VMD Guide for MP-980 Cameras

Similar documents
VMD Guide for MP-980 Cameras

VMD Guide for V960 Series Cameras

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide

Warning: To reduce a risk of fire or electric shock, do not expose this product to rain or moisture.

CompleteView SightLogix Sensor Setup Manual. CompleteView Version 4.7.1

Milestone XProtect Alarm Matrix Integration 1.0

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Please use authentic SATA hard drive, USB device and battery.

Welcome to MultiSight TM Vision Sensor Hands-On Lab

Avigilon Control Center 5 System Integration Guide

i-vu CCN 4.0 Owner s Guide

Ademco Vista Alarm Panel

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

Chapter. Configuring Cisco VSMS. Versions 5.1, 6.0. Configuring Third-Party Programs. SightLogix, Inc

Milestone XProtect Alarm Matrix Integration 1.0

Avigilon Control Center 5 System Integration Guide

Configuring Alarm Rule for Video Analytics Detector

Intelligent Video Analysis

Chapter. Configuring OnSSI NetDVMS. OnSSI NetDVMS versions 5.x through 6.5g. OnSSI NetDVMS Ocularis. Configuring Third-Party Programs

NeXT is a powerful stand-alone application running fully embedded in network cameras to perform an intelligent video surveillance for ATM devices.

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

OnGuard 7.1 Resolved Issues

CompleteView Alarm Client User Manual. CompleteView Version 4.6.1

Security Management System - Configuring Video Analytics

Integration with Mobotix Q24

User Manual. Dryer Controller M720

System Galaxy Quick Guide

Honeywell Enterprise Alpha version 5.86

MODEL V5160MUX 16-CHANNEL DIGITAL COLOR MULTIPLEXER

Recording Server PRELOADED

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

Integration Test Plan

Table of Contents. i-vu CCN Standard 4.2

1 Introduction Data transmission Compatibility IPS Analytics configuration... 3

User s Guide. Manual P/N Rev No. 2, 04/11

Trident User s Manual

Monitoring Operator Guide. Access Control Manager Software Version

STATE-OF-THE-ART FLAME, SMOKE AND INTRUSION VIDEO DETECTION TECHNOLOGY FIRE DETECTION AND VIDEO SURVEILLANCE

MPL3115A2 Sensor Toolbox User s Guide

FCD-wire Contents. List of Figures

ProStar 325 UV-Vis Detector

Simplex Panel Interface Guide

D-Link Central Management System

Supervisor Standard Edition

Monitor Alarms and Events

Appendix 3 Thermostats

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Avigilon Control Center 5 System Integration Guide

TOUCH PANEL INSTRUCTION MANUAL

Bosch TCU Integration Module Administrator's Guide

Gallagher System Integrations

Alarm Manager Plug-in

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

Configuration and Operation Manual for the Unipos

HERCULES 6 GRAPHICS SYSTEM

Architectural and Engineering Specification for a Security Management System. StarNet 2

BeneVision Central Monitoring System. Quick Reference Guide

Mobile App & Customer Web Portal. Quick Start Guide

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS

Midco SmartHOME TM Subscriber Portal User Guide. Jamaica 6.0

Avigilon Control Center 5 System Integration Guide. with STENTOFON AlphaCom. INT-STENTOFON-C-Rev1

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-36 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

Dryer Controller M720

Getting Started with Live Exceptions

User Manual. Software. PGuard II. Dallmeier electronic GmbH. DK GB / Rev /

TITLE RS20i Atmos & DTS:X Decoder Card (H693) Setup

Evaluation of Biomek FX SV 96 Method Gripper Moves

3D_ISS. Integrated Software System. User Guide Manual

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM

Operator's Handbook. Release 3. Fire Alarm Control Panel, BS-310 / 320 / Operator Panel BS-330. System Program Version 3.8.0

Raytec Avigilon Integration User Guide Integrating Raytec Network Illuminators with Avigilon Control Center Document Revision 2.0

Security Management System Configuring TCP-IP MODBUS Inputs

SETTING UP DSC INTEGRATION THROUGH ENTRAPASS

Browser Compatibility Update

HikCentral Web Client. User Manual

Integration Guide AXIS Camera Station and AXIS A8004-VE

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we

BOSCH GV4 Alarm Panel

OnGuard 7.2 Resolved Issues

Moxa Proactive Monitoring User s Manual

Chapter. Configuring Genetec Omnicast. Version 4.7 SR1. Configuring Third-Party Programs. SightLogix, Inc

