EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

Similar documents
EOTec 2C32 Installation Guide

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

4120 Fire Alarm Network Reference

4 Channel Contact Closure SFP DIN Fiber Link System

CCU Family of Modules

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

CX/CXB Self-Managed Ethernet Switches N-664 Network Appliance Data and Alarm I/O Device MX Series Multi-Port Switches

T3/E3 Fiber Optic Line Drivers

Call stations and extensions

Panel Mounted Fault Annunciator Series

Engineering Guideline. pac- Carriers Type Universal

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

EXCELLENCE in Solutions Products Service

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

TPM Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

Panel Mounted Fault Annunciator Series

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Noyes OFL 250B Specs Provided by

Innovative protection that combines power and flexibility

MO n : 12JMC rév A

M210 Multifunction Micro OTDR

Analog Input Module IC670ALG630

PROFIBUS Optical Bus Terminal (OBT) SIMATIC NET. PG/PC - PROFIBUS PROFIBUS Optical Bus Terminal (OBT) Introduction 1. Components of the product

VOICE ALARMING SYSTEM»ONE-BOX-DESIGN« EN / EN 54-4 / VDE / EN / VDE 0828 THE SIMPLE»ALL-IN-ONE«SOLUTION.

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

M210 Multifunction Micro OTDR

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE

USER MANUAL FOR OPERATING SYSTEM

FLX380-30x FlexTester OTDR

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

M700-Series Multifunction OTDR

CTT8 TEMPERATURE MONITOR DEVICE

Process Alarm Module RTA 421

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

MODEL 5100 VOTING LOGIC MODULE

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

VPS3 Installation Manual

C-Bus Four Channel Analogue Output Unit Installation Instructions

Four channel video link For low cost video transmission

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Power Supply Display Module PSDM. Installation and Operation Manual

Universal fault annunciator for panel mounting

palmotdr Series Handheld OTDR

Annex to: IECEx ULD U Issue. No. 2 Manufacturer: Detector Electronics Corporation Electrical apparatus: Eagle Quantum Premier system Modules

GasGard 100 Control System

WG Buried Cable Perimeter Detection System

Frequently asked questions: Intelligent Transmitter Series

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)

Danfoss gas detection Controller unit

palmotdr Series Handheld OTDR

AUTROSAFE. An interactive fire detection system for larger vessels

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Danfoss gas detection units

INSTRUCTIONS. Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH. 5.1 Rev: 4/

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

ACCESS Master MT9085 Series. Product Introduction

Danfoss gas detection units

E3 Series Broadband System

Touchpoint Pro Flexible Gas Control System

Fire Alarm Network Reference

EKL3 short circuit and earth fault indicator

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC

380 SERIES REMOTE SIREN ETSA380R

EPON ONU Optical Transceiver SFF Module

M700-Series OTDRs. or (800) , (603)

Continuous, real-time detection, alarming and analysis of partial discharge events

ESSEX ENGINEERING CORPORATION

Essentials of Fiber to the Antenna: Fronthaul Installation Test

GPON OLT Optical Transceiver SFP Module RTXM RTXM Features

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

IntesisBox BACnet/IP Server - Notifier ID3000 series

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

HT-2 / 9600 Series Control Contents

LDRA6 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev

Instruction Manual SCD24. Read this document prior to installation. Contents

910 Series Single-point heat-tracing control system

wireless. web-based. worthy of the name RACO.

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

FTB-7400E Metro/CWDM OTDR METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

REA 105 Arc Protection Module. Operator s Manual

Stratos Optical HD/SD BNC to "ST" Video Media Converter (Transmitter)

4-Channel Contact Closure Fiber Link Card System

Transcription:

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings Key Features Single and Dual Channel Self Healing Rings for High Reliability Highest number of nodes supported Fully compliant with the ControlNet specification Robust Multi-Break Management algorithm Small Form Factor, High Performance Laser Optics 1310nm lever-latch SFP laser transceiver Real-time indication of fiber optic health Single/Multi-mode conversion available Global Ring Failure Alarm with Comprehensive Diagnostics Indicator and relay monitor Four additional alarm relay outputs Minimizes downtime Compact Enclosure Reduced installation space required Stand alone 35 mm DIN-rail mounting Industrial Design Designed for use in Class I, Division 2 hazardous locations** CE approved Accessories Available Duplex patch cords ( to ST, to SC, etc.) Link cables Spare SFP transceivers EOTec 2000 ControlNet Fiber Optic Communications Modules *Patents pending **Certification pending EXCELLENCE in Solutions - Products - Service

