The IceFree Eave System

Similar documents
INSTALLATIONGUIDE. HotSeam TM Overview ICE ROOF

HotValley TM

HotEdge Rail TM

EN RaychemRIM2StandardInstallationManual IM H /16 1

HotEdge Rail TM

Gardian W51. Approvals

HotFlashing. HotFlashing TM

ROOF ICE MELT (RIM) SYSTEM

Roof and Gutter De-Icing

ROOF ICE MELT (RIM2) SYSTEM

Radiant Edge LT TM Ice Melt System Installation and Operation Guide Version 1.4

Self-regulating Roof Heat and Gutter Trace Cable

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM

Self-regulating Roof Heat Cable

Toll Free:

Freezer Frost Heave Prevention

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

COMMERCIAL & RESIDENTIAL MARKETS U.S. ELECTRICAL

Principle of Operation:

IceStop System INSTALLATION AND OPERATION MANUAL FOR ROOF AND GUTTER DE-ICING SYSTEMS

XL-Trace System Application and Design Guide

INSTALL & USERS GUIDE

PLSRR Heat Trace Cable Data Sheet

IceStop System Installation and Operation Manual

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Operating Guidelines for Your Roof and Gutter Ice Dam Prevention System

DISTRIBUTOR GUIDE FOR SELLING QUALITY TO CONTRACTORS

SAFETY & COMFORT FOR THE HOME RESIDENTIAL MARKET U.S. PLUMBING CANADA PLUMBING AND ELECTRICAL

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

Edge Melt Systems. Roof Ice Prevention Perfected Product Catalog. PO Box Delafield WI Version 2.

Commercial and Residential Self-Regulating Heating Products

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

RF0809 SERVICE FLASH. Frost Build Up On Upright Freezer Door Dyke SERVICE FLASH BRAND MODEL/SERIAL # CAUSE

McDONALD S 30 ROOF ELEMENT

Installation Guide Soil, Asphalt & Concrete De-icing Heating Ribbons

Toll Free:

Phoenix Thermal Supply

RX1200 ROOF AND GUTTER DE-ICING CONTROLLER INSTALLATION AND OPERATION MANUAL

SEASONAL MAINTENANCE SCHEDULE

Toll Free:

Solatube Daylight Dimmer Installation Instructions

BDM Direct Vent systems are for use with direct vent gas fired appliances.

Heating cable solutions for temperature-related problems

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

Sidel Combi-Combi Therm & CO2 Counter Installation Guide

ADDITIONAL INFORMATION

C Electrical Connection Kit

Technology for human beings that is, compatible with nature, creating permanent HEAT TRACING Dreams that can greatly improve the quality of life,

ALUMINUM. ELEVATED. CEDAR RENDITIONS DESIGN SERIES INSTALLATION INSTRUCTIONS

DS-5C RAIN/SNOW SENSOR CONTROLLER INSTALLATION INSTRUCTIONS

Phone (516) Fax (516) web site

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

NELSON HEAT TRACING SYSTEMS

THERMAL MANAGEMENT SOLUTIONS

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

MODEL GF PRO AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

The feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn.

Model GIT 4 Gutter Snow and Ice Melting Control

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

C A Heating Cable Gland Kit

High Performance Heater with More Efficient Heat

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

SAFETY INFORMATION AND WARNINGS

De-icing & Snow-melting Systems by SST Group for a Safe Urban Environment

PROPERTY REINSPECTION REPORT

H908 WinterGard Plug-in Power Connection Kit with End Seal

FTC-HST WARNING: CAUTION:

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

F1202 TRACE HEATING. Road & Ramp

The Roof Ice Prevention Leader. Deicing Systems Catalog PO Box Delafield, WI

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

RayClic Connection System

MEGAWAT * HIGH DENSITY CARTRIDGE HEATERS

PART GENERAL 1.01 SECTION INCLUDES

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

The Technology Leader. Deicing Systems Catalog PO Box Delafield, WI

CQS POWER VENT. General. Venting Requirements. Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH

The most advanced Supply Box System from Oatey - the choice of plumbing professionals.

Home Maintenance Schedule

Tube Clamp Submittal Information Revision A: July 25, 2013

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

AFFORDABLE CANADIAN HOME INSPECTIONS

Contents ATTACHING CONTROLS WARRANTY TOOLS... 5 ELEMENT ELEMENT POWER SUPPLY COVER HEATING ELEMENTS...

