ALUMINUM. ELEVATED. CEDAR RENDITIONS DESIGN SERIES INSTALLATION INSTRUCTIONS

Similar documents
Siding Installation Guide

INSTALLATION MANUAL. for HardieReveal2.0 Panel System Version 2.0. Effective July Technical Services:

CEILINGS BACKSPLASHES WALLS PROJECTS INSTALLATION GUIDE.

INSTALLATION INSTRUCTIONS

Installation Guide Maibec Regular Siding

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

WARNING. Before installing your siding, inspect the delivered wood. All installed material shall be considered accepted.

SA-20WB-HPE SA-20WB-LPE SA-20WT-HPE SA-20WT-LPE SA-30WT-HPE SA-30WT-LPE SA-20WB-HP SA-20WB-LP SA-20WT-HP SA-20WT-LP SA-30WT-HP SA-30WT-LP

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

IdealFILM. Do-It-Yourself Installation Manual

SonusClip Installation for walls or ceilings on wood or steel framing. Installation Instructions for Wall & Ceilings

Snap Trim and Clips JANUARY, 2017 EC INDEX

Transforming Institutional buildings for the next 100 years. The Log Program & Plans

EccoTone Acoustic Wood Panels Installation Manual

Ventis Direct Vent. Installation Instructions

BDM Direct Vent systems are for use with direct vent gas fired appliances.

PRODUCT CATALOG. GUTTER SUPPLIES Residential and Commercial. Largest Selection, Competitive Pricing, Highest Quality and Unmatched Customer Service

Regupol SonusClip Installation Guide for Walls or Ceilings with Wood or Steel Framing

SECTION GYPSUM PLASTER

INSTALLATION INSTRUCTIONS FOR. ProTek RIGID VINYL WALLCOVERING

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

Installation Guide. Beveled Stainless Steel Sinks K-3388 K-3387 K-3389 K A

James Hardie Exterior Wall Drainage Requirements

Installation Instructions

Always check local building codes before doing any construction work.

Gardian W51. Approvals

Installation Guide. Pedicure Spa D K-163, K-1006, K-1011, K-1012

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

Dual Function SMART VENT. Superior Flood Protection and Natural Air Ventilation SMART VENT - Model:

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

Dimensions: 39 1/2" w x 22" D x 35.5 H. kk25 installation. Things you might need for the installation: vessel sink,

AuthenticDECORATIVE METAL WALLS & CEILINGS

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

Installation Instructions

kk21 installation Kk21-WF21 Things you might need for the installation: vessel sink,

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

Microwave Oven. IMPORTANT SAFETY INSTRUCTION Never operate the oven when it is empty or without the glass turntable.


CLEANCUT CONVERTIBLE INSTALLATION GUIDE

Wall Mount Electric Fireplace

Installation Instructions

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

INSTALLATION INSTRUCTIONS

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

In-Wall Slide-out OEM INSTALLATION MANUAL. In-Wall Slide-out OEM Installation Manual

Horizontal Blinds Installation Instructions

AirScape Solar Attic Fan. Installation Manual SAF10R SAF25R

ELECTRIC FLAT PANEL FIREPLACE HEATER

Tankless Water Heater Direct Vent Sweet Termination Installation Instructions

Experienced Worker Assessment Blueprint Building and Home Maintenance Services

CableReady

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual.

GENIE CLIP TYPE RST. Resilient Sound Isolation Clip INSTALLATION INSTRUCTIONS

Things you might need for the installation: vessel sink, plumber's putty(home depot), liquid nails(home depot), Bucket silicone caulk(home depot),

Kold Locker Walk in Standard walk in stocked for IMMEDIATE SHIPMENT

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS

CLEANCUT ULTRA-LOW INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS

Turn colour into curb appeal.

SEPARATED COMBUSTION WARNING

Installation and Maintenance Instructions

ELECTRIC FLAT PANEL FIREPLACE HEATER

Royal Shutters, Mounts & Vents. Every little detail is huge.

INSTALLATION GUIDE NZ AU GB IE SG F

4. A 2 X4 knee wall, if insulated, should be to what R value? 5. The clearance between insulation and a furnace vent should be:

Things you might need for the installation: vessel sink, plumber's putty(home depot), liquid nails(home depot), Bucket silicone caulk(home depot),

Installation Instructions

The IceFree Eave System

SEPARATED COMBUSTION. General WARNING

Suntrek's Solar Pool Heating Installation Guide

Revolutionizing The Cable Molding Industry

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

74xx K. St. sample actual insp.w/photos, Edina, MN 5543x

KITCHEN INSTALLATION GUIDE

Unrivaled Underbar Features

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

STC 46 3-Sided Paired Frame (Double Rabbet Only)

venetian plaster exclusivewallcovering Low VOC LEED IEQ 4.2 CAL 1350 & CHPS certified VINYL WALLCOVERING Fire classification

Pedimat Installation Instructions

Frequently Asked Heater Questions Plus

F o o d S e r v i c e

EUTECTIC EC-10DV Series

Installation Instructions

In-Wall Loudspeakers C 280, C 265, and C 260. Ceiling Loudspeakers C 85, C 70, and C 65

INSTALLATION. For more information on this product or to order samples call or visit our website at builddirect.com.