Overview The EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules provide the highest assurance of network performance for any ControlNet network. Self- Healing Ring networks for both the Channel A and the Channel B are supported simultaneously providing multiple pathways for data routed to the end nodes in the system. Network errors are communicated through advanced diagnostics to give the operator early indication of communication faults without losing any communications to the ControlNet end nodes. The Model 2C31 is intended for Single Self-Healing Ring applications, while the Model 2C32 is designed for Dual Self-Healing Ring systems. Weed also manufactures modules for other ControlNet topologies, including copper to fiber conversion (Point-to-Point), STAR, Daisy Chain and Cascading Tree. Model 2C31 Self-Healing Ring Module Model 2C32 Dual Self-Healing Ring Module The Technology of Reliability Single and Dual Self-Healing Rings Many industrial processes require very precise control. Failure of communications between the various elements of a control system may cause serious problems. Therefore, the communication systems employed have to be robust. Weed s 2C31 and 2C32 Self-Healing Ring Modules address this need by providing multiple communication paths between the various elements of the system, and utilize advanced Downstream Multicasting technology. In the event of a failure on one communication path, communications are still maintained along a secondary path or, in the case of a dual ring, tertiary paths. Downstream Multicasting transmits an incoming message in multiple directions and insures that while directing the message toward all nodes in the ring it is never retransmitted 2 Weed Instrument Fiber Optics

back to the point of origin. This communication method employs a Master or ring control module which will direct traffic and guard against duplicate message delivery. Each fiber ring must include one master module to insure proper communication between all nodes in the ring. As shown in the Model 2C31 single ring diagram on page 2, data enters the ring in the middle node. Primary and secondary data flow in two separate directions around the ring. Primary data is defined as the data that arrives at the module first. When a data packet flows around the ring, the primary data is delivered to other ControlNet segments. Secondary data will only be used in the case of fiber break. For critical applications the Model 2C32 provides a highly robust, dual-channel ControlNet solution. As with the single ring, Downstream Multicasting insures that data is delivered to all consumers within the appropriate network update time. In this configuration, not only is a second ring provided to support both Channel A and B ControlNet data packets, a third or tertiary communication path is also available. Because there is an additional path, more fiber breaks are supported without any loss in either communication channel. Because redundant systems are typically used in operations that can t afford a loss in data or any downtime, the 2C31 and 2C32 are supplied as standard with an extensive set of powerful diagnostic tools to warn against any faults or impending system failures. Weed Instrument Fiber Optics 3

Powerful Diagnostics Enhance Reliability and Support Preventative Maintenance Power Input Quality: Continuous monitoring of the power input is crucial when redundant communications are required. Loss of power can isolate a node and sever communication of important applications running on your network. To help insure your network against this type of node isolation, two power inputs are provided on each self-healing ring module. The module alerts you if power falls outside the proper voltage range (+15 to 30VDC) on one or both power inputs. Relay contacts are provided for each power input and will close in the alarm condition. LEDs on each unit will also turn red which allows maintenance personnel to quickly isolate the source of the problem. A power alarm is one of three fault conditions that will set a Global Alarm. Optical Fiber Fault: Fiber is used to create a physical link between all self-healing ring modules. A fiber ring provides a redundant path of communication in case a fiber fails or is broken. To continue to insure this redundancy it is very important to keep this ring intact. Data on the optical fiber lines is constantly monitored by the module. If a fiber fails to transfer light or is broken an alarm is instantly activated. A set of relay contacts is provided for each optical receiver and will close in the alarm condition. Local identification of the source of the fiber failure is simple since there is a red LED indicator for each of the optical fiber ports. A fiber alarm is one of the three fault conditions that will set a Global Alarm. Dual-Ring Link: This feature is specific to the Model 2C32. It provides an additional interface that creates dual redundant communications. It is an additional communication channel between the two redundant rings and creates additional communication rings between all adjacent self-healing ring modules. As this channel is the key to dual redundancy, it is very important to insure communication so the module continuously monitors the data. A set of relay contacts is provided for the dual-ring communication channel and will close in an alarm condition. The link alarm is also one of the three fault conditions that will set a Global Alarm. Global Alarm: This feature is provided on both the 2C31 and 2C32. The global alarm is unique because it is passed between all modules. A set of relay contacts is provided on every module and will close in an alarm condition. As a result, only one module needs to be connected to a remote alarm to alert when a fault has occurred. There are three fault conditions that set the Global Alarm: Power Alarm: one or both power inputs are not between the specified input voltage or one has failed completely. The alarm is supported by two local LEDs and two remote screw terminal connections. Fiber Alarm: no data is received at a fiber port. Both fiber ports have an independent remote alarm. This condition is accessed by two local LEDs and two remote screw terminal connections. Link Alarm: no data is received at the link port (Model 2C32 only). The alarm is supported by a local LED and a remote screw terminal connector. 4-20mA Output: The 4-20mA output is a diagnostic interface that measures the light intensity at the receiver input of each of the fiber ports and converts it into an analog output. At 4mA there is no light received indicating bad or broken fiber. As the power or light intensity increases this measurement moves toward 20mA. These outputs are easily accessed at a terminal block connector on the front of each module. This important feature allows for real-time analysis of fiber signal strength to identify deteriorating fiber conditions and make replacements before a failure occurs. The 4-20mA output is also a useful tool during installation since it can be read via a handheld meter and will provide an indication of signal strength. This helps in finding loose or faulty connections and locating bad fiber links. Weed Instrument Fiber Optics 4

