TABLE OF CONTENTS. DLM LED Emergency Light DLH LED Remote Heads DLP Wet Location LED Emergency Light...25

Similar documents
Exit/Emergency Lighting Guide

IOTA Exit Signs. IOTA Emergency Fixtures

NYC Approved Product Series

DISTRIBUTOR SELECT COLLECTION. EMERGI-LITE Full range of emergency lighting solutions

PRODUCT OFFERING QUALITY VALUE VERSATILITY

Exit Signs, Emergency Lighting & Fluorescent Emergency Ballasts

Nightfall. led emergency egress lighting

Architectural / led luminaires

NEMA-4X Series. Certified for Harsh Environment Applications

Distributor Select LED Families

Lights the way to safety SEVERE SERIES. Certified for Food Preparation and Cold Storage Applications. NEMA-4X Certified for Harsh Environments

HIGH BAY APPLICATIONS

Project. Comments. Prepared by. - EZ Hang feature facilitates fast - Prorated 5-year battery warranty - Overload / Short Circuit - NEC/OSHA

Project. Comments. Prepared by

Pictogram Exit Signs Catalogue

THE UNITED LIGHTING GROUP

SDL4 LED Strip Diffused Lens

BAS SDL8' LED Strip Diffused Lens

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

The New Lux-Ray LED Emergency Lighting

LED RETROFIT SOLUTIONS

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Sure-Lites. 13" [330mm] 3 1/8" [80mm] 4 3/4" [121mm] Emergency Light w/remote Capacity SEL SERIES

Dimensions (111mm) (111mm) 3 (76mm)

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

Step Lighting. For indoor and outdoor, stair and pathway applications. Juno Lighting Group Juno Step Lighting 1

Catalog Number. Notes

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

Emergency Lighting. Product Guide LED. The right source for the. right light

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

SECTION INTERIOR LIGHTING

BAS SFP22 Edge-lit LED Panel

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

LED Family Series. Low energy and low maintenance for moderate budget application LIFE SAFETY EQUIPMENT

Stocking Solutions. Downlights LED Panels Floods & Wall Packs

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

Max 4 Flush Lens RECESSED

Product Catalogue. Specialist in Emergency Lighting and Exit Sign

CHINESE NEW YEAR DEADLINE SOLUTIONS

Applications. Standard Materials

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

LED RETROFIT CONVERSION KITS

Choice of factory set distributions. Thermally set white polyester powder paint. Optional wet location listing

Pioneering Petroleum Canopy Lighting Since 1976

SOLID STATE ILLUMINATED RAIL

New LED Product Offerings

Grüv Flare Regressed. Recessed Linear LED

ARCHWAY TM PASSAGE TM

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

Spectron LSN (Life Safety Network) Suggested Specifications

BALLAST SOURCE EB- Electronic ballast BALLAST QUANTITY. 1-(1) 4-light ballast LAMP SPECIFICATIONS SPECIFICATIONS

Product Specifications MaxLumen MRI LED Diffused Lighting

LED RETROFIT CONVERSION KITS

IVR15-RPS O.D. Solid State Illuminated Rail Remote Power Supply

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

life safety products

Lighting Solutions. from a Leader in Light Source Technology

Product Specifications MaxLumen MRI LED Diffused Lighting

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

PRODUCT DATA SHEET LIGHTING PRODUCTS

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

Lighting & Ventilation

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Fire Escape Lighting Solutions. LED Emergency Back up Emergency Lights & Exit Signs Speciality Products

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

Bdl60u Fluorescent Emergency Ballast

How to light a small storage space rabdesign.ca 1

LED Lighting Product Guide. Spring A portfolio of industry-leading solutions that are changing the way we look at light.

EVLPF Series Compact Fluorescent

Lithonia Lighting LED Downlighting. A Solutions Guide For Every Need, Every Application, Every Budget

Grüv Flare Regressed. Recessed Linear LED

SPECIFICATIONS HYLYTR. with DOUBLE SLOT OPTICS

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

CALIBER LIGHTING. SERIES 4VDWWL Shower Lens LED Dim-to-Warm Recessed Downlight, 1018 Lumen APPLICATION PRODUCT DATA. 4VLEDWL Example: 4VLEDWLSCLPF

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

Catalog Number. Notes

Outdoor Emergency Lighting Application Guide

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

DHL-LP-LED Low Profile LED Linear High/Low Bay

Altman Lighting Spectra Cyc UV 50 Specification

UNIFIED FACILITIES GUIDE SPECIFICATIONS

CDL8 LED Architectural

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

Parking Garage. Lighting & Control Solutions SLGUS.COM

Introduction. Emergency Systems Synergy Control Systems. Lithonia Emergency Systems E3 - E16 Lithonia Synergy Control SS1 - SS9.

Explosion Proof Exit Sign - Class I, Division I - IP65-120V/277VAC - Emergency Battery Back-Up

LED FIXTURE CATALOG. Shining light into the future

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

Evolve LED Garage Light

KING LUMINAIRE The K902 Centurion Series Decorative Area Luminaire

Transcription:

ABOUT SIMKAR Simkar is a nationally known designer, developer, and manufacturer of innovative lighting solutions since 1952. We are committed to providing a diverse selection of high-quality LED lighting fixtures, along with other technologies earning us the reputation as one of the top manufacturers among contractors, specifiers, and other strategic partners. Our company was built on unwavering leading-edge lighting technology and customer excellence. Satisfied customers are at the heart of our company. Simkar offers nearly 5,000 lighting fixtures and is one of the largest single sources for residential, commercial, and industrial LED lighting. Our in-house research, development, and engineering departments employ design and engineering practices to produce high-quality luminaires with stellar performance all at a great value. At Simkar, our products offer the perfect balance of innovation and flexibility to meet the unique needs of our customers. Best yet, because of these innovative practices, many of our luminaires are DesignLights Consortium approved. We re proud to design and manufacture American made quality lighting fixtures at our 275,000 square foot manufacturing facility in Philadelphia, PA. Simkar has warehouse facilities located throughout the United States, and is strategically positioned to quickly and efficiently meet the production and distribution needs of our customers. OUR EXTENDED LINE OF LIGHTS Life safety is an integral component of every building s lighting system. Simkar s full line of Life Safety Exit and Emergency fixtures were designed to incorporate the newest and most dependable technology available to suit practically any application. Our line consists of exit signs, emergency lights, combination lights, remote fixture heads, inverters, and accessories units that can be used individually, or with remote heads. From die-cast aluminum to sleek, injection-molded, high-impact thermoplastic units, these well-designed units are low maintenance and provide the brightest light while using very little energy. Whether you re looking for specification grade, aesthetically pleasing architectural products for the most design conscious interiors; products for the most demanding hazardous and wet location or anything in between, we offer the right products to light the path to safety for every type of public building. Our high quality, reliable exit and emergency products are now even easier to maintain when equipped with the Self-Diagnostic (SD) option. SIMKAR s Self Diagnosing option employs a programmed integrated circuit chip to continuously monitor and test the system to ensure proper performance in the event of an emergency. In addition to the standard product line, we also offer exit signs and emergency lights that conform to the Chicago Code, as well as New York Approved fixtures. To serve you better, most Simkar products are in stock and available for delivery in one week or less.

TABLE OF CONTENTS IMIC Micro Emergency Power Systems................ 4 IMIN Mini Emergency Power Systems................. 6 Self Diagnostic (SD)...................... 8 SLED LED Exit Light............................ 9 DLR Slimline Exit Light...........................10 SDC Die-Cast Aluminum LED Exit Light.................11 SEL Edgelit LED Exit Light...................12 DLEL Edgelit LED Exit Sign........................13 SREL Recessed Edgelit LED Exit Light..................14 DLW Wet Location LED Exit Light....................15 SCLD LED Dual Head Exit/Emergency Light..............16 SCLI Exit and Emergency Combination Light..............17 SCLB Lightbar Remote Capable Combo Exit & Emergency Light..18 DLWC Wet Location LED Exit & Emergency Combination Light... 19 SEM Emergency Light...........................20 SFOEMLED LED Fixed Optics Emergency Light............21 SFOEM Incandescent Fixed Optics Emergency Light........ 22 DLM LED Emergency Light........................23 DLH LED Remote Heads..........................24 DLP Wet Location LED Emergency Light................25 SDBEL Outdoor LED AC/Emergency Light...............26 SHDLEDCA LED Heavy Duty Emergency Light Chicago Approved..27 SELNY Aluminum LED Edgelit Exit NYC Approved..........28 SXTEUNY Steel LED Exit Sign NYC Approved.............29 SDCNY Diecast Aluminum Exit Sign NYC Approved.........30 SRELNY Recessed Aluminum LED Edgelit Exit NYC Approved... 31 SCLDNY Steel Combo Emergency Exit NYC Approved........32 SHDLEDNY Heavy Duty Steel Emergency Light NYC Approved.. 33 SXTEUCA Chicago Approved Steel Exit Sign.............34 SELCA LED Exit Sign Chicago Approved................35 SRELCA LED Edgelit Exit Sign-Recessed Mount Chicago Approved... 36 SCLDCA Steel Exit Sign Chicago Approved..............37 Exit and Emergency Accessories...................38 Exit and Stair Configuration Diagrams...............39

