PRODUCT MANUAL FIRE EXTINGUISHER. Carbon Dioxide 6.5, 9 & 22.5 Kg Capacity Trolley Mounted (45 kg also as a non standard)

Similar documents
PRODUCT MANUAL FIRE EXTINGUISHER

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 7 Extinguisher Types Revised

FIRE EXTINGUISHERS. Chapter 2. - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator

DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE

FIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES

Institute for Plasma Research Welcomes you all on

Portable Fire Extinguishers

CHAPTER 15: FIRE PREVENTION & AWARENESS POLICY

Technical Data Sheet No. JS-SM-38 DOCUMENT TITLE 3.5KG CARBON DIOXIDE FIRE EXTINGUISHERS

Technical Data Sheet No. JS-SM-40 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

OPTIONAL INFORMATION PORTABLE FIRE EXTINGUISHERS SELF INSPECTION CHECKLIST

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

Extinguishers. Commercial Industrial High rise buildings

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

NUCLEAR POWER CORPORATION OF INDIA LIMITED (A Government of India Enterprise)

WHEELED STORED PRESSURE

Flammable liquids, gasoline, oil etc. Advantages. 21 B. Ø 920 mm 21 B. Ø 920 mm

SOUTH AFRICAN NATIONAL STANDARD

Portable Fire Extinguishers

Fire Extinguisher Use. Fire Extinguisher Review. and Fire Safety

Twin-Agent Fire Fighting/Securing Systems Specifications

IGS-M-SF-01(0) IGS. Iranian Gas Standards. CO2 Fire Extinguisher, Portable Type

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER

Risk Management Resources

"USING FIRE EXTINGUISHERS"

TRAINING BULLETIN September 1, 2010 PURPLE K DRY CHEMICAL EXTINGUISHER 1. INTRODUCTION

WHAT IS FIRE? In order to have a fire, there must be three elements: Heat -- enough to make the fuel burn

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

Technical Data Sheet No. JS-SM-33 DOCUMENT TITLE. 2.0kg ABE TYPE STORED PRESSURE DRY POWDER PORTABLE FIRE EXTINGUISHER MODEL: R2.

Using Fire Extinguishers. Leaders Guide and Quiz

GUILFORD COUNTY SCHOOLS

Fight or Flee? Extinguisher Basics Extinguisher Use Extinguisher Placement and Spacing Hydrostatic Testing OSHA Requirements Test Your Knowledge

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

Risk Management Department. Fire Extinguishers

Emergency Response Procedures Contractors Instruction. Building nformation

DATASHEET HIGH VOLUME LONG RANGE FOAM MONITOR GPM

Subchapter 7. General Industry Safety Orders Group 27. Fire Protection Article 157. Portable Fire Extinguishers. Return to index New query

WHEN a fire starts, the first few seconds are critical. Thus, fire

Progressive Safety Services LLC 2

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

Rambo CAST IRON RING BURNERS OPERATING INSTRUCTIONS. C40LP 3 Ring Burner C50LP 4 Ring Burner

Fire Extinguisher Training

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

TAMUCC Fire Safety Training

(Material correct at 1/11/2011)

Fire Extinguisher Training

Model Policy On Portable Fire Extinguishers (Ontario Version)

SAFETY THE BEST FOR YOUR EQUIPMENT

SECTION AUXILIARY HEATER

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

Tender document for Supply/ Installation of New Fire extinguishers & Refilling TENDER NOTICE

Three elements of fire. Heat Oxygen Fuel. Remove one of the three and the fire is extinguished.

Aerosol Type Fire Extinguisher Aerosol Type Fire Extinguisher

Table Top Patio Heater

PORTABLE SMART WASHER

CL & CLG Clamp Mount Mixers

Safety Policy and Procedure

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

FIre Extinguishers. K-GUARD Wet Chemical Fire Extinguishers Manual INSTALLATION 2014-DEC-29 REV. 03 PAGE 1 EXTINGUISHERS

FIRE SUPPRESSION SYSTEM

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

Inert Gas Fire Extinguishing System

Salt Lake Community College FIRE EXTINGUISHER TRAINING

Operation Refilling and Maintenance Manual SFS-10. Hatsuta Seisakusho Co. Ltd. SFS-10-E1404-(A-012)

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

Fire, extreme heat, smoke, toxic fumes, noise, falling objects, uneven terrain, debris,

Design and Supply of Fire Equipments. External Fire Fighting Systems.

