B. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.

Similar documents
A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

SECTION INTERIOR LIGHTING

SECTION INTERIOR LIGHTING

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Lighting. Basis of Design

CL001 >400 Watt lamp basecase, up to 600 Watt replacement fixture $95.00 Fixture

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 26 ELECTRICAL

Advances in Non-Residential Lighting Technologies

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Lighting. Basis of Design

Lighting Existing Conditions and Design Criteria Report EXECUTIVE SUMMARY

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

LED RETROFIT SOLUTIONS

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

Ivalo Lumaris LED Linear Lighting

PSO Business Rebates Retrofit Lighting Technical Requirements

SECTION LIGHTING

WINDSOR FOREST HIGH SCHOOL HVAC REPLACEMENT ADDENDUM #2 SAVANNAH CHATHAM COUNTY PUBLIC SCHOOL SYSTEM FEBRUARY 18, 2016

LED RETROFIT CONVERSION KITS

Pacific Gas and Electric Company Energy Efficiency Rebates for Your Business. Lighting Rebate Catalog Saving energy for a brighter future

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

EcoSystem H-Series 347 V~ Ballast Overview

Overview. The Reading Room

LED Linear Design Highlights

PRODUCT DATA SHEET LIGHTING PRODUCTS

Lighting Existing Conditions and Design Criteria Report Brian Regan Ltg./Elect. Virginia Historical Society 10/8/03

Ivalo Lumaris LED Linear Lighting

Ivalo Lumaris LED Linear Lighting

SECTION INTERIOR LIGHTING

LED RETROFIT CONVERSION KITS

A. This Section includes the following lighting control devices:

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

Ivalo Lumaris. LED Linear Lighting. High quality, even lines of illumination and guaranteed LED compatibility with 1% Lutron dimming IVALO COLLECTION

2. Lighting fixtures mounted on exterior building surfaces.

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming

Lighting Existing Conditions and Design Criteria Report

Commercial & Industrial Lighting LED Retrofits for Troffers

LED LUMINAIRE SERIES LED Luminaire Series Improves Your Illumination Systems

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

DHL-LP-LED Low Profile LED Linear High/Low Bay

Instructions for completing the NE&C LIGHTING Rebate Worksheet

Hawthorn Building. Penn State Altoona Campus Altoona, PA. Walter Nichols. Lighting/Electrical Option Faculty Advisor: Dr.

2017 Lighting Incentive

Advanced Lighting For Office

Thesis Proposal. Brian Regan The Virginia Historical Society Building West Wing Addition RICHMOND, VIRGINIA

Related Sections: TBD. Effective Date: January 1, 2016

EcoSystem H-Series Ballasts

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

Catalog Number. Notes

New LED Product Offerings

LED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

Hi-lume 3D Overview. Fluorescent Dimming Ballasts

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

Jennifer Mers. Rio Hondo Library and Learning Resource Center. Executive Summary. General Building. Lighting/Electrical Option

Incentive & Measure Specifications

SECTION INTERIOR LIGHTING

Lighting Control Strategies. to meet code requirements save energy and improve building performance

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

LED FIXTURE CATALOG. Shining light into the future

A. This Section includes the following lighting control devices:

InvestSmart Business Energy Upgrades Lighting Equipment Catalog 01/01/2018

DIMMING 0-10V Continuous

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Eligible Prescriptive Measures List:

Lobby Lighting Design

Emery County Senior Center Green River 06/07

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

Step Lighting. For indoor and outdoor, stair and pathway applications. Juno Lighting Group Juno Step Lighting 1

Richmond Building Energy Challenge. Project List - Lighting Technologies

EcoSystem H-Series Ballasts Overview

Are LED s ready for Prime Time?

High Performance Lighting. Terry Egnor Senior Consultant NBI

Lumination LED Luminaires

Electrical Systems. Electrical Plans. Electrical Plans. Essential to ensure. National Electrical Code (NES) Consider electrical needs.

SOL CROSS SECTION. PENDANT Spec Guide. Page 2 of Rev. JUNE18-1

LHBXD LED Linear High Bay

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

Excellence in LED Lighting. e-solis Edge Lit LED Panels.