IMIC Micro Emergency Power Systems IMIC Micro Inverters are designed for indoor installation in commercial or industrial applications. IMIC will provide emergency AC power to lighting fixtures equipped with incandescent, linear compact fluorescent, or LED lamps, up to 55W. IMIC Series inverter systems are designed to provide sinusoidal AC emergency power to connected incandescent, fluorescent, or LED fixtures between 20 and 55 watts. Surface, recessed, or ceiling T-Grid mount models are designed for easy installation either on or near controlled fixtures. IMIC models support Normally-ON, Normally-OFF, switched operation or any combination thereof. All IMIC systems will provide emergency power output for a minimum of 90-minutes. Heavy duty steel cabinet is finished in white baked-on powder paint providing scratch and corrosion resistance. Optional paint color (-SP) finishes available, consult factory. Input: Input Voltages: 120 or 277VAC ±10%. Input Frequencies: 60Hz ±2%. Input Protection: Provided by Service Panel, Rated 20A max. Output: Output Voltages: 120 or 277VAC (60Hz) Efficiency Rating: 98% at full rated load (line) Waveform: Sinusoidal (digitally controlled, PWM design) Static Voltage: ±5% during battery discharge. 0-100% linear load. Output Frequencies: 60Hz. ±0.3Hz during emergency cycle Output Distortion: Less than 3% THD (linear load) Transfer Time: Less than 1.0 second Load Power Factor Range: 0.44 Lead to 0.44 Lag Minimum Loading: 0% of rated system capacity Output Protection: Inverter fuse Surface, Recessed, or T-Grid mount models On during emergency conditions regardless of local switch position circuit fuse protected Reverse battery and AC lockout protection Unit: (excluding lamps) Full coverage against defects in materials and workmanship for 3 years from date of shipment. : 3 years (Lead-Acid-5 yrs NiCd) full warranty plus an additional 7 years of pro-rata coverage. Listings All models are UL924 Listed and meet NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. Optional T-Grid models are plenum rated. Surface Mount: Surface mount models are designed for mounting to walls by means of keyhole slots provided in the back of the unit housing. Recess Mount: Recess models provide recess mounting holes on both sides of the enclosure. T-Grid Mount: design allows simple drop-in installation between T-Grid runs. Safety wires (supplied by others) are required for attachment to building structure. 4

TEST AC CHG INV PUSH ON ON ON System Monitoring Panel All IMIC systems provide a monitoring panel on the front of the unit to show operating status at all times. The panel provides a test switch for user initiated system tests and a 3-LED array that provides an intuitive visual indication of unit readiness. Improved Aesthetics The IMIC system s sinusoidal AC output design eliminates voltage drop and proximity concerns. This allows added flexibility in installation location as IMIC units can be installed hundreds of feet from the units they power. This means IMIC units can be located conveniently out of sight in closets or utility rooms without interrupting architectural aesthetics. In lighting applications, no special or additional emergency fixtures are necessary. Simply designate and connect existing lighting fixtures, either interior or exterior, to the IMIC unit for emergency operation eliminating the need for exposed, standalone emergency luminaires. IMIC Micro Emergency Power Systems Configuration Series Wattage* ** IMIC 20 = 20W 32 = 32W 35 = 35W 55 = 55W S = Surface Mount R = Recessed Mount T = Plenum Rated Ceiling T-Grid Mount SP = Special (specify) **Notes: Other options available. Consult factory. Some options may impact product UL listing. Consult factory. Standard Surface Mount IMIC System Advantages Compared to traditional discrete emergency lighting units, the IMIC Series provides emergency illumination from a single power source resulting in lower maintenance overhead and routine testing expenses. IMIC units lower installation costs by powering existing lighting fixtures during emergencies. Because the connected fixtures are driven at full brilliancy, they provide far superior egress lighting and deliver improved occupant safety. Recessed Mount 7 3/8 16 1/4 1/2 Extrusion from wall after installation 14 3/4 4 3/8 3 1/8 (models IMIC35 & IMIC55) (models IMIC20 & IMIC32) T-Grid Mount 4 3/4 8 9/16 8 23 7/8 6 3/16 5

IMIN Mini Emergency Power Systems IMIN Mini Inverters are designed for indoor installation in commercial or industrial applications. IMIN will provide emergency AC power to lighting fixtures equipped with incandescent, linear compact fluorescent, or LED lamps, up to 220W. Can install up to 1,000 feet from controlled fixture(s) Emergency fixtures can be ON, OFF, or SWITCHED Long life, maintenance-free lead-calcium battery Unit capabilities up to 220W IMIN Series Mini-electrical inverter systems for powering up to 220W/250VA of incandescent, fluorescent, induction, or LED lighting loads. Pulse width modulated (PWM) output design provides clean, 60Hz sinusoidal emergency power to loads. Models are available for surface, recessed, or T-Grid mounting as required. All IMIN systems will provide emergency power output for a minimum of 90-minutes. Heavy duty steel cabinet is finished in white bakedon powder paint providing scratch and corrosion resistance. Optional paint color (-SP) finishes available, consult factory. Input: Input Voltages: 120 or 277VAC ±10 Input Frequencies: 60Hz ±2% Input Protection: Provided by Service Panel, Rated 20A max. Output: Output Voltages: 120 or 277VAC (60Hz) Efficiency Rating: 98% at full rated load (line) Waveform: Sinusoidal (digitally controlled) Static Voltage: ±5% during battery discharge. 0-100% linear load. Output Frequencies: 60Hz. ±0.3Hz during emergency cycle Output Distortion: Less than 3% THD (linear load) Transfer Time: Less than 1.0 second Load Power Factor Range: 0.44 Lead to 0.44 Lag Minimum Loading: 0% of rated system capacity Output Protection: Line and inverter fuse Unit: (excluding lamps) Full coverage against defects in materials and workmanship for 3 years from date of shipment. : 3 years full warranty plus an additional 7 years of pro-rata coverage. Listings All models are UL924 Listed and meet NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. Optional T-Grid models are plenum rated. Surface Mount: Surface mount models are designed for mounting to walls by means of keyhole slots provided in the back of the unit housing. Recess Mount: (IMIN-55/125, IMIN-110/125 Only): Recess models provide recess mounting holes on both sides of the enclosure. T-Grid Mount: (IMIN-55/125, IMIN-110/125 Only): design allows simple dropin installation between T-Grid runs. Safety wires (supplied by others) are required for attachment to building structure. 6

TEST AC CHG INV PUSH ON ON ON System Monitoring Panel All IMIN systems provide a monitoring panel on the front of the unit to show operating status at all times. The panel provides a test switch for user initiated system tests and a 3-LED array that provides an intuitive visual indication of unit readiness. Improved Aesthetics The IMIN System s sinusoidal AC output design eliminates voltage drop and proximity concerns. This allows added flexibility in installation location as IMIN units can be installed hundreds of feet from the units they power. This means IMIN units can be located conveniently out of sight in closets or utility rooms without interrupting architectural aesthetics. In lighting applications, no special or additional emergency fixtures are necessary. Simply designate and connect existing lighting fixtures, either interior or exterior, to the IMIN unit for emergency operation eliminating the need for exposed, standalone emergency luminaires. IMIN Emergency Power Systems Configuration Series Wattage* ** IMIN 55/125 = 55W( T ) 110/125 = 110W( T ) 110/250 = 110W 220/250 = 220W S = Surface Mount R = Recessed Mount T = Plenum Rated Ceiling T-Grid Mount SP = Special (specify) 4C = 4 Output Circuit Switching **Notes: Other options available. Consult factory. Some options may impact product UL listing. Consult factory. T Option available with IMIN-55/125 and IMIN-110/125 models only. Surface Mount IMIN System Advantages Compared to traditional discrete emergency lighting units, the IMIN Series provides emergency illumination from a single power source resulting in lower maintenance overhead and routine testing expenses. IMIN units lower installation costs by powering existing lighting fixtures during emergencies. Because the connected fixtures are driven at full brilliancy, they provide far superior egress lighting and deliver improved occupant safety. Recess Mount Optional Recessed Mount Hardware 13 1/8 7 3/8 16 3/4 6 3/8 4 3/8 T-Grid Mount 18 1/8 4 3/4 (Models IMIN- 220/250 & IMIN- 110/250) (Models IMIN- 55/125 & IMIN- 110/125) 8 8 9/16 23 7/8 6 3/16 7

