PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

Similar documents
ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

PRODUCT SPECIFICATIONS

Commercial High-Efficiency Condensing Units

PRODUCT SPECIFICATIONS

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton

Commercial High-Efficiency Condensing Units

Concealed Ducted Split Series R-407C MBH

PACKAGE AIR CONDITIONER

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

PAR5. Product Specifications

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

PAJ3. Product Specifications

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

13 SEER CONDENSING UNITS

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Product Data. Fig. 1 - Unit 50VR -A

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

MBR. Multi-Position. Modular Blower

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

Product Data. Fig. 1 - Unit 50EZ -A

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

PRODUCT SPECIFICATIONS

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

16 SEER TWO-STAGE AIR CONDITIONERS

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features

Unit Features & Benefits RQPM/RQRM Series

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Product Data. Fig. 1 - Unit 50VG -A

Model 655A Sizes

RGE 13 A T - 1 A

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

HORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h

50TM TFF COMBINATION HEATING/COOLING UNITS

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

GENERAL ELECTRIC VERTICAL PACKAGED UNITS

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

Wall Mounted Air Conditioners with Gas Heat Models AVGA

50TM COMBINATION HEATING/COOLING UNITS

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

R4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

AVPTC. Air Handlers 1½ to 5 Tons

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

WCH5**4. Product Specifications

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

High Heat COP. High/Low Stage

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

13 GEP A L P - 1 A

VariCool VAV Engineering Guide

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Ruud Commercial Achiever Series Package Gas Electric Unit

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

TECHNICAL SPECIFICATIONS

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

Advance Release September 2009

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

AVPTC Multi-Position, Internal Txv

Transcription:

PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed for side-by-side and ground-level or rooftop applications. Standard Features Two-speed evaporator blower motor; low-speed for low-static applications, high-speed for high-static applications Quiet operating top condenser discharge Copper tubes/aluminum fin coils Hermetically sealed reciprocating compressor with internal relief valve and internal overload protection Fully charged R-22 system Liquid line filter drier High-efficiency performance Bottom pan rails elevate unit above slab High-pressure manual reset control ly enclosed, permanently lubricated condenser fan motor Both condenser fan and evaporative blower motors are provided with internal thermal overload protection Third-Party Tested Independent third party performance tested by ETL Testing Laboratories, Inc. Per ARI Standard 210-240 Cabinet Construction Heavy-gauge, G-90 galvanized steel with removable access panels Completely weatherized, properly reinforced and braced Steel sheet metal is zinc-coated and galvanized by the hot-dip process Fully insulated air handling compartment Convenient access panels Accessories Heat Kit with plug-in connection (nominal capacity from 12-15 kw) Room Thermostat (CHT18-60) Outdoor Thermostat (OT18-60) Thermostat (CHT18-60HD) Accessories (Field Supplied) Roof Curb Downflow Plenum (includes filter rack) Manual Freash Air Damper (to be used with Downflow Plenum) Economizer (to be used with Downflow Plenum) Accessory Heat Kit Features Primary limit protection Rust-resistant nickel Chromium heating elements (see Electrical Data Chart) SS-199D www.goodmanmfg.com 02/04

