In accordance with the Department of Labor and Industry s statute , Subd. 11,

Similar documents
What you need to know about residential furnaces, air conditioners and heat pumps if you re NOT an HVAC professional

How to Take Basic Readings to Show Energy Efficiency

Promoting quality installation of central AC (and heat pump) systems

When Duct Sealing Kills HVAC Equipment and Efficiency

Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

Ductless and ducted mini splits- with case studies. Heat Pump and Air Condi1oning For Energy Design Conference By Mike D. Wilson- Dakota Supply Group

FG7T (C and L Series)

F25F Media Air Cleaner

TECHNICAL SPECIFICATIONS

Duct Design and Installation

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

Unico Training. Class for R E Michel Salesmen

EXHAUST FAN FLOW METER AND TRUEFLOW AIR HANDLER FLOW METER

Insulate your exterior walls. Air seal and insulate your attic

F150E Media Air Cleaner

HVAC for Raters & Inspectors

Welcome. High Performance Mechanicals for Houses That Work. Energy Design Conference - Duluth, MN. February 21 st, 2018

In accordance with the Department of Labor and Industry s statute , Subd. 11,

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

Air Bear Accu-Fit TM. Media Air Cleaner READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

SEVEN STEPS TO EFFECTIVE PRE- SEASON COOLING CHECKUPS

Understanding Fan System Effects

Troubleshooting the Indoor AHU as a Standard Product

F200E Charged-Media Air Cleaner

IDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions

Why Doesn t My HVAC System Work?

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

State of MN Energy Code Ventilation Review for 2017 Energy Design Conference. By 1. Mike D. Wilson Dakota Supply Group

Installation Guide.

Appendix 13. Categories of Cooling and Heating systems

Fan Selection. and Energy Savings

RG7D 1-Stage Heat Series

A/C Cooling Load calculation and measurement

Inffusers. idl20 (2 WAY) ids60 (4 WAY)

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Introduction to Fans. The Basics of Fan Principles and Terminology

Residential Water Heating

Energy-Efficiency Options for Residential Water Heating

In the past, contractors sized heating and cooling systems GETTING HVAC RIGHT

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

HVAC Systems What the Rater Needs to Know in the Field CALCS-PLUS

Residential Duct Mount Builder s Box Media Air Cleaner

Residential HVAC System Design

Technical Standards for the Air Conditioning and Heat Pump Professional BPI STANDARDS

Xc21 air conditioner up to seer Xc21

Checking the Charge on a Heat Pump in the Winter

Triple E New Construction. Doug Manthey Conservation Technologies Chad Trebilcock Minnesota Power

Upgrade Your Comfort

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Determining Real Time Performance of Residential AC Systems. Presented at the RESNET Conference San Antonio, TX February 28, 2006

2016 BUILDING ENERGY EFFICIENCY STANDARDS RESIDENTIAL HVAC ALTERATIONS

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

THE RIGHT SPEC. RIGHT NOW.

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Fans: Features and Analysis

TECHNICAL SPECIFICATIONS

For an administrative fee of $9.97, you can get an un-locked, printable version of this book.

HE-B Series Commissioning Report & User Guide

Model 8120 and 8126 Safety & Installation Instructions

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

INSTALLATION INSTRUCTIONS

G6RC Series TECHNICAL SPECIFICATIONS

Model 1750A/ 1770A Dehumidifier Installation Instructions

WAP Pressure Diagnostics Procedure. Page 1

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

PAR5. Product Specifications

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Pharmaceutical Facility Design

B SERIES ELECTRIC FURNACE

Selecting Fans and Determining Airflow for Grain Drying and Storage

Installation Instructions

TECHNICAL SPECIFICATIONS

Desiccant Dehumidifier

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

ICP Inverter Heat Pump Application Guideline

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

KIC Air Curtains. Technical Guide

CHAPTER IV AIR DISTRIBUTION AND BALANCE

INFRARED HVAC APPLICATION HVAC 101

TSTAT0101SC Recommended (order separately)