Coil Heaters, Mini Coil Heaters, Formable/Flexible Tubular Heaters

Instructions Apply For Model PHTT-6P-KFC. Panel Shelf Is Removed to install warming drawers

NELSON HEAT TRACING SYSTEMS

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

Installation Instructions for. OmniFount

Installation Instructions PRO SERIES

Transcription:

Material Recycled Aluminum Alloy 6063 Temper - T5 Sizes. Sold in 5 panel extrusions. IceFree 8 Eave Panel (for eaves up to 12 deep) IceFree 12 Eave Panel (for eaves up to 18 deep) IceFree 18 Eave Panel (for eaves up to 24 deep) IceFree Valley Panel for valleys, chimneys, crickets etc IceFree Utility Panel a larger version of the valley panel Components Aluminum Alloy Snap Loc Top, Aluminum Alloy Base Panel, Aluminum Alloy Transition Panel Colors 7 Standard Powder Coating Colors are available Heat Source the 8 Eave, 12 Eave, Valley, Utility Panel Systems utilize 2 feet of Heat Trace per foot of panel. The 18 Eave Panel System will utilize three feet of cable per foot. Products are designed for 11mm or 14 mm commercial grade heat cables, mineral insulated (MI) cable or 3/8 Radiant PEX tubing *Recommended Commercial Grade- Self Regulating Heat Cable. IceFree Eave Panel fit below shingles, provide a drip edge into the gutter, and eliminate ice & snow in the roof s freeze zone. Aluminum Extrusion Profiles (5 lengths) IceFree 8 Eave Panel for eaves up to 12 deep) Optional Items Ambient and/or Moisture Sensor Controllers, Self regulating heat trace for gutters and downspouts Electrical Requirements N.E.C. 426-28 requires 30 ma Ground Fault circuit protection for snow and ice melting applications Specifications IceFree Eave Panel s simple integrated drip edge and colormatched cover is designed to eliminate icicles, ice dams, and snow at the roof s edge. Engineered Roof Deicing innovative roof snow and ice elimination systems are attractive and cost eective. They ensure that the building s owner will not have the frustration, property damage, and costs associated with water damage, caused by the inability of the buildings roof to properly drain water during winter months. Engineered Roof Deicing s revolutionary roof de-icing systems will extend your roof life and reduce the destructive situations that snow and ice can inflict on any roof. Mounting Eave panels are installed with sealant & roofing screws. Screws and sealant may be replaced by 3M VHB Adhesive Tape, TAM- PRO Flashing Cement or Rainbuster 14000 Silicone. The lip of the eave panel fits below the shingles, cedar shake, corrugated metal roof panels, or slate roof panels, facilitation proper moisture drainage o the roof structure. IceFree 12 Eave Panel for eaves up to 18 deep IceFree 18 Eave Panel for eaves up to 24 deep IceFree Valley Panel for Valleys IceFree Utility Panel for Chimneys, Valleys & Below Stairs

Selecting a panel length The Eave Panel melts ice in the freeze zone at the roof s eave. The Valley Panel melts ice in the freeze zone at the roof s valley. IceFree Eave 12 Panel 18 Deep Eave The size of the eave freeze area determines the size of the eave panel. Panel heats 70% of valley length The lower 70% length of valleys is the typical freeze zone. This area needs heat protection in cold climates. IceFree 8 Eave Panel (for eaves up to 12 deep) IceFree 12 Eave Panel (for eaves up to 18 deep) IceFree 18 Eave Panel (for eaves up to 24 deep) IceFree Valley Panel (for valleys, chimneys, crickets etc) IceFree Utility Panel (a larger version of the valley panel) Number of feet of heat cable allowed per circuit breaker The 8 Eave, 12 Eave, Valley, Utility Panel Systems utilize 2 feet of Heat Trace per foot of panel. The 18 Eave Panel System will utilize three feet of cable per foot. Pay strict attention to the ambient start up temperature, circuit size and load requirement. Start-up temperature 15 A Circuit Breaker 20 A Circuit Breaker 30 A Circuit Breaker 40 A* Circuit Breaker @ 120 volts 32 F (0 C) 100 (30) 135 (41) 200 (61m) 20 F ( 7 C) 95 (29m) 125 (38m) 185 (56m) 200 (61m)* 0 F ( 18 C) 80 (24m) 100 (30m) 155 (47m) 200 (61m)* @ 208 volts 32 F (0 C) 190 (58) 250 (76) 380 (116m) 20 F ( 7 C) 180 (55m) 235 (72m) 355 (108m) 380 (116m)* 0 F ( 18 C) 145 (44m) 195 (59m) 290 (88m) 380 (116m)* @ 240 volts 32 F (0 C) 200 (61m) 265 (81m) 400 (122m) 20 F ( 7 C) 190 (58m) 250 (76m) 370 (113m) 400 (122m)* 0 F ( 18 C) 155 (47m) 205 (62m) 305 (93m) 400 (122m)* @ 277 volts 32 F (0 C) 215 (66m) 290 (88m) 415 (126m) * Only FTC-P power connection kits may be used with 40-A circuits. Bus Wires 16 AWG nickel-plated copper Braid/Outer 20 F ( 7 C) 200 (61m) 265 (81m) 400 (122m) 415 (126m)* 0 F ( 18 C) 165 (50m) 225 (69m) 330 (101m) 415 (126m)*

