US Filtermaxx. 200,000 BTU Waste Oil Burner

Similar documents
Burner Comparisons. Typical Competitor s Burner

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

Columbia Boiler Company

A HEATER KIT With Diesel Engine Connection Fittings

MOUNTING INSTRUCTIONS

Troubleshooting the MPH 24FP Series Pedestal Hydrant

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

TWINTEMP JR. HYDRONIC SYSTEM 2/2013

INSTRUCTION MANUAL FOR OIL BURNER MODELS

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

PARTS MANUAL Model Numbers:

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Corn Flame Energy Corn Stove Model 3000

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Oil TRIANCO. EuroStar Range BURNER DETAILS TRIANCO - OIL BURNER. To be retained by householder

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D.

PORTABLE KEROSENE HEATER OPERATION AND MAINTENANCE INSTRUCTIONS. Model RCA-2800

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

Specifications 3. Bladder 5. Chimney 12. Air Supply 12. Anti-Rollout Device and Ash Auger Tube 14. Timer 15

SECTION AUXILIARY HEATER

LITTLE BLASTER SET-UP INSTRUCTIONS FOR SHOT PEEN MACHINES WITH CARTRIDGE TYPE DUST COLLECTORS *** READ BEFORE OPERATING EQUIPMENT***

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

SPECIFICATIONS PART NAME

CINCINNATI, OH USA

AquaMobil. Mobile shower, decontamination and heating systems SWINGTEC

Product Support Bulletin

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Waste Oil Fired Heater. Installation, operation and service instructions OWH v Manual

- 12 VDC. HHE M - 12 VDC.

Page 1 of 18. Part# /5/2013

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

CABS/BLADES/ SPREADERS/ACCESSORIES

Bosch 80% AFUE Gas Furnace BGS80 Model

Thermo 230 / 231 / 300 / 301 / Troubleshooting

HOME INSPECTOR EDUCATION EXPO 2016

ST 40 Oil Burner. Installation & Maintenance Manual

Manual update 2016 MC37/MFC3600

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-1000TR INDIRECT FIRED HEATER TRAILER

Econo Heater. Waste Oil Fired Heater. Installation, operation and service instructions EH v Manual. Manufactured by

Models: GW/R-T GW/R-2-T GW/R-3-T

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Eccotemp L5 and L10 Comprehensive Troubleshooting Guide

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Installation and Operating manual

Welcome! Today s topic: Small Home Repairs. November 14, 2015

15 20 kw kw kw

Thermal Stability Systems

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Engine Cooling Pulsator

Infrared Diesel Heater

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

WASTE OIL FIRED MOBILE RADIANT HEATER Operation and Service Instructions. Manual MODEL OWR-150

Model No.: VUM33AS20G

WATER PUMP REQUESTED INFORMATION STANDARD PROCEDURE RAM Pickup 6.7L Eng 2500 STANDARD PROCEDURE - COOLANT AIR EVACUATION

27" Gas Dryer MODELS: MGDB950YW3 (White) MGDB950YG3 (Cosmetallic) 05/31/ Maytag Part No. W Rev. A

HYDRO-HOT PARTS MANUAL

PROPANE INSECT FOGGER. Instruction Manual.

Far-infrared Oil Heater Owner's manual

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual

Installation Instructions / Warranty. Metris 31060XX XX XX1

Manual for MC91 SETUP INSTRUCTIONS

User s Manual & Safety Instructions Read Carefully Before Use

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

DewPoint 6210 Start-Up Checklist

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Utility and Utility System Floor Standing Condensing Oil Boiler Range ADDENDUM ATTENTION INSTALLERS - UPDATED INFORMATION!