Configuring IndigoVision Control Center. Configuring IndigoVision Control Center

rvm4c Installation Guide Remote Video Module

Honeywell Total Connect Remote Services

NextGen Home Security. Quick Reference Guide

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)

Fridge-tag 2 E OPERATION MANUAL ENGLISH PAGE 1-36 MODE D EMPLOI FRANCAIS PAGE with internal sensor

Smoke Detector and Siren. Manual

Patriot Systems Limited

Alarms Updated 03/26/2018

D3D Wi-Fi GSM Smart Alarm System -User Manual

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

PowerRouter application guideline

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

Transcription:

Configuration Guide XX206-10-01 VMD Guide for MP-980 Cameras Vicon Industries Inc., 89 Arkay Drive, Hauppauge, New York 11788 Tel: 631-952-2288 Fax: 631-951-2288 Toll Free: 800-645-9116 24-Hour Technical Support: 800-34-VICON (800-348-4266) UK: 44/(0) 1489-566300 Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free or perform precisely as described in the documentation. This system has not been designed to be used in life-critical situations and must not be used for this purpose. www.vicon-security.com Document Number: 8009-8206-10-01 Product specifications subject to change without notice. Issued: 1211 Copyright 2011 Vicon Industries Inc. All rights reserved.

Guide for Configuring and Using Video Motion Detection 1 Guide for Configuring and Using Video Motion Detection on I-Onyx MP-980DN Series Cameras This guide provides a step-by-step procedure for using the Video Motion Detection feature of I-Onyx MP-980 cameras with ViconNet (version 5.6 and higher). It assumes an understanding of ViconNet and the cameras. Refer to the ViconNet and camera manuals for detailed information. The Video Motion Detection (VMD) feature activates an alarm due to activity beyond specified sensitivities in preconfigured regions of interest (ROIs) in the camera view area. Since initial setup and configuration of I-Onyx MP-980 cameras are not done through VNSetup software but through a Web Browser interface, the support for a VMD alarm event is generated by the camera and is defined and setup in the camera configuration. The VMD message is sent from the camera and received in ViconNet as an external alarm; it can then be used to trigger a macro. These cameras support both open (video stream between the camera and PC must be established and kept open in order for alarm to be received) and closed (camera is capable of sending the alarm even if a video stream is not open) stream VMD. Cameras that support a closed stream of video for VMD do not have to be running to trigger the alarm. However, each camera that has VMD configured must be connected to be viewed or recorded at least once before the alarm mechanism will work. In this case, a handshake macro must be configured to create this handshake and to ensure that the alarm will be re-activated and triggered even if the NVR reboots, shuts down or fails. The closed stream method saves storage but does not provide the prealarm option. An open stream video should be used if constant recording, prealarm or control of fps is required.

2 Guide for Configuring and Using Video Motion Detection Camera Configuration This section explains how to configure the Vicon I-Onyx MP-980 cameras for video motion detection (VMD feature) to work properly. The ViconNet system and the camera should be setup and connected before beginning this procedure. I-Onyx MP-980 Series Megapixel Cameras These I-Onyx cameras can be configured with either open or closed stream video. Review the requirements for the particular installation to determine which way is best. Additionally, these cameras provide for using multiplestream configuration, which may be required for certain installations. From the Configuration screen, select the Audio and video screen. Select Motion Detection Select Video Stream

Guide for Configuring and Using Video Motion Detection 3 Depending on the required operation, it may be necessary to configure more than one video stream. If recording is to be set to start only when motion is detected, it is only necessary to set up one stream with the desired parameters. However, if it is required to have the system record at a certain resolution and quality all the time (usually lower one), and switch to a different resolution and quality on motion (usually a higher one), at least two streams need to be configured with the different parameters. Note that when the ViconNet macro is set up, it distinguishes between the different streams from the camera by resolution; that is why each stream must be set to a different resolution. Refer to the camera manual for details. Note that when using MPEG-4 compression, there may be up to a 2 second delay between the alarm and the stream change. Video Stream 1 Resolution Video Stream 2 Resolution From the Configuration screen, select Motion detection. The following screen displays. Note that motion detection is set up only on the stream that will be associated with the VMD macro. Check to Enable Motion Detection Motion Window