VERTICAL AHU INSTALLATION MANUAL BULLETIN

Combined Space and Water Heating: Making it Work

SECTION PLUMBING/HVAC FINAL TESTING, ADJUSTING AND BALANCING

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Unit Features & Benefits RQPM/RQRM Series

Product Rebates INDIANA

Site address. Ventilation Quantity (Determine quantity by using Table N or Equation 11-1) Continuous ventilation

Installation and Maintenance Manual IM Single Duct VAV Terminals. Group: Controls Part Number: IM 1093 Date: February 2015

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

Product Rebates MICHIGAN

ACCA Manual J Load Calculations

CERV Fan and Duct Sizing Information

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL SPECIFICATIONS

ENERGY FIT HOMES. In accordance with the Department of Labor and Industry s statute , Subd. 11,

TSTAT0201CW Recommended (sold separately)

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Transcription:

In accordance with the Department of Labor and Industry s statute 326.0981, Subd. 11, This educational offering is recognized by the Minnesota Department of Labor and Industry as satisfying 1 hours of credit toward Building Officials and Residential Contractors continuing education requirements. For additional continuing education approvals, please see your credit tracking card.

Quality Install Testing Procedures for Forced Air Systems Duluth Energy Design 2014

Quality Installation: Outcomes Installation practices have links to: ü Comfort ü Humidity Levels (dehumidification) ü Efficiency / Reduced Consumption ü Indoor Air Quality ü Increased Equipment Reliability

Why Test? SEER reduced when airflow not correct High Static = more power draw on *ECMs ECMs start to draw more power at.8 wc Must know system performance to consider ECM upgrade Furnace temperature rise *ECM = Electronic Commutating Motor

Why Test? Coils, filters, registers and Ductwork (flexible ducting, elbows, transitions) all add to Total External Static Pressure (TESP) High static pressure makes more noise Flow directly effects comfort No test is just a guess

Causes: Dirty Air Filters

Causes: Clean Air Filters.541 w.c. Drop on New Filter!

Causes: Dirty Blowers

Causes: Dirty Evaporator Coils

Causes: Poor Duct Design Red arrow to yellow arrow equals XX linear feet (equivalent)

Causes: Poor Duct Design

Causes: Poor Duct Design

Two Main Tests Total External Static Pressure Good for diagnosing system Air Flow CFM Verify actual air flow

What is Rated TESP?

What is Rated TESP?

What is TESP? Diagram courtesy of National Comfort Institute All components add resistance. Too much can restrict flow.

Testing TESP Static Pressure Tube and Manometer

Location of test holes Before AC coil, top of heat exchanger

Location of test holes After filter, blower compartment

Testing TESP Pitot Tube and Manometer Test hole locations

Testing TESP TESP = top of heat exchanger to bottom of blower (after filter) Pressure Drop = change over a distance (AC coil, filter, etc. Check rating (includes coil? Filter?)

Testing TESP Rooftop units TESP = Supply and return Pressure Drop = change over a distance (AC coil, filter, etc. Rated TESP, coil included in package units.

Testing TESP TESP = Add two numbers together Add these two readings together

Testing TESP Pressure Drop = subtract numbers (ignore ± sign) Subtract These Two Readings

TESP Results Think Golf and Blood Pressure Lower is better High numbers indicate a problem And a need for.more work on your game or on the forced air system

Testing Air Flow (CFM) Static Pressure affects air flow Air flow determines efficiency Need air flow to set refrigerant charge Need 400~ cfm per ton of cooling Need to know # of tons

Measuring Air Flow True Flow Meter Energy Conservatory.com

True Flow Meter Energy Conservatory, MN Manufacturer Advantages: very accurate, fairly easy to set up Disadvantages: Additional equipment cost, needs filter slot that fits plates, results can be effected by poor duct design

True Flow Meter Install in filter slot Generally fits all sizes and configurations possible Flow plate automatically averages flow rates Need manometer (pressure gauge) to make readings

