- Pamphlet A2404 TLV. ertrap a ic I Pump & Pump/Trap. GP Series GT Series

Similar documents
Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

TL\l DRAIN TRAP. , s. JA JAHR Series I GS. TATSU2 SS1VA/JAHRASeries. Pamphlet A

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Pump & Trap Combinations

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Pure Performance For Steam Mains and Tracers

What is a Secondary Pressure Drainer?

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Pamphlet A2000. TL\l. Free Float Steam Trap Series

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

Pamphlet M JA3D / JA Series / G8 AIR & DRAIN TRAPS. TATSU2 SS1VG / JAHSeries

THERMOSTATIC STEAM TRAPS

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

LIQUIDATOR UMT-TD Series Thermodynamic

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

System Solutions. Efficient energy use, effective flash steam utilisation, and tailor-made customer solutions CHEMICAL THE STEAM SPECIALIST.

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

THERMODYNAMIC STEAM TRAPS

MFP14 Automatic pumps for condensate and other industrial fluids

STEAM TRAPS

Silhouette. Feedwater Heater. Boiler Feedwater

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

MFP14 Automatic pumps. for condensate and other industrial fluids

THERMODYNAMIC STEAM TRAPS

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

STAINLESS STEEL PRODUCT GUIDE. Pamphlet M8012

Pamphlet M AIR & DRAIN TRAPS. JA JAHR Series / G8 TATSU2 SS1VG / JAHRG Series

THE THERMOSTATIC STEAM TRAP

Pumps. Pressured-powered pump catalog. The more reliable and efficient way to pump condensate and other liquids.

Liquid Drainers LIQUID DRAINERS

PRESSURE MOTIVE PUMP (PMP) APPLICATIONS

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Steam Condensing Heat Exchanger SR-3 / SR-8

Pure Performance For Steam Mains and Tracers

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

HEAT EXCHANGER FORMULAS & EXAMPLE

Documento Descargado desde:

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

IN THE PULP AND PAPER INDUSTRY

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

Hoffman Specialty General Catalog

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

LIQUIDATOR 450 SERIES

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

FT14 Ball Float Steam Trap (Screwed)

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Domestic Pump Condensate Transfer Equipment

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

13-1. Temperature Regulator

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

STEAM VALVE SUPPLY & SYSTEM DESIGN

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Series 1140 and 1141 Temperature Regulators

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

SECTION STEAM CONDENSATE PUMPS

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

TECHNICAL. Series 18. Pump Packages

Noiseless Heater Vacuum Relief Valve

Economical and simplified solutions that offer quality and optimum steam trap service.

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

GIRTON CABINET WASHER MODEL 794A

STEAM AND TRAP FUNDAMENTALS

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

Automatic Temperature Controller (ATC)

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

High Capacity Instantaneous Steam Fired Water Heater

A. This Section includes the following domestic water piping specialties:

5. CONDENSATE PUMPS/UNITS

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

Industrial Processing Solutions

Standard Features. Performance/Capacities

PIONEERS IN AIR VACUUMS

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

Our Know-How. Your Peace of Mind. Steam Solutions

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Refrigerant Valves/Accessories

Strategies in Optimizing Condensate Return

Blowdown Separator & Aftercoolers

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

INSTALLATION, OPERATION

Transcription:

- Pamphlet A2404 TLV. ertrap a ic Pump & Pump/Trap GP Series GT Series

Effective Processing mproves Plant Efficiency ncreased productivity and product quality, plus reduced energy consumption and water treatment are some of the many benefits of condensate drainage and recovery. The TU GP/GT PowerTrap series provides the perfect solution for optimizing condensate processing in many applications. 1 Handling Heat Exchanger "Stall" Stabilized temperature control improves product quality Elimination of water hammer prevents equipment damage and improves safety Prevention of corrosion caused by condensate accumulation 2 Effective Recovery Energy recovered from condensate reduces boiler fuel costs Reusing water reduces water treatment costs Reduces effluent treatment and disposal costs 3 No Cavitation Recovery of hot condensate up to 428 F possible without cavitation Low filling head capability permits drainage from near-grade equipment outlets. Eliminates the seal, bearing and impeller damage that can occur in standard centrifugal pumps GT10 GT14 GT10L GT14L GT14M 4 No Electricity Required deal for use in areas requiring explosion-proof equipment, and areas with no electrical supply Reliable mechanical operation eliminates the need for complex level controls Quick and easy to install and maintain GTSC

