Genie Heated Regulator Installation & Operation Instructions

Similar documents
Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

Performance Data. curus Component Recognized; File No. E IP 20

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Hazardous Location Heaters. 50W and 80W Models INSTRUCTION MANUAL. Rev. I 2018 nvent P/N

Installation, Operation, & Maintenance Manual. MODEL: MPRVSS (NGL Sr.), MPRVSSJR (NGL Jr.)

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Description. Applications

Model 144H. Product Data Sheet , Rev DB February Content

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Dräger Polytron 5720 IR Toxic Gas Detection

Model 144H. Product Data Sheet , Rev DB February Content

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

standards: standards:

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

TOUCH-SAFE HEATERS INDUSTRY STANDARDS

Worcester Controls PS/PM Series UltraSwitch. Switchbox

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

OPTIBAR DP 7060 Supplementary Instructions

Inductive slot sensor

INSTRUCTION & SERVICE MANUAL

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Gas cylinder scale Model GCS-1

Enclosure Heaters and Fan Heaters

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

VERSAFLOW VORTEX Supplementary instructions

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Mustang Vaporizer. Installation, Operation & Maintenance MV

Technical Specification VFD

Certification Supplement Manual

Manual Power relay SR853

Dräger PIR 3000 Detection of flammable gases and vapours

Application. Specifications. Finish

Ultrasonic Point Level Switches

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Brasch Hazardous Location Unit Heaters

INSTRUCTION MANUAL (ATEX / IECEx)

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 5720 IR Detection of carbon dioxide

Technical Data. General specifications. Rated operating distance s n 5 mm

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

CR 027 PTC Fan Heater W

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Operating Manual MS220KA and MSR220KA

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Passive Cooling Systems Air Conditioning Without the Need of Energy

Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules

Consignes d installation


Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Fisher 2100 Pneumatic and 2100E Electric Liquid Level Switches

Ar-Mite TM Low Flow Armored Flowmeter

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

OPTIWAVE X500 Supplementary Instructions

Explosion Protected Panelboards D2Z Series

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

Certificate of Compliance

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Ultrasonic Switches. Features & Benefits

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Explosion-proof Immersion Heater Type D-8660

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Rosemount 3051CFP Integral Orifice Flowmeter

CF1 ProVector Explosion-Proof Heaters

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Anti Condensation Heaters

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

Certificate of Compliance

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

Operating instructions

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

High Pressure Conductivity Monitor

Flameproof Manual Call Points

Field Certification Certificate of Compliance

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

HYGROPHIL H process hygrometer

Transcription:

Genie Heated Regulator Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737 Phone: (225)-644-5255 Website: www.geniefilters.com Fax: (225)-644-3975 E-mail: sales@geniefilters.com! Safety Warnings Failure to abide by any of the safety warnings could result in serious injury or death. Electrical power must be OFF before and during installation and maintenance or personal injury may result. Do not exceed any equipment pressure ratings. GHR TM surface temperature will approach temperature limit specified in technical specifications. Gloves may be required for set point adjustments. Select a mounting location so that the enclosure will not be subjected to impact by heavy objects. Impacts can damage enclosed devices. Use care to prevent dirt, grit, or other foreign material from lodging on threads. If any such material settles on these threads, clean them with an approved solvent (to avoid the possibility of an explosion, oxidation, and corrosion, do not use gasoline or similar solvent), then re-lubricate with an approved thread lubricant. All appropriate national, state and local electrical codes must be followed. The power supply is with the help of a silicone cable, notch and oil resistant. The cable is intended for installation inside a rigid metallic conduit, cable tray or a similar method which provides sufficient mechanical strength to the cable against stress and bending. Grounding to be provided at the final location of installation. Not designed for external fire. Prior to use in a system, a properly sized relief device is to be installed which limits the use to 110% of the MAWP. Do not use the regulator as a shut off device. Tools Required Flat or Phillips Head screwdriver 2010 A+ Corporation, LLC. All rights reserved. SCC-GHR-CSA-InsInstallationOperation_082018

