Technical Data Submittal Document

Similar documents
Drawing Submittal Package

Drawing Submittal Package

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Technical Data Submittal Documents

Technical Data Submittal Documents

Model GPP Full Service Reduced Voltage Part Winding Electric Fire Pump Controller

Model GPA Full Service Full Voltage Across the Line Start Electric Fire Pump Controller

Model GPW Full Service Reduced Voltage Wye-delta Closed Electric Fire Pump Controller

Model GPS Full Service Reduced Voltage Soft Start Soft Stop Electric Fire Pump Controller

Model GPS + GPU Full Service Reduced Voltage Soft Start Soft Stop Electric Fire Pump Controller with Automatic Power Transfer Switch

Model GPW + GPU Full Service Reduced Voltage Wye-delta Closed Electric Fire Pump Controller with Automatic Power Transfer Switch

Model GPY + GPU Full Service Reduced Voltage Wye-delta Open Electric Fire Pump Controller with Automatic Power Transfer Switch

Model GPS + GPU Full Service Reduced Voltage Soft Start Soft Stop Electric Fire Pump Controller with Automatic Power Transfer Switch

LMR Electric Fire Pump Controllers Features

LMR Electric Fire Pump Controllers Features

Options for Diesel Fire Pump Controllers

FT60 Reduced Voltage - Autotransformer

FDF Foam Pump Controllers Features

FD30 Full Voltage - Across the Line July 2011

Customer Connection Terminals Connection terminals for external customer connections, are located at the top of the Power I/O board.

FT40 Reduced Voltage - Part Winding. Electrically and Mechanically

FT20 Full Voltage - Limited Service. Electrically and Mechanically

Transfer Switch Features

Transfer Switch Features

Soft Start Series MP700 Solid State, Reduced Voltage

Fire Pump Controllers Foam (Additive) Controllers

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

Model GPD Diesel Engine Driven Fire Pump Controller

DIESEL Engine Fire Pump Controllers Features

Across-the-Line SERIES MP300 Combined Manual and Automatic

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

Variable Frequency Drive SERIES MP800 VFD

Fire Pump Controllers Medium Voltage Controllers

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

FDJ SERIES Jockey Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION FIRE PUMPS 1.00 PART 1 & GENERAL Description of Work. A. Provide pumps for fire suppression Section Includes

SECTION Fire Pumps

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

Microprocessor Based Wye-Delta Reduced Current Type Starting

SECTION AUTOMATIC TRANSFER SWITCHES

Fire Pump Controller. For Electric Motor Driven Fire Pumps. Wye Delta Reduced Current Types

Remote Alarm Panels Features

INSTALLATION AND MAINTENANCE MANUAL FOR ELECTRIC FIRE PUMP CONTROLLERS MODEL GPX

P.C. Simonton & Associates, Inc. Consulting Engineers. Paul C. Simonton

CONTENTS AUTOMATIC TRANSFER SWITCHES

Guide Specification Model CTG Automatic Transfer Switch

PILOT SERIES MPT700TS

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Specification/ Data Sheet

A. This Section includes transfer switches rated 600 V and less, including the following:

PowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.

EATON LMR Plus Electric Fire Pump Controllers

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

PUMP CONTROL CENTER (PCC)

ASCO Series 185 Power Transfer Switches

PART GENERAL 1.01 SECTION INCLUDES

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

MANUAL FOR MODEL MP600 HIGH VOLTAGE ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS

Installation Operation Maintenance

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Digital Control Systems & Remote Communications Options

SECTION AUTOMATIC TRANSFER SWITCHES

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

7800 SERIES RM7888A Relay Module

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Model APD. Remote alarm panel for diesel motor driven fire pump. Drawing Submittal Package

CHECKFIRE 210 Detection and Actuation System

70E Pressure Booster. Bell & Gossett. Bulletin D-215D. Efficient Operation. Easy to Select and Install. Quick Set-up through EZ Start

RAYCHEM NGC-30 COMPONENTS

MPT Electric Fire Pump Controller

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Application Manual LT-6617 Rev. 1 July 2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

AS950 REFRIGERATED SAMPLERS

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

FTA550 JOCKEY PUMP CONTROLLERS

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

Fluid Cooler Fan and Pump control panel

7800 SERIES RM7888A Relay Module

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

30.45 Electric Release PDRP-2001

TS 910/TS 920 AUTOMATIC TRANSFER SWITCHES OWNERS MANUAL

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

Transcription:

Project: Customer: Engineer: Pump Manufacturer: Technical Data Submittal Document Model GPL + GLU Limted Service Full Voltage Across the Line Start Electric Fire Pump Controller Contents: Data Sheets Dimensional Data Wiring Schematics Field Connections Note: The drawings included in this package are for controllers covered under our standard offering. Actual AS BUILT drawings may differ from what is shown in this package. December 2014

Technical Data Model GPL + GLU Electric Fire Pump Controller From Automatic Power Transfer Switch* 3L2 3L1 4L2 1M T2 T1 M CR4 1M 3L1 3L2 Starting Method: Full Voltage Across the line (Direct on line) Typical Voltage Applied at Start: 100% Inrush Current: 6 x normal load current Starting Torque: 100% Motor Type: Across the line (Direct on line) No. of Contactors: 1 at 100% of horsepower Min. ampacity of motor conductors: 3 at 125% x 100% of Full load Current (FLC) Shortcircuit 208V to 240V- 1ph - 50/60Hz Withstand Rating Normal Power Alternate Power Standard 65,000A Optional n/a Standard, Listings, Approvals and Certifications Enclosure Built to NFPA 20 (latest edition) UL218 - Fire Pump Controllers Underwriters Laboratory (UL) UL 1008 - Automatic power transfer switches for fire pump controllers CSA C22.2 No. 14 Industrial Control Equipment New York City Accepted for use in the City of New York by the Department of Buildings Protection Rating Standard: NEMA 2 Optional NEMA 12 NEMA 3 NEMA 3R NEMA 4 Accessories Wall mounting lugs Keylock handle NEMA 4X-304 sst painted NEMA 4X-304 sst brushed finish NEMA 4X-316 sst painted NEMA 4X-316 sst brushed finish Paint Specifications Red RAL3002 Powder coating Glossy textured finish *Please see Disconnecting Means details on page 3. December 2014 2

Technical Data Model GPL+ GLU Electric Fire Pump Controller Limitations Surge Suppression Disconnecting Means Service Entrance Rating Emergency Start Handle Electrical Readings Pressure Readings Pressure and Event recorder Pressure Sensing Across the line starting only Horsepower rating of maximum 30hp Can only be installed where acceptable by the authority having jurisdiction Not accepted in FM insured property Surge arrestor rated to suppress surges above line voltage Circuit breaker (inverse time non ajustable) rated between 150% and 250% of motor full load current Suitable as service entrance equipment Push and slide to lock Across the line start (direct on line) Voltage phase to phase (normal power) Amperage of each phase when motor is running Continuous system pressure display Cut-in and Cut-out pressure settings Pressure readings with date stamp Event recording with date stamp Under regular maintained operation, events can be stored in memory for up to 5 years. Data viewable on operator interface display screen Downloadable by USB port to external memory device Pressure transducer for fresh water application Pressure sensing connection 1/2 Female NPT Rated for 0-500PSI working pressure (calibrated at 0-300psi) Internally mounted December 2014 3

Technical Data Model GPL + GLU Electric Fire Pump Controller Visual Indications & Alarms Power available Phase reversal Motor run Pump room alarm Motor trouble Phase loss Phase unbalance Low water level Locked rotor Periodic test Fail to start Low discharge pressure Low pump room temperature Pump on demand/automatic start Emergency start Manual start Deluge valve start Remote automatic start Remote manual start Overcurrent Undercurrent Undervoltage Overvoltage Remote Alarm Contacts ViZiTouch Operator Interface Operation SPDT-8A-250V.AC Power available Phase reversal Motor run Common pump room alarm Overvoltage Undervoltage Phase unbalance Low pump room temperature High Pump room temperature Common motor trouble Overcurrent Fail to start Undercurrent Ground fault Embedded microcomputer with software PLC logic 4.2 color touch screen (HMI technology) Upgradable software Expandable storage Multi-language Start on pressure drop Automatic Start Remote start signal from automatic device Start pushbutton Run test pushbutton Manual Start Deluge valve start Remote start from manual device Manual with Stop pushbutton Stopping Automatic after expiration of minimum run timer ** Timers Actuation Mode Field Adjustable & Visual Countdown Visual Indication Minimum run timer **(off delay) Sequential start timer (on delay) Periodic test timer Pressure Non-pressure Automatic Non-automatic **Can only be used if approved by the AHJ December 2014 4

