B. Section Identification for Fire Suppression Piping and Equipment.

Similar documents
SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

SECTION SPRINKLER SYSTEMS

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

Lucy s Pizza 100% CD Specification 06/22/2018

Mercury Plastics New Building February TABLE OF CONTENTS

FIRE SUPPRESSION SPRINKLER SYSTEM

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

TABLE OF CONTENTS

DIVISION 21: FIRE SUPPRESSION

PART 1 - GENERAL SECTION FIRE PROTECTION BASIC MATERIALS AND METHODS

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

SECTION WET-PIPE SPRINKLER SYSTEMS

Gas Station & C Store SECTION CWM Job No

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

SECTION DRY-PIPE SPRINKLER SYSTEMS

New Rigby Elementary School February TABLE OF CONTENTS

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

Kenworth Sales Co. - North Las Vegas, Nevada November TABLE OF CONTENTS

DIVISION 21: FIRE SUPPRESSION

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

SECTION WET-PIPE SPRINKLER SYSTEMS

Port of St Helens SIA Aircraft Hanger Scappoose, OR

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

WET AUTOMATIC FIRE SPRINKLER SYSTEMS

Microfast quick response Fusible element hsw sprinkler

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

SECTION SPRINKLER SYSTEMS

SPRINKLERS TABLE OF CONTENTS

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT LEAD FREE SPRINKLER VK4570 (K4.9) TECHNICAL DATA

Standard Spray concealed horizontal sidewall sprinkler VK481

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

SECTION FIRE-SUPPRESSION STANDPIPES

standard response fusible link sidewall sprinkler VK112 (K5.6)

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK480 TECHNICAL DATA

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5

SECTION WET FIRE SPRINKLER SYSTEMS

freedom residential concealed pendent sprinkler VK488 (K3.0)

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

freedom residential concealed pendent lead free sprinkler

freedom residential flush pendent sprinkler vk476 (K4.9)

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

B. Related Sections: The following Sections contain requirements that relate to this Section.

ADDENDUM NO. 3 March 19, 2018

micromatic Standard response Horizontal Sidewall sprinkler

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

SECTION ELECTRIC-DRIVEN, FIRE PUMPS

STANDARD/quick. Sprinkler 42o. August 8, 2011

Quick response concealed horizontal sidewall sprinkler VK481

DIVISION 21: FIRE SUPPRESSION WATER BASED FIRE SUPRESSION SYSTEMS

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

standard response Fusible Link Upright sprinkler VK204 (K8.0)

Page 1 of 7. Form No. F_ Rev Replaces Form No. F_ Rev 17.1 (added 205deg version)

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

TECHNICAL DATA OBSOLETE

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

Environmental Health & Safety

quick response horizontal sidewall sprinkler vk360 (K8.0)

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

E x t E N d e d Co v e r ag e S p r i n k l e r s. Office Buildings Hotels Hospitals Libraries. High-Piled Storage Big-Box Retailing

SECTION WET-PIPE SPRINKLER SYSTEMS

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2

freedom residential concealed pendent sprinkler vk474 (K5.8)

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers

DIVISION 21: FIRE SUPPRESSION

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

Transcription:

SECTION 211300 - FIRE SUPPRESSION SPRINKLERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.2 RELATED REQUIREMENTS A. Section 210500 - Common Work Results for Fire Suppression: Pipe, fittings, and valves. B. Section 210553 - Identification for Fire Suppression Piping and Equipment. C. Section 220548 - Vibration and Seismic Controls for Plumbing Piping and Equipment. D. Section 220553 - Identification for Plumbing Piping and Equipment. 1.3 REFERENCE STANDARDS A. ICC-ES AC01 - Acceptance Criteria for Expansion Anchors in Masonry Elements; 2009. B. ICC-ES AC106 - Acceptance Criteria for Predrilled Fasteners (Screw Anchors) in Masonry Elements; 2006. C. ICC-ES AC193 - Acceptance Criteria for Mechanical Anchors in Concrete Elements; 2010. D. ICC-ES AC308 - Acceptance Criteria for Post-Installed Adhesive Anchors in Concrete Elements; 2009. E. NFPA 13 - Standard for the Installation of Sprinkler Systems; National Fire Protection Association; 2010. F. UL (FPED) - Fire Protection Equipment Directory; Underwriters Laboratories Inc.; current edition. 1.4 SUBMITTALS A. See Section 013000 - Administrative Requirements, for submittal procedures. B. Product Data: Provide data on sprinklers, valves, and specialties, including manufacturers catalog information. Submit performance ratings, rough-in details, weights, support requirements, and piping connections. FIRE SUPPRESSION SPRINKLERS 211300-1

C. Shop Drawings: 1. Indicate hydraulic calculations, detailed pipe layout, hangers and supports, sprinklers, components and accessories. Indicate system controls. D. Project Record Documents: Record actual locations of sprinklers and deviations of piping from drawings. Indicate drain and test locations. E. Operation and Maintenance Data: Include components of system, servicing requirements, record drawings, inspection data, replacement part numbers and availability, and location and numbers of service depot. F. Maintenance Materials: Furnish the following for Owner's use in maintenance of project. 1. See Section 016000 - Product Requirements, for additional provisions. 2. Extra Sprinklers: Type and size matching those installed, in quantity required by referenced NFPA design and installation standard. 3. Sprinkler Wrenches: For each sprinkler type. 1.5 QUALITY ASSURANCE A. Conform to UL requirements. B. Designer Qualifications: Design system under direct supervision of a Professional Engineer experienced in design of this type of work and licensed in the State in which the Project is located. C. Equipment and Components: Provide products that bear UL label or marking. D. Products Requiring Electrical Connection: Listed and classified by Underwriters Laboratories Inc., as suitable for the purpose specified and indicated. 1.6 DELIVERY, STORAGE, AND HANDLING A. Store products in shipping containers and maintain in place until installation. Provide temporary inlet and outlet caps. Maintain caps in place until installation. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Sprinklers, Valves, and Equipment: 1. Tyco Fire Suppression & Building Products: www.tyco-fire.com. 2. Viking Corporation: www.vikinggroupinc.com. 3. Substitutions: See Section 016000 - Product Requirements. FIRE SUPPRESSION SPRINKLERS 211300-2