Self-Diagnostic (SD) Option Self testing exit signs are effortless fixtures that complete routine monthly maintenance on their own. Make your life easier with self testing exit signs. Self-Diagnostic (SD) Option Our high quality, reliable exit and emergency products are now even easier to maintain when equipped with the Self- Diagnostic (SD) option. SIMKAR s Self Diagnosing option employs a programmed integrated circuit chip to continuously monitor and test the system to ensure proper performance in the event of an emergency. The SD system also automatically performs the required NFPA and NEC code compliant testing of 15-minute battery discharge every 30 days and 90-minute full discharge every 12 months. The SD system automatically recharges the unit s battery and displays a system diagnosis via an LED indicator light. SD also eliminates the physical test of emergency products. Since the LED indicator light provides a visual display, documentation of emergency lighting performance is as easy as a monthly walk through the building. SD is an economical solution to comply with safety codes and ensure emergency preparedness. Look for the SD option on the following products: SLED LED Exit Lights, SDC Die-Cast Exit Lights, SEL Edgelit LED Exit Light, DLEL Edgelit LED Exit Sign, SREL Recessed Edgelit LED Exit Lights, DLW Exterior Exit Sign, SCLD LED Dual Head Exit/ Emergency Light, SCLI Combo LED Exit/Emergency Lights, SCLB Lightbar Remote Capable Exit/Emergency, DLWC Wet Location LED Exit/Emergency Sign, SEM Twin Head Emergency Lights, DLM LED Emergency Light, SDBEL Outdoor LED AC/Emergency Light, SELNY Aluminum LED Edgelit Exit NYC, SDCNY Diecast Aluminum Exit Sign NYC, and SRELNY Recessed Aluminum Edgelit Exit NYC. Steady Green = OK Steady Red = disconnected Red Flash/Green Flash = Recharging Continuous Red Flashes = Recharge Failure 2X Two Continuous Blinks = Failure 4X Four Red Blinks = Lamp Failure 8

Ultra bright and energy efficient Self-Diagnostic (SD) option available Back or Canopy mount 5 Year SLED LED Exit Light This is our best-selling LED exit light for use in all types of commercial applications. It s inexpensive to operate and virtually maintenance-free. SD: Self-diagnostic feature performs monthly, biannual, and annual tests to ensure reliable operation and meet electrical and Life Safety Codes. 2C: Dual circuit option on the AC-only unit enables it to be connected to two different (one acting as a back-up to the other) supplies at the same time. CUSTOM: Signs available with requested special wording. Ultra-bright, energy efficient, long lasting Red or Green LED. Standard: EZ snap out Chevron directional indicators. Injection-molded, engineering grade, 5VA flame retardant, highimpact resistant, thermoplastic in white or black finish. Compact, low-profile design. Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-to-test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations (0 C 50 C). Certified to CEC under Title 20 Regulations. Internal solid state transfer switch automatically connects the internal battery to LEDs for minimum 90-minute emergency illumination. Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. 4.8V long life, maintenance-free, rechargeable NiCd battery. EZ-snap mounting canopy included for top or end mount. Universal K/O pattern on back plate for wall mount. 5 year limited warranty on all electronics and housing. pro-rated for five years. SLED Series Ordering Information 12-3/4 4-5/16 Series Letter Signage SLED A = AC B = Backup R = Red G = Green (Blank) = Exit SALIDA = Salida 2C = Dual Circuit (AC Only) 2 SD = Self-Diagnostic 1 CUSTOM = Custom Wording 1 Available only with B units. 2 Available only with AC units. 8 1-3/4 9

DLR Slimline Exit Light This thin thermoplastic exit sign offers softer lines and rounded edges to make it an attractive alternative to conventional rectangular signs. 5VA flame retardant Dual 120/277 voltage operation EZ snap-out Chevron directional indicators 5 Year Injection-molded, engineering-grade, 5VA flame retardant, high-impact resistant, thermoplastic in white or black finish. Aesthetically pleasing with curved face and rounded corner design. Standard: EZ snap out Chevron directional indicators. 1.2V Long-life, maintenance-free, rechargeable NiCd battery. Dual 120/277 voltage. Charge rate/ power ON LED indicator light and push-to-test switch for mandated code compliance testing. I Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations, 32 F (0 C) 122 F (50 C). Certified to CEC under Title 20 Regulations. Internal solid state transfer switch automatically connects the internal battery to LEDs for minimum 90-minute emergency illumination. Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. EZ-snap mounting canopy included for top or end mount. Universal K/O pattern on back plate for wall mount. 5 year limited warranty on all electronics and housing. pro-rated for five years. Ultra-bright, energy efficient, long lasting Red or Green LED. 5½ 4 5 /16 7⅛ 7⅞ DLR Ordering Information Series Faces Letter DLR 2 = Universal (Single/Double face R = Red G = Green AC = A/C EM = Backup 11⅝ 1⅝ 10

Snap-fit construction for easy installation Energy efficient LED light source Test switch and AC power indicator light UL Listed for damp locations (0 C 50 C).. SDC Die-Cast Aluminum LED Exit Light This exit sign is constructed in premium-grade aluminum housing for long lasting durability. The SDC is ideal for commercial and industrial applications where safety and low maintenance are important. Premium-grade aluminum housing (also available in black or white powder-coated finishes.) Field selectable knockout Chevron directional indicators. Unique design allows double face conversion in the field. Quick-snap face plate closure. 4.8V long life maintenance-free, rechargeable NiCd battery. 5 year limited warranty on all electronics and housing. pro-rated for five years. TP: Tamper-proof hardware helps prevent unauthorized access to the unit. SD: Self-diagnostic feature performs monthly, biannual, and annual tests to ensure reliable operation and to meet electrical and Life Safety Codes. 2C: Dual circuit option on the AC-only unit enables it to be connected to two different (one acting as a back-up to the other) supplies at the same time. Internal solid state transfer switch automatically connects the internal battery to LED board for minimum 90-minute emergency illumination. Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. Aluminum mounting canopy included for top or end mount. Universal K/O pattern on back plate for wall mount. Standard: Field selectable knockout Chevron directional indicators. Ultra-bright, energy efficient, long lasting Red or Green LED. Dual 120/277V voltage. Charge rate/power on LED indicator light and push-to-test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations (0 C 50 C). Certified to CEC under Title 20 Regulations. SDC Series Ordering Information 5½ 4 5 /16 Series Faces Letter SDC AC = AC B = Backup 1 = Single 2 = Double 3 = Universal Single/ Double Face G = Green R = Red A = Brushed Aluminum Face A = Brushed Aluminum 2C = Dual Circuit (AC ONLY) 2 SD = Self- Diagnostic 1 TP = Tamper Proof 9 8⅜ 1 Available only with B units. 2 Available only with AC units. 12⅝ 2 11

SEL Edgelit LED Exit Light The SEL offers a sleek, high-end modern look with long lamp life, energy efficiency and uniform illumination. This durable emergency light is used by hotels, apartment buildings, restaurants or really any place an emergency light is required by code. Energy efficient LED light source Easy to install and relatively maintenance free Test switch and AC power indicator light Premium grade, aluminum housing Internal solid state transfer switch automatically connects the internal battery to LEDs for minimum 90-minute emergency illumination. Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. 4.8V long-life, maintenancefree, rechargeable NiCd battery. Standard: Self adhesive Chevron appliques 5 year limited warranty on all electronics and housing. pro-rated for five years. Ultra bright, energy efficient, long life Red or Green LED. UV-stabilized ultraclear acrylic edgelit panel provides consistent, uniform illumination. Double face utilizes factory installed mirror or white mylar background panel. 5⅞ 4¼ 1¾ SEL Series Ordering Information Premium-grade, extruded aluminum housing (also available in black or white powder-coated finishes). Dual 120/277V voltage. Optional multitap 208/220/240 voltage available. Charge rate/power ON LED indicator light and push-to-test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations 32 F (0 C) 122 F (50 C). Certified to CEC under Title 20 Regulations. Aluminum mounting canopy included for top, end or back mount. SD: Self-diagnostic feature performs monthly, biannual, and annual tests to ensure reliable operation and meet electrical and life safety codes. 2C: Dual circuit option on the AC-only unit enables it to be connected to two different (one acting as a back-up to the other) supplies at the same time. CUSTOM: Signs available with special wording. SPV: UL Listed for special voltage option. 11⅞ 11 Series Faces Letter SEL AC = AC B = Backup 1 = Single 2 = Double R = Red G = Green Panel C = Clear 1 M = Mirror A = Brushed Aluminum SD = Self Diagnostics 3 2C = Dual Circuit 2 SPV = 208/220/240 Volt, 50/60Hz 4 CUSTOM = Custom Wording 12 13¾ 1 With single face only. 2 Not available with SD. 3 Available in B units only. 4 Available in AC units only.