Technical Data Model GPL+ GLU Electric Fire Pump Controller Automatic Power Transfer Switch Surge Suppression Disconnecting Means Visual Indications Surge arrestor rated to suppress surges above line voltage Circuit breaker (inverse time non ajustable) rated between 150% and 250% of motor full load current Alternate (emergency) isolating switch in the OFF position Alternate (emergency) voltage phase to phase Transfer switch in normal position Transfer switch in alternate (emergency) position Transition timers Transfer switch test pushbutton Bypass for re-transfer and generator shutdown Electrically operated and mechanically held in the normal or alternate position Provision for manual operation Remote Alarm Contacts SPDT-8A-250VAC Isolating switch in the OFF position Transfer switch in normal position Transfer switch in alternate (emergency) position Time Delays Momentary normal power outage override (factory set at 3 sec - field adjustable 1 to 3 sec) Alternate (emergency) power available delay (factory set at 3 sec - field adjustable 1 to 3 sec) Transfer trouble delay (factory set at 20 sec - field adjustable 1 to 60 sec) Retransfer to normal (factory set at 5 min - field adjustable 1 to 20 min) Generator cooldown (factory set at 5 min - field adjustable 1 to 20 min) Voltage Sensing Transfer to alternate (normal power dropout) 85% of nominal - field adjustable 0 to 100% Phase reversal transfer to alternate Retransfer to normal (normal power pickup) 90% of nominal - field adjustable 0 to 100% Audible Alarm (AIS Open) 4 alarm bell - 85 db at 10ft. (3m) Generator Start Connection SPDT-8A-250V.AC December 2014 5

Technical Data Model GPL + GLU Electric Fire Pump Controller A4 A8 A9 A10 A11 A13 A16 B11 B11B B19 B21 C1 C4 C6 C7 C10 C11 C12 C14 C15 C16 C17 C18 Flow switch provision Foam pump application w/o pressure transducer and run test solenoid valve Low zone pump control function Medium zone pump control function High zone pump control function Non-pressure actuated controller w/o pressure transducer and run test solenoid valve Lockout/interlock circuit from equipment installed inside the pump room Built in alarm panel (120V.AC supervisory power) providing indication for: Audible alarm & silence pushbutton for motor run, phase reversal, loss of phase. Pilot lights for loss of phase & supervisory power available Built in alarm panel same as B11 but 220-240VAC supervisory power High motor temperature thermistor relay c/w visual indication and alarm contact (Form C-SPDT) Ground fault alarm detection c/w visual indication and alarm contact (Form C-SPDT) Extra motor run alarm contact (Form C-SPDT) Periodic test alarm contact (Form C-SPDT) Low discharge pressure alarm contact (Form C-SPDT) Low pump room temperature alarm contact (Form C-SPDT) Low water reservoir level alarm contact (Form C-SPDT) High electric motor temperature alarm contact (Form C-SPDT) High electric motor vibration c/w visual indication and alarm contact (Form C-SPDT) Pump on demand/automatic start alarm contact (Form C-SPDT) Pump fail to start alarm contact (Form C-SPDT) Control voltage healthy alarm contact (Form C-SPDT) Flow meter valve loop open c/w visual indication and alarm contact (Form C-SPDT) High water reservoir level c/w visual indication and alarm contact (Form C-SPDT) D1 D1A D10 D14 D14A D14B D15 D18 D26 D26A D27 D27A D28 D34 D35 D36 D36A D37 E1 E2 E3 F2 F2A F2B Low suction pressure transducer for fresh water rated at 0-300PSI with visual indication and alarm contact Low suction pressure transducer for sea water rated at 0-300PSI with visual indication and alarm contact Omit mounting feet (when applicable) Anti-condensation heater & thermostat (normal power section) Anti-condensation heater & humidistat (normal power section) Anti-condensation heater & thermostat & humidistat (normal power section) Tropicalization CE Mark with factory certificate Modbus RTU provision Modbus TCP/IP provision Motor heater connection (external single phase power source and heater on/off contact) Motor heater connection (internal single phase power source and heater on/off contact) Customized drawing set Field programmable I/O board - 8 Input / 5 output Field programmable I/O board - 8 Input / 10 output Redundant pressure transducer for fresh water rated for 0-500PSI (calibrated at 0-300PSI) Redundant pressure transducer for sea water rated for 0-500PSI (calibrated at 0-300PSI) Window kit for operator interface Permanent load shedding contacts Temporary pump motor start period load shedding contacts Temporary & permanent load shedding contacts Anti condensation heater & thermostat (alternate power section) Anti condensation heater & humidistat (alternate power section) Anti condensation heater & thermostat & humidistat (alternate power section) C19 Emergency start alarm contact (Form C-SPDT) C20 Manual start alarm contact (Form C-SPDT) C21 Deluge valve start alarm contact (Form C-SPDT) C22 Remote automatic start alarm contact (Form C-SPDT) C23 Remote manual start alarm contact (Form C-SPDT) C24 High pump room temperature alarm contact (Form C-SPDT) Cx Additional visual and alarm contact (specify function) (Form C-SPDT) Note: Options chosen from this page are not electrically represented on the wiring schematics in this submittal package. December 2014 6

