K 100 (W) DES. Disinfectant measurement. Applications. Description. Intuitive and simple menu Safety by password function. Disinfection.

Similar documents
Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning

, ClO 2. K 100 Cl 2. , SCl 2 , O 2 , O 3 , H 2. O 2 K 100 W Cl 2. Manual

Steam and Water Analysers

Inductive. Range. S410/IND Electrodeless Conductivity Sensors

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

Two-Channel Gas Controller

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Toxic Gas Detection. Model F12. Toxic Gas Detection

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Process Alarm Module RTA 421

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Chlorine / Chlorine Dioxide Measurement liquisys S CCM 223 / 253

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

LCF Touch Modbus Datasheet Application Security Advice Caution

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Model D12-IR. Digital Gas Transmitter...

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET

General Specifications

Multi-Gas-Controller MGC2

Danfoss gas detection units

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

UDC 700 Universal Digital Controllers and Indicator Specifications

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Gas Detection System TOX ALARM DG2000-Garage

Turbimax CUE21 / CUE22

Mark 25 Ultrapure Water Conductivity Analyzer

Dräger Polytron 8000 Stationary gas detector (EC)

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

CTT8 TEMPERATURE MONITOR DEVICE

F4 Process Controller Installation and Operation Guide

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Model D12. Digital Gas Transmitter

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

MO n : 12JMC rév A

Gas Controller Module GC-06

Danfoss gas detection Controller unit

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Product Catalog and Technical Specifications for DCW-Units

Stand Alone DYNAGARD SP Operation Manual

Dissolved Oxygen Measurement liquisys M COM 223 / 253

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

Warranty Registration

Table of Contents SECTION PAGE

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

Danfoss gas detection unit Type GD Heavy Duty

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Multiview Monitor / Controller

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Speed and Frequency Seite 1 von 7

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

Concise catalogue Water-Industry

Poolcontrol DYNAMICS. Operating Instructions for users

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

portable gas analyser

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

Water Technologies. V600 Disinfection Controller

Model Q45P/R. ph/orp Monitor...

Danfoss gas detection units

TPF Series Ozone Generators

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Oxygen (O2) Single-Point Gas Detection System

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

Model Q45P/R. ph/orp Monitor...

Dissolved Oxygen Analyzers

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Dual Input ph/orp Analyzer

Series Temperature Controller Instruction Sheet

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

ETO 2 - Controller for ice and snow melting

/8 DIN Level Indicator

JENCO ELECTRONICS, LTD.

ß-Aerosolmonitor FHT 59 C

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Data Sheet. >>AMTAX inter 2

RTD TEMPERATURE SENSING SYSTEM

User Manual. PolyGard Single Point Controller SPC3-11XX. Single Point Gas Controller Serial Number _E_1007. May 2009

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Refrigerated Incubator Model and Operating Instructions

Operator's Manual Dielman Rock Island Industrial Dr. St. Louis, MO Tel:(314)

GMA200-MW4. User Manual. Gas detection controller for wall mounting

User Guide. DATUM L150 Panel-Mounted Universal Level Indicator A1. ABB Instrumentation

SECTION Free/Available Chlorine Analysis System

Transcription:

Intuitive and simple menu Safety by password function Applications Disinfection Cooling water Process Water K 100 W DES Drinking Water / Beverages Description The instruments of the K100 series are high-quality single-channel measuring and control instruments to measure disinfectants, ph/orp, conductivity or gas. Each instrument has one measuring input and a temperature input. You can select automatic or manual temperature compensation. All instruments contain a PI controller with two set points. Data can be read out via 0/4-20mA output or optionally via serial interface. The K100 provides various safety features: A freely adjustable start delay prevents wrong dosing after power failure, and the controller is shut off automatically in a low-water situation. You can activate dosage check, a function that stops the controller and issues an alarm if prolonged dosing with 100% does not result in reaching the set point or the p range, possibly due to damaged feed lines. Two limits can be defined, to issue an alarm if the measurement exceeds the limits. K100 instruments for the measurement of free Chlorine, Chlorine dioxide, Ozone, and Hydrogen peroxide are optionally available with our automatic sensor cleaning ASR.