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

LIGHTING CONTROLS

Education Title Solutions

RECESSED - WITH StepLens OPTION

IN2 Lighting Control Devices

2018 Commercial Lighting Retrofit Rebate Program

Steve Neimeister 8 October 2003 AE 481W AstroPower Headquarters Newark, Delaware Lighting/Electrical Option Consultant: M. Moeck

LED HIGH BAY LINEAR ECO SERIES

Non-Cutoff and Semi-Cutoff Wall Pack Primary Use and Edits to Outdoor Wall-Mounted Luminaire Primary Use

2018 Instant Lighting Rebates Product Catalog

TROFFER RETROFIT KIT (TRK)


P Archie. Incandescent NAME: PROJECT: Diameter: 5-3/4 Height: 8-3/4 Overall ht. w/stem: 75

Café DUSON- Overview

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

Lighting Existing Conditions and Design Criteria Report

WARRANTY LED ECO PANEL.

RECESSED T-Bar & Drywall

Transcription:

PART 1 GENERAL 1.01 Lighting design: A. Reference UAF Facilities Services Guidelines for Average Illumination Levels. B. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly. C. Design lighting levels in building with contiguous areas having average illumination levels differing by not more than a factor of 3. Intent is to provide even lighting throughout a building. D. Nightlights are not required or desired. E. Use 32 watt, T8 lamps for general illumination in classrooms, corridors, rest rooms and offices with ceilings 12 or less. F. Use 54 watt, T5 High Output lamps for high bay areas, and areas requiring unusually high levels of illumination. LED fixtures will be considered for areas requiring dimming and/or where lamp replacement is unusually difficult (ex over fixed seating or sloped floors). G. Use LEDs controlled by occupancy sensors in walk-in freezers and chillers. H. Provide light sensors to extinguish or dim lights when sufficient daylight is present. Coordinate with architects for appropriate windows and window treatments to promote daylight harvesting. I. Compact fluorescent luminaires: 1.02 Lamp life: 1. Shall not be used in new construction. 2. In remodels, compact fluorescent luminaires may be reused and renewed by replacing ballasts and lamps. A. Luminaires located at or less than 12 feet above floor: 36,000 hours or greater. B. Luminaires located greater than 12 feet above floor: 50,000 hours or greater. C. Luminaires located where lamp replacement is difficult (e.g.: auditoriums with anchored chairs and/or desks) lamps will have a minimum life of 50,000 hours. 26 51 00-1

1.03 Recessed linear luminaires at the junction of ceiling and walls (cove lights) are not allowed. Ceiling mounted wall wash fixtures are to be mounted no closer than 24 inches from the wall to allow for maintenance. 1.04 In public areas, such as corridors, do not use fixtures with louvers. Intent is to avoid irregular illumination of vertical surfaces ("cave" effect). Use louvered fixtures only where glare control is required. 1.05 Lenses/Louvers: A. Simple flat-shape lay-in or framed lenses are preferred. Lenses: Made of minimum ⅛ inch virgin acrylic, resistant to discoloration, with an A12 prismatic type diffuser pattern. B. Polystyrene lenses are prohibited. 1.06 Restroom Light control: A. Provide occupancy sensors. B. Where there are interior partitions, use ceiling mounted ultrasonic or dual technology sensors. C. Microphonic sensors will be considered. D. No sensor off switches to be accessible by users. 1.07 Occupancy / vacancy sensors: A. Ceiling mounted ultrasonic, infrared, or dual technology sensors except for small rooms such as partitionless restrooms and storage closets. B. Sensors mounted in corners of rooms are discouraged due to shadowing in coverage zones due to obstructions installed during and/or after construction. C. Occupancy sensors shall activate lighting immediately upon entry or sensor failure. D. Sensors shall have an electronic timer adjustable from 30 seconds to 30 minutes timeout and a separate adjustment for detection sensitivity. 1. Set sensor timers at 30 minutes for offices, public areas, storage areas, and restrooms. 2. Where LED luminaires are controlled, this requirement may be waived. 1.08 Directional luminaires such as can lights, decorative spotlights, task lights, or other type lighting with directed light: light emitting diode (LED) type luminaire and/or lamp. 26 51 00-2