University of Illinois at Urbana-Champaign Small Homes Council-Building Research Council COUNCIL NOTES. ::s >

American Panel. Walk-In Installation & Maintenance Manual

DES MOINES PUBLIC SCHOOLS MADISON WALK-IN COOLER/FREEZER PROJECT. 806 E. Hoffman Street Des Moines, IA ADDENDUM NO.

mason What It Means To Be Green VINYL WALLCOVERING High Durability (Fed. Spec. CCC-W-408D) Fire Testing Type II

Vertical Blinds. Step by Step Installation Instructions

GE Monogram. Installation. Instructions. Stainless Steel Bottom Mount Built-In Refrigerators. Models ZICS36N RH ZICS36N LH

EN RaychemRIM2StandardInstallationManual IM H /16 1

Frequently Asked Band Heater Questions Plus

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

Ultimate Flip Lever Astragal Cut Down Instructions

Technical Specifications Section 1

Installation Instructions

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

Transcription:

ALUMINUM. ELEVATED. CEDAR RENDITIONS DESIGN SERIES INSTALLATION INSTRUCTIONS

CEDAR RENDITIONS BY ROYAL 2 INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS Important Notes...5 Wall Preparation...7 Installation Accessories...11 Installation Panels...14

WHAT IS CEDAR RENDITIONS DESIGN SERIES? Cedar Renditions is where the versatile, sturdy durability of thicker gauge aluminum siding meets wider board, contemporary wood aesthetics and streamlined looks. DESIGN SERIES FEATURES: 6" Siding, modern streamlined profile Thicker gauge siding Easy to install with a drop-in interlock system Seamless overlapping notch to achieve coverage greater than 12ft Residential and light commercial applications Affordable price Leed compliant and 100% recyclable 25-year prorated limited warranty Compatible with the rest of Cedar renditions line of products INSTALLATION INSTRUCTIONS 4

IMPORTANT NOTES STORAGE AND TRANSPORTATION When transporting the siding to a job site, make certain to keep the cartons flat and supported along their entire length. At the job site, take the following precautions when storing the product: Store the cartons on a flat surface and support the entire length of the cartons. Keep the cartons dry. Do not store the cartons in stacks more than 6 cartons high. To prevent damage to the product, it is best for the cartons to be carried by two people. 5 INSTALLATION INSTRUCTIONS

TOOLS AND EQUIPMENT Hammer Miter saw with 80T or equivalent non-ferrous metal cutting blade Utility Knife Tape measure Pencil Chalk line Level Circular saw (80T or equivalent non-ferrous metal cutting blade) Snips Square Safety gear FASTENERS When choosing a fastener for aluminum cladding products, first check with local building code officials for possible requirements. In lieu of special code requirements, Royal Building products recommends the following; Nails: Nails should be a length to be able to penetrate no less than 3/4" (19mm) into framing or furring. Nails must be aluminum or stainless steel and should have a head of at least 5/16" (7.9mm ) in diameter and a shank of 1/8" (3.2mm). INSTALLATION INSTRUCTIONS 6

WALL PREPARATION WATER-RESISTIVE BARRIER Royal aluminum siding is an exterior cladding, not a water resistive barrier, and are designed to allow the material underneath to breathe. This factor provides a supplemental rain screen that reduces the amount of water that reaches an underlying waterresistive barrier. Water-resistive barrier systems often consist of a combination of exterior cladding such as aluminum siding, flashed wall opening and penetrations, water-resistive material and sheathing. The level of water resistance required is determined by the applicable building code, the structure and the climate. NEW CONSTRUCTION Aluminum siding must be installed over rigid sheathing. The siding should never be applied directly to studs without sheathing. There may also be other installation requirements (furring strips, etc.) prior to the installation of the siding. Consult local building codes for specific requirements. 7 INSTALLATION INSTRUCTIONS

