PROGRAMMABLE 7-DAY THERMOSTAT

Similar documents
PROGRAMMABLE 7-DAY RF THERMOSTAT

BeSMART Thermostat. EN Thermostat Manual

Vokèra OpenTherm 711 with external sensor connected

Vokèra OpenTherm 711 without external sensor connected

Easy-Stat. Wireless Programmable Room Thermostat Pt No

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

CS027 User Instructions

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

Installer and User Manual. BeSMART. Thermostat WiFi Box and boiler RF receiver. Installer and User Manual ESC MODE SET PROG RESET

C-Stat 17-ZW User Instructions

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

RF Programmable Room Thermostat Installation Instructions

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

User Manual for model

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS

Digital Room Thermostat

Installation & User s Instructions

Programmable Room Thermostat Installation Instructions

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

INSTALLATION INSTRUCTIONS

User Manual THR842DUK Wireless Digital Thermostat

BX444-Mc Gas Detector

USER MANUAL ACQUAHOME 32 B BLU

User Manual THR870CUK Programmable Thermostat

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

Room thermostat with Auto Timer, independent DHW

ThermoPlus AS2-RF & ASR-RF Installation Instructions

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

Cascade Sequencer. Control Installation and Operation Instructions. Infinite Energy Boiler Manual. Also read and follow: CS-IOM-1

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

Drayton Digistat +3RF

Operating and Installation Manual VRC 430f. Weather compensator controller with radio transmission. For the operator / for the heating engineer

CM907- TRV PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

irad Wireless Controller

RF Programmable Room Thermostat User Instructions

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

AUTO CM CM USER GUIDE

User Manual THR872CUK Wireless Programmable Thermostat

ESRTP4RF. RF Programmable Room Thermostat with TPI, Optimum Stop, Delayed & Optimum Start. User and Installation Instructions

ir-range 8G /03.15 Changes reserved.

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

Installation, Start-Up, and Operating Instructions

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

ST 53.1 User s manual

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

INSTRUCTION FOR THE USER THC V E OIL BLU

Model: RT510RF. Installation Manual

Model: RT310RF. Installation Manual

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

Digital Electronic Thermostat With RF

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

User Manual for model

DYGIZONE GJD910 Lighting Controller & Enunciator

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

Operating instructions

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

User Guide Y9420H Sundial RF 2 Pack 2

VMB1TSW Temperature sensor module for the Velbus system

ST9400A User Guide. Features

Self-learning Room Temperature Controller

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING

Programmable Towel Radiator Manual

Model: Available in : Sapphire Black and Glacier White. 1 Series

RADIO DRIVER. * _Rev.1* User guide. Wireless programmer. RADIO DRIVER zone RADIO DRIVER zones RADIO DRIVER zones

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

Digital Electronic Thermostat With RF

Modulating clock thermostat

ELECTRIC BOILERS FOR CENTRAL HEATING

AC&R Controller RWR Basic Documentation VR2002 for water to water heat pump units

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

ENGLISH. REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL

Dryer Controller M720

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

- Data Brochure Universal Reset Module 422

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Model: RT310. Installation Manual

Instruction manual. Remote control electric IR HEATER

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

G a

CM901 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

Safety & Installation Instructions

Model: Available in: Sapphire Black and Glacier White. 1 Series

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

COnDEnSInG BOIlERS TAU UNIT OIL USER parameters manual

Operation manual. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

Model: Touch-RS. 1 Touch-RS

Room Sensor [RBT-3C] Installation Instructions

Transcription:

PROGRAMMABLE 7-DAY THERMOSTAT Installation and user instruction This instructions to be retained by the user 1