1.09 Compact fluorescent lighting: A. Use replaceable lamps and permanent ballast. B. Lamp life to meet requirements stated elsewhere in this document. 1.10 Provide lighting in crawl spaces, pipe chases, and utilidors. A. When control switch is located outside these areas, provide a lighted switch or pilot light to indicate when lights are on. Label switch to indicate that the illuminated state of lighted switch or pilot light indicates whether area lights in illuminated area are on or off. B. Provide guards on all luminaires of this category where they are likely to come in contact to personnel or tools moving in the area. PART 2 PRODUCTS 2.01 Occupancy / vacancy sensors: Hubble, Wattstopper, Leviton, Lutron 2.02 All lamps containing mercury to be the low mercury, Eco, type. A. General illumination color temperature: 4100 Kelvin. 2.03 T8 and T5 linear fluorescent lamps: A. Lamps to be linear (straight) type. U-tubes, such as GE Moduline type, fluorescent lamps not acceptable. B. Lamp color temperature: 4100 Kelvin. C. Color Rendering Index (CRI) in excess of 85. D. 48 lamp wattage rating: 32 watts at a lamp current of 265 milliamperes or better. E. Lamp-life for T8 and T5 lamps shall be per requirements stated elsewhere in this document. F. Medium bi-pin. G. Programmed rapid start for T8 and T5 lamps. H. General Electric, Osram/Sylvania, or Phillips. 2.04 Compact fluorescent lamps: A. Lamps over 8 in length shall not be used. 26 51 00-3

B. Lamp color temperature shall be 4100 Kelvin. C. Color rendering index (CRI) in excess of 85. D. Minimum life of per requirements stated elsewhere in this document. E. General Electric, Osram/Sylvania, or Phillips. 2.05 Rapid Start Ballasts: A. Operating frequency greater than 20 khz with less than 2 percent flicker. B. Power factor of.95 nominal or higher. For F32T8 lamps power factor shall be 0.99 or higher. C. Total Harmonic Distortion (THD) less than 10%. D. Class A or better sound rating. E. Rapid Start Ballast: Maximum crest factor of 1.5. F. A ballast factor of 0.85 or better. G. A ballast efficacy factor greater than 2.54 for one F32T8 lamp, 1.44 for two F32T8 lamps, 0.93 for three F32T8 lamps, and 0.73 for four F32T8. H. Listed by UL and certified by CBM or CSA. I. Warranty for five (5) years against defective materials and workmanship for replacement parts and installation. J. High performance electronic ballasts: Osram\Sylvania, Advance, or Universal Lighting Technologies, Inc., Alternate Brand Request or Substitution Request required. K. Ballast is not harmed by operating with a failed or absent lamp. L. Ballast shall meet applicable FCC regulations. M. In general, wattage of the ballast and lamp system should not exceed the product of the nominal lamp wattage times the number of lamps used in a normal configuration. 2.06 Compact fluorescent ballasts: A. Operating frequency greater than 20 KHz. B. Power factor of 0.95 or higher. 26 51 00-4

C. THD less than 10%. D. Class sound rating. E. Maximum crest factor 1.5. F. A ballast factor of 0.85 or better. G. Listed or labeled by UL and certified by CBM or CSA. H. Ballast is not harmed by operating with a failed or absent lamp. I. Ballast shall meet applicable FCC regulations. J. High performance electronic ballasts: Osram\Sylvania, Advance, Universal Ballast, Alternate Brand Request or Substitution Request required. K. Ballast shall have lamp shutdown circuitry for end of lamp life protection. L. Warranty for five (5) years against defective materials and workmanship for replacement parts and installation. 2.07 High intensity discharge ballasts shall not be used. 2.08 LED luminaires: A. Driver life to exceed that of LED components. B. Automatic compensation for drift of LED color and lumen output. C. LED and driver components may be replaced without replacing fixture. 2.09 Luminaires with air return path through lamp cavity are not acceptable. PART 3 EXECUTION 3.01 Lighting switches shall not be reachable by persons within a shower, tub, sauna, or other similar enclosure. Locate switches outside the room or enclosed area, or at least 6 from a shower or tub. 3.02 Where occupancy sensors control lighting, install them ahead of lighting switches. Intent is to allow occupants to manually control their lighting. 3.03 Light switches illuminated in off position: A. At least one light switch at the entry(s) to mechanical and electrical rooms. 26 51 00-5

B. All light switches in utilidor spaces. 3.04 Not allowed: remote ballasts. 3.05 Provide for convenient luminaire cleaning, re-lamping, repair or replacement. A. Provide catwalks, overhead access, winches or lowering mechanisms for fixtures mounted in hazardous or other locations not readily accessible. B. Do not install lights where scaffolding must be built for maintenance. C. Lights in stairwells shall be: 1. Accessible from a 6 foot ladder and no higher than 10 feet above landing. 2. Not be over or near stair treads or railings to avoid personnel working off center of ladder. 3.06 Fluorescent lamps used with dimming ballast will be burned-in for 100 hours at 100% power prior to dimming. 3.07 Pendant mounted luminaires with cords: Use a similar attachment method for cord on all fixtures for uniformity of appearance. END OF SECTION 26 51 00-6