FLAMEBREAK. Rev.D Mechanical Performances - General: TM

Similar documents
Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Guide to interpreting Markings for Single Axis Fire Doors Hinges

Contents EN :2006+A2:2016 (E)

Loss Prevention Standard

Regulatory Reform (Fire Safety) Order 2005

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Best practice guide. Door coordinator devices to BS EN in association with. Association of Building Hardware Manufacturers

Section 2 - Applications - General. Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Mechanically operated locks and locking plates

Panic and Emergency Exit Devices

25 th November Title:

DATA CENTRES & IT SECURITY. High security solutions

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Transport Vertcial Market Our Ref: ABC123

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

Best practice guide. Electrically powered hold-open devices to BS EN in association with. Association of Building Hardware Manufacturers

A Guide to the Selection of Smoke Seals for Doorsets. Information Sheet No. 5. Intumescent Fire Seals Association

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

Meeting the requirements of the Equality Act & Fire regulations. Which Door Control?

High Security Locking. Product Catalogue

Strebord 35 FD30 Strebord 44 FD30 Strebord 54 FD60

Electromagnetic Locking Devices Performance Requirements

Schueco Fire and Smoke Protection Systems

Panic & emergency exit devices. CFPA-E Guideline No 2:2013 F

Timber Doorsets For Every Application. ASSA ABLOY, the global leader in door opening solutions

Reference F-IAB-012 Page Page 1 of 6 Revision 2. Please complete all sections and submit electronically to

Updated to. include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations

Market Introduction DORMA. Modular Panic Hardware System PHA 2000 / PHB 3000

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

Panic & Emergency Exit Hardware

Controlled Door Closing Devices

AX-S Steel Fabricated Covers

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Annex of the certificate (Page 1/7) Accreditation Scope

Specifying Security Hardware for Doors

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Education Vertcial Market Our Ref: ABC123

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Healthcare Vertcial Market Our Ref: ABC123

GUIDELINIE ECB S R10. March European Certification Body GmbH

fire resistance testing

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Commercial Vertcial Market Our Ref: ABC123

Public and Government Buildings

ABLOY EFEND. New name for security

Hardware Selection Process

HIGH SECURITY VAULT DOORS. A complete line of high security attack-resistant vault doors and accessories. AN ISO 9001 CERTIFIED COMPANY

ARCHITECTURAL HARDWARE

General test 74 Thermal properties 75 Fire windows 75 Sound reduction 76 Safety 76 CWCT accreditation 77 Resistance to forced entry (SBD) 78

HD72 Euro Profile Mortice Lockcase. The high performance lock that goes beyond the standard. ASSA ABLOY, the global leader in door opening solutions

Uniclass L4181 EPIC D181. CI/ SfB (31.5) X. Orbis Classic Range

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Security. ModuSec. Introduction... 1 Walls... 2 Doors... 3 Locks... 5 Windows... 6

Perimeter Security. Gates and fences are the first signs of a secure home and act as a good deterrent to intruders. Make sure they are in good repair.

CERTIFICATE OF APPROVAL No CF 5657 UNION ARCHITECTURAL HARDWARE

CERTIFICATE OF APPROVAL No CF 418 PROMAT UK LTD

Performance Doorsets. Martin Roberts

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

Rim Locks. Rim Locks Index. Standards & Approvals. Keying Groups. Keys

SECTION HARDWARE

Product Guide. The highest possible standards. The best possible solutions. Manufactured in the UK. Cert No 5893 ISO 9001

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Hospitality Vertcial Market Our Ref: ABC123

Designed to provide immediate escape, first time, every time

Panic & emergency exit devices

Introduction of MSBC Secure India Pvt Ltd. Manufacturer & Installer of Fire Resistance Timber Doorsets

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

WDC SERVICE SOLUTIONS LTD

CERTIFICATE OF APPROVAL No CF 520 ASSA ABLOY LTD T/A ASSA ABLOY SECURITY DOORS

Fire Door Maintenance Guide.