Thank you for choosing Riello s weekly programmer.. This central heating control device is easy to fit, and with correct use, will deliver improved comfort levels in your home whilst saving you money. This thermostat is designed to be used only with heating controls system with a maximum switching load of 2A at 30VDC or 0,25A at 230VAC or with Riello boilers fitting a bus protocol connection If installing for someone else, please ensure that the instructions are handed to the householder. Warning: Please read this manual prior to installation or use. Shock Hazard: This unit must be installed by a competent person, in accordance with local regulation, or other relevant national regulations and codes of good practice. Always isolate the AC Mains supply before installing this unit. CE: This product is according R&TTE Directive 1999/5/EC Installation warning: This programmer can be used either as a central heating ON/OFF thermostat and as boiler remote control (only with selected Riello boilers), therefore is mandatory to determinate the correct working mode (denominated TYPE) before installation and setting. From the main menu select the TYPE parameter and those are the following option (the selection need the batteries to be done). 2

Description crt Room thermostat working with ON/OFF command to the boiler. Connect the cable to room thermostat connection on the boiler. Maximum switching load of 2A at 30VDC or 0,25A at 230VAC. Boiler remote control using a bus protocol to communicate with the boiler. Connect the cable to remote control connection on the boiler. crs To be used only when boiler is set in a continuous pump running mode. Room thermostat working with ON/OFF command to the boiler. Connect the cable to room thermostat connection on the boiler. Maximum switching load of 2A at 30VDC or 0,25A at 230VAC. rct To be used only when boiler is set in a zone valve management mode. Boiler remote control using a bus protocol to communicate with the boiler. Connect the cable to remote control connection on the boiler. Additionally the wired device activate the ON/OFF built in relay at any room heat request directly to the zone valve. Your programmer is a room thermostat (recognized by no house icon on display) type crt Your programmer is a boiler remote control (recognized by house icon on display) type 3

Programming button Fast DHW adjusting buttons ( only) Fast room temperature adjusting buttons Heating mode button 4

Display Adjusting buttons Heating mode button Temperature sensor Batteries flap 5

INSTALLATION AND OPERATING INSTRUCTIONS The installation of the device need two wires to connect to the boiler, the devise need the battery if working with type ON/OFF. Batteries are not needed is the type selected is. WARNING: REMOVE THE BATTERIES WHEN USED IN REC TYPE (REMOTE CONTROL) EXPLOSION CAN HAPPEN Important: these instructions should be read in conjunction with the appliance installation instructions. It is recommended that this device is installed by a qualified electrician. PACKING LIST QTY 7-day programmer 1 Anchors and screws 4 Double side adhesive 3 Instructions 1 Carton internal packaging 1 Batteries (used only in crt type) 2 NOTE: Eventual additional electronic boards necessary to connect the controller to the boiler main board are not included in this box and need to be purchased separately. PREPARATION: Isolate the appliance from the electrical supply and remove the appliance casing and PCB cover (refer to boiler installation instructions for specific details). 6

INSTALLATION OF PROGRAMMER Position the programmer on a wall surface away from obstructions and direct heat sources or draughts, in a room that is warmed by the heating system. The fixing of the transmitter can be done either with the anchors and screws or with the double sided adhesive (both supplied). See the diagram below as reference to drill the wall. screws to the anchors internally the box. See the diagrams below for removal from and re-assembly to backplate. Pay attention because it could be difficult to open, follow the diagram for an easier opening procedure. WARNING! DO not touch the printed circuit board of the transmitter as it contains electrostatically sensitive components. In the case of using anchors, the transmitter box must be open to fix the ELECTRICAL CONNECTION On the back side of the programmer, once open, there are 2 couple of connections. 7

Connection indicated as OT (printed on the PCB) = use this when use the programmer as remote control (type ) Connection indicated as RELAY (printed on the PCB) = use this when use the programmer as room thermostat (type crt). Important: never connect the OT+ contact to 230V supply to avoid the destruction of the bus circuit. Important: the link-wire (if fitted) must be removed from room thermostat terminals (both installation type) WARNING: select the equivalent programmer type as installed on the main menu and remove the batteries after if the type is selected. FUNCTIONS The Riello Programmable 7-day Thermostat has the following functions: Room thermostat (crt): for the display appearance in this mode, please refer to the relevant section of this manual. The internal temperature sensor detects the temperature and, comparing with the set point, switches ON or OFF the heating request (according the programmed timing). The temperature sensor is located on the left side of the item. Temperatures: there are two level of selectable temperature: Comfort temperature T1 and economy temperature T2 (T1 always > T2). Both are selectable. Additionally there is a third level of temperature indicated as frost protection temperature that is active all the time (the frost protection temperature is selectable only inside the technical menu). 8

