EasiHeat Mechanical Installation and Commissioning Instructions

Similar documents
A complete, compact steam heat exchange solution for process and domestic water heating requirements.

Universal control panel incorporating SIMS TM technology HTG Installation and Maintenance Instructions

SX65 and SX75. Electronic process controllers

LC2200 Level Controller Installation and Maintenance Instructions

CRU-S Series Stainless Steel Condensate Recovery Unit

MFP14 Automatic pumps for condensate and other industrial fluids

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

heat interface units A BOILER WITHOUT A FLAME

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

MFP14 Automatic pumps. for condensate and other industrial fluids

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013

LC3000 Level Controller Installation and Maintenance Instructions

205 Control Installation and Maintenance Instructions

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Inverted Bucket Steam Traps

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

Herz York Direct Heat Interface Unit

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

Installation and Commissioning Manual

Operation & Maintenance Manual

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

STEAM VALVE SUPPLY & SYSTEM DESIGN

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Instructions for Use Installation and Servicing

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

FT14 Ball Float Steam Trap (Screwed)

Insty-Pac Steam Humidifiers

Open System Condensate receiver tank of cylindrical. design type SDR A with highpressure

Breeze extended to include Variable Speed Drives Breeze range extended to include Steam Primary

PA ma Loop Powered Level Preamplifier

Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW)

INSTY-PAC INTERNAL MOUNT WELDED MULTIPLE TUBE ASSEMBLY

Function of the FENIX Hydrodynamic Trap working on Variable Load Applications

Additional Cooling Stage (FT174-43) Adds the location points and plumbing for a fourth heat exchanger.

Why steam trap survey?

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Flash Condensing De-aerator Heads Installation and Maintenance Instructions

David Cronin-Ohio Valley Area Manager. Heat Transfer, Controls & Instrumentation, Metering.

Thermostatic mixing valves with interchangeable cartridges

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

CHILLER. Operator s & Installation Manual

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Compact HE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Miniature-scale research & development technology

LC2610 Level Controller Installation and Maintenance Instructions

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

INSTALLATION AND MAINTENANCE INSTRUCTIONS. IM US March RediHeat. Table Of Contents. I. Installation RediHeat Start-Up Procedure 4

Steam Traps and Steam Specialties

Niles Steel Tank Hot Water Generator Installation and Operation Manual

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

Electronic steam boiler controls

Quantum. Installation, User and Service Manual. Hot Spring

spiraxsarco.com/global/us Product Overview A quick guide to products for steam and related industrial fluids

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

Installation, Operation and Maintenance Instructions for PlantPac Steam Plate Heat Exchanger Package

Unfired Steam Generators (Series RB) Installation, Operation and Maintenance

INSTY-PAC EXTERNAL MOUNT WELDED MULTIPLE TUBE ASSEMBLY

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Thermostatic mixing valves with replaceable cartridge for centralized systems

Contact person RISE Date Reference Page. Daniel Månsson P (13) Energy and circular economy

prestige Control Application Supplement - TriMax

1U ULTRA Compact System

Contact person RISE Date Reference Page Björn Folkeson P (13) Energy and circular economy

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Instructions for installing and using HIPER HIU UK patent applied for:

LONGONI ENGINEERING SRL

STREBEL S-CB + Cascade Kits

Titanium Plate Heat Exchanger. Installation & Operating Manual

Spiratec R16C Automatic Steam Trap Monitor

Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy

Contact person RISE Date Reference Page Björn Folkeson P03675B 1 (11) Energy and circular economy

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

STEAM TRAPS FOREST PRODUCTS LIBRARY FOREST RESEARCH LABORATORY OREGON STATE UNIVERSITY. Information Reviewed and Reaffirmed. August No.

unistor Instructions for Installation and Use Unvented hot water storage cylinder

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

AP-EH500-L/RQA9837. Installation Guide

Contact person Date Reference Page Björn Folkeson P (14) Energy and bioeconomy

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

prestige Control Application Supplement - TriMax

Contact person Date Reference Page Daniel Månsson P (13) Energy and circular economy

SECTION Boiler Controls & Waste Heat Recovery

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

Unvented Direct & Indirect Hot Water Cylinders (400L L)

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

Electronic Dual Cylinder Thermostat Installation Instructions

Transcription:

2230050/2 IM-S27-05 CH Issue 2 EasiHeat Mechanical Installation and Commissioning Instructions 1 General safety information 2 General product information 3 Installation 4 Commissioning 5 Operation 6 Maintenance Printed IM-S27-05 in the CH UK Issue 2 Copyright 20021