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers

FIRE AND FIRE FITTING By Mr. Prashant Sansare

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

WSU-TFREC Fire Safety Training

Safety Manual Section 7 Fire/Life Safety

B.) Accident -- Any suddenly occurring unintentional event which causes injury or property damage.

OWNERS SERVICE MANUAL

E4218 Fire Extinguisher Basic Training. Leader s Guide

What are the four things that must be present at the same time to produce fire?

Fixed Fire Extinguishing Equipment and Systems

Model K 5800 G Part No

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

OPERATING INSTRUCTIONS AND OWNERS MANUAL GAS-FIRED INFRA-RED TANK TOP HEATER

Model HD 3000 Part No High Pressure Washer Operator Manual

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

SOUTH AFRICAN NATIONAL STANDARD

FIRE TETRAHEDRON. Consists of 4 Sides. Oxygen. Fuel. Chain of reaction

contents iii Drilling Tools 27 Adjustable Choke 27 Automatic Drillers 29 MWD and LWD Tools 30 How They Work 30 Uses 30

FIRE SAFETY. Department of Chemical Engineering College of Engineering

A Guide for Meeting NFPA 10 Subsection

Fire Safety PPT-SM-FIRESFTY V.A.0.0

Statement of Policy. Fire Extinguisher Use Policy #: SMS-041

Flammable Materials SC-127

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

High Pressure Washer Operator Manual. Specifications Model HD 2700 DH/DB

TYPES OF EXTINGUISHING AGENTS

OCCUPATIONAL PROFILE FIRE FIGHTING EQUIPMENT TECHNICIAN (Special Class Electrician, Fire Detection System Designer) CURRICULUM CODE:

COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

Workplace FIRE SAFETY

MERCURY HD-22 AUTOSCRUBBER Safe Operations

Affix Stamp Dear Customer,

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

Transcription:

PRODUCT MANUAL FIRE EXTINGUISHER Carbon Dioxide 6.5, 9 & 22.5 Kg Capacity Trolley Mounted (45 kg also as a non standard) Kanadia Fyr Fyter Pvt Ltd Laxminagar, Ghatkopar (E), Mumbai -400 075 Page 1 of 6

[KANEX FIRE EXTINGUISHER] Carbon Dioxide 6.5, 9, 22.5 & 45 Kg Capacity INTRODUCTION This manual contains product description, installation, operating and inspection for the KANEX Carbon Dioxide (CO 2 ) type Fire Extinguisher of capacity 6.5, 9, 22.5 & 45 Kg by weight of gas. This model is designed to extinguish B and C type fires involving material like Petro Chemical products, Paints, Resigns, Pigment, Varnish, Gases in the compressed form like Oxygen, Acetylene, LPG, CNG and Electrical as well as electronic equipments. PRODUCT DESCRIPTION The principal advantage of KANEX CO 2 (Carbon Dioxide) Fire Extinguisher is that the agent does not leave a residue after use. CO 2 gas extinguishers are characterized by their high performance for fires, as it is non-conductive, clean and safe, ensuring minimal damage to electrical equipment and furnishing. Carbon Dioxide gas is of IS 15222:2002, extinguishing agent, colorless, odorless, non-toxic, provide rapid knock down of industrial fire. Carbon Dioxide is retained under its own pressure in a fluid condition at room temperature. Gas cylinder of IS 7285:1988, is seamless having test pressure of 250 bar and working pressure of 150 bar at 15º C. The material of cylinder is Manganese Steel DS658 of Fire Red painted and neck thread size is 25.40 mm. Filling ratio: Filling Ratio is the ratio of mass of liquefiable gas that is allowed to be filled into the container in view of safety considerations to the mass of water required to fill (water capacity) at 15º C. The discharge of the CO 2 gas is Valve controlled. The Valve is made of forged Brass material and of IS 3224:2002 having valve inlet and outlet to meet the cylinder neck threads. The valve is either Squeeze Grip type or Wheel type. An aluminum Siphon pipe of IS 738:1994 is fitted to the discharge valve by swivel joint such a way that it remains inside the cylinder. A Wire Braided Hose Pipe (length 1m for 6.5 Kg, 2m for 9 Kg and 5 m for 22.5 & 45 Kg) and nonconductive of electricity Discharge Horn of material Polyethylene are connected to get discharge performance with no freeze burn, with greater directional control of CO 2 gas discharge. Page 2 of 6

