PTWS position, single drive Dissolution Tester

Similar documents
PTWS 1220 USP/EP Tablet Dissolution Testing Instrument

PTWS 620 USP/EP Tablet Dissolution Testing Instrument

PTWS 120D USP/EP Tablet Dissolution Testing Instrument

Dissolution Testing. Portfolio Overview Tablet Dissolution Testing.

LABOKLAV. Autoclaves Made in Germany

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Agilent Dissolution Seminar Series

The right temperature worldwide NEW. LAUDA Integral XT. Professional thermostating for pilot plant and mini-plant purposes. Product information

Rotavapor R-220 Pro Technical data sheet

Chromatographic Air circulated Refrigerator, two-door TC 603

Hotplates, Magnetic Stirrers and Stirring Hotplates

N-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features:

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

DELOMATIC 400, DM-400 HYDRO

Platelet bags constant shaking for long periods of time.

Rotavapor R-220 Pro Technical data sheet

Model KBWF 240 Growth chambers with light and humidity

VM-3000 Mercury Vapor Monitor

Laboratory Refrigerator/Deep Freezer TC 802

Symphony Quick Start Manual Document: Revision: A Distek Inc. Quick Start Manual

Constant climate chambers

Constant climate chambers

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Constant climate chamber with ICH-compliant illumination

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

PHARMACEUTICAL INDUSTRY CLEANING SYSTEMS

Rotary Evaporators designed

Constant climate chamber with humidity

Mercury Vapor Monitor VM-3000

Multifunctional individualists

NanoReady. Micro UV-Vis Spectrophotometer

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

VM-3000 Mercury Vapor Monitor

Chromatographic Air circulated Refrigerator, two-door TC 603

Model KBWF 720 Growth chambers with light and humidity

2017 BROCHURE. Bioreactor / Fermentor

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

Systems. Visit us at

Reacti-Therm I and III Heating/Stirring Modules

MEDIACLAVE. Fast, reproducible and safe media sterilization

Model S FT-IR SPECTROMETER

Ingenieurbüro M.ZippererGmbH

Constant climate chambers

Drying and heating chambers

QuadraTouch Pro Software Manual Dryer Control System

Laptop / PC Programming Manual

COMPLETELY AUTOMATED HYDROLYSIS

AS950 REFRIGERATED SAMPLERS

UC152 and US152. Key Features. Hotplate with Stirrer, UC152 US152. Technical Specification. Ordering Information

Hotplate/stirrers. Hotplate stirrers

User Guide Vision Dissolution Testers A

MST sterilizer overview

Thermostats designed

EnvironmentalMonitoring

Constant climate chambers

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

Plant growth chambers

HI COD REACTOR and Test Tube Heater 2008 Series

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

FN 032/055/120 DRY HEAT STERILIZERS / OVENS FN 300/400/500 DRY HEAT STERILIZERS / OVENS KD 200/400/700 OVENS EV 018 VACUUM OVEN

Fire control panel detect 3004 plus and accessories

WHO PQS-Code E006/016. Q-tag CLm doc USB Multi- Limit Temperature Indicator

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

2016 Catalogue. Bioreactor / Fermentor

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

LineGuard 2300 Program User Manual (FloBoss 107)

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

SHAKING WATER BATHS ENGLISH

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Modular Circular Polarimeters

ß-Aerosolmonitor FHT 59 C

TORREY PINES SCIENTIFIC, INC.

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

STABILITY ICH. ICH Stability Tests

Intelligent. Evaporation.... no task too big

Huminator II. Precision Humidity Generator. ww.testo.in

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

BATHS STIRRERS HOTPLATES HEATING MANTLES HOTPLATES

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

Photo Stability Chamber

Steam sterilizer AHS-75-DRY

Call stations and extensions

FITOCLIMA 600 & 1200 PHARMA

Focus 4010\ Focus 4010 HT porcelain firing furnace

Immersion Cell (with Small Volume Vessel) User Guide Rev. C

Dryer Master Inc. Dryer Master AM 3. Product Manual

WHO PQS-Code E006/020. Fridge-tag 2 Storage temperature monitor with USB port

Hennecke description of day tanks and metering equipment used in conjunction with Rotamats supplied to Trane (Vidalia, GA)

Intelligent. Evaporation. Premium Safety Standards Superior Ease of Use Reduced Cost of Ownership

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

Stability Chambers & Rooms

Transcription:

