Room Air Conditioner SVC MANUAL(Exploded View)

Similar documents
Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

SVC Manual(Exploded View)

SVC Manual(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Single Zone Air Conditioner SVC MANUAL (Exploded View)

Wall Mounted Air Conditioner SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View)

LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static)

Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Ductless Split Systems Concealed Duct Heat Pumps

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Multi V Air Conditioner SVC MANUAL(Exploded View)

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

DESIGN & TECHNICAL MANUAL

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Ductless Split Systems Ceiling Cassette Heat Pumps

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

DESIGN & TECHNICAL MANUAL

Ductless Split Systems Wall-mounted, Multizone Heat Pump

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H)

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,

Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View)

2017 / 2018 RESIDENTIAL AIR CONDITIONERS

Multi V Air Conditioner SVC MANUAL(Exploded View)

Ducted inverter reverse cycle air conditioning

DESIGN & TECHNICAL MANUAL

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

DESIGN & TECHNICAL MANUAL

Multi V Air Conditioner SVC MANUAL(Exploded View)

Geniuses at work. Residential Mini Splits

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

TECHNICAL GUIDE MODELS: DCPM/DHPM PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS

2018 / 2019 RESIDENTIAL AIR CONDITIONERS

SINGLE ZONE MEGA WALL MOUNTED ENGINEERING MANUAL

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Samsung 360 Cassette, Single Zone, Split System

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5


Product Data INDUSTRY LEADING FEATURES / BENEFITS

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

Air Conditioner CONTENTS

SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL

SUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11

A single answer for multiple zones.

AIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

A single answer for multiple zones.

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

Kühl J Series DUCTLESS ROOM AIR CONDITIONERS THE EXPERTS IN ROOM AIR CONDITIONING. Wall-mounted Ceiling Cassette The Insider Concealed Ducted

DESIGN & TECHNICAL MANUAL

manuflow AIR CONDITIONING & HEAT PUMP PRODUCTS SEER 17

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump

Inverter Single (50Hz/R410A) 5RMA2-01B(5RMA2-01A)

DESIGN & TECHNICAL MANUAL

duct-free air conditioning systems Art cool inverter flex multi-split

Product Data INDUSTRY LEADING FEATURES / BENEFITS

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

(60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A)

Submittal Data Sheet

ENGiNEERiNG AND SPECiFiCATioNS GuiDE

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Air Conditioner CONTENTS CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU. Order No: MAC C1

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

DESIGN & TECHNICAL MANUAL

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

Wall Mounted Split Systems

Pure Efficiency Meets Healthy Living NEW 2013

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER

SERVICE MANUAL. Inverter Wall Mounted Single Split. MODELS Cooling Only. Heatpump SM-5WM-Y-NA-B1

2 &3-4 Head Multi System

Multi Type Room Air Conditioner

Transcription:

Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : AS-W183CSA5 AS-W243CSA5 CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.