T2 always > Frost protection temperature) Time: on the display it is possible to set and read the time (24 hours display mode) Day: on the display it is possible to set and read the day of the week Programming timing: it is possible by selecting the relative timing fascia to select the desired time. The programming is possible during 7 day 24-hours and the minimum time fascia is 30 minutes. The programming is possible in two separated temperatures: COMFORT (T1 ) and ECONOMY (T2 ). Status mode in crt: select the heating mode button for fast switching between the 4 status OFF AUTO PARTY - HOLIDAY. OFF mode, the heating request to the boiler is off, on display there is not equivalent icon, the heating layer and the programming fascia is off. With this mode only the frost protection function is active. AUTO mode: the heating request is according the programmed timing and room temperature. In AUTO mode it is possible to increase or decrease temporary the room set temperature by pressing the and buttons, only if the current time is inside in a heating ON fascia. The temporary new temperature set (T1) is maintained only inside the timing fascia. The next heating fascia will be back to the original T1 set temperature. It is possible to check the set temperature by pressing once the 9

or the buttons only if the current time is inside in a heating ON fascia. HOLIDAY mode with choice how many day off (by increasing or decreasing using the button and ). The heating request to the boiler is to maintain the economy temperature on the room (T2). The number of days off is considered on the day starting from midnight. After the counter down is ended the programmer switch to AUTO mode. PARTY mode automatically switch the programmer ON to comfort temperature (T1). This status is forced up to midnight, after, the programmer goes back to the programmed timing fascia. Remote Control (): for the display appearance in this mode, please refer to the relevant section of this manual. The internal temperature sensor detects the temperature and, comparing with the set point, calculates the most suitable boiler flow temperature according the climatic curve (only if the external sensor is fitted) and according the velocity the set temperature is reached. The programmer continuously communicates with the boiler control indicating the target flow temperature (the values not just an ON/OFF) according to the calculation made. With this type of communication it is possible also to adjust by remote the domestic hot water (DHW) temperature in case of instantaneous DHW production or DHW storage tank controlled by a dedicated sensor. The functions of this type () are the same as room thermostat type above 10

described. Additionally it is possible to have a feedback from boiler status and alarms. The display in type give more information according the already mentioned start up indications. The 4 status mode have additional functionality compared with the type room thermostat. Status mode in : select the heating mode button for fast switching between the 4 status OFF AUTO PARTY - HOLIDAY. OFF mode, the heating request to the boiler is off, on display there is not equivalent icon, the heating layer and the programming fascia is off. With this mode only the frost protection function is active. The DHW function is active and it is possible to increase or decrease the target temperature by pressing the and buttons. AUTO mode: the heating request is according the programmed timing and room temperature. In AUTO mode it is possible to increase or decrease temporary the room set temperature by pressing the and buttons, only if the current time is inside in a heating ON fascia. The temporary new temperature set (T1) is maintained only inside the timing fascia. The next heating fascia will be back to the original T1 set temperature. It is possible to check the target flow temperature communicated to the boiler (according the various calculations) by pressing once the buttons only if the current time is inside in a heating ON fascia. 11

In the case the outside sensor is fitted (external temperature displayed) the and buttons increase or decrease of equivalent degree indicated on display, the room comfort level (from 5 to +5) HOLIDAY mode with choice how many day off (by increasing or decreasing using the button and ). The heating request to the boiler is to maintain the economy temperature on the room (T2). The number of days off is considered on the day starting from midnight. After the counter down is ended the programmer switch to AUTO mode. PARTY mode automatically switch the programmer ON to comfort temperature (T1). This status is forced up to midnight, after, the programmer goes back to the programmed timing fascia. Other functions (common to crt and modes): Battery low Alarms and reset (only for type) Technical menu (only for experts) OPERATING INSTRUCTIONS The programmer is factory set as room thermostat type (crt). Most of the parameters are already set, at the start up it is necessary to set the time and the day (please note no solar fuse is precharge inside therefore if during the year there is time modification it must be adjusted). The following operation must done at start up END USER MENU (MAIN MENU) 12