UK Product Guide. Fire Doors.

ABLOY DOOR CLOSERS Excatly the right choice

SKG-IKOB Certificatie B.V. Trading under the names SKG, IKOB-BKB and SKW Certificatie

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

CERTIFICATE OF APPROVAL No CF 5118 ASSA ABLOY LTD

Concealed Door Closers

INFORMATIONAL PUBLICATION SECURITY VS. EXITING... Door Locking Hardware in Schools

The global leader in door opening solutions

PERFORMANCE & TESTING

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges

Code of Practice: Hardware for Fire and Escape Doors. Issue No.2 June 2006 THE GUILD OF ARCHITECTURAL IRONMONGERS

For more information on Abloy UK visit EXIT HARDWARE

METRO BASIN MONO MIXER CHR

Electromagnetic Locking Devices

Fire Door Closing Systems

Fire and Security Products and Services

Newstar Locks. NEWSTAR form and function for life. BS Range. London Fire Brigade Range

Fire Protection. Intumescent fire and smoke seals for door assemblies

ASSA Lockcases. ASSA ABLOY, the global leader in door opening solutions

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007

2.2 Factors in design

Ironmongery Performance Specifications

BRISTOL: A History & Future.

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

Fire and Smoke Door Inspections Qualified Training 02/03/17

Product. Regulations. Agrément Certificate No 92/2841 Third issue* Designated by Government to issue European Technical Approvals

CERTIFICATE OF APPROVAL No CF 810 HOPPE (UK) LIMITED

HOME SECURITY. 2 - Basic security

TTOWNHOUSE SASH WINDOW SASH WINDOW

CERBERUS DOORS E V E R Y PA R A D I S E N E E D S A H E L L O F A D O O R! 1

Transcription:

FLAMEBREAK Mechanical Performances 1 Mechanical Performances - General: NOTE: Doorsets using FLAMEBREAK based doors have been tested to performances that exceed the DD171 / BS EN 1192 minimum requirements for Severe Duty applications. (See page 2): When considering doorsets for public buildings or dwellings there is a tendency to concentrate on a Test Report Ref: Chilt/P10056/02 June 2010: particular secondary performance e.g. fire Test BS EN 947 - Severe Duty requirement = 1000N - performance, acoustic properties etc. This can tested to 1250N. lead to an oversight of the basic function of a doorset which is to provide a means for traffic to Test BS EN 948 - Severe Duty requirement = 350N - tested pass from one side of a wall to the other. to 438N. To perform satisfactorily and to provide for other Test DD717 Test Ref: 4.3 - Severe Duty requirement = 150 performances, the doorset must work reliably over a Impacts - tested to 200 Impacts. long period of time and often under conditions Test DD717 Test Ref: 4.9 - Severe Duty requirement = where the doorsets are subjected to abuse. If the 200N. - tested to 300N. door does not operate properly then all of the other performances that might otherwise be attributed to Test DD717 Test Ref: 4.10 - Severe Duty requirement = the particular location are likely to be undermined. 200 Impacts - tested to 300 Impacts. The term Mechanical Performance is used in this section to identify a wide range of doorset loading PAS23: and durability testing that my be specified in general For dwellings, specifications may call for PAS 23 or specific terms to suit the requirements of a related test data. PAS23 General performance particular project including requirements for requirements for door assemblies - Part 1: Single leaf, security doors. external door assemblies to dwellings requires mechanical testing similar to the DD171 tests but is It is important to appreciate that tests of this nature extended to include Cyclic, Air Permeability, apply to the doorset as a whole and in some cases Watertightness and Wind Resistance testing. the testing is specific to a particular design including NOTE: Cyclic testing may be specified separately by all related hardware and glazing. reference to BS EN 1191 with classifications defined by reference to BS EN 12400. Pacific Rim Wood UK Ltd. have carried out numerous tests with various partners where the PAS24: FLAMEBREAK door core was used as the basic PAS24 Enhanced security performance requirements door leaf construction. This evidences provides for door assemblies - Part 1: Single and double leaf, confidence with regard to the potential performance hinged external door assemblies to dwellings. This is a of the FLAMEBREAK core. security doorset standard that is supported by ACPO (Association of Chief Police Officers) under the DD171: Secure by Design initiative. Strength and durability testing for doorsets is defined by reference to DD171 - Guide to LPS (Loss Prevention Standard): specifying performance requirements for hinged or Specifications may require doorset designs to satisfy pivoted doors (including test methods). LPS ratings with the tested doorsets approved by the Loss Prevention Certification Board. More recently, European standards have been (See page 5). introduced to replace some of the tests described in DD171. (See page 2). BS EN 1627 ~ 1630: European test and classification standards similar to The testing of doorsets using FLAMEBREAK door LPS requirements are currently being developed. cores has been carried out by Chiltern Dynamics using all of the DD171 tests but substituting the NOTE: Test standards for security doorsets e.g. PAS24, LPS 1175 & EN 1627 ~ 1630 tests are essentially reactive particular DD171 tests with the alternative EN test standards. i.e. The test methods include manual attack where applicable. For the European tests, BS EN elements that are constantly being amended as villains 947 ~ 950 describe the test methods with discover new and more sophisticated ways to overcome classifications defined by reference to BS EN 1192. security design elements. Specifications for doorsets of this type should include required test standard revision references.