2.2 SPRINKLER SYSTEM A. Sprinkler System: Provide coverage for entire building. B. Occupancy: Ordinary hazard, Group 2; comply with NFPA 13. C. Water Supply: Determine volume and pressure from water flow test data. D. Interface system with building control system. E. Provide fire department connections where indicated. F. Storage Cabinet for Spare Sprinklers and Tools: Steel, located adjacent to alarm valve. G. Pipe Hanger Fasteners: Attach hangers to structure using appropriate fasteners, as follows: 1. Concrete Wedge Expansion Anchors: Complying with ICC-ES AC193. 2. Masonry Wedge Expansion Anchors: Complying with ICC-ES AC01. 3. Concrete Screw Type Anchors: Complying with ICC-ES AC193. 4. Masonry Screw Type Anchors: Complying with ICC-ES AC106. 5. Concrete Adhesive Type Achors: Compying with ICC-ES AC308. 6. Other Types: As required. 2.3 SPRINKLERS A. Suspended Ceiling Type: Semi-recessed pendant type with matching push on escutcheon plate. 3. Finish: Chrome plated. 4. Escutcheon Plate Finish: Chrome plated. B. Exposed Area Type: Pendant type with guard. C. Exposed Area Type: Pendant upright type with guard. 3. Finish: Brass. 4. Fusible Link: Fusible solder link type temperature rated for specific area hazard. FIRE SUPPRESSION SPRINKLERS 211300-3

D. Sidewall Type: Semi-recessed horizontal sidewall type with matching push on escutcheon plate. 3. Finish: Brass. 4. Escutcheon Plate Finish: Brass. E. Dry Sprinklers: Recessed pendant type with matching push on estucheon plate. 3. Finish: Brass. 4. Cover Plate Finish: Brass. F. Storage Sprinklers: Pendant type with guard. G. Storage Sprinklers: Concealed upright type with guard. 1. Response Type: Standard. 3. Finish: Chrome plated. 4. Shield Finish: Chrome. H. Guards: Finish to match sprinkler finish. I. Spray Nozzles: Brass with solid cone discharge, 30 degrees of arc with blow-off dust cap. 1. Finish: Brass. 2.4 PIPING SPECIALTIES A. Dry Pipe Sprinkler Alarm Valve: Check type valve with divided seat ring, rubber faced clapper to automatically actuate water motor alarm, with accelerator; with test and drain valve. FIRE SUPPRESSION SPRINKLERS 211300-4

B. Water Motor Alarm: Hydraulically operated impeller type alarm with aluminum alloy chrome plated gong and motor housing, nylon bearings, and inlet strainer. C. Water Flow Switch: Vane type switch for mounting horizontal or vertical, with two contacts; rated 10 amp at 125 volt AC and 2.5 amp at 24 volt DC. D. Fire Department Connections: 1. Type: Flush mounted wall type with brass finish. 2. Outlets: Two way with thread size to suit fire department hardware; threaded dust cap and chain of matching material and finish. 3. Drain: 3/4 inch (19 mm) automatic drip, outside. 4. Label: "Sprinkler - Fire Department Connection". 2.5 AIR COMPRESSOR A. Compressor: Single unit, electric motor driven, motor, motor starter, safety valves, check valves, air maintenance device incorporating electric pressure switch and unloader valve. PART 3 EXECUTION 3.1 INSTALLATION A. Install in accordance with referenced NFPA design and installation standard. B. Install equipment in accordance with manufacturer's instructions. C. Provide approved double check valve assembly at sprinkler system water source connection. D. Locate fire department connection with sufficient clearance from walls, obstructions, or adjacent siamese connectors to allow full swing of fire department wrench handle. E. Locate outside alarm gong on building wall as indicated. F. Place pipe runs to minimize obstruction to other work. G. Place piping in concealed spaces above finished ceilings. H. Center sprinklers in two directions in ceiling tile and provide piping offsets as required. I. Apply masking tape or paper cover to ensure concealed sprinklers, cover plates, and sprinkler escutcheons do not receive field paint finish. Remove after painting. Replace painted sprinklers. J. Install and connect to existing fire pump system. FIRE SUPPRESSION SPRINKLERS 211300-5

K. Install air compressor on vibration isolators. Refer to Section 220548. L. Flush entire piping system of foreign matter. M. Install guards on sprinklers where indicated. N. Hydrostatically test entire system. O. Require test be witnessed by Fire Marshal. 3.2 INTERFACE WITH OTHER PRODUCTS A. Ensure required devices are installed and connected as required to fire alarm system. 3.3 SCHEDULES A. System Hazard Areas: 1. Offices: Light Hazard. 2. Repair Bays: Ordinary Hazard, Group 2. 3. Warehouse: Ordinary Hazard, Group 2. END OF SECTION FIRE SUPPRESSION SPRINKLERS 211300-6