LDM-519-DIM LHDC MONITOR Digital Line Heat Detector Interface

Similar documents
Linear Heat Detection Cable - Monitor

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

DICTATOR Hold-Open Systems for Hazardous Areas

ALARMLINE ANALOGUE Linear Heat Detection System

Model 5610 Infra-red Transit Heat Sensor

SET Installation and Operating Instructions. Level switch for one sensor

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

An introduction to... Sigma

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

DB5 Intrinsically Safe Sounder Type DB-5

INPUT / OUTPUT MINI MODULES

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Interface Modules for SENTRI

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Crowcon Gasmaster. 1 to 4 channel gas detection control panel. Installation, Operation and Maintenance Manual

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Intrinsic Safety Solenoid Valves :-

OilSET-1000 (12 VDC)

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

SET-2000 Hi Level/Oil

STOCKIST OF LINEAR HEAT SESNING CABLE in INDIA

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

MBCE-110/230FR Flame Sensor Module

IECEx Certificate of Conformity

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

Intrinsically Safe Flame Detector Installation Guide

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

Application, Installation, Operation & Maintenance Manual

Hazardous Area Zirconia Oxygen Systems

SOUNDER CONTROL MODULE SCM-AS4

Environmental Monitoring & Control Units Types MCU 3 & 4 Installation and Hardware

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

Excellence in Level Measurement

Commercial and Light Industrial Fire Alarm Control Panel

0 A EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS

SET-2000 Oil/Sludge 12 VDC

Fire Alarm System Accessories

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Software Version 2.01 LEVEL MONITOR MODEL 220

MD12-1 Vehicle Loop Detector

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

Approved by: Document no.: EGT

IGD.CO.UK

APPLICATION DATA SHEET

MBCE-110/230FR Flame Sensor Module

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

MD12-2 Vehicle Loop Detector

Power Supply Display Module PSDM. Installation and Operation Manual

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

Gasmonitor+ Installation, Operation and Maintenance Manual

Excel-EN Conventional Fire Control Panel

TXgard-Plus. Flameproof Toxic and Oxygen Gas Detector with Non-intrusive One-man Calibration. Installation, Operation and Maintenance Instructions

Instrumentation Products and Applications

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

INSTRUCTION MANUAL (ATEX)

MBCE-110/230UV Flame Sensor Module

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

OPERATION AND INSTALLATION MANUAL

BX444-Mc Gas Detector

Axiom Technologies L.L.C Telephone: Pennbright Dr., Suite 220 Fax: XP7 USER S MANUAL

MMG Gas burner safety control

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

EXTINGUISHING AGENT RELEASE MODULE

REGARD GAS DETECTION SYSTEM

LAE10 LFE10. Use. Series 02

DCS-100. intelligent damper control & monitoring system

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

Intelligent Security & Fire Ltd

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

XP95 Intrinsically Safe Product Guide MAN 3054

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Intelligent Security & Fire Ltd

Technical Manual. Level Alarm Unit CARLA & WIDS

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

Intrinsically Safe Solutions

SIL725 Safety Annunciator

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

Installation and application. Leakage detectors, CLS/FLS/FLS10/MiniCAS II

Flame Safeguards LFE10. Building Technologies HVAC Products

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Addressable Loop Modules

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

4) Intrinsic Safety Certification

Conventional & Twin-wire Fire System

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

DC1192 Input /Output module

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

General Routing Interface

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

Transcription:

LDM59DIM LHDC MONITOR The module is designed to monitor a length of Digital Linear Heat Detecting Cable (LHDC) for both Fire condition, and Fault status (open circuit). Digital LHDC may be employed in lengths up to 5Km. Signalling of fire and fault status by means of volt free contacts. The units has open collector type solid state outputs for local indicators. The DIN rail modular form of the unit enables it to both be provided in a variety of discrete housings and readily integrated into multi zone control panels. The primary features of the control units are: LHDC Hazardous rea use by means of Intrinsically Safe Zener arrier. Fault monitoring of LHDC for open circuit conditions. LED indication of Fire, Fault & Supply status. Integral Test & pushbuttons. Volt free contact outputs for Fire & Fault conditions. Indicator and control switch connections for local fascia implementation DIN Rail mounting. LDM59DIM Data Sheet D55 Issue 6 May 0 Page of 5