4 Guide for Configuring and Using Video Motion Detection Check Enable motion detection. Click on to add a new window; up to three (3) windows can exist simultaneously. Use the mouse to click, hold, and drag the window frame to resize or the title bar to move the window. Click on the x at the upper righthand corner to delete the window. Click. A graphic bar rises or falls depending on the image variation. A green bar means the image variation is under monitoring level and a red bar means the image variation is over monitoring level. When the bar goes red, the detected window is also outlined in red. On the video, the monitored window is hidden but the red frame shows when motion is detected. Enter the parameters to define each window. "Window Name" text shows at the top of the window. Sensitivity sets the acceptable amount of change in motion before an alarm. Percentage sets the space ratio of moving objects in the monitoring window. Higher sensitivity and smaller percentage allow easier motion detection. Refer to the section on Creating Macros for the next step.

Guide for Configuring and Using Video Motion Detection 5 Configuring ViconNet Creating Macros Examples of VMD Alarms Example 1 Example 2 Example 3 The next step in supporting VMD alarms is to create a macro that defines what happens when motion occurs. After the macro is defined it is then linked to the external alarm of the NVR/Workstation. Remember that recording is not available on a Workstation, only on an NVR or DVR. Below are three examples. A camera is recorded at a low fps and switches to a higher fps upon motion. Requires two video streams set up in the camera The NVR is set to record the camera at Q7 on one video stream (lowest resolution stream) The camera VMD is set to generate an alarm on motion On the NVR, the VMD alarm trigger runs a 2 nd macro that will record at Q1 (on the highest resolution video stream) for a predetermined time Note: There is no higher resolution pre-alarm option for this; any recording prior to the VMD alarm is at the low resolution. A camera is recorded, and display is triggered by motion. The NVR is set to record the camera at desired resolution and fps The camera VMD is set to generate an alarm on motion On the NVR, the VMD alarm trigger runs a 2 nd macro that will start display of the camera on the desired Workstation A camera is only recorded by motion. A Workstation is viewing the camera as needed The camera VMD is set to generate an alarm on motion On the NVR, the VMD alarm trigger runs a macro that will trigger recording on the NVR Note: There is no pre-alarm at all in this case.

6 Guide for Configuring and Using Video Motion Detection When VMD is on a camera that is recording (open stream configuration), the recording macro is created first. The VMD trigger is a second macro. To create a macro: From the ViconNet Main window, click. The Setup Site Selection window displays. Select the site (NVR/Workstation) for which the macro is being defined and click. The System Settings window displays. Click. The Macro Editor window displays. In examples 1 and 2, the camera is recording before the VMD trigger, so a recording macro must be created. Click. The middle section of the screen displays. Add Macro Commands List Select Camera Fill in a logical name for the macro and a description if desired. Select the camera that is being configured from the device list. Select the first command from the Commands list; in the example, select Record. The bottom portion of the screen displays. Fill in all pertinent fields for the command. The MP-980 cameras will not allow fps selection and the user will define the quality requested (Q1 for highest available stream, Q8 for lowest). In example no. 1, define recording at Q7 being the lower resolution stream and for example no.2, recording at Q1 for the higher resolution stream; remember this must correspond with the camera stream setting. A macro can have multiple commands; repeat command selection if required for the macro. The macro executes in the command order. Click and then.

Guide for Configuring and Using Video Motion Detection 7 A second macro is now configured to tell the NVR what to do in the case of a VMD alarm; in the examples, command the NVR to record the camera at a different quality or display video from the camera. The third example does not require the first macro; this alarm macro instructs it to record the camera upon a motion alarm. Follow the previous steps to create the macro. To setup example 1: From the Commands list, select Record. Select the higher recording stream (Q1) for the Record command. To setup example 2: From the Commands list, select Display. This allows the video to display on the local Workstation/NVR. If it is required that the video display on a different unit, create another macro using with the Send Alarm command and select the Destination of the video. To setup example 3: From the Commands list, select Record. Select the recording stream for the Record command (usually Q1). From the device list, select. This links the camera to the external alarm and uses the camera name as shown in the alarm for the macro to work (eliminating the need to specify which camera is for this macro). Note: This method has one limitation. A macro that runs as a result of ANY alarm will always trigger the same response (for example display the alarmed camera) and does not allow launching different macros for different alarms. If there is a requirement to do so, you will need to utilize ViconNet Events Management (see ViconNet manual). A camera that is running closed video requires a handshake macro to assure the system recognizes the alarm. Running this macro on the camera for 15 seconds every hour will assure that the VMD will be triggered even if the NVR restarted or lost communication to the camera at some point. To create the handshake macro: Follow the previous steps to create the macro. Configure a macro to record the camera every hour for 10 seconds so that the system maintains recognition of the camera.