Specifications Product Specifications Buyer Model (Indoor Unit / Outdoor unit) Factory Model (Indoor Unit / Outdoor unit) Note : O : Applied, : No relation Filters are optional in some specific areas. For Circuit Breaker Rating, please conform to local standards whenever necessary. Unit LS-180HEV1 (LSN180HEV1 / LSU180HEV1) AS-W183CSA5 (ASNW183CSA5 / ASUW183CSA5) a) HSPF Region V = HSPF Region IV / 1.15 - HSPF IV values comply with US standard. - HSPF V values comply with Canada standard. LS-240HEV1 (LSN240HEV1 / LSU240HEV1) AS-W243CSA5 (ASNW243CSA5 / ASUW243CSA5) Cooling Capacity (Min ~ Rated ~ Max) kw Btu/h 1.08 ~ 4.98 ~ 5.42 3,685~17,000~18,493 1.08 ~ 6.45 ~ 7.03 3,685 ~ 22,000 ~ 24,000 Heating Capacity (Min ~ Rated ~ Max) kw 1.08 ~ 5.57 ~ 6.74 1.08 ~ 6.45 ~ 7.10 Btu/h 3,685~19,000~22,997 3,685 ~ 22,000 ~ 24,226 Outdoor 17ºF (Indoor 70ºF) Btu/h 15,580 (82%) 18,040 (82%) Maximum Heating Capacity Outdoor 5ºF (Indoor 70ºF) Btu/h - - Outdoor -4ºF (Indoor 70ºF) Btu/h - - Power Input Cooling / Heating W 1550 / 1590 2045 / 1935 Running Current Cooling / Heating A 7.1 / 7.2 9.1 / 8.7 Starting Current Cooling / Heating A 7.1 / 7.2 9.1 / 8.7 EER - 10.97 10.76 SEER - 18.0 17 COP - 11.95 11.37 HSPF (Ⅳ / Ⅴ) a) - 9.0 / 7.8 9.0 / 7.8 Power Supply Ø / V / Hz 1 / 208-230 / 60 1 / 208-230 / 60 Power Factor % 94.9 97.7 Air Flow Rate Indoor,Max/H/M/L CFM (m 3 /min) 629(18) / 512(14) / 441(12) / 353(10) 689 (20) / 600 (17) / 494 (14) / 388 (11) Outdoor,Max CFM (m 3 /min) 1342(38) 1,766 (50) Moisture Removal pts/h (l/h) 3.39 (1.6) 4.88 (2.3) Indoor,H/M/L/SL (Cooling) db(a)+3 42 / 40 / 35 / 29 45 / 40 / 35 / 29 Sound Level Indoor,H/M/L (Heating) db(a)+3 42 / 40 / 35 45 / 40 / 35 Outdoor,Max db(a)+3 51 53 Type - Twin Rotary Twin Rotary Model - GKT141MBA GKT176MFA Compressor Motor Type - Brushless DC Motor Brushless DC Motor Oil Type - PVE (FVC68D) PVE (FVC68D) Oil Charge cc 470 470 O.L.P. name - - - Fan(Indoor) Type - Cross Flow Fan Cross Flow Fan Fan(Outdoor) Motor Output W 30 30 Type - Propeller Fan Propeller Fan Motor Type - BLDC BLDC Motor Output W 43 85 Circuit Breaker* A 20 20 Power Supply Cable No. AWG 3 14 3 14 Power and Transmission Cable No. AWG 4 18 4 18 Piping Connections Liquid Side in (mm) in (mm) Ø 1/2 (12.7) Ø 1/4 (6.35) Ø 5/8 (15.88) Ø 1/4 (6.35) Gas Side Drain Hose(O.D, I.D.) in (mm) 27/32, 5/8 (21.5, 16.0) 27/32, 5/8 (21.5, 16.0) Dimensions Outdoor mm inch 770 545 288 30-5/16 21-1/2 11-5/16 870 655 320 34-1/4 25-13/16 12-19/32 Indoor (W H D) mm inch 1,030 325 250 40-9/16 12-13/16 9-13/16 1030 325 250 40-9/16 12-13/16 9-13/16 (W H D) Net Weight Indoor Outdoor lbs (kg) lbs (kg) 27.3 (12.4) 75.4 (34.2) 27.8 (12.6) 94.6 (42.9) Gross Weight Indoor lbs (kg) 32.2 (14.6) 33.1 (15) Outdoor lbs (kg) 80.4 (36.5) 103.6 (47) Operation Range Cooling (Outdoor) ( ) DB 14 ~ 118 (-10 ~ 48) 14 ~ 118 (-10 ~ 48) Heating (Outdoor) ( ) WB 14 ~ 65 (-10 ~ 18.3) 14 ~ 65 (-10 ~ 18.3) Refrigerant & Charge oz (g) R410A / 37.4 (1,060) R410A / 42.3 (1200) Additional Refrigerant Charge oz/ft (g/m) 0.33 (30) 0.33 (30) Piping Length (Min/Max) ft (m) 9.8 (3) / 65.6 (20) 9.8 (3) / 65.6 (20) Chargeless ft (m) 24.6 (7.5) 24.6 (7.5) Max. Elevation Difference ft (m) 32.8 (10) 32.8 (10) Tool Code(Chassis) Indoor + Outdoor SC + UL2 SC + UE Functions Temperature Control Thermistor Thermistor Allergy Safe Filter - - Plasma Filter - - Prefilter (Washable/Anti-fungus) O O 3M Micro Protection filter - - Auto Clean O O Natural Wind (Auto Wind) O O Steps, Fan/Cool/Heat 4 / 4 / 4 4 / 4 / 4 Airflow Direction Control(Up& Down) Auto Auto Airflow Direction Control(Left & Right) Manual Manual Remote Controller Type Wireless LCD Wireless Remote Controller Setting Temperature Range Cooling[ ( )] 64~86 (18~30) 64~86 (18~30) Heating[ ( )] 60~86 (16~30) 60~86 (16~30) Auto Operation (Micom Control) - - Auto Changeover (Micom Control) O O Self Diagnosis O O Timer 24h, On/Off 24h, On/Off Sleep Operation O O Soft Dry Operation O O Restart Delay (Minute) 3 3 Deice Control (Defrost) O O Hot Start O O Jet Cool / Jet Heat O O Low Ambient Operation O O Special Function Water Level sensor Water Level sensor - 2 -