Technical Data Model GPL+ GLU Electric Fire Pump Controller L01 Other language and English (bilingual) L11 Czech L02 French L12 Portuguese L03 Spanish L13 Dutch L04 German L14 Russian L05 Italian L15 Turkish L06 Polish L16 Swedish L07 L08 L09 L10 Romanian Hungarian Slovak Croatian L17 L18 L19 L20 Bulgarian Thai Indonesian Slovenian Note: Options chosen from this page are not electrically represented on the wiring schematics in this submittal package. December 2014 7

Technical Data Model GPL + GLU Electric Fire Pump Controller ViZiTouch Operator Interface 1 3 2 4 5 6 7 8 9 10 11 12 13? 14 1 - Power on LED 2 - Color touch screen 3 - Alarm LED 4 - HOME page button 5 - ALARM page button 6 - CONFIGURATION page button 7 - HISTORY page button 8 - USB port 9 - START button 10 - TRANSFER SWITCH TEST button 11- Contextual navigation pad 12 - STOP button 13 - RUN TEST button 14 - HELP button December 2014 8

Electric Fire Pump Controller Model:GPL Terminal Diagram and Sizing Power Terminals Model : GPL 1 PHASE Bonding Ground Gnd Gnd Incoming Power L1 L2 CB T1 1M T2 Built to the latest edition of the NFPA 20 standard Notes: 1 - For proper wire sizing, refer to NFPA70 and NEC (USA) or CEC (Canada) or local code. 2 - Controller suitable for service entrance in USA. 3 - For more accurate motor connections refer to motor manufacturer or motor nameplate. 4 - Controller is phase sensitive. 5 - Field wiring and lug sizes based on copper conductors only. Do not use aluminium conductors. M Circuit breaker (CB) Field Wiring according to Bending Space (AWG or MCM). TERMINALS L1 - L2 Bending Space Voltage 208 HP 220 to 240 3 1x (10 to 1) 1x (10 to 1) 3 " (76 mm) 5 7.5 10 15 1x (8 to 1) 1x (6 to 1) 1x (4 to 1) 1x (3 to 1) 1x (8 to 1) 1x (8 to 1) 1x (6 to 1) 1x (3 to 1) (Use Copper Conductors Only) Wiring Size for motor connection for Model GPL (AWG or MCM). TERMINALS T1 - T2 HP Voltage 208 220 to 240 3 1x (10 to 3) 1x (10 to 3) 5 7.5 10 15 1x (8 to 3) 1x (6 to 3) 1x (4 to 1) 1x (3 to 1) 1x (8 to 3) 1x (8 to 3) 1x (6 to 1) 1x (3 to 1) (Use Copper Conductors Only) Drawing for information only. Manufacturer reserves the right to modify this drawing without notice. For drawing for approval or installation, please contact manufacturer. GPL-TD-ViZi NYC Dpt of Building Approved REV. DESCRIPTION DD/MM/YY 6 UPDATE WIRE SIZE 06/11/14 5 FIELD PROG 11/11/13 4 GENERAL REVISION 19/10/12 Drawing number GPL-TD500 1/2 /E

