Tool-free LC connections for HPLC, UHPLC and nano LC systems

Similar documents
The Complete and Easy Guide to Configuring Your Specific Thermo NanoLC for Mass Spec Analysis

Sensitive Determination of Microcystins from Environmental Waters Using On-Line SPE

detectors UltiMate 3000 Variable Wavelength Detectors

Thermo Scientific Dionex UltiMate 3000 Fluorescence Detectors

Spark Holland introduces

Injection/Trapping. Analysis

Agilent 1290 Infinity II Vialsampler Data Sheet

Agilent InfinityLab Online SPE Solution

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

Customised HPLC Systems for Highest Performance

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

Mariner Microspray and Low-Flow Electrospray Fused Silica Spray Tip and Capillary Kit. Operating Instructions. 1 Product Description.

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

Nexera-i Specifications Prominence-i Specifications

Thermo Scientific Dionex SolEx SPE Cartridges

Thermo Scientific Dionex AutoTrace 280 SPE Instrument. Automate Large-Volume. Solid-Phase Extractions

Agilent 1290 Infinity II Online SPE Solution

InfinityLab Quick-Connect Bio-inert Heat Exchanger

Rapid Quantification of Polar and Semipolar Pesticide Metabolites with Combined Online SPE and Direct Injection

300 series HPLC autosamplers

SEC-MALS Noise Assessment and Cleaning Guide

Analysis of Pharmaceuticals and Personal Care Products in Groundwater by Online SPE and LC/MS/MS

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Agilent GC Solutions. A Convenient Deans Switch Method for the Analysis of Permanent Gases in Various Matrices by Gas Chromatography CAG

HISTORY OF VARIAN CAPILLARY INJECTORS

Application Note. The Agilent 1200 Infinity Series Online SPE Solution for the Highest Sensitivity. Author. Abstract.

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

ACQUITY UPLC HT Column Heater Instructions

On Line SPE LC/MS/MS Applications

General Animal Injections

Universal NanoFlow Sprayer Installation and Maintenance Guide

Agilent 1260 Infinity Multi-Detector Suite

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

CALIDUS tm the Modular micro Gas Chromatograph

Customers should provide all necessary operating supplies upon request of the engineer.

Vanquish. Split Samplers VH-A10, VF-A10. Operating Manual

An Advanced Heat Exchanger for the Agilent 1290 Infinity Thermostatted Column Compartment

SystemsQT for Waters Alliance HPLC Systems (Revision G)

Online SPE-UHPLC-MS. CHRONOS for Control & System Integration. Flexible autosampler for sample preparation. Superior UHPLC system for analysis

FREESTYLE SPE UNIQUE POSSIBILITIES FOR SOLID PHASE EXTRACTION

Supra-Clean and Supra-Poly SPE Solutions. Solid Phase Extraction Columns

GE Healthcare. Mixer M-925. Instructions

Improved HPLC Separations at Elevated Temperatures Using a New Stand-alone Preheater

Common Features of DX-600 Modules

FIXED GAS ANALYZER (FGA)

This document is a preview generated by EVS

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Use of Automation to Achieve

DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation

HITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018

GC Injectors. GC Injectors

API LC/MS/MS TurboIonSpray Ion Source Manual Table of Contents

DYE QUALITY CONTROL REFERENCE MATERIAL KIT

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Thermo Scientific Dionex Integrion HPIC System

Who is GBC Scientific Equipment?

Agilent 1200 Series Diode Array and Multiple Wavelength Detectors

Application Note. Authors. Abstract

TYPES AND APPROPRIATE INJECTORS

Waters 2767 Sample Manager, Injector, and Collector Installation and Maintenance Guide

On-line SPE Enrichment of Trace Organic Contaminants in Water and Juices

Systems. Visit us at

1320 Detectors. 1 of 30. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual

Agilent 1200 Series Variable Wavelength Detector

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

Direct Injection and Online SPE LC/MS/MS for the Determination of Pharmaceuticals and Personal Care Products (PPCPs) in Water Samples

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box

IMPROVING THE QUANTITATIVE REPRODUCIBILITY OF AN ATMOSPHERIC PRESSURE CHEMICAL IONISATION SOURCE FOR GC/MS AND GC MS/MS ANALYSIS

Agilent 1100 Series Refractive Index Detector. Reference Manual

PRODUCT CONFORMITY CERTIFICATE

Rhino SD2/XD2 ARW Air Circuit Module for 125-mm Frames

An Automated SPE Procedure and Analysis for the Extraction of Chlorpromazine and Thioridazine from Plasma Application Note 213

Agilent 1290 Infinity II LC

Eldex Column Heater. Operator s Manual

ACQUITY UPLC H-Class Column Compartments Operator s Overview and Maintenance Information

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

Varian 356-LC RI Detector

High resolution mass spectrometry (HRMS*) in Graz

TL-105 COLUMN HEATER

151/152 UV/VIS Detectors User s Guide

DISSOLVED GAS ANALYZER (DGA)

Wide-Bore Heat Exchanger Installation Kit ( )

AppNote 3/2009. Automation of Solid Phase Extraction Methods using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

DETERMINATION OF PAH In Particulate Matter PM10 With SPE/EVAporation

Xenon Lamp Replacement Guide

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

Solid Phase Extraction using the 96-well Format ISOLUTE -96 Fixed Well Plates and ISOLUTE Array 96-well Plates

Perfect Separation Solutions (Bio)SECcurity²

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

Integrated Process Solutions. Series 49. Thermal Management System

Target Platform. Considerations. it is recommended that the server and bandwidth are optimised for acceptable performance.