INSTALLATION Installation of the KANEX Fire Extinguisher requires that the equipment be uncrated, placed in it s proper position and secured in place with caster locks. One set of accessories is packed with fire extinguisher for use in installation. Please compare your supplied accessories with the following list. Discharge Horn Discharge Hose Pipe (length: 1m for 6.5Kg, 2m for 9 Kg and 5m for 22.5 & 45Kg) Connecting Pipe PVC Handle Washer Trolley (Carrying Handle) Wheel Carriage Pair of Wheels Connecting nut & bolts To assemble the Fire Extinguisher, fit the trolley mountings that are upper carrying handle and lower wheel carriage with cylinder. Provide the pair of wheel to the wheel carriage. Connect Hose Pipe with valve placing washer between them. The other side of hosepipe is to be connected by Discharge Horn keeping connecting pipe and PVC handle between them. Ensure that the all above accessories are firmly screwed with each other and also with valve. For installation pick up a convenient distance that shall not be longer than 15 meter from site and such a way that fire extinguisher can be easily driven from that location while required to fight with fire. OPERATION To be operated the Kanex fire extinguisher is held in an upright position The safety sealing device is removed The locking ring pin is pulled Ensure that the Discharge end is firmly held in the hand The operating wheel of valve is turned anti clock wise direction The discharge should be directed at the base of the flames On fires involving electrical or electronics equipments, discharge should be directed at the source of the flames. There are two methods of directing the discharge to adopt the better extinguishment a) The most commonly used method of agent application on contained flammable liquid fires is to start at the near edge and direct the discharge in a slow, side-to-side sweeping motion, gradually progressing toward the back of the fire. b) The other method is called Over head application. The discharge horn is directed in a dagger or downward position (at an angle of 45 degrees ) toward the center of the burning area. Page 3 of 6

Generally, for spills fire, the side-to-side sweeping motion could give better results. The discharge should be applied to the burning surface even after the flames are extinguished to allow added time for cooling and to prevent possible reflash. PRINCIPALS OF OPERATION The Carbon Dioxide agent extinguishes by diluting the surrounding atmosphere with an inert gas so that oxygen levels are kept below the percentage required for combustion. The agent is self-expelling and in its vapor and solid phase. The minimum discharge time for hand portable capacity 6.5, 9, 22.5 & 45 Kg gas varies from 10 to 20, 15 to 36 & 20 to 60 seconds respectively. The discharge jet range of the discharge stream is approximately 2 ft to 8 ft. INSPECTION AND RECHARGING The owner or the designated agent or occupant of a property in which fire extinguishers are located shall be responsible for inspection and recharging. INSPECTION: Fire Extinguisher shall be inspected when initially placed in service and then after at approximately 30-day intervals. The inspection should be in following point of view. Safety Seals not broken or missing Fullness determining by weighing Visually damage, corrosion, leakage or clogged discharge connection Condition of horn, Hose Pipe, trolley mountings, mobility and fire extinguisher itself. RECHARGING: It is important to reenergize the Fire Extinguisher as soon as possible to eliminate the potential of recombustion or fire. Each fire extinguisher shall have a tag or label securely attached that indicates the month and year recharging was performed and that identifies the person performing the service. Inspect monthly clean discharge fittings and weight. If weight is found 10% less than stamped weights, embossed in cylinder, send the fire extinguisher for refilling to Kandia Fyr Fyter Pvt Ltd. Page 4 of 6