Long life Red LED light source 24-hours to reach full charge Provides egress lighting for at least 90 minutes Push-to-test LED light for code compliant testing DLEL Edgelit LED Exit Sign The DLEL series is an architecturally pleasing lightweight, compact exit sign that includes a thermoplastic housing which is durable and cost effective. Injection-molded, engineering-grade 5VA, flame retardant, high impact resistant thermoplastic housing in white or black finish. 4.8V long-life, maintenance free, rechargeable NiCd battery. Dual 120/277V operation. Optional SV: multi-tap 208/220/240V available. Bi-color LED indicator light alerts occupant on battery condition (Green = OK, Red = Check ). Push-to-test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations, 32 F (0 C) 122 F (50 C). Certified to CEC under Title 20 Regulations. Ultra-bright, energy efficient, long life LEDs in Red or Green. UV-stabilized ultra-clear acrylic edgelit panel provides consistent, uniform illumination. Double face utilizes factory-installed mirror or white mylar background panel. Internal solid state transfer switch automatically connects the internal battery to LED board for minimum 90-minute emergency illumination. Fully automatic solid state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. EZ-snap mounting canopy included for top, end or back mount Standard: Self adhesive Chevron appliques 5 year limited warranty on all electronics and housing. pro-rated for five years. SD: Self Diagnostic Test feature continually diagnoses units performance and tests system to ensure reliable operation and to meet electrical and life safety codes. 2C: Dual Circuit option on the AC-only version enables it to be operated from two circuits (standard and back-up) at the same time. B: Emergency backup available. CUSTOM: Special wording available. DLEL Series Ordering Information Series Faces Letter DLEL 1 = Single 2 = Double R = Red G = Green Panel C = Clear 1 M = Mirror M = Mirror SD = Self Diagnostic 3 2C = Dual Circuit 4 (AC only) SV = 208/220/240V, 50/60Hz 2 CUSTOM = Custom Wording AC = AC B = Backup 10¾ 7 11 /16 ⅝ 5½ 1¾ 4 7 /16 11⅜ 11 15 /16 1 With single face only. 2 Not available with SD. 3 Available with B units. 4 Available in AC units only. 14 7 /16 12 11 /16 13

TEST AC ON TEST AC ON SREL Recessed Edgelit LED Exit Light The SREL recessed aluminum edgelit LED exit light offers a sleek, architectural look with long lamp life, energy efficiency and uniform illumination. Energy efficient LED light source Test switch and AC power indicator light Recessed ceiling mount applications only Trim assembly is easily detachable from below Premium-grade, extruded aluminum housing. Extruded aluminum trim assembly is easily detachable from below, providing accessibility for service or maintenance. Available in black or white powder-coated finishes. 4.8V long life, maintenance-free, rechargeable NiCd battery. Standard: Self adhesive Chevron appliques SD: Self-diagnostic feature performs monthly, biannual, and annual tests to ensure reliable operation and meet electrical and life safety codes. 2C: Dual circuit option on the AC-only unit enables it to be connected to two different (one acting as a back-up to the other) supplies at the same time. CUSTOM: Signs available with requested special wording. SV: UL Listed for special voltage option. WM: Allows for the unit to be wall recessed mounted. Internal solid-state transfer switch automatically connects the internal battery to LED board for minimum 90-minute emergency illumination. Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. 5 year limited warranty on all electronics and housing. prorated for five years. Compatible with drywall or drop ceiling mount installations. Bar hangers included. Wall mount capability optional. Dual 120/277V voltage. Optional multi-tap 208/220/240 voltage available. Charge rate/ power on LED indicator light and push-to-test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations 32 F (0 C) 122 F (50 C). Certified to CEC under Title 20 Regulations. Ultra bright, energy efficient, long life Red or Green LED. UV-stabilized ultraclear acrylic edgelit panel provides consistent, uniform illumination. Double face utilizes factory installed mirror or white mylar background panel. SREL Edgelit Series Ordering Information 10 9 /16 4⅛ 15¾ 14 9 /16 5 7 /16 ⅜ Wall mount dimensions 4⅜ 3¼ 11½ 11 Series Faces Letter SREL AC = AC B = Backup 1 = Single 2 = Double R = Red G = Green Panel C = Clear 1 M = Mirror A = Aluminum 2C = Dual Circuit 4 SD = Self Diagnostics 3 SV = 208/220/240 Volt, 50/60Hz 2 WM = Wall Mount 1 CUSTOM = Custom Wording 1 With single face only. 2 Not available with SD. 3 Available in B units only. 4 Available in AC units only. 14

Ultra bright LEDs Push-to-test switch Extremely low operating costs UL Listed for wet locations DLW Wet Location LED Exit Light Ultra bright, compact unit provides the affordability you ve been looking for in a high-end package. Long life LEDs and NiCad battery make this unit energy efficient and maintenance free! 5VA flame retardant, UV stabilized polycarbonate in white, black or gray finish. High impact resistant, UV stabilized polycarbonate clear lens. Corrosionresistant enclosure with engineering grade silicone gasket. Top and side K/O s provided for conduit feed applications. 4.8V long-life, maintenance free, rechargeable NiCd battery. Unique bi-color LED indicator light alerts occupant on battery condition (Green-normal, Red-check battery). 5 year limited warranty on all electronics and housing. Batteries prorated for five years. SD: Self-diagnostic feature performs monthly, biannual, and annual tests to ensure reliable operation and meet electrical and Life Safety Codes. 2C: Dual Circuit option on the AC-only version enables it to be connected to two different (one acting as a back-up to the other) supplies at the same time. TP: Tamper proof hardware helps prevent unauthorized access to the unit. CUSTOM: Signs available with requested special wording. Internal solid-state transfer switch automatically connects the internal battery to LED board for minimum 90-minute emergency illumination. Fully automatic solid state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Polycarbonate mounting canopy included for top or end mount. Universal K/O pattern on back plate for wall mount. Standard: EZ snap out Chevron directional indicators. Ultra-bright, energy efficient, long-lasting Red or Green LED. Dual 120/277V operation. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations, -4 F (-20 C) 122 F (50 C). DLW Series Ordering Information 5½ 4⅜ Series Faces Letter DLW 1 = Single R = Red 2 = Double G = Green (with white faceplate) (with black faceplate) G = Gray (with white faceplate) 2C = Dual Circuit 2 SD = Self Diagnostics 1 TP = Tamper Proof CW = Cold Weather 1 CUSTOM = Custom Wording AC = AC B = Backup 8½ 9¼ 1 Available in B units only. 2 Available in AC units only. 12½ 2½ 15

SCLD LED Dual Head Exit & Emergency Light An efficient and secure exit and emergency light combo that offers a traditional look and superior performance. Save money buying this 2-in-1 product. Combines UL listed two for damp emergency locations fixtures into one unit Optional 2 additional LED remote heads LED technology consumes less than 5 watts electricity Long lasting, low maintenance NiCad battery Push-to-test Fully adjustable button LED with heads LED provide charging a wide indicator range of motion Works for single and double face applications 9.6V Long-life, maintenancefree, rechargeable NiCd battery. EZ-snap mounting canopy included for top or end mount. Universal K/O pattern on back plate for wall mount. Standard: EZ snap out Chevron directional indicators. Internal solid-state transfer switch automatically connects the internal battery to LED board and LED lamp heads for minimum 90-minute emergency illumination. Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. RC: Remote capacity option available. Long lasting, efficient ultra-bright white LED lamp heads. 1 watt (8 LEDs x 0.125 watt) per head Highperformance chrome-plated metalized reflector and plastic lens for optimal light distribution. Adjustable LED lamp heads provides optimal center-to-center spacing. Optional high-lumen heads are available for increased center-tocenter spacing. Long-life, energy efficient Red or Green LED Exit sign illumination. Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-to-test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations, 32 F (0 C) 104 F (40 C). Certified to CEC under Title 20 Regulations. HL: 12-LED heads provide increased center-to-center spacing (1.5W per head). SD: Self-diagnostic feature performs monthly, biannual, and annual tests to ensure reliable operation and meet electrical and life safety codes. NH: No lamp head attach to the unit enabling it to be used as remote capable exit sign. 5 year warranty on all electronics and housing. pro-rated for five years. Injection-molded, engineering-grade, 5VA flame retardant, high-impact resistant, thermoplastic in white or black finish. SCLD Series Ordering Information 16 5⅛ 12 20 5 /16 4 5 /16 8⅝ 8 Series Faces Letter SCLD 2 = Universal single/double face R = Red G = Green RC = Remote Capable HL = High Lumen SD = Self Diagnostics NH = No Lamp Heads Accessories PS1 = Vandal Shield SW2 = Wire Guard NOTE: Refer to page 24 when ordering RC or SD options for corresponding models.

Combines two emergency fixtures into one unit LED technology consumes less than 5 watts electricity Push-to-test button with LED charging indicator Works for single and double face applications SCLI Exit & Emergency Combination Light The SCLI is the best fixture for applications that require an exit sign and a set of emergency lights. Combining the two safety lighting fixtures satisfies two fire code requirements. Two fully adjustable 5.4 watt, glare-free lamp heads. Smooth thermoplastic reflector and plastic lens for optimal light distribution. Ultra bright, energy efficient, long life Red or Green LED EXIT sign illumination. Standard: EZ snap out Chevron directional indicators. 5 year warranty on all electronics and housing. prorated for two years. Injection-molded, engineering grade, 5VA flame retardant, high-impact resistant, thermoplastic in white or black finish. SCLI Series Ordering Information Dual 120/277V voltage. Charge rate/power on LED indicator light and push-to-test switch for mandated code compliance testing. LVD (low voltage disconnect) prevents battery from deep discharge. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA and Local and State Codes. UL Listed for damp locations (20 C 40 C). Certified to CEC under Title 20 Regulations. Internal solid-state transfer switch automatically connects the internal battery to LED board and lamp heads for minimum 90-minute emergency illumination. Fully automatic solid-state, tworate charger initiates battery charging to recharge a discharged battery in 24 hours. REM: Remote capacity option available. EZ-snap mounting canopy included for top or end mount. Universal K/O pattern on back plate for wall mount. 6V maintenance-free, rechargeable sealed lead acid battery. SD: Self-diagnostic feature performs monthly, biannual, and annual tests to ensure reliable operation and meet electrical and Life Safety Codes. HTR: Optional internal heater for cold temperature applications. Series Faces Letter SCLI 2 = Universal Single/Double face R = Red G = Green HTR = Internal Heater 1 REM = Remote Capacity SD = Self Diagnostic 1 Not available with RC units. REM Series Ordering Information 11 5 ½ 4 13 /16 Series Number of Heads REM = Remote 5.4W Incandescent Head 1 = One 2 = Two WP = Weatherproof 5 = 5.4W lamps 7 = 7.2W lamps 9 = 9W lamps 20 ⅛ 27 ¼ 13 2 ¾ 10 3 /16 17