Technical Specifications Cabling and Operation ControlNet Specifications/Requirements Apply Maximum nodes 48 (using coax cable length of 250m) Maximum coax cable length 1000m (assuming 2 nodes) Trunk connection Anywhere on the trunk via ControlNet Tap with 1m drop cable required Coax cable connection BNC Data rate 5M baud Propagation delay 1μs maximum per module Fiber propagation delay 5μs/km 1.5μs/1000ft Power indicator Green LED illuminates with power applied. Solid red LED when voltage <15VDC or >30VDC Com indicator Green LED for normal condition. Flashing red/green LED, with data errors, Solid red LED for jabber condition Environmental & Safety DIN rail mounting Power input 15-30VDC, Dual Power Inputs Input power, maximum 8 Watts Transient Spike Protection 1500W 25 C (10 X 1000μs) Operating temperature range 0 to +60 C Storage temperature range -40 to +85 C Humidity (non-condensing) 5 to 95% RH Electrical Safety CSA C22.2 No. 142 (1987), IEC 60950 EMC immunity IEC61326-1:1998 Hazardous locations Designed for Class I, Division 2, Groups A, B, C, D (certification pending) Packaging (polyamide) UL 94V-0 Optical Interface Optical Wavelength 1310nm Communications Data Range Up to 155 Mbps Optical Port Connection Duplex connector (other connector options available, see accessories) Optical Dynamic Range See table below. Optical Transmit Indicator Solid green LED for normal condition. Off when no transmit Optical Receive Indicator Solid green for normal condition. Solid red when no receive, Flashing red/green when data errors received Link Interface (2C32 only) Green LED when connected. Red LED when cable is disconnected. Red/green flashing LED when there are data errors Optical Interface Table Model Fiber Type Fiber Connector Max Optical Dynamic Range, Fiber Size Typical Max Distance (mi/km) 2C31--MM/MM Multi-mode 11 db into 62.5/125μm fiber 7.5 db into 50/125μm fiber 2.5mi/4km 1.9mi/3km 2C31--SM/SM Single mode 19 db into 9/125μm fiber 12.4mi/20km 2C32--MM/MM Multi-mode 11 db into 62.5/125μm fiber 7.5 db into 50.5/125μm fiber 2.5mi/4km 1.9mi/3km 2C32--SM/SM Single mode 19 db into 9/125μm fiber 12.4mi/20km Note: SM/MM available on the same SHR module. Please consult factory for additional information. Mechanical Dimensions Weed Instrument Fiber Optics 5

Ordering Information Self-Healing Ring Modules (SHR): 2C31--MM/MM ControlNet Self-Healing Ring (SHR) Fiber Optic Communication Module, Multi-mode, connector 2C31--SM/SM ControlNet Self-Healing Ring (SHR) Fiber Optic Communication Module, Single Mode, connector Dual Self-Healing Ring Modules (DSHR): 2C32--MM/MM ControlNet Dual Self-Healing Ring (DSHR) Fiber Optic Communication Module, Multi-mode, connector 2C32--SM/SM ControlNet Dual Self-Healing Ring (DSHR) Fiber Optic Communication Module, Single Mode, connector Accessories: 2LNK-1M Link cable (for DSHR only), 1 meter 62--ST-2M Duplex Fiber Patch Cord, MM 62.5/125μm, -ST, 2 meter 62---2M Duplex Fiber Patch Cord, MM 62.5/125 μm, -, 2 meter 62--SC-2M Duplex Fiber Patch Cord, MM 62.5/125 μm, -SC, 2 meter 50--ST-2M Duplex Fiber Patch Cord, MM 50/125 μm, -ST, 2 meter 50---2M Duplex Fiber Patch Cord, MM 50/125 μm, -, 2 meter 50--SC-2M Duplex Fiber Patch Cord, MM 50/125 μm, -SC, 2 meter 9--ST-2M Duplex Fiber Patch Cord, SM 9/125μm, -ST, 2 meter 9---2M Duplex Fiber Patch Cord, SM 9/125μm, -, 2 meter 9--SC-2M Duplex Fiber Patch Cord, SM 9/125μm, -SC, 2 meter Model 2C32 Remote Link Alarm Relay Sets an alarm when the dual channel link has a communication fault Dual Remote Power Alarm Relays Sets an alarm when either input has a power fault Remote Global Alarm Relay Sets a single alarm when any power or communication fault occurs in either fiber communication ring Fiber 1 and Fiber 2 Remote Alarm Relays Sets an alarm when either optic fiber has a communications fault Dual +15 to 30VDC Power Inputs Dual power inputs to insure a constant power source Real Time 4-20mA Outputs Measures light intensity on both Fiber 1 & 2 to report real time optical fiber deterioration High Resolution LEDs Simplify local diagnostics Dual Channel Link Cable Easily connects communication between optic fiber rings Standard ControlNet BNC For a quick connection into any network Small Form-Factor Pluggable (SFP) Easy to remove 1310nm Fiber Optic Transceivers for both Single Mode and Multi-Mode applications Weed Instrument Company, Inc. 707 Jeffrey Way, P. O. Box 300 Round Rock, Texas 78680-0300 Phone: 512-434-2850, Fax: 512-434-2851 E-Mail: fiberop@weedinstrument.com www.weedinstrument.com Specifications subject to change without notice. Rev 1, Pub: 2C13/2C32-11-07