LDM59DIM LHDC MONITOR Principles The unit is operated in conjunction with a length of Digital Line Heat Detector Cable (LHDC) and an end of line () terminator. The LHDC is a twisted pair twin core cable. When the trigger temperature of the LHDC is reached these cores connect and a Fire larm is registered. The LDM59DIM module monitors the LHDC. Reference should be made to the (separate) data sheet on the Line Heat Detectors for specification of their performance. There are three principle modes of supply & signalling operation : Figure shows a typical system where the LHDC is connected via a junction box & interposing cable. The repeat contacts may be employed to signal an alarm panel and/or initiate control systems. LINE HET DETECTOR TERMINTOR FIGURE J INTERPOSING CLE LDM59DIM REPET CONTCTS ( Sets) REPET CONTCTS Vdc Figure shows an arrangement for a Hazardous rea employing an intrinsically safe zener barrier. LINE HET DETECTOR J IS RRIER LDM59DIM REPET SIGNLS FIGURE HZRDOUS RE SFE RE Vdc Module rrangement 7 58 5 6 7 8 9 0 LEDs 90 PTOL LDM59DIM RESET Pushuttons 5 6 7 8 9 0 FIGURE DIN Rail 5mm Symmetrical LDM59DIM Data Sheet D55 Issue 6 May 0 Page of 5

LDM59DIM LHDC MONITOR Enclosures The unit can be mounted in a variety of enclosures including multi zone alarm panels and Explosion Proof cases. The example shown combines two zones of detection and incorporates a DIN rail mounting power supply. The case is flame resistant polystyrene, colour RL 705. Ingress protection rating is IP65. 00 00 86 86 SUP PLY SUP PLY DC LO DC ON PTOL LDM59DIM RES ET PTOL LDM59DIM RES ET Operational Specification Hinged Transparent Door 0 Vac / Vdc PSU Supply Voltage: 0 Vdc Supply Current: <**m Normal / Fault <**m larm / Fire LHDC Terminator: K End Of Line resistor. Indicators: larm : Red off Fault: Yellow off Supply: Green off Pushbuttons: larm Test Fault Test / Relay Contacts: larm changeover sets (0.5 @ 0 Vdc) Fault changeover set Lamp outputs: (O/C type) Remote Inputs: larm switch to 0V 00m Fault switch to 0V 00m Lamp Test FIGURE Connections Typical 0 Vdc 500 m FIGURE 5 K DIGITL LINE HET DETECTOR CLE 5 6 7 8 9 0 LHDC NO NC COM NO NC COM COM NC NO Remote / Fascia Indicators larm larm Fault Relay Normally DeEnergised Norm. Energised LDM59DIM DIGITL INTERFCE MODULE Flt Flt Tests Remote Indicators Remote/ Common 0V Supply V ++ Remote s s 5 6 7 8 9 0 Power Supply 0 Vdc + LDM59DIM Data Sheet D55 Issue 6 May 0 Page of 5