SCLB Lightbar Remote Capable Exit & Emergency Light This compact unit, with its pipe-style emergency light, offers even light distribution without the hassle of aiming individual heads! Our low-profile combo unit is perfect for mounting above doors or otherwise restricted spaces. Energy-efficient white LED low-profile unit Ultra bright LED emergency lighting 1.5W, wattage is 4.5W when in emergency mode UL Listed for damp locations SD: Self-diagnostic feature performs monthly, biannual,and annual tests to ensure reliable operation and meet electrical and life safety codes. 4.8V Long-life, maintenance-free, rechargeable NiCd battery. Standard: EZ snap out Chevron directional indicators. Injection-molded, engineering-grade, 5VA flame retardant, highimpact, thermoplastic in white or black. Dual 120V/277V. Charge rate/power ON LED indicator light and push-to-test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations, 0 C (32 F) 50 C (122 F). Certified to CEC under Title 20 Regulations. Internal solid-state transfer switch automatically connects the internal battery (standard) to LED Board/ light bar for minimum 90-minute emergency illumination. Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. RC: Remote capable standard. EZ-snap mounting canopy included - provides top or end mount. Universal K/O pattern on back plate for wall mount. Five year warranty on all electronics and housing. prorated for five years. Ultra-bright, energy efficient white LED emergency lighting. 4.5W (36 LEDs x 0.125 watts) per light pipe. Adjustable high performance, smooth, chromeplated, metallized reflector and acrylic, UV-stabilized Light Pipe lens for optimal light distribution. Long life, energy efficient Red or Green LED EXIT sign illumination. 5½ 4⅜ SCLB Series Ordering Information 8¼ 9⅛ Series Faces Letter SCLB 2 = Universal single/double face R = Red G = Green SD= Self Diagnostics RC= Remote Capable (standard) B = Backup 12½ 1⅞ NOTE: Refer to page 24 when ordering RC or SD options for corresponding models. 18

Energy efficient LED light source canopy included for top or end mount Cold weather unit and will operate down to -20 C UL Listed for wet locations DLWC Wet Location LED Exit & Emergency Combination Light This LED combo features a construction that is ideal for wet locations, while also being resistant to corrosive atmospheres, non-hazardous dust environments, frequent hose-downs, water spray or splashing water. Dual 120/277V voltage. Unique bi-color LED indicator light alerts occupant on battery condition (Green-normal, Red-check battery). Meets UL924, NFPA 101 Life Safety Code, OSHA, NEC and Local and State Codes. UL listed for Wet location 32 F (0 C) 122 F (50 C). Certified to CEC under Title 20 Regulations. Die-cast aluminum mounting canopy included for top or end mount. Universal K/O pattern on back plate for wall mount. Standard: EZ snap out Chevron directional indicators. 5 year limited warranty on all electronics and housing. pro-rated for five years. Long lasting, efficient, ultra bright white LED lamp heads. 3.6W (3 LEDs x 1.2 watt) per head. Adjustable LED lamp heads provide optimal centerto-center spacing. Long-life, energy efficient Red or Green LED EXIT sign illumination. Internal solid-state transfer switch automatically connects the internal battery to LED board and lamp heads for minimum 90-minute emergency illumination. Fully automatic solidstate, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. RC: remote capacity available as an option. SD: Self-diagnostic feature performs monthly, biannual, and annual tests to ensure reliable operation and meet electrical and life safety codes. TP: Tamper-proof hardware helps prevent unauthorized access to the unit. CW: Optional internal heater and battery blanket for extreme cold temperature applications -4 F (-20 C) 122 F (50 C). CUSTOM: Signs available with requested special wording. 6V long life, maintenance free, rechargeable NiCd battery. 5VA flame retardant, UV stabilized polycarbonate in white, black or gray finish. High-impact resistant, UV stabilized polycarbonate clear lens. Corrosion resistant enclosure with engineering grade silicone gasket. K/O s provided for conduit feed applications. DLWC Series Ordering Information 5 15 /16 5 15 /16 Series Faces Letter DLWC 1 = Single R = Red 2 = Double G = Green G = Gray (with white faceplate) CW = Cold weather RC = Remote capacity SD = Self diagnostic TP = Tamper proof CUSTOM = Custom Wording 13 11 /16 12¾ NOTE: Refer to page 24 when ordering RC or SD options for corresponding models. 12⅜ 19 4 1 /16

SEM Emergency Light This durable emergency light is used by hotels, apartment buildings, restaurants or really any place an emergency light is required by code. It is easy to install and relatively maintenance free. Two fully adjustable lighting heads Flexible and economical 5 year limited warranty Features a Red Quick test button Injection-molded, engineering-grade, 5VA flame retardant, high-impact resistant, thermoplastic in white or black finish. Surface mount via quick-connect back plate; fits most standard size junction boxes and snaps into place making internal electrical connections. Knockout for conduit applications. Suitable for wall mount. Two fully adjustable 5.4W glare-free lamp heads. Smooth thermoplastic reflector and plastic lens for optimal light distribution. 6V maintenancefree, rechargeable sealed lead acid battery. Internal solid-state transfer switch automatically connects the internal battery to lamp heads for minimum 90-minute emergency illumination. Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-to-test switch for mandated code compliance testing. LVD (low voltage disconnect) prevents battery from deep discharge. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations (20 C 50 C). Five year warranty on all electronics and housing. Batteries pro-rated for two years. SD: Self-diagnostic feature performs monthly, biannual, and annual tests to ensure reliable operation and meet electrical and life safety codes. HTR: Optional internal heater for cold temperature applications. SEM Series Ordering Information Series SEM HTR = Internal Heater REM = Remote Capable SD = Self Diagnostics REM Series Ordering Information Series Number of Heads REM = Remote 5.4W Incandescent Head 1 = One 2 = Two WP = Weatherproof 5 = 5.4W lamps 7 = 7.2W lamps 9 = 9W lamps 20

Energy efficient LED light source Features a Red Quick test button 5 year limited warranty Meets all required Life Safety Codes SFOEMLED Fixed Optics LED Emergency Light SFOEMLED Fixed Optics LED Emergency Light is ideal for applications where economical emergency lighting is required. Injection-molded, engineering grade, 5VA flame retardant, high-impact resistant, thermoplastic in white or black finish. Surface mount via easy connect back plate, which fits most standard junction boxes and snaps into place making internal electrical connections. Suitable for wall or ceiling mount. Long life, efficient, ultra bright LED lamp heads. 12 LEDs per head. High performance, chrome-plated metalized reflector and plastic lens for optimal light distribution. Two fixed LED lamp heads provide optimal center-to-center spacing. Internal solid-state transfer switch automatically connects the internal battery to LED lamp heads for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Dual 120/277 voltage standard. Charge rate/power ON LED indicator light and push-to-test switch for mandated code compliance testing. Meets UL924, culus, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. CSA Listed for damp locations (0 C 40 C). 3.6V long life, maintenance-free, rechargeable NiCd battery. Five year warranty on all electronics and housing. pro-rated for five years. 11 13 /16 SFOEM LED Series Ordering Information 5 1 /8 Series SFOEMLED C4 = 4 Cord & Plug C7 = 7 Cord & Plug 2 3 /8 21

SFOEM Fixed Optics Incandescent Emergency Light SFOEM Fixed Optics Emergency Light is ideal for applications where economical emergency illumination along the path of egress is desired. Economical emergency illumination Features a Red Quick test button Easy connect back plate mounting ETL listed for damp locations Injection-molded, engineering-grade, 5VA flame retardant, high-impact resistant, thermoplastic in white or black finish. Surface mount via easy connect back plate, which fits most standard junction boxes and snaps into place making internal electrical connections. Suitable for wall mount. Two fixed optics 5.4W glare-free lamp heads. Smooth thermoplastic reflector and plastic lens for optimal light distribution. Internal solid-state transfer switch automatically connects the internal battery to lamp heads for minimum 90-minute emergency illumination. Fully automatic solid-state, tworate charger initiates battery charging to recharge a discharged battery in 24 hours. Low voltage disconnect prevents battery From deep discharge. Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-to-test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. ETL listed for damp locations (20 C 50 C). 6V maintenance-free, rechargeable sealed lead acid battery. 5 year limited warranty on all electronics and housing. prorated for two years. 11 13 /16 5 1 /8 SFOEM Series Ordering Information 2 3 /8 Series SFOEM C4 = 4 Cord & Plug C7 = 7 Cord & Plug 22