Electric Fire Pump Controller Terminal Diagram and Sizing Model:GPL Built to the latest edition of the NFPA 20 standard Remote Alarm Terminals (I/O board) Control Terminals (I/O board) Motor Running Normally closed Opens to alarm Normally open Closes to alarm J19-14 J19-11 J19-12 MOTOR RUN Remote Manual Start Close to start pump Remote Manual Start 23 J25 24 Power Available (Fail Safe) Normally open Closes to alarm Normally closed Opens to alarm J40-14 J40-11 J40-12 TB1 Lockout Lockout Close to block start 25 J25 Signal 26 Phase Reversal Normally closed Opens to alarm Normally open Closes to alarm J42-14 J42-11 J42-12 TB2 Remote Automatic Start Automatic Start Open to start pump 27 J1 J25 If used, remove jumper J1 28 Pump Room Alarm Normally closed Opens to alarm Normally open Closes to alarm (RE-ASSIGNABLE) J37-14 J37-11 J37-12 TB3 Deluge Valve Deluge Valve Open to start pump 29 J2 J25 Start If used, remove jumper J2 30 Motor Trouble Normally closed Opens to alarm Normally open Closes to alarm (RE-ASSIGNABLE) J39-14 J39-11 J39-12 TB4 Field Connections for External Devices (I/O board) (Field Programmable) Normally closed Opens to alarm Normally open Closes to alarm J41-14 J41-11 J41-12 TB5 Water Reservoir Low Water Reservoir Low Close to signal alarm 31 J25 Signal 32 Flow / Zone Flow / Zone Start / Stop Close to signal alarm 33 J25 Signal 34 Drawing for information only. Manufacturer reserves the right to modify this drawing without notice. For drawing for approval or installation, please contact manufacturer. GPL-TD-ViZi NYC Dpt of Building Approved REV. DESCRIPTION DD/MM/YY 6 UPDATE WIRE SIZE 06/11/14 5 FIELD PROG 11/11/13 4 GENERAL REVISION 19/10/12 Drawing number GPL-TD500 2/2 /E

Automatic Power Transfer Switch For Limited Service Pump Controller Terminal Diagram and Sizing Model:GLU Built to the latest edition of the NFPA 20 standard Power Terminals Bonding Ground 1 Phase Incoming Power Gnd AL1 ACB AL2 Notes: 1 - For proper wire sizing, refer to NFPA70 and NEC (USA) or CEC (Canada) or local code. 2 - Controller suitable for service entrance in USA. 3 - Controller is phase sensitive. 4 - Field wiring and lug sizes based on copper conductors only. Do not use aluminium conductors. Circuit Breaker (CB) Field Wiring according to Bending Space (AWG or MCM). TERMINALS L1 - L2 Bending Space Voltage 208 HP 220 to 240 3 1x (10 to 1) 1x (10 to 1) 3 " (76 mm) 5 7.5 10 15 1x (8 to 1) 1x (6 to 1) 1x (4 to 1) 1x (3 to 1) 1x (8 to 1) 1x (8 to 1) 1x (6 to 1) 1x (3 to 1) (Use Copper Conductors Only) Remote Alarm Terminal (I/O board Tr. Sw.) Tr. Sw. in Alternate Position Tr. Sw. in Normal Position Closes when Tr. Sw. in Alternate Position Closes when Tr. Sw. in Normal Position Opens when Tr. Sw. in Alternate Position Opens when Tr. Sw. in Normal Position 14 12 11 14 12 11 ALT. POS. NOR. POS. J39 ACB in OFF or Tripped Opens when ACB is in OFF or Tripped Closes when ACB is in OFF or Tripped 14 12 11 ACB Field Connections for External Devices (I/O board Tr. Sw.) Generator Start Normally closed Opens to start generator Normally open Closes to start generator 14 11 12 GEN J39 Drawing for information only. Manufacturer reserves the right to modify this drawing without notice. For drawing for approval or installation, please contact manufacturer. GPL-TD-ViZi NYC Dpt of Building Approved REV. DESCRIPTION DD/MM/YY 3 UPDATE WIRE SIZE 06/11/14 2 GENERAL REVISION 06/08/12 1 ADD COPPER NOTES 19/06/12 Drawing number GLU-TD500 /E