Particular characteristics Power supply: 24/117/230 V AC Scaleable, glavanically isolated 0/4.. 20 ma output Illuminated two-line LC-Display for measred value and temperature 2 PI controller with separate set points Automatic or manual Temperature compensation Invertible alarm output, permanent or pulse contact 2 limit values with delay, assigned to alarm relay Dosage check Display of relay status and error messages Safety by password function Option: serial interface RS 485 - KUNTZE protocol Option: ASR - automatische Sondenreinigung

Interface diagram Technical data Measuring parameter Free Chlorine Chlorine Dioxide Ozone Hydrogen Peroxide 0.. 4.00 mg/l 0.. 20.00 mg/l 0.. 4.00 mg/l 0.. 4.00 mg/l 0.. 30.0 mg/l

Input characteristics Temperature measuring range Temperature coefficient Digital input Ambient conditions -30.. +140 C (display range) 0.. 8 %/K adjustable 1 as controller stop by external contact ph-range free Chlorine: ph 6.. 8, konstant Chlorine dioxide, Ozone, Peroxide: ph 6.. 9 Total Chlorine: ph 4.. 12 Flow ~30.. 200 l/h Min. conductivity >150 µs/cm, with ASR > 200 µs/cm Temperature 0.. 50 C Output characteristics Alarm relay Output signal Serial interface 1 potential-free N/O contact, max. 250 V, 6 A, 550 VA 1 x 0/4.. 20 ma (scaleable, galvanically isolated) Load max. 500 Ohm Registration range Scaleable within measuring range Option: RS 485 - Kuntze protocol Baud rate 9600 Baud Data format 8 bit Power supply Line voltage Power consumption 24 / 117 / 230 VAC, +6 / -10 %, 40.. 60 Hz 10 VA Ambient conditions Temperature Humidity Protection class Storage -20.. +65 C Operation 0.. +50 C max. 90% rh at40 C (non condensing) Wall mounted IP 65 Panel mounted IP 54 (front) IP 30 (housing) Controller Control response Relay Start delay Controller stop On/off controller (adjustable hysteresis) P/PI controller (pulse-pause, pulse-frequency or continuous output) 2 relays each with potential-free N/O contact, max. 250 V, 6 A, 550 VA 0.. 200 sec until controller active digital input Certificates and approvals CE-Symbol EMV/EMC The product meets the requirements of the harmonized European standards and complies with the legal requirements of the EC directives. EN 61326 class B, 2004/108/EG

Design configuration Material Dimensions Panel mounted housing: Noryl; Wall mounted hosuing: ABS Panel mounted housing: 90x90x116 mm; Wall mounted housing: 165x160x85 mm Panel mounted housing: 92x92x140 mm panel mounted housing: 0,75 kg; wall mounted housing: 0,95 kg Mounting dimension Weight Mechanical drawing K 100 W

K 100 Storage version Article number 100200K type/configuration K 100 Cl2 100250K K 100 ClO2 100400K K 100 O3 100450K K 100 H2O2 105200K K 100 W Cl2 105250K K 100 W ClO2 105400K K 100 W O3 105450K K 100 W H2O2 Description Measuring and control instrument for Free Chlorine (0-4 mg/l); panel Measuring and control instrument for Chlorine Dioxide (0-4 mg/l); panel Measuring and control instrument for Ozone (0-4 mg/l); panel mounted; 230 V AC Measuring and control instrument for Hydrogen Peroxide (0-30 mg/l); panel Measuring and control instrument for Free Chlorine (0-4 mg/l); wall Measuring and control instrument for Chlorine Dioxide (0-4 mg/l); wall Measuring and control instrument for Ozone (0-4 mg/l); wall mounted; 230 V AC Measuring and control instrument for Hydrogen Peroxide (0-30 mg/l); wall

Accessories accessories RS 485 module KUNTZE protocol Serial interface for K 100 instruments. With this card all instrument data can be read out. The used protocol is a for Kuntze developed Bus protocol. ASR - automatic sensor cleaning The automatic sensor cleaning is a patented highly efficient process to clean electrode surfaces. During the cleaning process, Hydrogen and Oxygen are produced at the electrode surfaces, blasting away even persistent coatings. Additionally, Oxygen oxidizes organic coatings, and Hydrogen reduces organic and inorganic substances, especially iron and manganese oxides. Excess gas recombines to water and do not interfere with the measurement or the process. For further information check www.automatische-sondenreinigung.de S-341 Data Logger The Bus data logger S-341 receives, displays and stores measuring data for up to 10 Kuntze instruments (K100 and K400). Test Plug DES With the test plug you can check the function and connection of our disinfection measurement - not for Total Chlorine measurement (not TCl). Radon FM The Radon photometer is used for measurement of Chlorine, Chlorine Dioxide and Ozone. Accurate and consistent results are obtained quickly. The instrument uses well proven tablet reagents with a long shelf-life. hand-held units Powered by TCPDF (www.tcpdf.org)