Offers a push-to-test switch, low-voltage disconnect Remote capable model available E-Z quick connect for fast installation UL listed for damp locations DLM LED Emergency Light This sleek, economical emergency light offers a contemporary look for lighting and design. Lowmaintenance and easy operation makes the DLM an unbeatable model. Internal solid-state transfer switch automatically connects the internal battery to LED lamp heads for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Injection-molded, engineering-grade, 5VA flame retardant, high-impact resistant, thermoplastic in white or black finish. Surface mount via easy connect back plate, which fits most standard junction boxes and snaps into place making internal electrical connections. Knockout for conduit applications. Suitable for wall or ceiling mount. Five year warranty on all electronics and housing. Batteries pro-rated for five years. SD: Self-diagnostic feature performs monthly, biannual, and annual tests to ensure reliable operation and meet electrical and Life Safety Codes. HL: 12-LEDs per head provide increased center-tocenter spacing. SV: UL Listed for special voltage option. Dual 120V/277V voltage. Optional multi-tap 208/220/240 voltage available. Charge rate/ power ON LED indicator light and push to test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for damp locations (0 C 50 C). 3.6V long life, maintenance-free, rechargeable NiCd battery. Long lasting, efficient ultra-bright white LED lamp heads. 1W (8 LEDs x 0.125 watt) per head. Highperformance chromeplated metallized reflector and plastic lens for optimal light distribution. Adjustable LED lamp heads provide optimal center-to-center spacing. High-lumen option available for increased center-to-center spacing. DLM Series Ordering Information 2½ 5⅜ 1¾ Series DLM HL = High Lumen SD = Self Diagnostics SV = 208/220/240 multi-tap voltage in 50/60Hz 1 RC = Remote Capable 4 9 /16 3 11 /16 1 Not available with SD units. Note: Refer to page 24 when ordering RC or SD options for corresponding models. 12 101 /16 23

DLH LED Remote Heads DLH remote heads are designed to operate with remote capable LED combos and Emergency lights. The DLH series are available in indoor or outdoor, single and dual head versions. V-0 flame retardant, high-impact, thermoplastic housing Long-lasting, efficient ultra-bright white LEDs Available in indoor and outdoor usage UL Listed Construction Indoor application remote heads are injection-molded, engineeringgrade, 5VA flame retardant, highimpact resistant, thermoplastic in white (standard) or black finish. Outdoor application remote heads are die-cast aluminum, sealed and gasketed in grey finish only. Universal mounting base mounts to single-gang switch box. Distance of maximum run is determined by system voltage, wire gauge and total maximum wattage on the run. Suitable for wall or ceiling mount. Outdoor Injection-molded, V-O flame retardant, highimpact, thermoplastic housing. Indoor Long lasting, efficient ultra-bright white LEDs. Highperformance chrome plated metalized reflector and polycarbonate lens (indoor applications) or glass lens (outdoor applications) for optimal light distribution. Adjustable LED lamp heads increase center-to-center spacing with 8 LEDs in each head. DLH Series Ordering Information Series Voltage Heads DLH C = 9.6V R = 3.6V MV = Multi Volt 1 2 3 year limited warranty. Powered from low voltage power source with low voltage wiring (not provided). UL Listed. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. (standard) G = Grey (Available with WP Option only) WP = Weather Proof SD = Self Diagnostics 10⅜ *Indoor remote head available in thermoplastic white or black housing only *Outdoor remote head available in die-cast aluminum housing only *MV = Multi Volt can be used for all LED Models *SD option must be used when host fixture has SD selected 4⅞ Fixture Compatibility Chart 4½ 5 5⅞ 8½ 4¼ 6⅝ 6¾ Model SCLD SCLB DLWC DLM DLP DLHR 3.6V X X DLHC 9.6V X X X MV X X X X X 24

Push-to-test switch for compliance testing 1.5W, wattage is 4.5W when in emergency mode Long lasting ultra bright LED lamp heads UL Listed for wet locations. DLP Wet Location LED Emergency Light The DLP is designed for durability and provides emergency illumination through most weather conditions. Its unique design combines an energy-efficient LED exit sign with an LED emergency light into one low-profile unit. Dual 120/277V voltage. Charge rate/power on LED indicator light and push-to-test switch for mandated code compliance testing. LVD (low voltage disconnect) prevents battery from deep discharge. Remote capacity of 3.7W available as an option. 32 F (0 C) 122 F (50 C). Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for wet locations -4 F (-20 C) 122 F (50 C). External mounting brackets for simplified wall mounting provided. 9.6V long life, maintenancefree, rechargeable NiCd battery. Corrosion-resistant 5VA flame retardant UV-stabilized polycarbonate in gray or black finish. Sealed and gasketed housing with hinged cover. Sealed test switch. Internal solid state transfer switch automatically connects the internal battery to LEDs for minimum 90-minute emergency illumination. Fully automatic solid-state, tworate charger initiates battery charging to recharge a discharged battery in 24 hours. Sealed and gasketed weather proof lamp heads with high performance chrome-plated metalized reflector and tempered glass lenses for optimal light distribution. Long lasting efficient ultra bright white LED lamp heads. 1.875W (15 LEDs x 0.125) per head. 5 year limited warranty on all electronics and housing. pro-rated for five years. DLP Series Ordering Information 5⅞ 12 3 /16 Series Accessories DLP HTR = Internal Heater PS1 = Vandal Shield G = Gray RC = Remote Capable SW1 = Wire Guard 6½ Note: Refer to page 24 when ordering RC or SD options for corresponding models. 9 5 /16 8 25 3½

SDBEL Outdoor LED AC/ Emergency Light This decorative, low-profile emergency light uses an ultra-bright white, 6-watt LED that provides a reliable source of illumination in the event of a power failure. Great for hotels, apartment buildings, restaurants or any place an emergency light is required by code. UL listed for wet locations (0 C to 50 C) Push-to-test switch for compliance testing Decorative, low profile, architectural design Self-diagnostic test feature Standard Dual 120-277VAC voltage. Charge rate/power ON LED indicator light and push-to-test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA,Local and State Codes. UL Listed for wet locations. (0 C 50 C). Internal solid-state transfer switch automatically connects the internal battery to LED board for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Self-diagnostic test feature continually diagnoses units performance and tests system to ensure reliable operation and to meet electrical and Life Safety Codes. Field-selectable wiring allows for AC operation of the unit to be controlled using a wallswitch or a photocell or any other switching mechanism. Five year warranty on all electronics and housing. pro-rated for five years. CW: Optional internal heater for extreme cold temperature applications (-20 C 50 C). PC: Unit features optional photocell technology that automatically responds to low exterior lighting levels in AC mode. 4.8V long life, maintenance-free, rechargeable NiCd battery. Surface mount via easy connect back plate that fits most standard size junction boxes. Universal K/O pattern on back plate for wall mount. Long life, efficient, ultra-bright white LED. 5 watt LED per unit. Mirror-bright reflector and prismatic polycarbonate refractor. Decorative, low profile, architectural design. Die-cast aluminum housing. Durable powder-coated finishes in white, black, nickel and dark bronze. Sealed and gasketed. SDBEL Series Ordering Information 10½ Series SDBEL BR = Bronze CW = Cold Weather PC = Photocell 26 6 9 /16 3 5 /8

Sturdy 20-gauge steel construction 120-minute emergency illumination Chicago approved Push button allows for easy testing pro-rated for two years SHDLEDCA LED Heavy Duty Emergency Light Chicago Approved The SHDLEDCA is a powerhouse with the highest wattage capacity of our emergency offering. It is designed for indoor use in all types of commercial facilities. Dual 120V/277V. Charge rate/power ON LED indicator light and push to test switch for mandated code compliance testing. LVD (low voltage disconnect) prevents battery from deep discharge. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations (20-50 C/68 F-122 F standard). Five year warranty on all electronics and housing. pro-rated for two years. UL Listed for damp locations (20 C 50 C). 6V sealed lead calcium maintenance free rechargeable battery. Durable 20-gauge steel housing. Neutral white finish. Internal solid-state transfer switch automatically connects the internal battery to lamp heads for minimum 120-minute emergency illumination. Fully automatic solid-state, tworate charger initiates battery charging to recharge a discharged battery in 24 hours. Two, 6V 5.3W adjustable white LED lamp heads. Side and top conduit knockouts. SHDLEDCA Series Ordering Information Series Wattage SHDLEDCA 6V = 6V 10 = 10W capacity 20 = 20W capacity (standard) 11⅜ 5 12⅜ 2½ 27