Technical Specifications Technical Specifications Maximum pressure rating Outlet pressure range Temperature range Port sizes Cv Coefficient Maximum flow rate Wetted materials Electrical connection Electrical approval GHR Dimensions 4.1 7.2 OUTLET PORT 6000 psig (414 bar) per criteria of ANSI/ASME B31.3 0-10 psig (0-0.7 bar), 0-25 psig (0-1.7 bars), 0-50 psig (0-3.4 bars), 0-100 psig (0-6.9 bars), 0-250 psig (0-17.2 bars), 0-500 psig (34.5 bars) Ambient: GHR (CSA): -40 to 302 F (-40 to 150 C) 901-GR: 0 to 145 F (-18 to 63 C) GHR (ATEX): -40 to 140 F (-40 to 60 C) Process (all models): -15 to 300 F (-26 to 149 C) - standard seals -40 to 300 F (-40 to 149 C) - low temperature seals 901-GR controller: 95 to 300 F (35 to 149 C) set at 300 F (149 C); backup thermal cutoff opens at 338 F (170 C) 1/4 FNPT 0.023 ~10 SLM - Standard Liters per Minute (consider heat transfer limitations) Machined parts: 316/316L stainless steel / NACE compliant All other metal parts: stainless steel / NACE compliant Regulator seat material: PFA Seals: Fluoroelastomer Conduit (CSA): GHR: 1/2 FNPT 901-GR: 3/4 FNPT Cable OD (ATEX/IECEx): 3/8 (10mm) GHR: 80W @110-265 VAC or 25W @ 22-26 VDC 901-GR: 200 W @ 120 VAC or 700 W @ 240 VAC CSA Certified Assembly: File # 235756; Class 1, Division 1, Groups B, C, & D; T3 ATEX/IECEx Heater Block (Model GHR only): Zone 1, II 2G, Ex d, IIC, T3, Gb Side View 2.2 ADJUSTMENT SCREW INLET PORT Top View 3.8 3.1 2.5 3.5 2.5 MOUNTING HOLES FOR 1/4-20 SCREWS 2.4 1.9 2.4 901-GR CONDUIT CONNECTION 4.8 5.6 12.7 7.1 7.1 1.6 TEMPERATURE CONTROLLER 1 4 NPT INLET PORT 5.8 2 3 4 CONDUIT CONNECTION 2.5 1 4 NPT OUTLET PORT 2010 A+ Corporation, LLC. All rights reserved. SCC-GHR-CSA-InsInstallationOperation_082018

Installation Instructions Step 1. Depressurize the system Valve off the sample flow prior to installation of the Genie Heated Regulator. TM Step 2. Connect the Genie Heated Pressure Regulator The Genie inlet and outlet ports are labeled. Connect tubing from the sample stream to the Genie Inlet port. Connect tubing from the Genie Outlet port to the next device in the sample system. The Genie port that is not labeled is an atmospheric reference port for the regulator. It is threaded so that optional tubing can be connected to this port to enable a captured vent if so required; however, this port should NOT be plugged or the performance of the regulator will be affected. Step 3. Connect the Block Heater Refer to the INTERTEC literature provided with the unit for electrical wiring. Step 3. Adjust pressure Turn off electrical power to the regulator, and take precauitons to prevent burns. the regulator will be HOT. At this point the sample pressure can be adjusted to the desired value. To raise the outlet pressure, turn the pressure adjustment screw clockwise. To lower the outlet pressure, turn the pressure adjustment screw counterclockwise while gas is flowing through the regulator. To allow sample flow, slowly open external valving. At high supply pressure, a sudden change may be observed on the downstream pressure gauge as the valve stem moves away from the seat. Slight re-adjustments may be necessary until the pressure and flow have equilibrated. Tighten the pressure adjustment screw lock nut firmly against the washer to prevent unintended changes in pressure adjustment. 3 2010 A+ Corporation, LLC. All rights reserved. SCC-GHR-CSA-InsInstallationOperation_082018