Manual for MC37/MFC3600

USER S INFORMATION MANUAL

AmazonBasics Patio Heater B00LILH3V4 B00LILH47C B010VFKZEO

GV Series 4 Section Assembly

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

L24TWS. Beverage Tower Kit Components. L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

UPP7500E2 AUTOMATIC PRESSURE POT CLEANER

BEFORE OPERATING THE MACHINE: WARNING

AQUA-HOT PARTS MANUAL. Parts Manual. Model Numbers. AHE S - 12 VDC AHE X - 12 VDC AHE X - 12 VDC (SN: to 04533)

TECHNICAL INSTRUCTIONS

OPERATING MANUAL UG2000D SERIES SPRAY GUN CLEANERS UG2000D, UG2000DM UNI-RAM CORPORATION ONTARIO CANADA UG2000DM UG2000D REVISION

Detailed Cleaning Instructions

Heat Exchanger Block Replacement Instructions

G A S W A TE R /A G U A

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

HR Powder Feed Hopper

ENCLOSED UNIT TECHNICAL MANUAL Items # &

11.4 Component Assembly Diagrams and Parts Lists Case Assembly

Single stage operation oil burner

Transcription:

US Filtermaxx 200,000 BTU Waste Oil Burner

Assemble the Burner: Remove all the parts from the box. Locate the burner flange coupling and attach it to the front of the burner as seen in the photo below using the socket head screws from the parts bag. Note that the stand in the photo is for illustrative purposes only and is not included in the burner kit. Burner Flange Parts Bag Burner Flange Installed on Burner

The heated oil tank has two drains. One is an overflow tube that drains oil when it is too high in the tank. The other drain is located at the bottom of the tank and has a ball valve to manually drain oil and water from the tank. The threaded port in the center of the tank is for the ball valve. The tube is the overflow and a hose is attached at this point. The hose should drain back into the oil supply tank. As oil heats up, it expands and may rise up and dribble back down the tube to the supply tank. Locate the ball valve and wrap the threaded end with pipe sealant and screw it into the threaded port. As seen in the photo below.

Ball valve and drain tube located on the bottom of the burner. Locate the air regulator mount and attach it to the rear of the burner using the two screws located in the back of the burner. The air regulator is attached to the mount using the plastic nut on the regulator. This is not a heavy duty plastic nut and will not sustain much weight or twisting motion. The input thread is ¼ NPT. The empty compression fitting should be removed and a hose barb attached (not included). The air input hose and hose barb should be attached before attaching the assembly to the burner.

When the assembly is attached to the regulator mount, attach the output hose the burner. When you are sure that everything is lined up properly the threads on the plastic nut may be coated with epoxy and retightened for a permanent connection. Note that an air chuck connector is used in this photo is for demonstration only and a proper hose barb and hose should be used. Because the required air volume and pressure is low, about 20 PSI, ¼ inch fuel hose is suited for this application. The oil pump has in internal heater and becomes hot to the touch in operation.

Assemble the oil pump hoses using the soft aluminum crush washers between the couplings for a leak proof connection. Use a copper or aluminum washer on the heated tank for the hose adapter as seen in the photo below. Oil Input hose adapter and copper washer

The oil strainer may be in inserted after the supply tank and before the oil pump. Plug the oil pump in using the attached connector.

Wiring the plug: The burner requires 220 to 240 volts power input. Maximum Power required including tank heater, pump, pump heater and blower is 1000 watts. Typically the blower is the only electrical load with the others being intermittent. Power input is on the right 3 pin connector with the ground connection being in the middle. The left connection is burner on / off and should be connected to the thermostat switch. Attach the plug to the burner

Oil Reservoir Tank: The oil reservoir tank is located on the side of the burner and contains both a heater and float valve. The float valve regulates the height of oil in the tank. There is an over flow pipe to drain excess oil back to the storage tank. Float valve and heater coil in oil tank. Oil Reservoir Tank with Input line With the burner installed level, the oil should rise to nearly the top of the overflow pipe but should NOT drip from the burner nozzle. The float is already set for best operation however, if the oil level is too high, Turn the adjusting screw in so that the float stops the oil flow at a slightly lower level in the reservoir tank. Oil should NOT drip from the burner nozzle. Oil

