICATE

Similar documents
PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE AR500 Open Path Monitor with ER120

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

Low Temperature Zirconia Oxygen Analyzer

PRODUCT CONFORMITY CERTIFICATE

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

Instruction Manual July 2008 TS-2 TEMPERATURE SENSOR

multiranger 100 / 200

Level Measurement Continuous level measurement Ultrasonic transmitters

Continuous level measurement Ultrasonic transmitters

IR25 Dual Gas Series Datasheet

Instruction Manual April sitrans AS 100

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Instruction Manual August sitrans CU 02

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

INSTRUCTION MANUAL (ATEX / IECEx)

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Approvals, Certificates and Conditions

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

INSTRUCTION MANUAL (ATEX / IECEx)

SITRANS F M MAG 3100 P:

Level Measurement Continuous level measurement - Ultrasonic transmitters

INSTRUCTION MANUAL (ATEX / IECEx)

WIO200 Water In Oil measuring instrument

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

IECEx Certificate of Conformity

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

FUNCTIONAL SAFETY CERTIFICATE

WIO200 Water in oil sensor

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

IR15 Dual Gas Series Datasheet

Model 144H. Product Data Sheet , Rev DB February Content

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH. Instruction Manual August 2002

Flow Measurement SITRANS F C

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH

IRceL CH4 Methane (CH 4

Ultrasonic switch. Pointek ULS200. Quick Start Manual 03/2013. Milltronics

Non-Contacting Point Level Detection and Pump Control Sensor. Setting a New World Standard

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Rosemount 3100 Series Ultrasonic Level Transmitters

Model 144H. Product Data Sheet , Rev DB February Content

10yr O2NE & Safe-Ox. User Manual

General Routing Interface

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

SECTION : CAMPUS CENTRAL METERING SYSTEM DESIGN

SERIES 46000E Bi-Directional In-Line Deflagration Flame Arrester

I/A Series 716C 1/16 DIN Temperature Controller

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

PQS Independent type-testing protocol

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Series Temperature Controller Instruction Sheet

WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET

7NG , 7NG

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Technical data sheet TDS0060

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

PTE0705 Electric Fence Monitor

MICROpeL 75 Combustible Gas Sensor Part Number: PM

EC PARTS CERTIFICATE GB-1432

IEC SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR USE IN EXPLOSIVE ATMOSPHERES (IECEx SCHEME) INTRODUCTION

Loss Prevention Standard

IR1 Single Gas Series Datasheet

Technical data sheet TDS0034

Rosemount 3100 Series Ultrasonic Level Transmitters

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

SITRANS T temperature transmitters A broad product family for every application. sitrans

The evolution of accuracy in level measurement

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

3500/61E & 3500/67E Temperature Monitor

PQS performance specification

User Detection Sensors

UDC100 Universal Digital Controller Specifications

Certificate of EC type-examination of a measuring instrument Number: UK/0126/0077 Revision 1

Instruction Manual December 2001 ENACOCU02

Certificate: _02 / 22 March 2013

SS-100. Pyrometer. Temperature Range: 800~2400

LC1350 Level Controller

CERTIFICATE of Product Conformity (QAL1)

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

Declaration of Conformity

Temperature Data Logging

Standard ECMA th Edition - December Declared Noise Emission Values of Information Technology and Telecommunications Equipment

Transcription:

PRODUCT CONFORMITY CERTIFICATE This is to certify that the SITRANS LUT440 Ultrasonic Level Instrument manufactured by: Siemens Canada Limited Siemens Milltronics Process Instruments I IA SC PS 2 R&D TECHNOLOGY 1954 Technology Drive K9J 6X7 Peterborough ON, Canada Has been assessed by Sira Certification Service And for the conditions stated on this certificate complies with: MCERTS Performance Standards for Water Monitoring Equipment Part 3, Version 2.4 dated February 2013 Certification Ranges : 0 to 3m (nominal) Project No. : 16W27544 Initial Certification : 16 May 2013 R Cooper I Eng MInst MC Renewal Date : 15 May 2018 Technical Director MCERTS is operated on behalf of the Environment Agency by Sira Certification Service 12 Acorn Industrial Park, Crayford Road, Crayford Dartford, Kent, UK DA1 4AL Tel: +44 (0)1322 520500 Fax: +44 (0)1322 520501 Registered Office: Rake Lane, Eccleston, Chester, UK CH4 9JN Page 1 of 5

Approved Site Application Any potential user should ensure, in consultation with the manufacturer, that the monitoring system is suitable for the intended application. For general guidance on monitoring techniques refer to the Environment Agency Monitoring Technical Guidance Notes available at www.mcerts.net The product may be used on all MCERTS applications including abstraction, effluent discharge, ultraviolet disinfection and industrial processing. Basis of Certification This certification is based on the following Test Report(s) and on Sira s assessment and ongoing surveillance of the product and the manufacturing process: WRc test report number UC9452 MCERTS testing of Siemens LUT400 series ultrasonic level instruments. Product Certified The SITRANS LUT440 ultrasonic level measuring system consists of the following parts: SITRANS LUT440 ultrasonic level controller TS-3 external temperature sensor Echomax XRS-5 transducer Siemens sunshade (or equivalent) Unless permanently protected from direct solar radiation and/or at the discretion of the MCERTS inspector This certificate applies to all SITRANS LUT440 instruments fitted with software version 1.00.00-06 (serial number PBD/C1312131 onwards). Page 2 of 5