Extinguisher Parts [Carbon Dioxide (Capacity 6.5 Kg)] 01 C6.5-0100 Body Steel 01 No. 02 C6.5-0200 Control Valve Brass 01 No. 03 C6.5-0300 Siphon Tube Aluminum 01 No. 04 C6.5-0400 Carrying Handle M.S. 01 No. 05 C6.5-0401 Wheel carriage M.S. 01 No. 06 C6.5-0402 Wheel Solid Rubber 02 No. 07 C6.5-0403 Wheel Washer M.S. 02 No. 08 C6.5-0404 Cotter Pin M.S. 02 No. 09 C6.5-0405 Nut & bolts M.S. 04 No. 10 C6.5-0500 Discharge Hose Rubber braided 01 No. 11 C6.5-0501 Connecting Pipe M.S. 01 No. 12 C6.5-0502 Plastic Handle Poly ethylene 01 No. 13 C6.5-0503 Discharge Horn Poly ethylene 01 No. 14 C6.5-0504 Washer Plastic 01 No. [Carbon Dioxide (Capacity 9 Kg)] 01 C9-0100 Body Steel 01 No. 02 C9-0200 Control Valve Brass 01 No. 03 C9-0300 Siphon Tube Aluminum 01 No. 04 C9-0400 Carrying Handle M.S. 01 No. 05 C9-0401 Wheel carriage M.S. 01 No. 06 C9-0402 Wheel Solid Rubber 02 No. 07 C9-0403 Wheel Washer M.S. 02 No. 08 C9-0404 Cotter Pin M.S. 02 No. 09 C9-0405 Nut & bolts M.S. 04 No. 10 C9-0500 Discharge Hose Rubber braided 01 No. 11 C9-0501 Connecting Pipe M.S. 01 No. 12 C9-0502 Plastic Handle Poly ethylene 01 No. 13 C9-0503 Discharge Horn Poly ethylene 01 No. 14 C9-0504 Washer Plastic 01 No. [Carbon Dioxide (Capacity 22.5 Kg)] 01 C22.5-0100 Body Steel 01 No. 02 C22.5-0200 Control Valve Brass 01 No. 03 C22.5-0300 Siphon Tube Aluminum 01 No. 04 C22.5-0400 Carrying Handle M.S. 01 No. 05 C22.5-0401 Wheel carriage M.S. 01 No. 06 C22.5-0402 Wheel Solid Rubber 02 No. 07 C22.5-0403 Wheel Washer M.S. 02 No. 08 C22.5-0404 Cotter Pin M.S. 02 No. 09 C22.5-0405 Nut & bolts M.S. 04 No. 10 C22.5-0500 Discharge Hose Rubber braided 01 No. 11 C22.5-0501 Connecting Pipe M.S. 01 No. 12 C22.5-0502 Plastic Handle Poly ethylene 01 No. 13 C22.5-0503 Discharge Horn Poly ethylene 01 No. 14 C22.5-0504 Washer Plastic 01 No. Page 5 of 6

[Carbon Dioxide (Capacity 45 Kg)] 01 C45-0100 Body Steel 01 No. 02 C45-0200 Control Valve Brass 01 No. 03 C45-0300 Siphon Tube Aluminum 01 No. 04 C45-0400 Carrying Handle M.S. 01 No. 05 C45-0401 Wheel carriage M.S. 01 No. 06 C45-0402 Wheel Solid Rubber 02 No. 07 C45-0403 Wheel Washer M.S. 02 No. 08 C45-0404 Cotter Pin M.S. 02 No. 09 C45-0405 Nut & bolts M.S. 04 No. 10 C45-0500 Discharge Hose Rubber braided 01 No. 11 C45-0501 Connecting Pipe M.S. 01 No. 12 C45-0502 Plastic Handle Poly ethylene 01 No. 13 C45-0503 Discharge Horn Poly ethylene 01 No. 14 C45-0504 Washer Plastic 01 No. Page 6 of 6