Classic Valve Design

Similar documents
Fratech Multipath-IP

Philco Restoration

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

Product No. PLMBZ209GCA Market North America Color stainless steel Volts 120 Watts 1200 Wiring Diagram Owner's Guide TINSEB477MRR0

Installation, Operating and Maintenance Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

HORIZONTAL COOKING SERIES: 700 / 900 S.A.V MAINTENANCE & AFTER SALES WORK PPS-3WE711911CH

STRONG International FP-350 Operation and Installation Manual

CP CP

UV PRO 15, ozone generator instruction manual ****IMPORTANT****

Single Channel Video Receive Unit with two Bi-directional Data Channels and one Bi-directional Alarm Channel for a Multimode Fibre Link

LC3000 Level Controller Installation and Maintenance Instructions

100 Series Maxi Internal Filters

JENCO ELECTRONICS, LTD.

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

SA SIREN AMPLIFIER

Fratech Multipath-IP STU

PIASECKI AIRCRAFT CORPORATION TECHNICAL MANUAL OVERHAUL WITH PARTS BREAKDOWN AIRCRAFT OVEN - P/N X-006 Rev: B

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

mtc001 Thermocouple Converter

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Cable Actuated Sensor Industrial User Scalable VDC Output

EFFICIENT LONG LIFE & ENERGY SERIES

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Victoreen Primalert 35 Area Radiation Monitor

Advance Optima Module Magnos 17

SC-6 Six Supervised Control Module

Air Cooled Scroll Compressor Condensing Unit

INSTALLATION INSTRUCTIONS

RTD TEMPERATURE SENSING SYSTEM

Thermal Devices, Inc. Mount Airy, Maryland USA C D E F. Typical Maxiband Clamping

Colour also can display the time Build a LED colour clock

Ohm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

Raychem Overvoltage Devices. ROV14, ROV14H, ROV14E 14mm Series Metal Oxide Varistors

Smoke Check Service Manual

Dual System with 2x Independent Channels each of :

Solstice Kit Assembly Guide

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

OVERVIEW ANNUCIATOR POINTS

CONTROL BE MADE CHANGES MAY NOT. Page 1

MONITOR GF200 Vented Heating System. Service Manual

CAR BURGLAR ALARM K3504

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

1 General Description

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Smoke Detector - NEW. page 1

WARRANTY AND INSTRUCTIONS

VAP304 PRO INSTALLATION & OPERATION MANUAL

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers

CHILLER. Operator s & Installation Manual

Service Bulletin Trucks Date Number Page

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Installation Guide. Maximum Area 20m 2

Vance Dickason s LDC6 Home Theater System #

AE/AH R410A Window Air Conditioners & Heat Pumps

GM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K)

FOUR DOOR BOTTOM MOUNT REFRIGERATOR MODELS:

Requires: 80 cc gasoline engine, 4-channel radio w/ 6 standard servos. Specifications. * Specifications are subject to change without notice.

Exterior Tankless Gas Replacement Parts List

FL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A)

ADDENDUM. xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION GENERAL APPLICATION INFORMATION

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

Raychem Overvoltage Devices. ROV05, ROV05H 5mm Series Metal Oxide Varistors

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

Thank you for your purchase of the Soul-Vibe!

PS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90%


SA SIREN AMPLIFIER WITH MECHANICAL TONE

FEC400 Series. Installation Manual

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

SA300 Amplifier OWNERS MANUAL

Ohm Metrics. Instruction Manual. Model CM400 Series. Continuous Workstation Monitors

Cable Actuated Sensor Industrial Incremental Encoder Output

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

USER MANUAL Table of Contents

AXE102 PICAXE-08M2 Alarm / Steady Hand Kit

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

MP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

DATASHEET. Burner control unit FDA 601x

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

20 Light Remote Annunciator

INDICATOR LAMPS & LED REPLACEMENT LAMPS

PS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%

FIREYE FLAME SCANNERS

* If the infiniti UV Water Treatment System has an S2 Starter, it is fully interchangeable with the UV Lamp with Glow Starter.

Requires: 80 c.c. gasoline engine, 4-channel radio w/ 6 high torque servos. Specifications sq in / 182 sq dm

2-way floorstand. 902 i. 1x 165mm alu/cpc. mid/bass 1x 25mm alu/dome tweeter. recommended power: sensitivity 89dB

LAE10 LFE10. Use. Series 02

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

SERVICE MANUAL REFRIGERATION

Transcription:

PAS Purist Phono Stage Designed by Norman Koren (aka PAS-K Phono) for the Dynaco PAS2, PAS3, PAS3X Classic Valve Design

Classic Valve Design assumes no responsibility for circuit or user damage from the use or misuse of these boards or any other product. We simply provide these on an AS-IS basis with workmanship quality as the only thing guaranteed at this time. This product is designed for and use around LETHAL VOLTAGES. We assume the user has a reasonably competent grasp of line operated electronics at the time of sale. * Dynaco is a registered trademark of Panor Corporation * * Board design is Norman Koren. Classic Valve Design is an authorized dealer *