expands when hot so be sure to check it when the oil it up to temperature. THE SUPPLY TANK MUST BE LOWER THAN THE BUNER OR SIPHONING MAY OCCURE, FLOODING THE FURNACE WITH OIL. The burner exhaust must be vented to the outside. Do not operate burner with exhaust venting into a closed building. Starting the Burner: The oil burner DOES NOT start immediately upon closing the run switch. Upon start up, the burner has a preprogrammed order of operations. 1. Feed pump starts and fills oil reservoir tank. 2. When the oil tank is full, the oil heater starts. 3. When the oil reaches the proper temperature, the fan starts. 4. The heater fan purges the nozzle and furnace for approximately 10 seconds 5. The electric ignitor starts. 6. The electric eye searches for light from a flame. 7. If there is light, the burner shuts down and the fault light comes on. 8. If no light is detected, the air valve opens and the burner starts. 9. If air pressure is between.35 and.45 bar, burner operates. 10. If air pressure is too high. Burner shuts down and fault light comes on. The burner will not operate in daylight due to the electric eye. Some oils may be difficult to light. Drain about 1/3 of the oil from the float tank and refill with diesel or heating oil. Once the burner is lit, the regulator may be adjusted for best oil flow and burn.

Burner Adjustments The burner operates between 80,000 and 200,000 BTU. It is adjusted for approximately 120,000 BTU upon arrival. To change the adjustment, remove the rear cover of the burner. The blower damper is adjusted using the allen key as seen below. For each complete revolution of the screw, the damper adjusts 1 number up or down. Oil is fed by siphon and the siphon is controlled by the compressed air input.

After the damper is adjusted, the oil feed should be adjusted for minimum smoke and maximum flame noise. Generally, the maximum air pressure should not exceed.45 on the pressure meter with typical operation being between.35 -.4. The burner will not start if the input air pressure is too high. Air pressure TO the regulator should be about 20 psi. or less. Oil Supply: Oil should be clean and free of debris, water and antifreeze. The burner will not operate properly if oil contains these contaminants. Oil should be settled and all contaminants removed. Difficult oil may be cut with diesel fuel, heating oil or kerosene. Contaminated oil is difficult to light, draining about 1/3 of the float tank and replacing with diesel allows you to light the burner. Adjusting the damper for high air flow and by adjusting the oil flow, oil with light antifreeze contamination may be burned. Once lit, burner should be left in the ON position cycling and relighting is difficult. Maintenance: Periodically, the air input tube should be disconnected from the rear of the burner tube cleaned with a shot or two of carburetor cleaner to remove deposits and coked oil. Using the ball valve, water should be drained from the float tank periodically. Boiling water in feed tank is an indication of contamination. The oil strainer should be cleaned to remove debris. The burner is warrantied for 1 year from date of purchase for defects in materials or workmanship. Malfunction due to improper installation, operation, fuel or maintenance is not covered under warranty. Burner should be installed and operated by qualified personnel only. US Filtermaxx liability extends to replacement of defective parts only. US Filtermaxx assumes no liability for

damages, injury or loss from use of this product. The buyer must follow all codes for installation and operation of the burner. The buyer agrees to these terms or must immediately return the burner for a refund. When the burner is in the off condition, radiated heat from the furnace may coke the nozzle. When possible, the burner should be set back a few inches. Coke should be cleaned periodically by removing the air input from the back of the COLD burner nozzle and giving a shot of, carb cleaner. Burner installed on a furnace fabricated from a scrap propane tank.

Fault Light: The fault light indicates bad ignition, too much air pressure or loss of flame. The fault light may be reset by turning off the power for 5 minutes, then pushing the reset button. Fault should be corrected before turning power back on. Disposing of contaminated oil: Oil with light water - antifreeze contamination may be disposed of using the burner. The float tank drain should be opened until the pickup screen on the front of the tank is visible. The tank should then be topped off with diesel or uncontaminated oil. The oil preheater should be turned up to maximum. The burner will light and the clean oil will heat the furnace. Once lit, the contaminated oil will refill the float tank and continue to burn. The burner will NOT cycle with contaminated oil and the burner should be left on until the contaminated oil is disposed of.