LDM59DIM LHDC MONITOR Hazardous reas IS arriers The LHDC may be installed in a Hazardous rea by employing an Intrinsically Safe Zener arrier which ensures that even under fault conditions the LHDC circuit has insufficient electrical energy to produce a spark initiated explosion. oth arrier and LDM59DIM module must be located in a Safe rea or Explosion Proof enclosure. Each arrier type specifies maximum parameters for cable located in the Hazardous rea. These parameters are: Capacitance (C), Inductance (L) & Inductance to Resistance Ratio (L/R). The whole of the hazardous area circuit, both LHDC and interposing cable, must comply in all three aspects. For use with the LDM59DIM Patol recommends a Dual Channel Shunt Diode C arrier, 5V 50m R per channel. MTL 7765 by Measurement Technologies Ltd. is of this type. The CLL/R parameters for the barrier depend on the configuration and gas group. When considered together with the LHDC & interposing cable specification they will determine the compliance of an installation and/or define maximum cable lengths. COMINED CHNNEL CONFIGURTION Whilst the supply 0V must be maintained within V of earth, by employing both channels of the barrier (Figures 7 & 8) the circuit is isolated from earth at the IS arrier, thus obviating multiple earth points on Fire Panel signalling systems such as addressable loops. HZRDOUS RE SFE RE IS RRIER C L L/R to be considered for arrier / Gas Group (MTL7765) Linear Heat Detector Cable CH CH INTERFCE / LDM59DDL FIRE PNEL Trigger 0 Circuit 9 + _ C + C = C to be considered for arrier / Gas Group L + L = L to be considered for arrier / Gas Group IS ERTH Greater of L/R L/R to be considered for arrier / Gas Group C L L/R C L L/R JUNCTION IS RRIER OX (MTL7765) Linear Heat Detector Interposing CH CH FIGURE 6 INTERFCE / LDM59DDL FIRE PNEL Trigger 0 + Circuit 9 _ IS ERTH FIGURE 7 EXMPLE : The parameters for the MTL7765 in a combined channel configuration (Figs 6 & 7) for a group IIC gas are : Maximum Capacitance C=0.58uF Maximum Inductance L=0.mH Maximum Inductance to Resistance Ratio L/R=uH/ohm. Patol 70deg. Nonrmoured LHDC has C=0pF/m, L=0.95uH/m, L/R=5.5uH/ohm. With no interposing cable the predominating factor in this case is inductance which limits the LHDC length to 6m (0. / 0.00095). SINGLE CHNNEL CONFIGURTION nother arrangement is a single channel circuit which permits greater lengths of LHDC to be installed. HZRDOUS RE SFE RE IS RRIER C L L/R to be considered for arrier / Gas Group (MTL775) Linear Heat Detector Cable CH CH LDM59DIM Supply 0 Circuit 9 POWER + _ Vdc FIGURE 9 LDM59DIM Data Sheet D55 Issue 6 May 0 Page of 5

LDM59DIM LHDC MONITOR The configuration of fig.8 shows one side of the LHDC circuit returned to earth. EXMPLE : The max parameters for the MTL775 for a group IIC gas are : Maximum Capacitance C=0.58uF Maximum Inductance L=.5mH Maximum Inductance to Resistance Ratio L/R=66uH/ohm. Patol 70deg. Nonrmoured LHDC has C=0pF/m, L=0.95uH/m, L/R=5.5uH/ohm. With no interposing cable the predominating factor in this case is inductance which limits the LHDC length to 56m (.5 / 0.00095). For further information including the full range of Patol Linear Detector CLL/R specifications refer: D0 PPLICTION NOTE LINER HET DETECTION CLE The use of LHDC in Hazardous reas by means of Intrinsically Safe arriers The above information is a guidance note. National / Local Regulations, Standards and arrier Specifications MUST take precedence in any system design and implementation. Operation NORML RESET LMP LHDC & Supply Voltage Normal Green Supply LED larm & Fault LEDs Off larm & Fault Indicator outputs Off & larm relays Deenergised Fault relay Energised (Not Fault / OK output On) LHDC open circuit Yellow Fault LED On Fault Indicator output On (Not Fault / OK output Off) Fault relay Deenergised The unit will automatically return to Normal on rectification of the Fault condition. LHDC ctivated (S/C due to Fire) Red larm LEDs On larm Indicator outputs & On larm relays & & Energised Module Fire Test pushbutton operated LEDs, fire relays and indicator outputs as for Fire above. Module Fault Test & pushbutton operated OR input activated. The unit is normalised after a Fire Test pushbutton operation. n LHDC Fault condition is simulated during P operation fter a true Fire operated LHDC requires replacement before. Remote Lamp Test input activated larm & Fault Indicator outputs On Rectory Road, Padworth Common, erkshire, United Kingdom. RG7 JD Tel: + (0) 8 97070 email : info@patol.co.uk Fax: + (0) 8 970700 Web: www.patol.co.uk LDM59DIM Data Sheet D55 Issue 6 May 0 Page 5 of 5