SELNY Aluminum LED Edgelit Exit NYC Approved The SELNY exit sign is popular for its high-end appeal and energy efficient profile. Edgelit exit signs are seen throughout New York City s finest commercial office, retail, and apartment buildings. Uses less than five watts electricity at all times Push-to-test button with LED charging indicator Works for single and double face applications Universal mounting canopy Internal solid-state transfer switch automatically connects the internal battery to LED board for minimum 90-minute emergency illumination. Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. Aluminum mounting canopy included for top, end or back mount. 4.8V long-life, maintenancefree, rechargeable NiCd battery. Standard: Self adhesive Chevron appliques Ultra-bright, energy efficient, long life Red or Green LED. UV-stabilized ultra-clear acrylic edgelit panel provides consistent, uniform illumination. Double face utilizes factory installed mirror or white mylar background panel. 5 year limited warranty on all electronics and housing. pro-rated for five years. SD: Self-diagnostic feature performs monthly, biannual, and annual tests to ensure reliable operation and meet electrical and life safety codes. SPV: UL Listed for special voltage option. Dual 120/277V voltage. Charge rate/power on LED indicator light and push-to-test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations 32 F (0 C) 122 F (50 C). Certified to CEC under Title 20 Regulations. Premium-grade, extruded aluminum housing (also available in black or white powder-coated finishes). 1¼ SELNY Series Ordering Information 13 1 /8 Series Faces Letter SELNY AC = AC Only B = Backup 1 = Single 2 = Double Panel R = Red C = Clear 1 M = Mirror A = Aluminum SD = Self-Diagnostics 3 SPV = 208/220/240 Volt 2 50/60Hz 15 3 /16 1 With single face only. 2 Not available with SD. 3 Available in B units only. 4 Available in AC unit only. 28

Compliant throughout the five boroughs of NYC Efficient LEDs consume less than 5 watts Push-to-test button with LED charging indicator 20-gauge steel housing is durable yet attractive SXTEUNY Steel LED Exit Sign NYC Approved The SXTEUNY Series is a steel exit sign that is approved for use in New York City. Bright and efficient LEDs provide reliable exit illumination, and a small battery backup system provides reliable emergency power. Ultra-bright, energy efficient, long life Red LED. NY approved 8 exit letters. 5 year limited warranty on all electronics and housing. pro-rated for five years. Standard: Field selectable knockout Chevron directional indicators. Dual 120/277V voltage. Charge rate/power on LED indicator light and push to test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. Certified to CEC under Title 20 Regulations. Internal solid state transfer switch automatically connects the internal battery to LED board for minimum 90-minute emergency illumination. Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. Aluminum mounting canopy included for top or end mount. Universal K/O pattern on back plate for wall mount. K/O provided for conduit feed applications. 3.6V long-life, maintenancefree, rechargeable NiCd battery. Durable, powder-coated 20-gauge steel construction in white or black finish. SXTEUNY Series Ordering Information 2¼ Series Faces Letter SXTEUNY AC = AC B = Backup 3 = Universal Single/ Double Face R = Red 10 7 / 16 14⅝ 29

SDCNY Diecast Aluminum Exit Sign NYC Approved The SDCNY is a premium-grade, aluminum housing sign that is architecturally pleasing. It offers a ultra-bright, energy efficient, long-life Red LED, and a unique design allows double face conversion in the field. Push-to-test switch for mandated code compliance testing Universal K/O pattern on back plate for wall mount UL listed for damp locations (0 C 50 C). Five year warranty SD: Self-diagnostic feature performs monthly, biannual, and annual tests to ensure reliable operation and meet electrical and Life Safety Codes. 2C: Dual circuit option on the AC-only unit enables it to be connected to two different (one acting as a back-up to the other) supplies at the same time. Aluminum mounting canopy included for top or end mount. Universal K/O pattern on back plate for wall mount. Ultra-bright, energy efficient, long-life Red LED. NY approved 8 Exit letters. Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-to-test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations (0 C 50 C). Certified to CEC under Title 20 Regulations. Internal solid-state transfer switch automatically connects the internal battery to LED board for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. 5 year warranty on all electronics and housing. pro-rated for five years. 4.8V long-life, maintenance-free, rechargeable NiCd battery. Standard: Field selectable knockout Chevron directional indicators. Premium-grade, aluminum housing (also available in black or white powder-coated finishes). 6 11 /16 4 3 /8 SDCNY Series Ordering Information 11¼ 15½ 10 3 /8 2 1 /16 Series Faces Letter SDCNY AC = AC B = Backup 1 Available in B units only. 1 = Single 2 = Double 3 = Universal Single/ Double Face R = Red A = Aluminum Face A = Aluminum SD = Self- Diagnostic 1 30

Unique illumination design Energy efficient LED 90+ minute emergency operation Single or double face configuration SRELNY Recessed Aluminum LED Edgelit Exit NYC Approved The SRELNY LED offers a compact and recessed decorative design. It utilizes a unique illumination design in an architectural aluminum housing. Ideal for commercial use where economy, appearance and the ultimate ease of installation and maintenance are desired. Internal solid state transfer switch automatically connects the internal battery to LED board for minimum 90-minute emergency illumination. Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. 4.8V long life, maintenance-free, rechargeable NiCd battery. 5 year warranty on all electronics and housing. pro-rated for five years. SD: Self-diagnostic feature performs monthly, biannual, and annual tests to ensure reliable operation and meet electrical and Life Safety Codes. SPV: UL Listed for special voltage option. WM: Allows for the unit to be wall recessed mounted. Offers an ultra-bright, energy-efficient, long-life Red LED. UV-stabilized ultra-clear acrylic edgelit panel provides consistent, uniform illumination. Double face utilizes factory installed mirror or white mylar background panel. NY compliant 8 Exit letters. Dual 120/277V voltage. Charge rate/power ON LED indicator light and push-to-test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations. (0 C 50 C). Certified to CEC under Title 20 Regulations. Compatible with drywall or drop ceiling mount installations. Bar hangers included. Wall mount capability optional. Standard: Self adhesive Chevron appliques Premium-grade, extruded aluminum housing. Extruded aluminum trim assembly is easily detachable from below, providing accessibility for service or maintenance. Available in black or white powder-coated finishes. SRELNY Series Ordering Information Series Faces Letter SRELNY AC = AC B = Backup 1 = Single 2 = Double Panel R = Red C = Clear 1 M = Mirror 1 With single face only. 2 Not available with SD. 3 Available in B units only. A = Aluminum SD = Self- Diagnostics 3 SPV = 208/220/240 Volt, 50/60Hz 2 WM = Wall Mount 1 31

SCLDNY Steel Combo Emergency Exit NYC Approved The SCLDNY units are designed for both initial and retrofit installations and offer high-power efficiency and uniform illumination, which is ideal for stores, offices, hospitals and school corridors. Dual-voltage input 120V/277V 20-gauge die-formed cold-rolled steel housing Meets NYC requirements UL listed for damp locations Two factory installed thermoplastic enclosed lamp heads (Third lamp head optional). 9W lamp heads provide increased center-to-center spacing. Dual 120/277 voltage. Charge rate/power ON LED indicator light and push to test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations, 10 C (50 F) 40 C (104 F). Internal solid-state transfer switch automatically connects the internal battery to LED board and LED lamp heads for minimum 90-minute emergency illumination. Fully automatic solid-state, tworate charger initiates battery charging to recharge a discharged battery in 24 hours. Long lasting, efficient ultra-bright white LED lamp heads. 9 watts per head. High-performance chrome-plated metalized reflector and plastic lens for optimal light distribution. Adjustable LED lamp heads provides optimal center-to-center spacing. Optional high-lumen heads are available for increased center-to-center spacing. NY approved 8 exit letters. 6V Long-life, maintenancefree, rechargeable NiCd battery. 20-gauge die-formed, coldrolled steel housing. Injectionmolded, engineering-grade, 5VA flame retardant, highimpact resistant, thermoplastic heads. Standard: EZ snap out Chevron directional indicators. Universal K/O pattern on back plate for wall mount. Five year warranty on all electronics and housing. pro-rated for five years. SCLDNY Series Ordering Information Series Faces Letter SCLDNY AC = AC B = Backup 1 = Single Face R = Red 2 = 2 Lamp Heads 3 = 3 lamp Heads 32

Meets NYC requirements 20-gauge steel construction 90-minute emergency illumination 5 year warranty SHDLEDNY Heavy Duty Steel Emergency Light NYC Approved The SHDLEDNY is the powerhouse efficiency and uniform illumination and 20-gauge steel housing. Units are designed for both initial and retrofit installations, which is ideal for stores in offices, hospitals and school corridors. Two/Three, 9W adjustable white LED lamp heads. Factory installed thermoplastic-enclosed lamp heads. Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-to-test switch for mandated code compliance testing. LVD (low voltage disconnect) prevents battery from deep discharge. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. Meets New York requirements. UL Listed for damp locations (10 C 40 C). Internal solid-state transfer switch automatically connects the internal battery to the LED lamp heads for minimum 90-minute emergency illumination. Fully automatic solidstate, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Five year warranty on all electronics and housing. Knockouts on the back for wall mount. Side and top knockouts for conduit feed applications. 6V sealed NiCd, maintenance-free, rechargeable battery. Durable 20-gauge steel construction, white color. SHDLEDNY Series Ordering Information Series Letter SHDLEDNY AC = AC B = Backup 2 = 2 Lamp Heads 3 = 3 Lamp Heads 33