1 General safety information Note: This document refers only to the mechanical installation and commissioning of the EasiHeat unit and should be used in conjunction with the relevant IMIs for the other system components and supplementary safety information for all the system components. Warning Your attention is drawn to Safety Information Leaflet IM-GCM-10, as well as to any National or Regional regulations. This product is designed and constructed to withstand the forces encountered during normal use. Use of the product for any purpose other than its intended use could cause damage to the product and may cause injury or fatality to personnel. Before any installation or maintenance procedure, always ensure that all primary steam and condensate return lines and secondary water lines are isolated. Ensure any residual internal pressure in the system or connecting pipework is carefully relieved. Allow hot parts to cool before commencing work, to avoid the risk of burns. Always wear appropriate safety clothing before carrying out any installation or maintenance work. Lifting The EasiHeat unit should be lifted by a suitable forklift truck, from the base, placed in position and securely bolted to the floor. Note: - On no account is the EasiHeat unit to be lifted by any other part, other than the base. - Sufficient space should be provided in its location to allow access for maintenance. - The core unit occupies a maximum of 1.2 m³ space (maximum footprint of 955 x 719 mm). The full package option occupies a maximum of 3.55 m³ (maximum footprint of 1 830 x 1 133 mm). 2 IM-S27-05 CH Issue 2

2 General product information 2.1 General information EasiHeat systems use steam to provide accurate heating of low temperature hot water (HTG), domestic hot water (DHW) or hot water for processes. Systems can be sized for any heating duty from 100 kw to approximately 1.2 MW and are supplied fully assembled and pressure tested, ready for installation. The EasiHeat base unit provides the core of the system, while options 1 to 6 (see Section 2.2) include additional features such as: high limit package, stop valve package and separator package variants. The EasiHeat unit consists of the following core items (refer to Figure 1): - Steam plate heat exchanger, type TS6-M. - Pneumatic or electrically actuated steam control valve and positioner. - Controller and sensor. - Condensate removal solution (either a float trap or an automatic pump trap). - Ancillaries. EH-PT-DHW EH-ST-HTG Note: For additional information about any particular product used in the construction of this unit see the relevant Technical Information Sheet. Fig. 1 IM-S27-05 CH Issue 2 3

2.2 Identification The unit is available in the following package options: Note: Depending upon the operating conditions of the package the plate heat exchanger gasket will either be manufactured from EPDM or HeatSeal. Option 1 - EH- _ - - - _ - Basic EasiHeat unit with either pneumatic control valves or electric control valves. Option 2 - High limit package EH- _ - - - _ -HL A pneumatic or electrically actuated, fail-safe high limit function, automatically isolating steam if a pre-set secondary temperature is reached. High limit option Option 3 - Stop valve package EH- _ - - - _ -V Bellows sealed stop valves fitted to the steam inlet and condensate outlet connections, to enable isolation of the primary circuit, together with a strainer to protect the temperature control valve. Stop valve set 4 IM-S27-05 CH Issue 2

Option 4 - Stop valve and separator package Separator set Stop valve set EH- _ - - - _ -VS The stop valve package together with a separator set ensures dry saturated steam is delivered to the EasiHeat unit. Option 5 - High limit option and stop valve package Stop valve set High limit option EH- _ - - - _ -HL-V Both the high limit option and the stop valve set, combined into one package. Option 6 - Full option package EH- _ - - - _ -HL-VS A combination of all the available options to provide a fully specified EasiHeat package. Separator set Stop valve set High limit option IM-S27-05 CH Issue 2 5

3 Installation Warning: Before proceeding with any installation or maintenance work read Section 1, Safety information. 3.1 Steam and condensate connections It is important that the steam supply to the EasiHeat unit is supplied as dry and as clean as possible, in accordance with good steam engineering practice. It should also be ensured that all connecting pipework is stress free and adequately supported. The steam supply should always be maintained at the specified design pressure and temperature for the unit. The EasiHeat must not operate above the maximum steam pressure and temperature indicated on the name-plate attached to the heat exchanger. The installation of an appropriately sized safety valve, to protect any lower pressured equipment on either the primary or secondary side of the heat exchanger, is strongly recommended. Spirax Sarco supply a range of traps, strainers, separators, safety valves and pressure reducing equipment. 3.2 Air supply If a pneumatic control system is installed, connect a compressed air supply (4.5 to 8 bar g) to the pressure regulator mounted on the control valve. 3.3 Electrical supply All electrical wiring and connections should be carried out in accordance with National regulations and Standards. Electrical supply : Actuator type Power supply Supply fuse Bypass pump Actuators / solenoid valve - PN 230 Vac/50 Hz 13A (T) 230 Vac/50 Hz 230 Vac/50 Hz - EL1 230 Vac/50 Hz 13A (T) 230 Vac/50 Hz 230 Vac/50 Hz - EL2 115 Vac/50 Hz 13A (T) N/A - HTG only 115 Vac/50 Hz - EL3 230 Vac/50 Hz 13A (T) 230 Vac/50 Hz 24 Vac/50 Hz - A lockable isolator / switch disconnector should be fitted adjacent to the unit. 6 IM-S27-05 CH Issue 2