Piping Diagrams Piping Diagrams Model : AS-W183CSA5 Indoor Unit Outdoor Unit FIELD PIPING (Ø 1/4 Copper Tubing) 2-Way Valve Liquid Side EEV Th1 M Th5 Heat Exchanger (Evaporator) Th3 M Heat Exchanger (Condenser) Th2 FIELD PIPING (Ø 1/2 Copper Tubing) 3-Way Valve Reversing Valve Th6 Gas Side Accumulator Th4 Compressor : Cooling : Heating LOC Description PCB Connector Th1 Thermistor for indoor air temperature CH-TH1(INDOOR) Th2 Water level sensor (Option) CH-TH2(INDOOR) Th3 Thermistor for evaporator middle temperature CH-TH3(INDOOR) Th4 Thermistor for discharge pipe temperature CN-TH2(OUTDOOR) Th5 Thermistor for outdoor air temperature Th6 Thermistor for condensing temperature CN-TH1(OUTDOOR) - 3 -

Piping Diagrams Model : AS-W243CSA5 Indoor Unit Outdoor Unit FIELD PIPING (Ø 1/4 Copper Tubing) 2-Way Valve Liquid Side EEV Th1 M Th5 Heat Exchanger (Evaporator) Th3 M Heat Exchanger (Condenser) Th2 FIELD PIPING (Ø 5/8 Copper Tubing) 3-Way Valve Reversing Valve Th6 Gas Side Accumulator Th4 Compressor : Cooling : Heating LOC Description PCB Connector Th1 Thermistor for indoor air temperature CH-TH1(INDOOR) Th2 Water level sensor (Option) CH-TH2(INDOOR) Th3 Thermistor for evaporator middle temperature CH-TH3(INDOOR) Th4 Thermistor for discharge pipe temperature CN-TH2(OUTDOOR) Th5 Thermistor for outdoor air temperature Th6 Thermistor for condensing temperature CN-TH1(OUTDOOR) - 4 -

Wiring Diagrams Wiring Diagrams Indoor Unit (ASNW183CSA5/ASNW243CSA5) CN-IN/N1 CN-L1 CN-U/D CN-DISP3 CN-DISP1 CH-TH1 CH-TH2 CH-TH3 CN-COM2-5 -

Wiring Diagrams Outdoor Unit (ASUW183CSA5) CN_U_V_W CN_FAN(DC) CN_TH1 CN_EEV1 CN_TH2 CN_4WAY CN_COM P(L)_BR P(N)_BL CN_COIL2 WCN_GND2 CN_COIL1 WCN_GND1-6 -

Wiring Diagrams Outdoor Unit (ASUW243CSA5) CN_LGMV CN_FAN(DC) CN_EEV1 CN_U_V_W CN_TH2 CN_TH1 CN_4WAY CN_COM P(L)_BR P(N)_BL WCN_GND1 CN_COIL1 CN_COIL2 WCN_GND2-7-

Exploded View Exploded View Indoor Unit Model: ASNW183CSA5/ASNW243CSA5 135316 152301 268711A 135511 131111 131410 135303 149303 733010 359011 267110 342800 135500C 149304 135090 W50400 354212 352150 354210 346810 249951 135500A 146811B 268711E 268711C 35211B 147582A 145200A 147582B 145200B 263230A W6640 135311 147581 263230 LOC. Descriotion PCB Connector 263230 Thermistor for indoor air temperature CN-TH1 (Indoor) 263230A Thermistor for evaporator middle temperature CN-TH3 (Indoor) - 8 -

Exploded View Outdoor Unit 137213A W4986B 550140 447910 435301 437211 237202 W4986A W6631 137213B 559010 546810 549610 261704 430410 152503 561410 435512 554160 554031 552202 435312 552116 552203B 148000 263230C 552203A 55211G 552200B 263230D 263230B 661400 649950 268711F W6640 435513 Model : ASUW183CSA5 LOC. Descriotion 263230D Thermistor for discharge pipe temperature 263230C Thermistor for outdoor air temperature 263230B Thermistor for condensing temperature PCB Connector CN-TH2 (Outdoor) CN-TH1 (Outdoor) -9-

Exploded View Outdoor Unit Model : ASUW243CSA5 437211 237202 435301 152503 430410 559010 546810 349600 435512 649950 W6640 261704 263230C 268711F 447910 W4986A 554160 550140 263230D 552116 W6631 552202 W49810 561410 437212 435511B 135500 661400 552203A 55211G 552203B 552200B 554031 LOC. Descriotion PCB Connector 263230C Thermistor for condensing temperature Thermistor for outdoor air temperature CN-TH1 (Outdoor) 263230D Thermistor for discharge pipe temperature CN-TH2 (Outdoor) - 10 -

P/NO : MFL67499993 February, 2015