Enter inside the end user menu pressing the button once. Use the button to escape at any time. Scroll inside the end user menu pressing any of the triangle buttons and press again the button to enter inside the single setting, the scrolling give access to the following settings: Attention: the TYPE of the device (that is part of the main menu selection) should have already been set by the installer as this set is according the installation made (ON/OFF device or Remote Control device). 13

icon Description Factory set value Setting the comfort (T1) and economy (T2) T1 = 21 C temperatures T2 = 16 C Setting the time Setting the day Setting the programming fascia Unset Unset Unset Setting the domestic hot water temperature (only type) 42 C type Setting the TYPE crt -- PL Setting the technical menu (password required) Setting the Domestic hot water programming daily fascia (only with boiler with tank and parameter 24 ON and only in 24hr time) -- 14

Set the target room temperature (T1 and T2). Use the and to increase or decrease, use the and to switch between T1 and T2. The value selected is automatically memorized moving at the next setting. Use the button to enter and exit. Set the time. Use the and to increase or decrease, use the and to switch between hours and minutes. Use the button to enter and exit. Set the day of the week. Use the and to increase or decrease. Use the button to enter and exit. Set the programming heating fascia. Use the to select the day (only ahead, not back). Use the to switch ON or OFF the layer T2 or T2+T1, once selected maintain the copy to the following 30 minutes pressing the button. Move ahead or back the point using the and buttons. Heating fascia are pre-set with day 1-5 from 6-8,30 and from 16 to 22 on T1and days 6-7 from 8-11 and from 16 to 23 on T1. The setting is made on 30 minutes 15

Set the target domestic hot water. Use the and to increase or decrease the value. Use the button to enter and exit. type Set the device installation type. Use the and to switch between the values (see the table at page 2 for details). PL Enter inside the technical menu. Password required. Use the and to increase or decrease the password code. (see specific paragraph for better details) Set the daily programming fascia for domestic hot water production (only for boilers installed with tank and sensor). Parameter active only if the parameter 24 inside the technical menu is set ON. Set the programming fascia in the same way used for heating fascia. The setting is possible daily, not weekly. The heating of the DHW tank will be done according the selected programmed fascia. Battery low When the controller feels that the battery are about to be exhausted, the battery icon will lit up. In this case the batteries needs to be changed in due time. If the battery completely run out of energy, or during the battery replacement, the settings will be kept in the controller memory, except for the time and the day 16

ALARMS Should anything occur during the functioning of the controller, a display will be shown in the main display, together with the spanner icon. In most of the cases it is sufficient to press the button to reset the system, but exceptions apply according to the following list: ALARMS RELATED TO THE CONTROLLER The following are alarms related to the controller only: A80 = room sensor broken. Replace the controller A81 = EEPROM alarms. Following this alarm after the reset, the set of factory parameters are recharged in the controller memory A83 = (only for mode) the cable between the programmer and the boiler is broken or not connected properly. There is no communication between receiver and boiler. Or programmer connected on the room thermostat boiler connection. A99 = too many resets. There have been more than 5 resets in 15 minutes. Following this alarm, it is necessary to reset the boiler directly on its dashboard and is not possible to do it from the controller. ALARMS RELATED TO THE BOILER (ONLY REC TYPE): The alarms are displayed as per the display of the boiler: refer to the boiler instruction manual for the meaning of the 17

symbols. REMARK: the alarms type A2X can be reset only from the boiler fascia. programmer make an automatically regulation using the room sensor. ALARMS RESET The reset of the alarms is done pressing the button on the programmer. CLIMATIC CURVES Below the climatic curves of the programmer. Curves from 0,2 to 0,8 are used when the boiler is set for low temperature (i.e. floor heating) Curves from 1 to 3 are used when the boiler is used for high temperature (i.e. radiator heating), Selection of the climatic curve can be made inside the technical menu only. The climatic curve function is active only if an external sensor if fitted to the boiler. If there is not external sensor fitted, the Boiler flow temperature External temperature 18