4 Commissioning We recommend the service and support of a Spirax Sarco Commissioning Engineer. Details of this service can be found by contacting Spirax Sarco. Note: In most new installations, dirt collects in the steam line during construction of piping systems. It is essential to flush this out prior to commissioning. Commissioning procedure: - Check all electrical connections are secure and as per installation drawing. - Dry commissioning valve stroke check - An initial valve stroke check should be carried out to ensure free movement of the valve stem. - Shut steam inlet valve upstream of the EasiHeat. - Open all condensate drain valves. - Switch off electrical power. - Open secondary isolating valves downstream of the EasiHeat. - Start the main secondary water circulating pump(s) if fitted. - Check for secondary water circulation through the EasiHeat. - If the circulation is okay, switch on the power to the unit (local isolator), first ensuring that the voltage and frequency are correct. - Switch on the main switch, (rocker switch adjacent to the controller). - If an SX100 controller is fitted select the required program (e.g. 2 for constant). Note: ensure the temperature setting is suitable for the application. If this needs to be altered, refer to the 'Controller Quick Set-up Manual'. - Slowly open main steam inlet valve. - Check process temperature is within the acceptable limits of the set point and that the bypass pump, if fitted, is running. Important - high limit setting: - If fitted, the high limit controller should be set at a suitable level to protect plant, process and personnel. Details of setting can be found in the separate high limit controller IMI. Care should be taken to ensure sufficient difference between the process set point and the high limit set point, to avoid any unwanted high limit tripping. - Check temperature rises to set value and controls satisfactorily. - If necessary adjust PID settings, (see DB-S27-08, 'Selecting PID settings'). We would strongly recommend that only a suitably trained controls engineer adjust these parameters. - Check operation of steam traps/ condensate pump. The EasiHeat unit is now ready for service IM-S27-05 CH Issue 2 7

5 Operation The steam flowrate is modulated to match the heat demand. The control valve is either pneumatically or electrically actuated and the system uses a rapid response Pt100 temperature sensor and programmer / controller for the precise control. The pumping trap version can operate at low or even sub-atmospheric steam pressure, in areas where there is a risk of scaling of the heat exchanger in open circuit installations such as a domestic hot water application. The EasiHeat is designed for the following applications, avoiding the requirement for large storage vessels: Low temperature hot water (LTHW, DT <25 C): Accurate temperature control is achieved whatever the heating load requirements. The response to load changes for heating circuits is excellent. Domestic hot water (DHW, DT >25 C): The Easiheat will deliver a constant stable temperature, even with the sudden and wide load changes often found in domestic hot water applications. Process heating: A wide range of duties can be satisfied. Low pressure primary operation is available for temperature sensitive fluids. 6 Maintenance General For maintenance of the individual components of the system, please see the relevant IMI s for the products concerned. High limit device testing The purpose of the test is to ensure the system operates satisfactorily when required to do so. Method 1. High limit set point test The set point of the high limit controller should be lowered, to simulate a high temperature situation. Test personnel should ensure the high limit device operates in a satisfactory manner. 2. Electrical power failure test The unit should be switched off at the controller rocker switch to simulate power failure. Examination should be made to ensure the high limit system has switched to its fail-safe mode, isolating the primary steam supply. Frequency It is essential that a competent person tests the high limit device on a frequent basis. Intervals between tests should not exceed a six month period. We do not recommend the installation of a self-acting high limit system to the Easiheat package. Scale formulation Within open systems, where there is continual make-up water, there is a risk of scale formation. The extent of the scale will depend largely upon the water quality, which varies greatly from area to area. A test, conducted by a water treatment specialist, is recommended to determine the local quality and whether problems are foreseen. After extended service, the plate heat exchanger can be easily dismantled for cleaning. If scale becomes a persistent problem, regular chemical cleaning should be considered. ¾" ports are available on the secondary inlet and outlet piping to allow easy connection for 'Clean in Place' apparatus. It should be noted that raising the steam pressure could result in an increase of scaling. 8 IM-S27-05 CH Issue 2