Model Numbering & Additional Part Numbers Model Numbering & Additional Part Numbers Your model number is determined by your specific needs. Materials of construction must be compatible with process fluid. Model GHR = GR with self-limiting block heater 901-GR = GR with temperature controller Sealing material 0 = Fluoroelastomer (standard) JW = RGD resistant HNBR (other materials available upon request) Outlet pressure range (psig) 0 = 0-25 1 = 0-50 2 = 0-100 3 = 0-250 4 = 0-500 9 = 0-10 1= AC power 2 = DC power (not available in Model 901-GR) Electrical approval C = CSA A = ATEX/IECEx (not available in Model 901-GR) How to build the model number: Model Sealing material Outlet pressure range Electrical approval SS P 4 GHR How to build the heater block replacement model number: Electrical approval Spare Parts & Accessories (sold separately) Kozy Insulated Cover - Part # KZ-10-L (not for enclosures) 901 Heater Base & Controller Replacement - Part # 901-01-SS Genie Regulator Accessory Manifold - pressure gauge, ball valve & relief valve Inlet filter replacement - Part # GHR-5FSS Not designed for external fire or for use with mixtures of explosive gases and air/oxygen. Prior to use in a system, a properly sized relief device is to be installed which limits the use to 110% of the MAWP. 5 Genie, Genie Heated Regulator ȚM and GHR TM are trademarks or registered trademarks of A + Corporation, LLC. All other referenced trademarks are the property of their respective owners.

www.intertec.info SL BLOCKTHERM C Self-limiting Block Heater 1 Application The self-limiting electric conduction heater is designed to be attached directly to manifolds, measuring or analyzing instruments, control valves and similar equipment installed in hazardous areas. It heats the device by conduction. This is the easiest, safest and most economical method of freeze protection or temperature maintenance. 2 Features & Advantages Energy saving, high output Self-limiting, no fusable link or limiter Compact, requires very little space Adjusts automatically to the voltage 3 Description BLOCKTHERM is a metal heating block with a ½ NPT thread to connect to a conduit. The PTC cartridge provides the heat that is transferred through the heater block to the device to which it is attached. 4 Performance A conduction heater requires considerably less power than a finned convection heater, as the heat conduction qualities of metal are much better than those of air. The air surrounding the whole installation in the enclosure serves as additional insulation. The diagram below shows the heating power at different block temperatures. 120 100 80 60 40 5 Explosion Protection CSA Certificate 1655545 (LR43674) CSA Type of Cl. 1, Div. 1, Grp, ABCD Protection Cl. 2, Grp, EFG 6 Technical Data Ingress Protection IP 68 Nominal voltage 110 to 277 V Ambient Temperature -76 F to 302 F/ -60 C to +150 C Connection cable 3x AWG16; Ø 0,37 / 9,4 mm Conduit connection ½ NPT Length of Cable 39 / 1 m Dimensions see Types and drawings page 2 Material seawater-proof aluminium, black anodized SL BLOCKTHERM Profile CKA T3 CLA T3 CKA T4 CLA T4 Temperature Class T3 T4 Nominal Power 80 W 50 W Length of Block 3.5 / 4.1 / 3.5 / 4.1 / (see Pt.11) 90 mm 105 mm 90 mm 105 mm Weight ca. 1,1lb/ 500g ca. 1,1 lb/ 500g All INTERTEC explosion-proof heaters can also be supplied European standard (ATEX) e.g.: SL BLOCKTHERM DKA T3 as Bi-Standard (see datasheet HD508) in a less expensive, Non-explosion-proof design e.g.: SL BLOCKTHERM NKA 7 Options Heating Power [W] 20 0 CKA T3, B80 CKA T4, B50 0 20 40 60 80 100 Block temperature [ C] TSxx JC Thermostat kit with 3 port junction box AM Failure alarm, opens at < 41 F/ 5 C and can only be ordered on the L version body 3M Connection cable 10 / 3m long Not all options can be combined. Ordering example: SL BLOCKTHERM CKA T3 3M HD662-3c SL BLOCKTHERM C page 1/ 2 INTERTEC Instrumentation - Sarnia, Ontario - Houston, Texas - Phone: 1-888-875-8756