Specifications PC048-5A 2 PC060-5A Cooling Capacity BTUH [KW] 42,200 [12.4] 50,300 [14.7] ible Cooling Capacity BTUH [KW] 29,800 [8.7] 32,200 [9.4] EER 9.63 8.15 Sound Rating (bels) 8.4 8.4 Indoor Blower Type DD DD Size -D x W in [cm] 9 x 8 [22.9 x 20.3] 10 x 8 [25.4 x 20.3] Motor H.P. [KW] 1/2 3/4 Evaporator Coil Face Area ft 2 [m²] 6.44 [0.60] 6.22 [0.58] Fins/In FPI [Fins per cm] 15 [5.9] 12 [4.7] No. of Rows 2 3 Outdoor Fan Fan Dia. In [cm] 22 [56] 22 [56] Motor H.P. 1/4 1/4 Condenser Coil Face Area ft 2 [m²] 16.2 [1.5] 16.2 [1.5] Fins/In FPI [Fins per cm] 22 [8.7] 22 [8.7] No. of Rows 1 1 EER = Energy Efficient Ratio = Capacity (BTUH)/kW Input kw Input = Compressor + Indoor and Outdoor Blower Cooling performance based upon standard airflow CFM. Performance of units tested and verfied by ETL Testing Laboratories. Cooing Capacities is gross, which does not include the effect of teh indoor motor. Model Identification P C 0 6 0 5A * All units are direct drive (DD) Electrical Ratings *Minimum Maximum Power Supply Max Min Compressor Blower Motor Cond. Fan Motor Model Circuit Overcurrent Volts Volts Volts Ph Hz Ampacity Protection RLA LRA FLA FLA PCO48-5A 380/415 3 50 12.9 20 456 342 8.4 45 3680 1.3 355 0.6 225 PC060-5A 380/415 3 50 16.4 20 456 342 10.5 62 4955 2.2 715 0.6 215 *Wire size should be determined in accordance with Local Electrical Codes. Extensive wire runs will require larger wire sizes. Evaporator Blower Specifications Model Speed Airflow External Static Pressure In-Water [Mbar] 0.1 [0.25] 0.2 [0.5] 0.3 [0.75] 0.4 [1.0] 0.5 [1.25] PC060-5A LOW CFM [L/s] 1885 [890] 1840 [870] 1795 [850] 1675 [790] 1575 [740] HIGH CFM [L/s] 2030 [960] 1955 [920] 1900 [900] 1760 [830] 1655 [780] PC048-5A LOW CFM [L/s] 1540 [730] 1450 [680] 1315 [620] 1215 [570] 1070 [500] HIGH CFM [L/s] 1590 [750] 1490 [700] 1395 [660] 1280 [600] 1120 [530] [ ] Designates metric Electrical Designator 5-380 -415 V, 3 Ph, 50 Hz Nominal Capacity 048-42200 BTUH 060-50300 BTUH Unit Type PC - Package Cooling Unit

PC048-5A SCFM INDOOR AIR WB CONDENSER AIR TEMPERATURE (DEGREE F) 85 95 105 115 120 72 52.2 25.1 5.17 49.4 24.0 5.38 46.5 23.0 5.64 43.7 21.9 5.90 42.3 21.4 6.03 1118 67 47.5 31.3 4.80 45.1 30.3 5.07 42.3 29.2 5.33 39.5 29.2 5.59 38.1 29.2 5.72 62 43.7 37.2 4.54 42.5 36.2 4.80 41.4 35.1 5.07 39.0 33.8 5.27 37.8 33.1 5.38 57 42.3 39.7 4.44 40.4 37.9 4.70 38.1 35.8 5.01 36.2 33.8 5.22 35.3 32.7 5.33 72 54.1 27.8 5.27 51.2 26.8 5.54 48.4 26.1 5.80 45.1 24.7 6.06 43.5 24.0 6.19 1315 67 49.8 35.8 4.96 47.0 34.8 5.22 44.2 33.8 5.48 41.4 32.7 5.74 40.0 32.2 5.88 62 46.1 42.8 4.70 43.7 41.1 4.96 41.8 39.0 5.22 39.5 36.9 5.54 38.3 35.8 5.69 1512 57 45.6 43.2 4.70 43.7 41.1 4.96 41.8 39.0 5.22 39.5 36.9 5.54 38.3 35.8 5.69 72 55.5 30.3 5.38 52.6 29.2 5.64 49.4 28.2 5.90 46.5 27.5 6.16 45.1 27.1 6.29 67 51.2 40.0 5.07 48.4 39.0 5.33 45.6 37.6 5.59 42.8 36.5 5.85 41.4 36.0 5.98 62 48.9 45.6 4.91 46.1 43.5 5.17 44.2 41.4 5.43 41.4 39.0 5.74 40.0 37.8 5.90 57 48.9 45.6 4.91 46.1 43.5 5.17 44.2 41.4 5.43 41.4 39.0 5.74 40.0 37.8 5.90 ible heat capacities shown are based on 80 F DB entering air at the evaporator coil. For sensible heat capacities at other than 80 F DB, deduct 84 BTUH per 100 CFM of evaporator coil air for each degree below 80 F, or add 84 BTUH per 100 CFM of evaporator coil air per degree above 80 F. CAPACITIES AT 95 F OUTDOOR., 75 F DB AND 63 F WB INDOOR TOTAL MBTUH 39.8 SENSIBLE MBTUH 28.2 LATENT MBTUH 11.7 PC060-5A SCFM 1615 1900 2010 Indoor Air WB Condenser Air Temperature (Degree F) 85 95 105 115 120 72 64.4 31.3 6.38 60.9 30.0 6.64 57.4 28.7 6.96 53.9 27.4 7.28 52.2 26.8 7.44 67 58.6 39.2 5.93 55.7 37.8 6.25 52.2 36.5 6.57 48.7 36.5 6.90 47.0 36.5 7.06 62 53.9 46.5 5.61 52.5 45.2 5.93 51.0 43.9 6.25 48.1 42.2 6.51 46.7 41.3 6.64 57 52.2 49.6 5.48 49.9 47.4 5.80 47.0 44.8 6.19 44.7 42.2 6.44 43.5 40.9 6.57 72 66.7 34.8 6.51 63.2 33.5 6.83 59.7 32.6 7.15 55.7 30.9 7.48 53.7 30.0 7.64 67 61.5 44.8 6.12 58.0 43.5 6.44 54.5 42.2 6.77 51.0 40.9 7.09 49.3 40.2 7.25 62 56.8 53.5 5.80 53.9 51.3 6.12 51.6 48.7 6.44 48.7 46.1 6.83 47.3 44.8 7.02 57 56.3 53.9 5.80 53.9 51.3 6.12 51.6 48.7 6.44 48.7 46.1 6.83 47.3 44.8 7.02 72 68.4 37.8 6.64 65.0 36.5 6.96 60.9 35.2 7.28 57.4 34.4 7.60 55.7 33.9 7.77 67 63.2 50.0 6.25 59.7 48.7 6.57 56.3 47.0 6.90 52.8 45.7 7.22 51.0 45.0 7.38 62 60.3 57.0 6.06 56.8 54.4 6.38 54.5 51.8 6.70 51.0 48.7 7.09 49.3 47.2 7.28 57 60.3 57.0 6.06 56.8 54.4 6.38 54.5 51.8 6.70 51.0 48.7 7.09 49.3 47.2 7.28 ible heat capacities shown are based on 80 F DB entering air at the evaporator coil. For sensible heat capacities at other than 80 F DB, deduct 84 BTUH per 100 CFM of evaporator coil air for each degree below 80 F, or add 84 BTUH per 100 CFM of evaporator coil air per degree above 80 F. CAPACITIES AT 95 F OUTDOOR., 75 F DB AND 63 F WB INDOOR TOTAL MBTUH 47.48 SENSIBLE MBTUH 29.79 LATENT MBTUH 17.688 3