RESIDING A flat level wall surface is necessary for proper installation of the siding. If re-siding over existing wood siding, a wall leveling foam or furring strips can be used. Consult local building codes for specific requirements. The wall surface should be as dry as possible during the installation process. It is important to nail down loose boards of existing siding, and replace any rotten ones. Scrape off loose caulk and re-caulk around doors, windows and other areas to resist moisture penetration. Remove all protrusions such as gutters, downspouts and light fixtures. INSTALLATION INSTRUCTIONS 8

MASONRY WALLS Apply minimum 1" X 3" (19mm X 64mm) furring strips at 12" to 16" (304mm-406mm). Furring should be installed along all trim areas such as windows, doors under overhangs, corners, etc., and along the bottom of the walls. To achieve a more solid feel, fill the areas between the furring strips with foam board as defined by building code. IMPORTANT: In some areas, additional strapping may be required when installing cladding. The following descriptions are typical for those applications. Furring or strapping must be applied to all walls receiving the siding 1" X 3" (19mm-64m). For horizontal siding, the furring should be installed vertically at approximately 16" (406m) intervals. For vertical siding, the furring should be installed horizontally at approximately 12" (304m) intervals. Frame all walls, windows doors, etc. with the furring strips. Wood furring strips 16" o.c. for horizontal siding Wood furring strips 12" o.c. for vertical siding 9 INSTALLATION INSTRUCTIONS

CUTTING CAUTION: Safety glasses should be worn at all times during the cutting process. Miter Saw with 80T or equivalent non-ferrous metal Cutting Blade Tin Snips Utility Knife INSTALLATION INSTRUCTIONS 10

INSTALLATION ACCESSORIES INSTALLATION ACCESSORIES STRIKE A CHALK LINE Determine the lowest corner of the walls to be sided. Measure up to establish the point that will represent the top of the bottom J channel. Using a level, strike a chalk line from this point, around all walls to be sided. (In some situations, it may be possible to measure down from overhangs equally, to establish this line.) 11 INSTALLATION INSTRUCTIONS

OUTSIDE AND INSIDE CORNERS Make sure posts are plumb. Strike a chalk line if necessary. Secure the post by placing fasteners at 8" to 12" (203mm-305mm) intervals. Allow 3/8" (9.5mm) gap at the bottom if the post is to be placed over concrete, decking, etc. If more than one length of corner post is required, remove 3/4" (19mm) from the nail hem and receiving channel of the upper post and overlap the post by 3/8" (9.5mm). For inside corners, two J channels back to back can be used or one J channel against the siding of the adjacent wall. INSIDE CORNER TOP VIEW PANEL FLASHING OR INSTALLATION INSTRUCTIONS 12

TRIMMING AROUND DOORS Install Starter strip at the bottom of the wall aligning the top of the channel with the chalk line and the top of the wall. Fasten the channel every 8" to 12" (203mm- 305mm). Install J channel around windows, doors, and all openings as shown below, fastening every 8" to 12" (203mm- 305mm) beginning with the bottom piece, then sides, then top. 13 INSTALLATION INSTRUCTIONS

INSTALLATION PANELS Install panels to avoid overlap being exposed to higher traffic areas whenever possible. Place the first panel into the J channel and corner post. Position the panel so there s a 1/8" (3.2mm) gap in the corner between the end of the panel and the inside of the corner. This gap should accommodate expansion and contraction as temperatures changes Fasten the panel in the center of the nail slots, leaving 1/32" (.8mm) between the fastener and the panel to allow the panel to expand and contract. Space fasteners at 16" (406mm) maximum. Install the remainder of the course allowing 1/8" (3.2mm) between the nailing hems of the panels to allow for expansion and contraction of the panels through temperature changes. INSTALLATION PANELS INSTALLATION INSTRUCTIONS 14

Install subsequent courses making sure to randomly spread out the seams trying not to have any laps closer than 24" (610mm) to each other to make them less noticeable. Seams should never repeat unless separated by three courses. When measuring the height for panel cuts under windows, doors, etc., subtract 1/2" from the measurement to allow for engagement of the lock when installing the panel(s). To add support for the window cut under the window, use the piece removed from the panel by flipping the piece around and securing it inside the J channel. The cut edge of the panel can then be inserted between the support piece and the channel. 15 INSTALLATION INSTRUCTIONS

Use the same method used for under windows to determine the height of the final top course of panels. To add support for the top course cut, use the piece removed from the panel by flipping the piece around and securing it inside the J channel. Run a continuous bead of silicone caulk along the cut on the back side of the panel. The cut edge of the panel can then be inserted between the support piece and the channel. INSTALLATION INSTRUCTIONS 16

1.855.ROYAL85 ROYALBUILDINGPRODUCTS.COM 2018 ROYAL BUILDING PRODUCTS