Heat Source Options How to select the correct heat channel All of our products can incorporate dierent types of heat sources, such as, 11-14 mm self regulating heat cable, Mineral Insulated Cable and Hydronic / Radiant Tubing. Engineered Roof De-icing's technically advanced aluminum alloy extrusions are manufactured with specific sized channels for specific sized heat cables. If multiple sized channels are available, only fill one size on each side of the panel with the correct cable or tubing. 3/8 PEX tubing 14mm 11mm cable cable Note: All products manufactured by Engineered Roof Deicing incorporate the same or similar superior internal configuration as the systems shown here. The same installation parameters with regards to channels vs. heat source apply to all of the other panel system products manufactured and sold by Engineered Roof Deicing. This picture shows the correct cable in the correct channel. The separation between the snap-loc top and base unit are designed and manufactured within tight tolerances. This separation enables proper connectivity between the thermal panels and the heat source, enabling direct heat transfer or direct thermal conductivity to occur between the heat source and the base and top aluminum alloy panels. Many quality self regulating cables are designed to be installed within the smaller of the two channels. This channel, or slot, is sized for approximately 11mm heat cable. Many quality self regulating cables are designed to be installed within the larger of the two channels or slots. space is sized for approximately 14mm heating cables. 3/8" Oxygen Barrier Tubing or PEX tubing is designed to be installed within the round channel, slot or hole. This.5 inch hole can accommodate other heat sources as becomes necessary. www.

Drawings 8 Eave Panel for eaves up to 12 deep 2.44 0.73 5.50 12 Eave Panel for eaves up to 18 deep 6.40 3.70 0.08 1.20 0.38 0.38 2.40 13.00 18 Eave Panel for eaves up to 24 deep 1.20 12.5 0.70 3.70 0.08 0.38 0.38 2.40 19.34 3 Valley Panel for Valleys 0.73 2.86 6 Utility Panel for valleys, chimneys, crickets etc 0.70 6.08

3 Valley Panel for valleys, chimneys, crickets etc 0.73 2.86 Panel Mounting Panel Mating Sold in 5 or 10 lengths 0.50 Screw Hole Placement Every 2 (24 ) (Not Pre-drilled) Leave 0.50 between panels. Cover With Cladding the entire length of Alloy Panel Heat Cable

6 Utility Panel for valleys, chimneys, crickets etc The IceFree Eave System 6.08 0.70 0.50 Leave 0.50 between panels. Cover With Cladding Cover Entire length of Aluminum Alloy Cladding Cover Loop cable at end cap End Cap (optional item) 5.00 Sold in 5 or 10 lengths Screw hole placement every 24 on center (not pre-drilled)

Placement of Ice & Water Shield, Flashing and Roofing Materials Angle Mounting Roofing material (shingles, panels, etc) Heat Cable Ice and water shield Roof Support Utility Panel Valley Flashing Surface Mounting Roofing material (shingles, panels, etc) Flashing Ice and water shield Roof Support Surface Mounting for Rubber Roof Manufacturer s recommended adhesive or cement Non-slip powder coat Ice-stop Heat Cable Roofing Material

Example Cable Run for Utility Panels 3.00 Gap Between Panels for Cable Exit Junction, Covered by Cladding Cover Power Source Control Box 0.50 Gap Between Panels, Covered Cladding Cover To Gutters, or other panels Heat Cable End Termination Power Source Control Box

Double-Valley Panel 3.00 2.00 3.00 6.00 12.00 Screw hole placement every 24 on center (Not pre-drilled) Roofing material (shingles, panels, etc) Double Valley Panel Assembly Roofing Material Ice & Water Shield Roofing Material

Flat Roof Panel 6.7 5.8 6.7 0.726 2.297 19.2 Each addition of a center panel adds 5.8 Sold in 5 or 10 lengths Screw Hole Placement (not pre-drilled) Heat Cable Insert Panels to increase length Each addition of a center panel adds 5.8

Flat Roof Panel Installation Surface Mounting Roofing material (shingles, panels, etc) Flashing Ice and water shield Roof Support Surface Mounting for Rubber Roof Manufacturer s recommended adhesive or cement Non-slip powder coat (optional) Ice-stop Heat Cable Roofing Material