PC048-5A (Metric) L/S 528 621 714 Indoor Air WB Condenser Air Temperature (Degree C) 29 35 41 46 49 22.2 15.3 7.3 6.38 14.5 7.0 6.64 13.6 6.7 6.96 12.8 6.4 7.28 12.4 6.3 7.44 19.4 13.9 9.2 5.93 13.2 8.9 6.25 12.4 8.6 6.57 11.6 8.6 6.90 11.2 8.6 7.06 16.7 12.8 10.9 5.61 12.5 10.6 5.93 12.1 10.3 6.25 11.4 9.9 6.51 11.1 9.7 6.64 13.9 12.4 11.6 5.48 11.8 11.1 5.80 11.2 10.5 6.19 10.6 9.9 6.44 10.3 9.6 6.57 22.2 15.8 8.2 6.51 15.0 7.9 6.83 14.2 7.6 7.15 13.2 7.2 7.48 12.7 7.0 7.64 19.4 14.6 10.5 6.12 13.8 10.2 6.44 12.9 9.9 6.77 12.1 9.6 7.09 11.7 9.4 7.25 16.7 13.5 12.5 5.80 12.8 12.0 6.12 12.3 11.4 6.44 11.6 10.8 6.83 11.2 10.5 7.02 13.9 13.4 12.6 5.80 12.8 12.0 6.12 12.3 11.4 6.44 11.6 10.8 6.83 11.2 10.5 7.02 22.2 16.3 8.9 6.64 15.4 8.6 6.96 14.5 8.3 7.28 13.6 8.1 7.60 13.2 8.0 7.77 19.4 15.0 11.7 6.25 14.2 11.4 6.57 13.4 11.0 6.90 12.5 10.7 7.22 12.1 10.6 7.38 16.7 14.3 13.4 6.06 13.5 12.7 6.38 12.9 12.1 6.70 12.1 11.4 7.09 11.7 11.1 7.28 13.9 14.3 13.4 6.06 13.5 12.7 6.38 12.9 12.1 6.70 12.1 11.4 7.09 11.7 11.1 7.28 capacity shown is gross capacity. sible heat capacities shown are based on 80 F (26.7C) DB entering air at the evaporator coil. For sensible heat capacities at other than 80 F (26.7) DB, deduct 84 BTUH (0.25 KW) per 100 CFM (50L/s) of evaporator coil air per 1 F (0.6C) below 80 F (26.7C), or add 84 BTUH (0.025 KW) per 100 CFM (50 L/s) of evaporator coil air per 1 F (0.6C) above 80 F (26.7C). h h h PC060-5A (Metric) L/S 762 897 949 Indoor Air WB Condenser Air Temperature (Degree C) 29 35 41 46 49 22.2 18.9 9.2 6.38 17.8 8.8 6.64 16.8 8.4 6.96 15.8 8.0 7.28 15.3 7.8 7.44 19.4 17.2 11.5 5.93 16.3 11.1 6.25 15.3 10.7 6.57 14.3 10.7 6.90 13.8 10.7 7.06 16.7 15.8 13.6 5.61 15.4 13.3 5.93 15.0 12.9 6.25 14.1 12.4 6.51 13.7 12.1 6.64 13.9 15.3 14.5 5.48 14.6 13.9 5.80 13.8 13.1 6.19 13.1 12.4 6.44 12.7 12.0 6.57 22.2 19.5 10.2 6.51 18.5 9.8 6.83 17.5 9.6 7.15 16.3 9.1 7.48 15.7 8.8 7.64 19.4 18.0 13.1 6.12 17.0 12.7 6.44 16.0 12.4 6.77 15.0 12.0 7.09 14.4 11.8 7.25 16.7 16.7 15.7 5.80 15.8 15.0 6.12 15.1 14.3 6.44 14.3 13.5 6.83 13.9 13.1 7.02 13.9 16.5 15.8 5.80 15.8 15.0 6.12 15.1 14.3 6.44 14.3 13.5 6.83 13.9 13.1 7.02 22.2 20.1 11.1 6.64 19.0 10.7 6.96 17.8 10.3 7.28 16.8 10.1 7.60 16.3 9.9 7.77 19.4 18.5 14.7 6.25 17.5 14.3 6.57 16.5 13.8 6.90 15.5 13.4 7.22 15.0 13.2 7.38 16.7 17.7 16.7 6.06 16.7 15.9 6.38 16.0 15.2 6.70 15.0 14.3 7.09 14.4 13.8 7.28 13.9 17.7 16.7 6.06 16.7 15.9 6.38 16.0 15.2 6.70 15.0 14.3 7.09 14.4 13.8 7.28 capacity shown is gross capacity. sible heat capacities shown are based on 80F (26.7C) DB entering air at the evaporator coil. For sensible heat capacities at other than 80 F (26.7) DB, deduct 84 BTUH (0.25 KW) per 100 CFM (50L/s) of evaporator coil air per 1 F (0.6C) below 80 F (26.7C), or add 84 BTUH (0.025 KW) per 100 CFM (50 L/s) of evaporator coil air per 1 F (0.6C) above 80 F (26.7C). h h h 4