2 DD171 Mechanical Performance DD171 & BS EN 1192 Mechanical Testing: Strength and durability testing for doorsets is defined by reference to DD171 - Guide to specifying performance requirements for hinged or pivoted doors (including test methods). British Standard Draft for Development DD171 : 1987 provides a means for the testing of complete doorsets that are subjected to various levels of abuse to allow for the evaluation of mechanical performances. More recently, European tests have been adopted that replace some of the mechanical tests described by reference to DD171. Where this has occurred, the EN tests are used but the DD171 tests have been retained in the United Kingdom where these have not been substituted by the European standards. The following guidance is given to explain the grading system used by reference to DD171 for determining mechanical performance properties: LD = Light Duty : Low frequency use by those with a high incentive to exercise care. e.g. by private house owners - small risk of accident occurring or abusive use. MD = Medium Duty : medium frequency use primarily by those with some incentive to exercise care - some chance of accident occurring or mild abuse. FLAMEBREAK HD = Heavy Duty : High frequency use by public and others with little incentive to exercise care. Risk of accident with probability of some abuse. e.g. offices, particularly offices open to the public. Doorsets based upon the use of FLAMEBREAK door cores have been successfully tested with testing extended to exceed the minimum requirements of D171 and BS EN 1192 for Severe Duty performances. SD = Severe Duty : High frequency use with risk of accidental damage and possibility of violent abusive usage. e.g. Hospitals, Educational Establishments. Comparisons of DD171 & BS EN 1192 Mechanical Tests.