www.intertec.info SL BLOCKTHERM C Self-limiting Block Heater 8 Temperature Limitation 11 Dimensions PTC-Elements (Positive Temperature Coefficient) raise their electric resistance with rising temperature. High resistance results in low heating power. The heating power is very low at high temperatures so that the temperature cannot exceed the maximum temperature of the respective temperature class. 9 Supply Voltage In addition to the above mentioned temperature characteristics, the PTC elements show a varistor effect. They control their resistance in accordance to the supply voltage. The nominal power supply voltage may be 110 to 277 V with the same heater. The output may be a maximum of 15% higher than that shown on the diagram on page 1. 12 Mounting 10 Electric Wiring L N PE Junction Box The BLOCKTHERM heater dissipates the heat by conduction. It should be mounted to a flat surface of a heat conducting material (e.g. metal). One bolt is sufficient to mount the heater. bn bu bn bu gn/ye > TS Option Heater bu=blue bn=brown gn/ye=green/yellow Example: The SL BLOCKTHERM CKA T4, which is attached to a Fisher-Rosemount 3051H Transmitter by means of an aluminum adapter block, guarantees freeze protection for the transmitter, manifold and impulse lines installed in an INTERTEC Instrument Enclosure at an outside temperature as low as -13 F/ -25 C. As well the SL BLOCKTHERM CKA T3 will provide protection to -49 F/ -45 C. HD662-3c SL BLOCKTHERM C page 2/ 2 INTERTEC Instrumentation - Sarnia, Ontario - Houston, Texas - Phone: 1-888-875-8756

www.intertec.info Operating Instructions for Heaters SL THERM 1 Application 4 Connection SL THERM Heaters are manufactured in accordance with Directive 94/ 9EC (ATEX 100a) and are approved as conduction heaters (direct heating via flange-mounting to the instrument) and/or as convection heaters (heat transfer to the ambient air by natural convection) for use in Ex-zones 1 and 2 for explosion groups G/ D in temperature classes T3 to T6. Optional thermostats can be integrated in the connecting cable. The respective operating instructions have to be observed. EC Type Examination Certificate PTB 02 ATEX 1116X with Schedule and Supplements in German and English as well as IEC Scheme Certificate IECEX PTB 07.0055X please see www.intertec.info. 2 Technical Data Rated voltage 110 to 250 V AC or DC Permissible operating voltage Max. 265 V AC or DC Rated current (taking into account VDE 0298) Max. 10 A Ambient temperature - 60 to + 60 C Max. permissible operating temperature range at - 60 to + 180 C normal rating Switching capacity of failure alarm 10 A/ 250 V AC 3 Installation Take care not to bend or exert any load on the connection cable during the transportation or unpacking of the heater. To ensure effective convection, the heater should be installed in accordance to the installation and minimum clearance requirements described in the data sheets. Please note that the absolute heat transfer coefficient of the surrounding enclosure must not be smaller than 0.5 W/ K. Also make sure to comply with the permissible operating temperature range. Before entry in the customer-supplied junction box, the cable must be firmly installed, observing the permissible bending radius of 5 times the outside cable diameter. In the dust - hazardous area with the applicable requirements of the EN 60079-14 have to be observed. The heater must only by connected and secured by personnel technically qualified in accordance with the label specifications "rated voltage" and "rated current": If operating voltage = rated voltage, the heater will generate the specified nominal output, with an allowance to voltage fluctuations of up to 10 %. Circuit breakers suitable for up to 16 A can be used for short circuit and line protection. A ground terminal is provided for the purpose of ensuring potential equalization. The terminal is marked as such. In a TT or TN system, a residual current operated protective device (RCD) must be used whose rated response fault current does not exceed 100 ma. Residual current devices with a rated response fault current of 30 ma are to be preferred. In an IT system, an insulation monitor must be used that switches off the power supply as soon as the insulation resistance falls to 50 ohms per volt of the rated voltage or lower (see DIN EN 60079-14:2008; section 7.4). 5 Initial Operation The heater can be switched on as soon as it is properly installed in accordance with the installation instructions specified in points 3 and 4, ensuring free convection and the necessary clearances. 6 Maintenance Due to the type of construction, the heater requires no maintenance. Performance and safety tests can be conducted at intervals to be determined by the operator in compliance with current regulations. Repair work must only be carried out by the manufacturer. In the dust - hazardous area with the applicable requirements of EN 60079-17 and the EN 60079-19 have to be observed. 7 Safety instructions Installation of the heater in an exposed position involves a certain risk of injury, with especially the ends of the fins and hot surfaces posing a potential danger. Max. 160 C with T3 Heaters Max. 100 C with T4 Heaters Max. 70 C with T5 heaters Max. 50 C with T6 heaters HO604-2e SL THERM -Operating instruction Page 1/ 1