PTWS 620 USP/EP Tablet Dissolution Testing Instrument The PTWS 620 is a 6 + 2 position, single drive tablet dissolution testing instrument for solid dosage forms as described in USP chapter <711/724> and EP section<2.9.3/4> as well as the DAB/BP and Japanese Pharmacopeia section <15>. The USP monograph <1092/2.4.2> lists visual observation of the dissolution behavior as essential for identifying variables in the formulation or manufacturing process. The six vessels in the front row of PTWS 620 offer optimal visibility of the samples. User Interface PTWS 620 6 + 2 position, single drive Dissolution Tester In keeping with our cutting edge design, a large color, touch screen allows control of the various mechanical features of the instrument such as the tool stirring speed, lift drive and heater. The instrument control is menu driven. Status messages and color changes on the display inform the user of the status of critical instrument parameters, e.g. bath target temperature not reached. A status bar provides a quick overview and uses the familiar traffic light system green yellow red. Access to the instrument can be password controlled if required. If certain operational parameters form a regular feature of the daily routine, then these can be incorporated into a test method for faster set up. These parameters can be tool speed, target bath temperature, sampling time points and so on. The test method memory capacity is almost limitless. As soon as the test is started, a screen saver can be activated with the most important information displayed in large script so that this information remains visible even at time when the operator is not standing directly in front of the instrument. Pharma Test Apparatebau AG Siemensstr. 5 63512 HAINBURG GERMANY T: +49 6182 9532-600 F: +49 6182 9532-650 info@pharma-test.de www.pharma-test.com THE PHARMA TEST GROUP Version 2.0 1 of 8

Stirring Tools The PTWS 620 uses the Pharma Test MonoShaft design. Tools consist of the main shaft plus interchangeable tool heads (adapters). The main shaft remains in place in the instrument regardless of the tool head being used. The clearance of each tool from the vessel base will always be correct once the main tool shaft has been installed and fixed in its position. A wide variety of different stirring tools is available while the standard configuration includes USP/EP App. 2 Paddle stirrers. Vessel Centering System The PTWS 620 features a three-point individual centering system for each dissolution vessel (picture shows view from below). The vessels are held in position by three adjustable noses and are inserted into the instrument support framework. Each vessel is correctly centered against the stirring tool, while this position is secured even when the vessels are removed for cleaning and placed back afterwards. The access points for sampling as well as the openings for the tools are contained in an auxiliary, low evaporation, vessel cover. Lift Mechanism The upper drive is motorized and electronically controlled it offers eight programmable positions: an upper cleaning position and lower working positions are programmable depending on the type of stirring tool used. The upper position offers ideal access to the stirring tools and vessels for a change of tools and cleaning steps between the dissolution tests. The rigid design of the electronically driven lift mechanism ensures that the whole lift drive mechanism is positioned in a way so that the tool shafts are always kept parallel and at a 90 angle to the vessel walls when in the working position. Heating System The ultra-fast heating system is installed on an easy to remove platform within the stainless steel housing. The heat up time of the water bath has been reduced by approx. 40% compared to previous models. Access to pump, heater and all safety sensor system is possible without to move the bath from its qualified position. The connections between the heater and the bath are made by "quick connect fittings" for easy connection and disconnection. Water is pumped through the system using a powerful, yet quiet, circulation pump. The pump itself is spring mounted (to limit vibration transmission) and the flow-through heater is protected from overloading (overheating in case of control electronics failure) via a thermal fuse as well as a thermo switch for added security. With service and maintenance in mind, access to the compact pump and heater section is easily achieved without having to move the main body of the instrument. Version 2.0 2 of 8