TU' s Po\VerTrap Series- The Total Solution to Heat Exchanger 11 Stall" mportance of 66 Stall" Prevention "Stall" prevents condensate from being discharged from heating equipment. t results in: Process Temperature Swings V1 V1 0... As the "stall" cycle repeats, the steam pressure in the equipment varies above and below the back pressure, causing product temperature and quality fluctuations. Water Hammer Damage Water hammer can occur when backed-up condensate re-evaporates, or as incoming hot steam hits cooler backed-up condensate and instantly condenses. Water hammer damage to tubes and stays Tube Corrosion and Damage Backed-up condensate in the equipment can form carbonic acid, which results in tube corrosion. Equipment temperature fluctuations can cause thermal shock and fatigue damage to tubes. Tube corrosion TLVmis PowerTrape series provides complete condensate drainage, the l<ey to eliminating "stall" and its related problems. Optimum performance can now be yours with the PowerTrapmi. A Closer Look at the 66 Stall" Cycle ---------------ii!-----------, : 1 1 Controller : 1 1 1 Control valve P1: Equipment pressure Product outlet temp. r;:::=.::::::::::=:::::i c> CD When the demand for heating energy is high, the control valve is wide open, P1 is greater than P2 and condensate is discharged from the trap. When the demand decreases, the control valve throttles in order to reduce the heating energy, and P1 drops. f P1 drops to P2 or below, the trap can no longer discharge condensate against the back pressure. then backs up in the heat exchanger, and the equipment becomes condensate logged. This condition is known as "stall". recovery line P2: Back pressure Product inlet temp. ---<:=i When condensate is backed-up inside the equipment, the product temperature falls. The system compensates by opening the control valve again. P1 increases and, when it becomes greater than P2, condensate is forced out through the trap, and the cycle begins again. Steam trap 2

PowerTrap Benefits 1 Built-in Steam Trap mproves Performance fgt series)------- Automatically switches between pump and trap operation, in response to process conditions nternal trap mechanism always matches pump output, with no damage to trap, and eliminates need for sizing No need for external steam trap means simplified compact design and lowered installation costs Trap valve and valve seat are both stainless steel for minimum leakage and maximum life 2 Snap-action Mechanism Maximizes Life----------- Dii nstantaneous Switching Heat-treat hardened stainless internals Lifetime warranty* nickel-based alloy compression coil spring The 2-year warranty** snap-action mechanism simultaneously opens or closes motive medium inlet and exhaust valves, preventing erosion and resultant leakage * GP/GT 4M, GP/GT 4L, GP/GT OL, GP/GTSC: -year warranty ** GP/GTSC: -year warranty Contact TLV for full warranty details 3 Low-maintenance Design Reduces Labor---------- Easy inline maintenance, without removal of piping* Fast and easy cleaning of intake valve by simply opening a plug to remove (GP/GT! 4, GP/GT! 0, GP! OF, GP/GTSC) Non-cavitating design eliminates the seal, bearing and impeller damage that can occur in standard centrifugal pumps * GP OF, GP/GTSC-motive medium piping must be removed 4 Stainless Steel Checl< Valves* for Durability --------- Center guided check valves CK3MG and CKF3MG are used for maximum reliability even with dirty condensate (GP/GT! 4, GP/GT! 0, GP! OF, GP/GT! OL) Newly developed swing type check valve CKFSM enables use with a filling head as low as 12" (GP/GT! 4L, GP/GT! OL), 14" (GP/GT! 4M) Last longer than bronze check valves Quiet operation * GP/GTSC are equipped with internal stainless steel check valves 5 Economical Unit with Retrofitable Mechanism -------- One-piece pump assembly for easy installation, maintenance and retrofit to pump bodies of certain other manufacturers Lighter-weight model, with ASME certified fabricated steel body for increased cost effectiveness 3