SXTEUCA Chicago Approved Steel Exit Sign The SXTEUCA is ideal for applications where a steel housing and glass exit sign panels are required. White LED technology provides uniform illumination and an expected life of up to 10 years. City of Chicago approved (120 minutes) Ultra-bright and energy-efficient Letters 6 High with 100 ft. Viewing Distance Exit illuminated with high-output, long-life LEDs 20-gauge steel housing. Neutral white or black finish. canopy included for top or end mount. Universal K/O pattern on back plate for wall mount. Ultra-bright, energy efficient, long-lasting white LEDs provide uniform illumination. Single or double face configurations. 4.8V Long-life, maintenance-free, rechargeable NiCd battery (B models only). Internal solid-state transfer switch automatically connects the internal battery to LED board for minimum 120-minute emergency illumination. Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. Dual 120V/277V. Charge rate/power ON LED indicator light and push to test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL listed for damp locations (0-50 C/32 F- 122 F). Meets city of Chicago requirements. Certified to CEC under Title 20 Regulations. SXTEUCA Series Ordering Information Five year warranty on all electronics and housing. pro-rated for five years. Series Faces Letter SXTEUCA AC = AC B = Backup 1 = Single 2 = Double R = Red Signage/Directional Arrows NA = Exit No Arrow SWNA = Stairs No Arrow DA = Exit Double Arrow SWDA = Stairs Double Arrow RA 1 = Exit Right Arrow SWRA 1 = Stairs Right Arrow LA 1 = Exit Left Arrow SWLA 1 = Stairs Left Arrow LARA 2 = Exit Left/Right Arrow SWLARA 2 = Stairs Left/Right Arrow 34 1 Available in single face configuration only. 2 Available in double face configuration only. *See page 39 for Signage/Directional Arrow Ordering Diagrams

Meets Chicago requirements (120 minutes) 5 year warranty on all electronics and housing pro-rated for five years UL Listed for damp locations (0 C 50 C) SELCA LED Exit Sign Chicago Approved The SELCA is a long-lasting, energy-efficient LED exit sign. It features multiple arrow configuration options for exit or stairs. Operates for 120 minutes of emergency illumination. Dual 120V/277V. Charge rate/power ON LED indicator light and push to test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. Meets city of Chicago requirements. UL listed for damp locations (0-50 C/32 F-122 F). Certified to CEC under Title 20 Regulations. Die-cast aluminum mounting canopy provided for universal top, end or back mount. Premium-grade, extruded aluminum housing (also available in white powdercoated finish). Ultra-bright, energy efficient, long-lasting white LEDs provide uniform illumination. UV stabilized, silk screened acrylic panels provide consistent, uniform illumination. Single or double face configurations. SELCA Series Ordering Information Five year warranty on all electronics and housing. pro-rated for five years. Internal solid-state transfer switch automatically connects the internal battery to LED board for minimum 120-minute emergency illumination. Fully automatic solidstate, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. 13 6 4.8V Long-life, maintenance-free, rechargeable NiCd battery (B models only). 4½ Series Faces Letter SELCA AC = AC B = NiCd 1 = Single 2 = Double RW = Red on White A = Aluminum Signage/Directional Arrows NA = Exit No Arrow SWNA = Stairs No Arrow DA = Exit Double Arrow SWDA = Stairs Double Arrow RA 1 = Exit Right Arrow SWRA 1 = Stairs Right Arrow LA 1 = Exit Left Arrow SWLA 1 = Stairs Left Arrow LARA 2 = Exit Left/Right Arrow SWLARA 2 = Stairs Left/Right Arrow 15¼ 6 4½ 13⅜ 14⅛ 1 Available in single face configuration only. 2 Available in double face configuration only. *See page 39 for Signage/Directional Arrow Ordering Diagrams 35

SRELCA LED Edgelit Exit Sign - Recessed Mount Chicago Approved The SRELCA is made of a premium grade, extruded aluminum housing. Ultra-bright, energy efficient, longlasting white LEDs provide uniform illumination. Meets Chicago requirements (120 minutes) Trim assembly is easily detachable for maintenance Five year warranty on electronics and housing UL Listed for damp locations (20 C 50 C) Internal solid-state transfer switch automatically connects the internal battery to LED board for minimum 120-minute emergency illumination. Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours. Compatible with drywall or drop-thru ceiling mount installation. Wall mount capability optional. Premium-grade, extruded aluminum housing. Extruded Aluminum Trim Assembly is easily detachable, providing accessibility for service or maintenance. Available in Optional White Finish. Five year warranty on all electronics and housing. pro-rated for five years. 15¾ 14⅝ 4⅛ 3¼ WM: Wall mount. Dual 120V/277V. Charge rate/power ON LED indicator light and push-to-test switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. Meets city of Chicago requirements. UL listed for damp locations (0-50 C/32 F-122 F standard). Certified to CEC under Title 20 Regulations. SRELCA Series Ordering Information 4.8V Long-life, maintenance-free, rechargeable NiCd battery (B models only). Ultra-bright, energy efficient, long-lasting white LEDs provide uniform illumination. UV stabilized, silk screened acrylic panels provide consistent, uniform illumination. Single or double face configurations. 18 16⅞ 4⅛ 3¼ 12½ 13¼ Series Faces Letter SRELCA AC = AC B = NiCd 1 = Single 2 = Double RW = Red on White A = Aluminum WM = Wall Mount Signage/Directional Arrows NA = Exit No Arrow SWNA = Stairs No Arrow DA = Exit Double Arrow SWDA = Stairs Double Arrow RA 1 = Exit Right Arrow SWRA 1 = Stairs Right Arrow LA 1 = Exit Left Arrow SWLA 1 = Stairs Left Arrow LARA 2 = Exit Left/Right Arrow SWLARA 2 = Stairs Left/Right Arrow 1 Available in single face configuration only 2 Available in double face configuration only *See page 39 for Signage/Directional Arrow Ordering Diagrams 36

SCLDCA Steel Exit Sign Chicago Approved Includes (2) 5.3W adjustable White LED lamp-heads 20 gauge steel housing with glass panels Chicago compliant 120 minute run-time Temperature Range: Standard: 20 C to 50 C The SCLDCA series is constructed from durable 20-gauge steel. This unique design allows double face conversion on field. It offers LEDs for improved energy efficiency. canopy included for top or end mount. Universal K/O pattern on back plate for wall mount. 6V sealed lead acid, maintenance-free, rechargeable battery. LVD: (low voltage disconnect) prevents battery from deep discharge. Five year warranty on all electronics and housing. pro-rated for two years. Dual 120/277 voltage standard. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for damp locations (20 C 50 C). Internal solid-state transfer switch automatically connects the internal battery to LED board and LED lamp heads for minimum 120 minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. RC: Remote capacity option available. SCLDCA Series Ordering Information Series Faces Letter SCLDCA 1 = Single 2 = Double R = Red RC = Remote Capacity Available in single face configuration only. Available in double face configuration only. *See page 39 for Signage/Directional Arrow Ordering Diagrams Signage/Directional Arrows 611/16 5 5/8 4½ 2½ NA = Exit No Arrow SWNA = Stairs No Arrow DA = Exit Double Arrow SWDA = Stairs Double Arrow RA1 = Exit Right Arrow SWRA1 = Stairs Right Arrow LA1 = Exit Left Arrow SWLA1 = Stairs Left Arrow LARA2 = Exit Left/Right Arrow SWLARA2 = Stairs Left/Right Arrow 163/16 15¼ 10¼ 1 2 12 3/8 2¼ 37 & Durable 20-gauge steel construction. White or black finish. E M E R G E N C Y E X I T Long lasting, energy efficient White LED exit sign illumination. Single or double face configuration. Two 6V 5.3W adjustable white LED lamp heads.

Exit and Emergency Accessories Protective barriers heavy duty wire-guards offer protection for emergency and exit products in vandal or high abuse applications. Replacement Batteries EB100 Series EB Series Ordering Information Series EB PS1 Polycarbonate shield for SLED Exit signs and SEM Emergency lights. 7.5 x 21 x 13 100 = Operates one lamp, 450 maximum lumen output 60 = Operates one or two lamps, 700 maximum lumen output 50 = Operates one or two lamps, 1400 maximum lumen output Replacement power sources for our most popular emergency and exit products. SW1/SW2 Durable stainless steel construction. Specify suffix (1) for SEM, SDC, SFOEM and SLED Exit & Emergency lights. 13.5 x 15 x 6 Specify suffix (2) for SCLI Exit Signs 13.5 x 30 x 6 Heavy gauge steel case, white powder coat finish. EB100 operates one lamp at 500 initial lumens. EB60 and EB50 can operate one or two lamps at 450, 700, or 1400 initial lumens. Compatible with most 1, 2, 3, and 4-lamp electronic, standard, energy saving and dimming AC ballasts. Sealed nickel-cadmium, maintenance-free, rechargeable with life expectancy of 7 to 10 years. Dual 120/277V voltage. Charge rate/power on LED indicator light and push-to-test switch for code compliance. UL listed, damp location, for retrofit/field installation to UL924 and C-UL, NFPA 101 Life Safety Code, and NEC requirements. Inside, on top of, or remote mount from existing fluorescent fixtures. Remote mounting distance of emergency ballasts should not exceed half the AC ballast manufacturer s recommended remote mounting distance from the lamps for standard AC ballasts, or 50 feet, whichever is less. Five year warranty on all electronics and case. 38