Automation Capabilities Water Bath The motorized EPE-620 sampling system lowers the sampling probes into the media and after sampling raises them back out again. 8 different sampling positions can be programmed. The ITM-620 individual media temperature monitoring system is attached to the EPE-620 and will read and report the vessel media temperatures while sampling. The manual TM-620 or motorized TMA-620 tablet dropping magazine completes the set of useful accessories for automation. It covers all vessels and ensures low evaporation rates during the dissolution test. The magazines include magnetic holders for the tube cleaning device. The U-shaped water bath rests on vibration absorbers to avoid any vibration transfer from either inside the instrument or even from external equipment placed on the same bench surface, to satisfy the requirements from USP <711>. The bath cover can also be easily unscrewed for cleaning. The water bath contains a water diffuser for faster heating and to ensure that heated water is evenly distributed throughout the whole bath. A tap allows emptying the bath if this is required. Offline Sampling and Sample Preparation For offline automation with fraction collection the PTFC-2/8 fraction collector as well as either a PT-SP8 multiple syringe pump, an IPC peristaltic pump, or a CAT piston pump can be added to the PTWS 620. Using the PTWS 620 within an automated system offers the operator full access to the vessels before and at the end of a run as the complete drive head is lifted electronically. Sampling sequence timing is programmed using the menu system of the PTWS 620 instrument, while sampling volume and the optional media refilling process is programmed at either the PTFC-2/8 or DSR-M. No external Software No external software is necessary in this system. The motorized sampling system EPE-620 is used to lower the sampling probes while sampling into the dissolution vessels. When sampling is finished the sampling probes are raised out of the media and the system waits for the next cycle. Each sampling probe holds a PP sinter filter (usually 5 or 10µ). When the tablets have been dropped into the dissolution vessels the automated sampling process starts. If the refilling option is used media refilling will start automatically after a sample has been withdrawn. It is also possible to use the DSR-M dissolution sampling robot which features the capability of sample dilution and media refilling. The DSR-M offers excellent sampling and refilling accuracy via the fully integrated valve-less piston pump module. Sampling time and interval control is programed the PTWS 620 while volume, dilution ratio and refilling option are set at the DSR-M instrument. Version 2.0 3 of 8

Closed Loop Online Systems For an online automated system it is possible to use a UV/VIS spectrophotometer with a multiple-cell-changer. The spectrophotometer and pump of such a system is controlled by the powerful WinDiss ARGUS dissolution software. WinDiss ARGUS features drivers for most commonly available UV/VIS spectrometer types, like Agilent 8453 Diode Array, or conventional UV/VIS monochromatic spectrophotometers (preferably double beam and scanning versions) such as the T70, Analytic Jena Specord SP 200, Cecil CE and Perkin Elmer Lambda series as well as drivers for many popular types of pumps. Version 2.0 4 of 8

Advantages Some of the highlights the PTWS 620 offers are:» 6 front line vessels for easy access in manual operation and optimal visibility» Rigid aluminum water bath cover» Individual 3-point vessel centering» Excellent access to all vessels» Staggered start feature for convenient manual sampling» Screen saver functionality offers most important information at a glance (stirrer speed, bath temperature, time to next sampling interval, elapsed time, media temperature etc.)» Wake up functionality to start heating at a pre-programmed time» Programmable infinity test» MonoShaft system to avoid re-adjustment of immersion depth» Ultra-fast heating system with excellent temperature stability due to newly designed heat exchanger» Water diffuser for even temperature distribution» Vibration absorber to avoid vibration transfer into the USP/EP vessels» Spring loaded pump assembly to eliminate vibration transfer to the frame work» Extraordinary safety features for pump and heating system, flow control, digital temperature control, water level sensor, thermo switch, thermo fuse» DQ/QC, IQ and OQ documents included free of charge Features The main features of the PTWS 620 are:» Fully USP <711/724> and EP <2.9.3/4> compliant» 8 stirred positions in a 6 + 2 arrangement» Rigid motorized lift drive to raise and lower the head» Individually coded Borosilicate vessels» File up a nearly unlimited number of different test descriptions (methods)» Instrument suitability check prior to start of a test run» Staggered start capability» Vessel low evaporation sealing covers» Drainage tap to empty the bath» CFR compliant method management and user administration with access control» Built-in thermo printer to print a test-log at the end of a run» Optical and acoustic signals to inform about sampling intervals, timer count down function» Status bar with traffic light information on display shows the instrument status by different colors (green = ready to use, yellow = preparing to use, red = error encountered)» OQ, PQ interval warning with programmable interval» Interfaces: USB port for remote control of the PTWS 620, RS-232 port to connect serial devices, I/O port for remote control of external instruments in automated applications, like DSR-M, pumps and PTFC-2/8» Calibration menu for stirrer speed, bath temperature Version 2.0 5 of 8