Construction GT14/GT14M/GT14L GT10/GT10L Mechanical pump with built-in trap GP14/GP14M/GP14L GP10/GP10L Mechanical pump GP10F Mechanical pump with retrofitable mechanism GTSC Compact mechanical pump with built-in trap GPSC Compact mechanical pump Materials Body (except GP! OF, GP/GTSC) Body (GP! OF) Body (GP/GTSCJ Cover (except GP! OF, GP/GTSC) 2 Cover (GP! OFJ Cover (GP/GTSCJ Cover Gasket (GP/GT14M, GP/GT14L, GP/GTJO, GP/GTJOL, GP!OF) 3 Cover Gasket (GP/GT! 41 Cover Gasket (GP/GTSCJ *Cast stainless steel available as option **Not shown Operation Pump/Trap: GT10 D GT Trapping/Filling Cycle When GT inlet pressure is greater than back pressure, the GT acts as a trap, continuously discharging condensate. When inlet pressure is less than back pressure, condensate cannot be discharged, so it accumulates in the body, causing the float to rise. As the float rises, the trap opens, although condensate still cannot be discharged. Fl GT Discharge Cycle When the float reaches its highest position, the trap is fully open and the snapaction mechanism actuates, instantly both opening the motive medium intake valve and closing the exhaust valve. The motive medium pressure forces out the condensate, and the float falls. The snap-action mechanism resets, instantly opening the exhaust valve and closing the intake valve. The cycle then repeats. Exhaust -0- GTSC shown above GPSC not equipped with trap unit Cast ron or Cast Steel* Lever Unit 4 Fabricated Carbon Steel* (GP/GT! 4, GP/GT! 0 only) Stainless Steel Cast ron or Stainless Steel 5 Snap-action Unit Stainless Steel Cast ron or Cast Steel* 6 ntake Valve Unit Stainless Steel Cast Steel* 7 Exhaust Valve Unit Stainless Steel Cast ron or Stainless Steel 8 Float Stainless Steel Graphite Compound 9 Trap Unit Stainless Steel Graphite/Stainless Steel JO Check Valve** Stainless Steel Fluorine Resin 11 Air Vent Unit** (GTSC only) Stainless Steel Pump:GP10 0 GP Filling Cycle The pump body is equalized to the inlet receiver (usually atmospheric) by the open exhaust valve. This allows condensate to drain by gravity into the pump, where it accumulates and causes the float to rise. Fl GP Discharge Cycle When the float reaches its highest position, the snap-action mechanism actuates, instantly both opening the intake valve and closing the exhaust valve. The motive medium pressure forces out the condensate, and the float falls. The snapaction mechanism re-sets, instantly opening the exhaust valve and closing the intake valve. The cycle then repeats. Exhaust -0-4