Certified Performance The instrument was evaluated for use under the following conditions: Ambient Temperature Range: Instrument IP rating: -20ºC to +50ºC IP65 The instrument meets MCERTS Class 1 requirements for the combined performance characteristic as specified in Table 7 of the MCERTS performance standard for the range 0 to 3m. Details of individual performance characteristics are summarised below: Results are based on the certification range 0 to 3m, unless otherwise stated. Test Results expressed as error % of certification range <0.1 <0.2 <0.5 <1.5 Other results MCERTS specification Protection against unauthorised access Password protected Clause 3.1.2 Units of measurement Indicating device Flow computation Combined performance characteristic 0 to 3m The indicating device and output are scaled in metric units The flowmeter incorporates an indicating device, analogue and digital output signal The flowmeter incorporates a facility for a user defined stage/discharge curve to be entered Note 1 0.20% Clause 3.1.6 Clause 3.1.3 Clause 3.1.11 Table 7 0.2% Class 1 Mean error 0 to 3m -0.05 Repeatability 0 to 3m 0.04 Resolution Supply voltage 10 to 32 V DC 0.007 Output impedance 50-750Ω <0.01 Ambient air temperature -20 C to +50 C 0.101 0.33 Clause 6.3.2 ±0.1% Class 1 Clause 6.3.2 ±0.05% Class 1 Clause 3.1.15 <2mm Class 1 Clause 6.3.3 0.025% Class 1 Clause 6.3.4 0.025% Class 1 Clause 6.3.6 0.25% Class 3 Direct solar radiation Accuracy of computation User defined stage-discharge equation 0.09 0.07 0.04 Note 2 Clause 6.3.10 0.15% Class 2 Note 3 Clause 6.3.11 0.075% Class 2 Note 3 Clause 6.3.12 0.075% Class 2 Warm up time The unit stabilises after energising within 60 seconds Clause 6.1.2 Page 3 of 5

Test Results expressed as error % of certification range Other results MCERTS specification <0.1 <0.2 <0.5 <1.5 Loss of Power for electronic flowmeters No changes in pre-set data Clause 6.3.1 Relative humidity 0.24 Clause 6.3.6 0.25% Class 3 Response time Note 4 <50s Clause 6.3.19 <30 seconds Error under field test conditions Error range +0.3% to +0.33% Field test error is <0.2% for 96% of readings Field test error is <0.5% for 100% of readings Note 2 Clause 7.3 0.2% Class 1 Up time 100% Clause 7.4 >95% Maintenance None Clause 7.5 Note 1: The combined performance characteristic reported is the root-sum-square addition of the maximum errors recorded in the following tests: mean error, repeatability, resolution, supply voltage, output impedance, ambient air temperature, direct solar radiation and accuracy of computation. Note 2: Direct solar radiation test and field trial were conducted with a sunshade in place, as per the manufacturer s recommendations. Note 3: Result reported as % of measured flow range. Note 4: Result based on medium response rate setting. Fast response rate setting result was 5s. Page 4 of 5

Description The SITRANS LUT440 High Accuracy OCM is the highest performing model of SITRANS LUT400 series controllers. It features a full suite of advanced pump control and alarm functionality, and enhanced flow data logging capability. Key applications include: wet wells, reservoirs, flumes/weirs, chemical storage, liquid storage, hoppers, crusher bins, dry solids storage. The SITRANS LUT440 is housed in a polymeric enclosure. As a system it is used in conjunction with a remote XRS-5 ultrasonic transducer and TS-3 temperature sensor. The SITRANS LUT440 transmits a pulse signal to the transducer that is then emitted as ultrasonic pulses. The pulses echo off the water surface and are then sensed by the transducer. The time for a pulse to echo back from the water surface is temperature compensated and converted into a measurement of head. The SITRANS LUT440 uses an algorithm to convert the head measurement into flow rate. The flow rate is totalised and stored in a data log to provide detailed flow analysis. Note: The XRS-5 transducer incorporates an integral temperature sensor that reports ambient temperature to the SITRANS LUT440, allowing it to automatically compensate the speed of sound for varying temperatures. In situations where the transducer is exposed to direct sunlight, or where variation in temperature of the sound medium is expected, a TS-3 temperature sensor is used. General Notes 1. This certificate is based upon the equipment tested. The Manufacturer is responsible for ensuring that on-going production complies with the standard(s) and performance criteria defined in this Certificate. The Manufacturer is required to maintain an approved quality management system controlling the manufacture of the certified product. Both the product and the quality management system shall be subject to regular surveillance according to Regulations Applicable to the Holders of Sira Certificates. The design of the product certified is defined in the Sira Design Schedule for certificate No. Sira MC 130226/00 2. If certified product is found not to comply, Sira Certification Service should be notified immediately at the address shown on this certificate. 3. The Certification Marks that can be applied to the product or used in publicity material are defined in Regulations Applicable to the Holders of Sira Certificates. 4. This document remains the property of Sira and shall be returned when requested by the company. Page 5 of 5