FLAMEBREAK PAS23 & PAS24: Doorsets manufactured using FLAMEBREAK cores have been successfully tested to meet PAS 23-1 : 1999 and PAS 24-1: 1999 performances requirements, thus demonstrating the potential of FLAMEBREAK door cores to provide for the general performance requirements and enhanced security performances for external door assemblies to dwellings. PAS23 & PAS24 3 PAS 23 (Product Assessment Specification - General Performance Requirements) provides for a number of durability and mechanical tests, similar in many respects to DD171 including tests for: Resistance to static torsion. Operating forces. Resistance to vertical loads. Slamming resistance. Closure against obstructions. Abusive forces on handles. Resistance to soft & heavy body impact. Resistance to hard body impact. Resistance to thermal variation. Resistance to humidity. In addition to the above, PAS 23 requires testing for weather tightness and a cycling test (50,000 cycles) that must be achieved without detriment to the operation of the doorset. PAS 24 (Product Assessment Specification - Enhanced Security Performance) provides for testing of doorsets in respect of resistance to opportunists attacks. This standard is supported by the Association of Chief Police Officers and forms a core element of the Secure by Design initiative that is promoted by many Local Authorities. It is important to recognise that PAS 23 and PAS 24 testing is related to a prescribed doorset complete with all glazing, seals and hardware. Any variation to size, detail or fittings will generally require retesting. However, the specimens that achieved satisfactory PAS 23, PAS 24 performances were based upon the use of the FLAMEBREAK 430 and FF930 cores, it has therefore been possible to assess other FLAMEBREAK door core types as providing for suitable alternative core constructions, without adversely affecting the performance of a doorset that otherwise conforms with the tested details. See Chiltern Dynamics Assessment Ref: Chilt/P06015 February 2006 NOTE: PAS23 Clause 6.2 Weathertightness test data applies to plywood faced FLAMEBREAK products only. i.e. Types 430, 630 & 660. MDF versions FLAMEBREAK FF630 & FF660 should not be used in external locations.

4 LPS Ratings LPS Security ratings: Some specifications may call for security doorset performances to meet LPS rating requirements. Otherwise, private specifications may use the LPCB approved methods as a basis for determining FLAMEBREAK test methods with modifications to meet specific risks identified by the Client and related to particular project considerations. This testing essentially relates to prescribed doorset designs including hardware.

FLAMEBREAK Security Doorset Considerations 5 Each doorset manufacturer will have their own preferences with regard to the construction of doorsets intended for DD171 severe duty or security doorset applications. Notwithstanding the performance achieved by testing, the following is provided by way of guidance for consideration where additional reinforcement might be required to suit doorsets in locations that might be vulnerable to heavy impact attack. Concealed rod type Flush bolt. Fig. 11.2 The use of concealed rod type flush bolts provides for improved resistance to splitting when doors are subjected to impact forces. Hardware Enhanced fixing: Hinges & Hanging Devices: Whereas successful testing has been carried out using wood screws, the use of minimum11/2in. No. 10 fully threaded twinfast or chipboard screws is recommended for the fixing of load bearing items of hardware to FLAMEBREAK door constructions. In any event, pilot holes should be drilled to receive screw fixings in both the door leaf and the frame. Locks / Latches: Under heavy and abusive impact all wood door constructions may split at the lock / latch positions. The use of backplates with bolt through fixings. (e.g. ASSA 6650 leversets & ASSA 320 / 330 cylinder roses) is recommended to strengthen doors at these positions. Recommended Lock / Latch fitting. Fig. 11.1 The use of backplates with bolt through fixings provide a means for clamping the door at lock / latch positions to improve resistance to splitting. Other Hardware: Surface mounted hardware such as kick & buffer plates can generally be used without detriment to mechanical performance. NOTE: The use of PVC protection plates is recommended in preference to metal plates. Sharp edges can be created when using metal plates, (particularly aluminium) resulting from impact damage with a consequent risk to users of a building. Lever Handle Spindle It is recommended that pull handles should be of the bolt-through type used in conjunction with load spreading washers on the bolted face with pull handle fixings covered by a finger plate. Cover plate Backplate Bolt thro fixing Backplate Cover plate Surface mounted Emergency Exit & Panic devices and surface mounted barrel bolts (e.g. Versabolt IR Laidlaw Ref. 34 008) can generally be used without weakening the door construction. Cylinder Bolt thro fixing Edge fixed flush bolts can weaken the door construction in a similar manner to locks and latches. Use of concealed rod type edge fixed flush bolts (e.g. John Planck Ltd. Ref. RB-001 or 001R) is recommended as a preferred alternative to edge fixed flush bolts for mechanical strength purposes.