Operating Instructions for Rotor flow Indicator. Model: DKF

Similar documents
Operating Instructions for Air-Flow Monitor. Model: LPS-P

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

OPTIBAR DP 7060 Supplementary Instructions

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

PEPPERL+FUCHS GmbH

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Vacuum Hose Reel 881 Ex


OPTIBAR P 1010/2010 C Supplementary instructions

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

OPTIWAVE X500 Supplementary Instructions

Translation of the assembly instructions with operating instructions and technical appendix

Implementation of ATEX Guidelines

Technical Data. Dimensions

EtherCAT Box Modules (EPxxxx-xxxx)

Safety instructions VEGAPULS 64

METALDRIVE ATEX Couplings

Instruction manual 640 Securiterre

Dual certification! Air handling units for potentially explosive atmospheres

INSTRUCTION MANUAL (ATEX / IECEx)

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Multipoint temperature sensor

EQUIPMENT INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

Flameproof Manual Call Points

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

ATM Lighting sp. z o.o

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

TRASCO ATEX Couplings

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

VSD AND SS DRIVING ATEX MOTORS February 2014

ANNEX GD-CERT-EX-EN SIT

Our. Heaters. for your Projects

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Temperature Sensor TRG Original Installation Instructions English

LSM PUMPER Sigenvej 7 DK 9760 Vrå Tlf.: Fax USERS GUIDE FOR LSM PUMPS TYPE

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Operating Instructions

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

SMK 22 SMK SMK SMK 22-82

Ultrasonic Level Measurement nivopuls FDU 10 S

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Technical Data. Dimensions

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Technical Data. Dimensions

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Druck DPI 705/DPI 705 IS Series

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

VERSAFLOW VORTEX Supplementary instructions

Operating Instructions

Exp, pressurized systems

MANUAL Oil Level Sensor

High pressure cleaning heads cleanliness all around

EUROPUMP ATEX Guideline Part II

Betriebsanleitung / Operation manual. Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD

OO Measuring range from bar rel. OO Large selection of pressure sensors. OO Automatic sensor recognition

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

PROTECT SRB 200EXi-1A

Valve Manufacturers Association of America

Annubar Flowmeter Series

ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information

Explosion protection Marijan Gorše, dipl. ing.

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

AE PV Heating Element. Screwing in Heating Unit. Installation Manual. Version 01.6

HazLoc Essential Guides:

AC 4 & 5 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY ELECTRICAL CONNECTIONS INSTALLATION

L / -014L / -015L

Instruction Manual, Rotary Spray Heads

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Certificate of Conformity

AZN ATEX INSTALLATION AND MAINTENANCE

standards: standards:

INSTRUCTION MANUAL (ATEX / IECEx)

Instruction Manual Captive Air Level Control. Model NLP

Operating Instructions for Reka Hot-Melt Glue Applicators

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Transcription:

Operating Instructions for Rotor flow Indicator Model: DKF

1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Mechanical Connection... 4 5.1 Before installation... 4 6. Technical Information... 4 7. Order Codes... 5 8. Dimensions... 5 9. ATEX - Declaration of the Manufacturer... 6 9.1 General... 6 9.2 Areas of use... 6 9.3 Evaluation... 6 Manufactured and sold by: Kobold Messring GmbH Nordring 22-24 D-65719 Hofheim Tel.: +49(0)6192-2990 Fax: +49(0)6192-23398 E-Mail: info.de@kobold.com Internet: www.kobold.com page 2 DKF K01/1115

2. Note Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health & Safety and prevention of accidents. When used in machines, the measuring unit should be used only when the machines fulfil the EC-machine guidelines. as per PED 2014/68/EU In acc. with Article 4 Paragraph (3), "Sound Engineering Practice", of the PED 2014/68/EU no CE mark. Diagram 8, Pipe, Group 1 dangerous fluids 3. Instrument Inspection Instruments are inspected before shipping and sent out in perfect condition. Should damage to a device be visible, we recommend a thorough inspection of the delivery packaging. In case of damage, please inform your parcel service / forwarding agent immediately, since they are responsible for damages during transit. Scope of delivery: The standard delivery includes: Rotor Flow Indicator: Model: DKF Operating Instructions 4. Regulation Use Any use of the Rotor Flow Indicator, model: DKF, which exceeds the manufacturer s specifications, may invalidate its warranty. Therefore, any resulting damage is not the responsibility of the manufacturer. The user assumes all risk for such usage. DKF K01/1115 page 3