Dimensions A B C D E F G 63.15 [160.4] 32.15 [81.7] 34.62 [87.9] 32.50 [82.6] 19.56 [49.7] 27.06 [68.7] 2.12 [5.4] Unit with Circular Duct Panel Added A B C D E F G H* 10.75 [27.3] 20.25 [51.4] 3.75 [9.5] 2.00 [5.1] 9.00 [22.9] 14.00 14.00 * H return opening is equivalent to round duct stated 18.00 [45.7] A B C D E F G H I J 3.75 [9.5] 14 6.25 [15.9] 14 14 24 [61.0] [47.4] 18.68 [29.5] 11.62 2.25 [5.7] 2.75 [7.0] 5

Schematic Wiring Diagrams BTDR CAP COMP CM CC CH EM GL PL SC TH LPS HPS BLOWER TIME DELAY RELAY CAPACITOR COMPRESSOR CONDENSOR MOTOR CONTACTOR CRANKCASE HEATER EVAPORATOR MOTOR GROUND LUG PLUG SPLICE CONNECTOR THERMOSTAT LOW PRESSURE SWITCH HIGH PRESSURE SWITCH MARK TERMINAL UNMARKED TERMINAL * WIRE SPLICE W - WHITE G - GREEN R - RED Y - YELLOW NOTE: CRANKCASE HEATER SUPPLIED ON 5 TON UNITS ONLY. 6

This page has been intentionally left blank. 7

Quality Makes the Difference! All of our systems are designed and manufactured with the same high-quality standards, regardless of size or efficiency. We have designed these units to significantly reduce the most frequent causes of product failure. They are simple to service and forgiving to operate. We use quality materials and components. Finally, every unit is run-tested before it leaves the factory. That s why we know...there s no better quality. Visit our web site at www.goodmanmfg.com for information on: Goodman Products Customer Services Parts Goodman Manufacturing Company, L.P. 2550 North Loop West, Suite 400 Houston, TX 77092 USA Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. Copyright 2003 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA. Goodman products are made proudly in the USA. 8