8 Guide for Configuring and Using Video Motion Detection Configuring the Macro Scheduler Next, a schedule needs to be created to run the 24/7 recording macro and/or the handshake macro according to your requirements, including on which days of the week, as well as a start time and end time for each day. Refer to the Creating Schedules section in the Configuring ViconNet chapter in the latest ViconNet manual, XX113. From the ViconNet Main window, click. The Setup Site Selection window displays. Select the site name (NVR/Workstation) for which the alarm is to be defined and click. The System Settings window displays. Click.. The Scheduler Settings window is displayed, showing any currently defined schedules in the system. Click. The Scheduler Settings window is enabled.

Guide for Configuring and Using Video Motion Detection 9 From the Macro dropdown list, select the macro for which you want to create a schedule. The defined macro description is displayed automatically in the Macro Description field. Select the days of the week that you want the macro to run from the Sunday - Saturday checkboxes. To select a specific date for the macro to run, click in the Specific dates area. A calendar is displayed. Select the date/s required by clicking in the calendar. For the recording and handshake macros, every day of the week should be checked. In the Active From and To fields, define the start and end time (in HH:MM:SS format) for the macro to run on each of the selected days, as follows: Select the required time segment and then use the up/down arrows to scroll to the required value, OR select the required time segment and then use the keyboard to type in a numerical value. If the Active From and To times are the same, the schedule will be for a 24-hour period; this is used for the recording and handshake macros. In the Options area, select a run option for the macro; for the 24/7 recording (examples 1 and 2), select Continuously; for the handshake macro, select Launch Every and select 1 hour. Click.

10 Guide for Configuring and Using Video Motion Detection Configuring the External Alarm The final step is to configure the external alarm on the Workstation/NVR to activate the macro upon receiving the VMD alarm. Each NVR/Workstation has 1 default External Alarm that can be edited to receive the VMD alarm from the camera and execute the macro. To define the external alarm: From the ViconNet Main window, click. The Setup Site Selection window displays. Select the site name (NVR/Workstation that has the ability to receive alarms) for which the alarm is to be defined and click. The System Settings window displays. Click. The Active Detectors & Associated Macros window displays. Alarm Display Settings Add Detector Edit Detector Select the alarm display settings at the top of the screen. From the displayed list, select External Alarm. Click. The Alarm Setup Wizard window displays. Note: If the External Alarm has been previously deleted from the NVR/Workstation, click. From the Alarm Setup Wizard, select External Alarm and that follow.. Proceed with the steps for Edit Detector

Guide for Configuring and Using Video Motion Detection 11 Define the time schedule for the macro in the Alarm Activity Time area; the default is 24 hours a day, 7 days a week. Press. From this Alarm Setup Wizard, select the macro previously created to be activated when the motion alarm occurs. Linked to related devices should say Yes. If the macro was not created, or needs to be changed, it can be done by clicking. Follow the procedure for creating a macro. Click. Select Macro Yes displays The external alarm setup link is displayed in the list in the Active Detectors & Associated Macros window. Click Show Details to see complete information on alarm setup.

Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York 11788 631-952-2288 800-645-9116 Fax: 631-951-2288 Vicon Europe Headquarters Brunel Way Fareham, PO15 5TX United Kingdom +44 (0) 1489 566300 Fax: +44 (0) 1489 566322 Vicon Germany Kornstieg 3 D-24537 Neumuenster Phone: +49 (0) 4321 8790 Fax: +49 (0) 4321 879 97 Far East Office Unit 5, 17/F, Metropole Square 2 On Yiu Street, Shatin New Territories, Hong Kong (852) 2145-7118 Fax: (852) 2145-7117 Internet Address: www.vicon-security.com