Systems for Many Different Applications The TLV PowerTrap series meets a variety of condensate processing needs. Closed S stem Open S stem Venting pipe System OveNiew recovery line Equipment recovery line Equipment Benefits Notes No need for external steam trap (GT model features built-in trap) No flash steam discharge Small reservoir Use with vacuum equipment possible Only one piece of equipment possible per system Equipment has minimum height requirement to ensure that condensate flows naturally, by gravity (approx.: GP/GT! 4, GP/GT! 0-32"; GP! OF - 40"; GP/GT! 4M - 14"; GP/GT! 4L- 12"; GP/GT! OL - 12" or 20"; GT5C - 7") Collection of condensate from multiple equipment possible Can be used where trap is lower than receiver, such as equipment situated near grade (providing there is sufficient differential pressure) Separate steam trap required for each piece of equipment Requires venting pipe to discharge flash steam to atmosphere Approx. Max. Pump Discharge Capacity Model Some Application Examples 17,000 lb/h and less less than 6, 000 lb/h less than 3, 000 lb/h (GTO) (GTl4M) (GTOL) 12,000 lb/h and less less than 4, 000 lb/h less than 300 lb/h (GTl4) (GTl4L) (GT5C) greater than 17,000 lb/h (install pumps in parallel) Mechanical pump Mid-size Compact with mechanical pump mechanical pump built-in trap with built-in trap with built-in trap GT14/GT10 GT14M/GT14L GT10UGT5C Where there is ALWAYS a negative pressure differential (e.g. vacuum equipment), GP14/GP14M/GP14L/GP10/GP10L/GP10F can be used Large process/ flow, such as: re-boilers, large heat exchangers Small to medium process/flow, such as: room heaters, small to medium heat exchangers 18,000 lb/hand less (GP!O, GP!OF) 13,000 lb/h and less (GPl4) 18,000 lb/hand greater (install pumps in parallel) Mechanical pump GP14/GP10/ GP10F Large process trap discharges, such as: cylinder dryers, platen presses less than 7,000 lb/h (GPl4M) less than 4, 500 lb/h (GPl4L) Mid-size mechanical pump GP14M/ GP14L less than 3, 500 lb/h (GP!OL) less than 320 lb/h (GP5C) Compact mechanical pump GP10U GPSC Small to medium process trap discharges, such as: recovery: trace lines & mains, small to medium heat exchangers Closed System (GTJ Sample Application: Drainage & Recovery from Heat Exchanger Open System (GPJ Sample Application: Recovery from an Open Tank Vent line to atmosphere (Pipe Safely) l recovery line Collection of condensate up to 365 F possible Prevents clouds of steam from affecting the work environment Collection of condensate up to 212 F possible Makes it easy to design systems that can easily obtain pressure differential lit CAUTON Pipe all atmospheric discharge to a safe area 5

nstallation Piping Examples (For explanation purposes only, not intended as installation designs.) Closed System Steam supply 9 ------'----' Air Vent CD JL (to atmosphere, V pipe safely),----------ii ---------' : Temperature controller :, Control 1 : valve : recovery line *Consult TLV for assistance. Closed system condensate recovery using a GT PowerTrap CD Check valve (2) Strainer Gate valve or needle valve Gate valve or ball valve @Air vent Steam trap =Steam line = Exhaust and air discharge lines = line LhcAur10N A: Steam trap outlets may be piped to either the condensate reservoir or the condensate recovery line. Where condensate from the equipment is less than 17 6 F, it is best to pipe to the condensate recovery line. n closed system applications where steam condensate is pumped, use steam as the motive medium. The height of the condensate outlet on the equipment must be at least: filling head + diameter of reservoir. Please read the instruction manual to ensure safe usage. Open System Steam supply 9--- "' c ===========c::>==== Open vent line {!r (Pipe safely) r--------11----------, Temperature controller recovery line Steam trap Steam trap Other steamusing equipment Open system condensate recovery using a GP PowerTrap CD Check valve (2) Strainer Gate valve or needle valve Gate valve or ball valve @Steam trap =Steam line = Exhaust and air discharge lines """""" line l&cauton t is recommended that the equipment condensate outlet be higher than the condensate receiver, in which case a vacuum breaker may also be required. The vent pipe and overflow pipe should discharge to a safe place. Please read the instruction manual to ensure safe usage. 6