Standard Scope of Supply The PTWS 620 comes ready to use with the following standard scope of supply:» One set of stainless steel paddles» One set of batch coded 1000ml Borosilicate glass vessels» One set of depth adjustment balls» One bottle of ALGEX water preservative» Comprehensive documentation folder including: User manual DQ/QC instrument compliance test certificate IQ documentation OQ documentation Instrument logbook Compliance certificates for vessels and stirring tools Options In addition to the standard scope of supply Pharma Test offers a broad range of accessories and options including:» Direct control of peripheral instruments via I/O port such as PTFC-2/8 fraction collector or DSR-M Sampling Robot» Eco saving double walled vacuum molded water bath» 2 liter vessel version (can also be used with 1 liter vessels)» 250 ml Mini Vessel set incl. mini paddle stirrers» Amber colored vessels for UV sensitive test materials» Full range of MonoShaft stirring tools available» Full range of certified validation tools available» PT-RP80 serial report printer Version 2.0 6 of 8

Example Runtime Report PTWS 620 features a built-in thermo printer for result reporting: RUN TIME REPORT PTWS 620 SN: 20680 V: 1.00 Print Date / Time 15/09/15 15:13:02 USER NAME: Pharma Test METHOD NAME: ptag BATCH: 1a BATH TEMP NOM.: 37.0 BATH TEMP ACT.: 36.9 LIFT POS: USP 1+2 DURATION: 0:10 SPEED NOM1: 50 SPEED 1: 50 I.-REPEAT1: 1 I.-DELAY1: 0:1 I.-REPEAT2: 1 I.-DELAY2: 0:2 TEST STATUS: NO ERRORS START: 15/09/15 15:05 END: 15/09/15 15:08:32 INT 1: 1/1 15/09/15 15:06:32 BATH TEMP ACT: 37.0 SPEED ACT1: 50 INT 2: 1/1 15/09/15 15:08:32 BATH TEMP ACT: 37.1 SPEED ACT1: 50 Type of the instrument (PTWS 620) Serial number of the instrument Firmware version installed on the instrument Date and time of this print out Name of the user currently logged in Name of the product used for this test Name of the method used for this test Batch number entered at the start of this test Nominal bath temperature from the method for this test Actual bath temperature at time of the print out Name of the lift position from the method for this test Total duration time setting for the method for this test Nominal speed setting from the method for this test First interval number of iterations First interval delay Second interval number of iterations Second interval delay Current status of the test, if test is still running it will be IN PROGRESS Start date and time of the test End date and time of the test (if already finished) Occurrence of first interval Date and time of first interval Actual bath temperature and stirring speed when first interval occurred... OPERATOR NAME Occurrence of second interval Date and time of second interval Actual bath temperature and stirring when second interval occurred If no intervals have yet occurred it will be NO INT... SIGNATURE Space to write down name of the operator Space for the operator s signature Version 2.0 7 of 8

Technical Specifications Parameter Specification Display Data Entry Acoustic Signal Timer Stirrer Position Testing Method Descriptions User Access Control OQ, PQ control Printer Number of Stirred Vessels Standard Vessels Speed Control 6"- 320*240 pixel color LCD, illuminated Resistive touch screen, alpha-numerical and functional keys Acoustic signal for operator information at programmable intervals Programmable sampling times, wake-up and sleeping mode, operation time information and timer count-down mode 8 freely programmable stirrer immersion positions (paddle over disk, transdermal cylinder etc.) Unlimited number of test descriptions can be stored on SD card Multiple level access control Programmable time periods to remind about QO or PQ testing Built-in thermo printer 8 (6 + 2 arrangement) 1 liter USP/EP Borosilicate glass vessel, each individually coded 25-250 RPM Speed Accuracy ±2% of set speed, typically < 1% Stirrer Shaft Wobble Better than 0.2 mm total run out System Tools MonoShaft stirrer design, USP/EP apparatus 1, 2, 5, 6 tool adapter, cream cell, transdermal patch tools, tools & vessels individually coded Heating System Pump for water circulation and 1400W heater for fast heating up Heater Range 25-45 C Heater Accuracy ± 0.2 C inside the water bath Heat Up Process Energy saving, programmable wake up function and sleep mode Water Circulation Water circulated from external heating system through special diffuser inside the water bath Vibration Elimination Water bath rests on vibration absorbers, spring loaded pump assembly Calibration Built-in calibration procedures for speed, temperature control, OQ/PQ interval programmable including alarm indicator Bench Space Requirements Approx. 112 x 58 cm Packaging Approx. 137 x 78 x 87 cm (W x D x H) Weight 75 kg net weight, 100 kg gross weight Certification All components certified to USP / EP requirements We reserve the right to make technical changes without any prior notice. Version 2.0 8 of 8