DISPLAY IN crt (ON/OFF) MODE: When the device is in its standard mode of functioning, the appearance of the display will be the following: The central heating symbol and bar is a proportional indication of the set-point of the desired temperature in the room. Each bar represents to 2 C. They will disappear when the central heating is turned OFF. The temperature display indicates the actual temperature measured inside the room The time display indicates the actual time The icon means that there is a heat request from the room to the boiler. The boiler will switch ON. The day icon indicates the actual day of the week 19

The central heating fascia bar is a permanent display of the functioning fascia set for the central heating set point setting. If a bar is completely blank, the set-point is the anti-frost level (central heating OFF). If only the lower part of a bar is black, the set point is the economy (T2). If the whole bar is black, the set point is the comfort (T1). They will disappear when the central heating is turned OFF. The day icon and the night icon indicate whether the current set point for the current time is night or day. The party icon is lit up when the party mode is selected. In this mode the central heating fascia bar will be completely lit up at T1 together with the day icon. After midnight, the display will turn back to the pre-set working fascia. The holiday icon is lit up when the holiday mode is selected. In this mode the central heating fascia bar will be lit up at T2 together with the night icon. After the holiday counter is over, the display will turn back to the pre-set working fascia. When the icon appears, the controller is working as to keep the anti-frost temperature. 20

DISPLAY IN (remote control) MODE: When the device is in its standard mode of functioning, the appearance of the display will be the following: The central heating symbol and bar is a proportional indication of the set-point of the desired temperature in the room. Each bar represents to 2 C.They will disappear when the central heating is turned OFF. In case of external sensor fitted, the bar is moved up and down according the room comfort level chosen. The temperature display indicates the actual temperature measured inside the room The icon means that there is a heat request from the room to the boiler. The boiler is ON with flame present. The house icon around the temperature display, indicates that the controller is set as a Remote Control () and appears only in this mode of functioning. 21

The display on the right side of the house indicates the external temperature reading, and it appears only when the outdoor sensor is correctly connected. The central heating fascia bar is a permanent display of the functioning fascia set for the central heating set point setting. If a bar is completely blank, the set-point is the anti-frost level (central heating OFF). If only the lower part of a bar is black, the set point is the economy (T2). If the whole bar is black, the set point is the comfort (T1). They will disappear when the central heating is turned OFF. The day icon and the night icon indicate whether the current set point for the current time is night or day. The domestic hot water symbol and bar is a proportional indication of the setpoint of the desired temperature when the boiler works in domestic hot water mode. Each bar represents 1 C. The party icon is lit up when the party mode is selected. In this mode the central heating fascia bar will be completely lit up at T1 together with the day icon. After midnight, the display will turn back to the pre-set working fascia. 22

The holiday icon is lit up when the holiday mode is selected. In this mode the central heating fascia bar will be lit up at T2 together with the night icon. After the holiday counter is over, the display will turn back to the pre-set working fascia. When the icon appears, the controller is working as to keep the anti-frost temperature. TECHNICAL MENU The device has the possibility to set a series of parameters to better adapt the controller to the installation. Following instructions are dedicated to expert personnel as they have a deep impact on the working mode of your boiler and your system. To enter inside the PL menu it is requested a password. From the end user menu, select the PL pressing the button. Increase or decrease the values up to reach the value 53 (that is the technical menu password). Once reached the value 53, press the button to enter. You are now inside the technical menu (only for expertise). Use the and to scroll the parameters list, below the sequence and the explanation of each parameter. Note: the visibility of the parameters depends of the type selected. 23