nstallation Piping Example for GTSC * *Actual installation differs depending on the desired discharge capacity and operating conditions, etc. See product specifications data sheet (SOS) for details. Easy Maintenance nlet/outlet check valves and motive medium intake valve unit are removable while connected to the piping The unit can be disconnected by removing only 2 bolts The body can be disassembled by removing six bolts while still connected to the piping Simple nstallation Only motive medium intake pipe - no exhaust pipe necessary nlet/outlet piping is linear, streamlined and efficient Built-in air vent and check valves minimize external installation 6 m Filling Head Usable with low condensate outlet heat exchangers ons Values attained using a TLV CK3MG (screwed) or CKF5M/CKF3MG (flanged) check valve, unless otherwise indicated. GP/GTSC have a built-in check valve. Model GTl4 GPl4 GTO GPO GTl4M GPl4M GTl4L GPl4L GTOL GPOL GPOF GT5C GP5C Approx. Max. Pump Discharge CapaC1ty [lb/h) 12,000 13,000 17,000 18,000 6,000 7,000 4,000 4,500 3,000 3,500 18,000 300 320 Approx. Built-in Trap Cap. [lb/h) 80,000-80,000 - J0,000-27,000-24,000 - - 2.200 - Dimensions (in) i c.. Eli 1,:27'/o " D D D ". 0 ' 7/10 511 tj] :J] i N Connection* 1 s F s F s F s F F s F s F s s Body Cast ron 280-273 - 280-273 - 190 198 124 122 101 99 44 44 Material Carbon Steel Cast Steel 306 328 300 322 J06 J28 JOO 322 205 207 - - 110 108 - & Weight 154-40 40 fib) Cast Stainless Steel - - - - - - - - - - - - - - - Pumped Med. nlet J 2,J J 2,J J 2,J J 2,J 1r12 1,1 1 12 1,1 1 12 J Pumped Med. Outlet 2 1r12 2 Size fin) Motive Med. nlet 1 /2 3/4 1 /2 Pump Exhaust Outlet 1 /2 3/s ' Max. Oper. Press. PMO 200 ps1g 150 ps1g 200 ps1g 150 ps1g 75 ps1g Max. Oper. Temp. TMO J92"F J65"F 428"F 365 "F 428 "F 365 "F Max.Allow. Press PMA 200 ps1g [CJ)* 2, 2JO ps1g [C.S.)* 2 2JO ps1g [CJ)* 2, JOO ps1g [C.S.)* 2 150 ps1g Max. Allow. Temp TMA 428"F 428 "F [CJ)* 2, 500 "F [C.S.)* 2 428"F 650"F 428"F Motive Med. Press. 100 200 ps1g 5-150 ps1g 5-200 ps1g 5 150 ps1g 5-75 ps1g Max. Allow. Back Press. 150 ps1g* 3 14J ps1g * 3 19J ps1g * 3 14J ps1g * 3 68 ps1g * 3 Motive Medium *4 GT Series Saturated Steam GP Series Saturated Steam, Compressed Air, Nitrogen Pumped Medium * 5 GT Series Steam GP Series Steam, Water F1ll1ng Head * 6 fin) StandardJ6 Std.25 Std.25 Std.25 Std.42 M1rnmum30 Min.14 Min.12 M1n.18 [12w/CKF5M) M1n.JJ Steam/Air Consumption* 7 1.7 lb steam, 96 ft 3 compressed air* 8 GP Series) 2 lb steam, 100 ft 3 air* 8 - * S =screwed, F =flanged *2 C.. =cast iron, C.S. =cast steel *3 Motive medium pressure minus back pressure must be greater than 7 psi *4 Do not use with toxic, flammable or otherwise hazardous fluids. *5 Do not use for fluids with specific gravities under 0.85 or over, or for toxic, flammable or otherwise hazardous fluids. *6 Measured from grade. *7 At 5 psig back pressure, per,000 lb condensate. *B Equivalent consumption of air at 68 F under atmospheric pressure. Full product details (sizes, pressures, capacities and materials) are included in the individual specification data sheets (SDS). 8 2 l2y1 M1n.6 lcauton To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside of the specification range. Local regulations may restrict the use of this product to below the conditions quoted. lcauton DO NOT DSASSEMBLE OR REMOVE THS PRODUCT WHLE T JS UNDER PRESSURE. Allow internal pressure of this product to equal atmospheric pressure and its surface to cool to room temperature before disassembling or removing. Failure to do so could cause burns or other injury. READ NSTRUCTON MANUAL CAREFULLY TL\l CORPORATON 13901 South Lakes Drive, Charlotte, NC 28273-6790 Tel: 704-597-9070 Fax: 704-583-1610 E-mail: tlv@tlvengineering.com http://www.tlv.com For Technical Service 1-800 "TL V TRAP" Copyright TUf (O) FM/J. C4srJJ.btnmal, 11#. --.i,- -JllWli l:"...i- Manufacturer TL\l CD., LTD. Kakoga-, Japan is i!aj11md,.. LFllA Jd. to SO 90ll'l/14001 1809001 18014001 Pampnlet A24-04 Rev. 8/2017 Specifications subject to change without notice.