INTRO The Dynaco PAS series of pre-amplifiers has been one of the most successful and popular pre-amplifiers in history. They are reliable, hold their resale value and are incredibly popular blank slates to modify. The PAS-K phono board is an upgrade for the original PAS series of pre amplifiers designed by Norman Koren. Due to the fact this board uses three instead of two tubes, it is also highly recommended that if you use your 12X4 rectifier, that you install a secondary (12.6V, 500mA - Hammond 166G12) transformer to power its heater and the pilot lamp, if you do not convert to a LED power indicator. If you convert to an LED one (order CK-57), the recommended auxiliary transformer is 12.6V @ 300mA (Hammond 166F12 or 166F12C/D is fine). The 166F12 transformer can be mounted across the hole left by the can capacitor if you use our PAS Regulator PCB (order CK-54), or one of the many capacitor boards available on the internet. If you wish to keep the stock can capacitor, mount it on the back near the existing PA-211 power transformer (but do not block the vent holes). The 166G12 must be mounted externally (unless you're good at making fancy brackets). The old selenium rectifier and tubular capacitor heater power supply can NOT handle the extra tubes of these board. You will need to at least upgrade the rectifiers to modern silicon rectifiers for that. The 3A rated 1N540x series (like 1N5408) are commonly available and lend themselves to that duty well (the 1A, 1N400x series (like 1N4007) can't handle the cold-heater surge of a 3+3 arrangement and would soon fail, perhaps damaging the PA-211 power transformer). We will discuss more on heater arrangements later on in this manual, as well as some options for powering an odd-number of tube heaters.

Parts List (numbering follows the original Koren schematic) (quantities for resistors and capacitors are for one channel only) Resistors: R1S: 47K (cartridge load - use quality resistor) R1G, R2G: 1Meg, ½W R1GS: 10K, ½W R1C: 1K, ½W R1P: 150K, ½W R2C: 750 ohms, ½W R2P, R5C: 120K, ½W R1A1: 86.6K, 1% R1A2: 2.2Meg, 1% (2.21Meg is fine. It's the closest 1% value) RPL: (volume control of PAS. If used as a separate circuit, use 100K, ½W) Capacitors: C1G, C1P: 100n, 400V film C1M: 39pF, 500V silver mica C1A1: Parallel 820pF and 56pF, 500V silver mica C1A2: Parallel 2200pF, 470pF and 180pF, 500V silver mica C5C: 0.47uF, 400V polypropylene film (capacitors with higher voltage ratings here are OK. Polystyrene for Silver Mica for C1A1 and C1A2 are OK) Misc: CON1, 2, 3: Terminal blocks, 5.08mm, 3 position PCB. CON4, 5, 6: Terminal blocks, 5.08mm, 2 position PCB. (can be same as above [2 pos.] unless you are powering with 6.3V from another supply) Sockets Heater Balancing Resistor: 68 ohm, 3W resistor if your PAS has an oddnumber of signal tubes (like 2 on the phono board, 3 on this one = 5). Installation/use described in Heater Wiring.

Assembly Assembly is straight forward, though there is a couple items of note to make your life easier: 1) If you are powering the unit from the standard PAS doubler, you can use a 2 position terminal block for CON1, 2 and 3 by placing them on positions 4 and 5, ignoring 9 completely. 2) A large physical size of Cout can hamper installation. If you are using large capacitors for Cout, install them after you have mounted the line board on your PAS chassis. Heater Wiring The Dynaco PAS uses a voltage doubler circuit to turn the 12V heater winding of the PA-211 into 24V. Dynaco then runs the heaters of the 12AX7's on each board in series and powers them with higher voltage and lower current. The reason for this is simple the PAS has limited space and the PA-211 power transformer had to fit in. To have made the 12V winding for the current required by all the tube heaters, would have required a core larger than would have fit in the PAS. Since the 12AX7 draws 150mA from 12V, putting two in series will also draw only 150mA, but require 24V. It is far easier to wind a small power transformer for higher voltage than it is for higher current. This works well for an even number of tubes, but what about an odd number? We need to simulate another tube heater with a resistor. That's where the 68 ohm, 3W heater balancing resistor comes in handy. If you are using the Koren or other 3 rd party phono board, the even number of signal tubes is maintained. But if you are using a two-tube linestage board, you will need the balancing resistor.

Heater Wiring for Two 3-Tube Boards Connector designations are for two of our Koren boards, but will vary for your type.

Heater Wiring for Mixed 2 and 3-Tube Boards Use of the heater balancing resistor when mixing 2 and 3 tube boards in your upgraded PAS.

Why all this fuss over heaters? Why the need for an auxiliary transformer if you want to keep your stock pilot lamp and 12X4? Let's do some math... PA-211 12V winding rating: 800mA Stock Dynaco: 12AX7 x 4 = 300mA (two groups of two in series) 12X4 x 1 = 300mA #57 bulb = 240mA TOTAL = 840mA This does not include the I 2 R losses of the heater voltage doubler. As we can see, the heater winding is taxed as it is. Let us take the 12X4 and pilot lamp and give them their own transformer. Now, we can add more signal tubes. 12AX7 x 6 = 450mA (three groups of two in series) That's it! So, why not add the 12X4 again and use a LED pilot? You can, but with even further reduced heater voltage to your 12AX7's. With 450mA being drawn from the doubler, it's typical each heater sees.7 to 1V less than its rated 12.6V. It's just the nature of doubling and losses. Even if you mix a 3 and a 2 tube board, current draw will remain the same (the extra "tube" power is just burned in the heater balancing resistor) Documentation written by Gregg van der Sluys, Classic Valve Design www.classicvalve.ca Revision 1 / 3-23-2011