Par. Ref. Desc. Factory set value Operation 08 Max set point heating 85 C (30 C 85 C) Use the button to decrease and the button to increase the temperature value. The value is automatically memorized when moving to the next parameter. This parameter put a high limit on the maximum temperature value communicated to the boiler. 09 10 Min set point heating Climatic curve selection 30 C (30 C 85 C) 1.2 (see climatic curves) Use the button to decrease and the button to increase the temperature value. The value is automatically memorized when moving to the next parameter. This parameter put a low limit on the minimum temperature value communicated to the boiler. Use the button to decrease and the button to increase the climatic curve value (see below the climatic curves). The value is automatically memorized when moving to the next parameter. 24

Par. Ref. Desc. Factory set value Operation 11 Influence of temperature sensor 10 (0 20) Use the button to decrease and the button to increase the influence of room sensor on the calculation of the boiler flow temperature. 10 is the standard, higher values is good for pour insulation houses. The value is automatically memorized when moving to the next parameter. 13 Calibration of the room sensor Actual and crt Use the button to decrease and the button to increase the reference room temperature. Use this parameter in case of not proper installation of the device. The value is automatically memorized when moving to the next parameter. 14 16 Programmer reset Software release 0 Actual and crt and crt Use the button to move to value 1 and reset the device to a factory set values. Press the button to confirm the reset. This parameter just shows the software reference number on the device 25

Par. Ref. Desc. Factory set value Operation 17 Choice C or F C and crt Use either the button and the button to switch to F or C. all the temperatures values wil l change. In case of F values there is not equivalent letter F displayed The value is automatically memorized when moving to the next parameter. 18 Hysteresis OFF 0.1 C (0.0 2.0) and crt Use the button to decrease and the button to increase the hysteresis OFF of the device. The value is automatically memorized when moving to the next parameter 19 Hysteresis ON 0.5 C (0.0 2.0) and crt Use the button to decrease and the button to increase the hysteresis ON of the device. The value is automatically memorized when moving to the next parameter 20 Frost protection temperature 5 C (3 C 10 C) and crt Use the button to decrease and the button to increase the frost protection temperature limit. The value is automatically memorized when moving to the next parameter 26

Par. Ref. Desc. Factory set value 21 Alarms history actual 22 23 24 26 Boiler TSP reading Anti- Legionella function Clock on DHW Reading PCB values actual OFF OFF Actual only Operation Use the and the button to scroll last 9 alarms code memorized on the device. Unused Use the and the button to switch ON or OFF the legionella function (function active only with boiler connected to a tank with sensor control). Use the and the button to switch ON or OFF the programming time on the DHW production via a tank with sensor. (function active only with boiler connected to a tank with sensor control). If selected ON, on the end user menu will appear a dedicated programming fascia to be set (programmable daily fascia only) Use the and the button to scroll the reading of values from boiler PCB: FLUE X C is the flues actual temperature, HOUr XXX are hours (multiply by 10 the displayed value) of working in a specific conditions (refer to boiler manual). 27

TECHNICAL SPECIFICATIONS LIMIT OF SETTING OF THE TEMPERATURES: Anti-frost temperature: 3 C 10 C T2: anti-frost temperature 35 C T1: T2 35 C DHW (if applicable): 37 C 60 C Room temperature: 5 C 30 C READING LIMITS Outdoor sensor: -10 C 40 C Room sensor: -10 C 40 C PROGRAMMER relay Switching capacity (crt only): Min 1mA, Max 2A at 30 VDC Max 0,25A at 230 VAC Power rating: 2 x 1,5AA - Alkaline batteries (only for crt type) OT+ contact: for bus protocol only. Never supply with 230V this contact. Remove batteries once selected the (OT+) type Riello S.p.A. Via Ing. Pilade Riello, 7 37045 Legnago (VR) Italy www.riello.com Riello reserve the right to change specification without prior notice - Consumers statutory rights are not affected. Manual Issue 12/2012 rev.01 28