Testing Air Flow Hot Wire or Mini-Vane Anenometer

Testing Air Flow Hotwire or Mini-Vane Anenometer

Hot Wire or Mini Vane Advantages: Fast and east to use, accurate (when compared to True Flow meter) Disadvantages: Additional Equipment cost, need linear section of duct

Hot Wire or Mini Vane Drill holes in duct Take readings Meter automatically calculates averages of flow rates Test time: about 5+ minutes

Fan Curve Tables Advantages: Low cost, Quick and easy (if table available), good for troubleshooting Disadvantages: Fan tables sometimes not available (can use generic), duct configurations may cause turbulence

Fan Curve method Take readings Know fan speed setting, rated TESP Match readings off fan table to find CFM Read the fine print

The fine Print Fan Curve Table

The actual Fine Print 1. CFM in chart is without filter(s). Filters do not ship with this furnace but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed.

The actual Fine Print 5. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. i.e. have to actually test TESP to know if it exceeds rated value

Possible Solutions Less restrictive filters Regular filter changes, maintenance Curved ductwork, turning vanes Registers with more open free air space

Possible Solutions Add more return air Add more supply air Add better filtration Clean blower wheel Clean evaporator coil

Possible Solutions Smooth ductwork, not flex duct Proper sizing / design of ductwork Sealing ductwork

How Much Air Flow is Needed? Depends on furnace type Rules of thumb per 10,000 BTU: Ø Atmospheric draft: 100 cfm Ø Induced draft: 130 cfm Ø Condensing: 150 cfm Example: 80,000 BTU induced draft furnace Needs (80/10) x 130 = 1040 cfm

How Much Air Flow is Needed? For air conditioning Rules of thumb 400 per ton of cooling Can use 350 450 cfm Lower for better de-humidification Example: 2 ton AC unit Needs 2 x 400 = 800 cfm

Practical Applications How Much Airflow Is Required? CFM = Btu(output)/1.08 X ΔT 80K Furnace 92% Temp Rise 35-65 73,600 / 1.08 X 55 = 1247 CFM! 2 Ton AC = 800 CFM 1.08 = 60 min (hours to min) X.75 (average density) X.24 (specific heat)

Practical Applications Replacing Old 70% 100K with New 95% 80K Furnace What will be the effect on static pressure? SP2 = SP1 x (CFM2/CFM1)²

Practical Applications SP2 = SP1 X (CFM2/CFM1)² Original Furnace has.6 TESP and 1000 CFM New Furnace is 76,000 output/1.08 X 55 (59) = 1288 CFM SP2 =.6 X (1200/1000)² SP2 =.6 X 1.44 =.86 TESP SP2 =.86! 30% INCREASE!

Practical Applications What size filter do I Need? CFM/Face Velocity = Area in SQ FT Face Velocity around 300 FPM, 400 MAX 1200/300 = 4 Sq FT of Surface Area 20x25 inch filter has 3.47 Sq Ft 16x20 inch filter has 2.22 Sq Ft

Practical Applications What is my actual furnace Btu output? Btu = CFM X 1.08 X Temperature Rise Btu = 600 X 1.08 X 55 = 59,400 Compare to Name Plate Rating

Potential Problems Found Restrictive filter (up to 50% drop in flow) Restrictive designer registers

Potential Problems Found Dirty AC Coils Owner did not know this coil existed

Potential Problems Found Undersized Supply ducts Plenum Undersized Ductwork

Challenges Additional testing often means more cost Alterations to ductwork can add cost to proposal Low Bid vs. most responsible bid Customer education Contractor education

Benefits Energy Savings (that is expected and predicted) Increased Comfort Better customer service Longer Equipment Life Utility Rebates for Energy Savings

My office doesn t get any heat.

Thank You Bruce Stahlberg, CEM Affordable Energy Solutions, Inc. Minneapolis, MN Steve Hokanson Total Home Performance LLC Jordan, MN