5. Mechanical Connection 5.1 Before installation Remove all packing materials and transport restraints and ensure that no such materials remain in the device. Make sure that the maximum operating pressure and temperature of the device are not exceeded. (see section 6.Technical Information..) Install the flow indicator in the piping system, ensuring that the piping is rigidly supported at the inlet and outlet of the unit with pipe clamps Ensure that the piping is aligned with the inlet and outlet fittings and the no piping induced stresses are exerted in the indicator. This stress can result in damage to the device during system operation Protect the device from external damage. Avoid pressure surges within the indicator chamber, such as those arising from fast start up/shut off of flow or pulsating flow. If possible, after completing the mechanical installation, check the threaded connection between the device and the piping for leakage immediately. 6. Technical Information Maximum Temperature: 120 C Maximumg Pressure: 6 bar page 4 DKF K01/1115

7. Order Codes Order data (Example: DKF-1101H R06) Indication range Model Connection l/min P water (bar)* DKF-11.. DKF-21.. G-thread NPT-thread 0.14-2 1 DKF-1101H.. DKF-2101H.. R06 N06 0.25-7 1 DKF-1102H.. DKF-2102H.. R08 N08 0.45-18 1 DKF-1103H.. DKF-2103H.. R10 N10 0.6-28 1 DKF-1104H.. DKF-2104H.. R15 N15 1-61 1 DKF-1105H.. DKF-2105H.. R20 N20 1.8-83 1 DKF-1106H.. DKF-2106H.. R25 N25 * max. flow 8. Dimensions Model p max t max G NPT L1 L A B Weight kg DKF-..01H 6 bar 120 C G 1/8 1/8 8 56 41 50 0.3 DKF-..02H 6 bar 120 C G 1/4 1/4 10 56 41 50 0.28 DKF-..03H 6 bar 120 C G 3/8 3/8 14 73 53 67 0.57 DKF-..04H 6 bar 120 C G 1/2 1/2 14 73 53 67 0.54 DKF-..05H 6 bar 120 C G 3/4 3/4 16 109 72 94 1.41 DKF-..06H 6 bar 120 C G 1 1 18 109 72 94 1.30 DKF K01/1115 page 5

9. ATEX - Declaration of the Manufacturer 9.1 General Risk analysis report pursuant to EN 13463 (positive list) for use in category 2 Explosion Risk Area was done. When used properly, and being a piece of mechanical equipment, the rotor flow indicator Type DKF-x1****** does not have its own potential source of ignition; it is not assigned an ID in the sense of the ATEX Directive. 9.2 Areas of use The units can be used as follows: In the Zone 2 (Gas-Ex, Cat. 3G) into explosion group of IIA, IIB and IIC In the Zone 22 (Dust-Ex, Category 3D) at non-conductive dusts with a minimum igniting energy of > 3 mj In the Zone 1 (Gas-Ex, Cat. 2G) into explosion group of IIA, IIB and IIC In the Zone 21 (Dust-Ex, Category 2D) at non-conductive dusts with a minimum igniting energy of > 3 mj In normal use, the rotor flow indicators are completely filled with medium. Zone 2 or Zone 1 conditions may prevail for a short time. 9.3 Evaluation Adherence to EN 13463, Parts 1 to 8 (Mechanical Explosion Prevention) When used properly, the rotor flow indicator does not have its own potential source of ignition as per the conditions of Categories 2 and 3. It does however fulfil the following requirements: The manufacturer has subjected all exposed parts of the device to the impact and environmental strain tests pursuant to EN 13463-1. When installed, the device must be protected against external energy impact or measures should be taken to take into account any possible zone violations in the system. The outer casing of the device is made of brass or stainless steel and borosilicate glass; there are no light metal parts. Hofheim, 12. Nov. 2015 H. Peters M. Wenzel General Manager Proxy Holder page 6 DKF K01/1115