Turbidity Systems. Inline Turbidity Measurements For More Visibility Into Your Process. INGOLD Leading Process Analytics

Automação de SPE utilizando sistema robótico Triplus RSH autosampler. Nova Analitica

Use of Automation to Achieve High Performance SPE

Technical specifications of FT-IR Spectrometer

Installing the Agilent CE ESI-MS Sprayer Kit (G1607A)

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Transcription:

PRODUCT SPECIFICATIONS Thermo Scientific Viper and nanoviper Fitting systems Tool-free LC connections for HPLC, UHPLC and nano LC systems Benefits Provides virtually zero-dead volume fingertight connections Easy to install tool-free and reusable capillaries (1/32 in. OD) Fits narrow connections such as 10-port valves Always reproducible LC connections Supports operating pressures up to 1,500 bar (22,000 psi) Works with virtually any system, valve and column Keywords Viper, nanoviper, Fittings, LC connections The Thermo Scientific Viper and Thermo Scientific nanoviper Fittings provide tool-free connections designed to be used for the entire fluidic pathway in all LC systems to improve chromatographic results. Offering virtually dead-volume free LC connections, Viper and nanoviper fittings require no tools for installation, and combine simplicity with high performance. Viper and nanoviper connections can be used on all LC modules, valves, and columns quickly, independent of different connection geometries and system backpressures. Advantages of Viper and nanoviper fittings Available in different lengths: from 65 to 1100 mm, or custom lengths Available in different inner diameters: from 10 µm (0.0004 in.) to 150 µm (0.006 in.) in nanoviper design and from 100 µm (0.004 in.) to 180 µm (0.007 in.) for standard applications Available in different materials: stainless steel (SST),, fused-silica or biocompatible

Specifications Thermo Scientific Viper Fitting System SST Flexible stainless steel (SST), SST 131 MPa (1,310 bar; 19,000 psi) Maximum temperature limit 120 C 100 µm (0.004 in.), 130 µm (0.005 in.), 180 µm (0.007 in.) Various lengths from 65 mm to 950 mm Thermo Scientific Viper Fitting System Biocompatible 34.5 MPa (345 bar; 5,000 psi) 65 µm (0.0026 in.), 90 µm (0.0035 in.), 130 µm (0.005 in.) Various lengths from 65 mm to 850 mm Thermo Scientific Viper Fitting System Biocompatible, 151 MPa (1,517 bar; 22,000 psi) Maximum temperature limit 120 C 100 µm (0.004 in.), 130 µm (0.005 in.), 180 µm (0.007 in.) Various lengths from 65 mm to 950 mm Thermo Scientific nanoviper Fitting System Shielded Fused silica -shielded fused silica, fused silica 120 MPa (1,200 bar; 17,400 psi) Maximum temperature limit 120 C Various ID from 10 µm (0.0004 in.) to 150 µm (0.006 in.) Various lengths from 70 mm to 1100 mm Custom lengths available* * Please contact us for more information on nanoviper capillaries in custom length. Viper and nanoviper capillaries with color coding for easy recognition

Ordering Information In the U.S., call (800) 346-6390 or contact the Thermo Fisher Scientific Regional Office nearest you. Outside the U.S., order through your local Thermo Fisher Scientific office or distributor. Refer to the following part numbers. Length (mm) Viper Fitting Systems SST 100 µm ID 0.004 in. ID 130 µm ID 0.005 in. ID 180 µm ID 0.007 in. ID 65 6040.2207 6040.2307 6040.2357 100 6040.2322 150 6040.2215 6040.2315 6040.2360 200 6040.2327 250 6040.2225 6040.2325 6040.2385 350 6040.2235 6040.2335 6040.2375 450 6040.2245 6040.2345 6040.2365 550 6040.2255 6040.2305 6040.2355 650 6040.2265 6040.2310 6040.2395 750 6040.2320 6040.2370 850 6040.2330 6040.2380 950 6040.2340 6040.2390 Length (mm) 65 µm ID 0.0025 in. ID Viper Fitting Systems Biocompatible 90 µm ID 0.0035 in ID 65 6041.9075 (L 75 mm) 130 µm ID 0.005 in. ID 100 µm ID 0.004 in. ID 6042.2306 130 µm ID 0.005 in. ID 180 µm ID 0.007 in. ID 150 6041.5615 6041.5616 6042.2320 6042.2315 250 6041.5625 6041.9025 6042.2330 6042.2327 350 6042.2340 6042.2337 450 6042.2350 6042.2365 550 6042.2360 6042.2355 650 6041.5665 6042.2370 6042.2380 750 6041.5675 6042.2390 6042.2373 6042.2375 850 6041.5685 950 6042.2395 6042.2385 Length (mm) 10 µm ID 0.0004 in. ID nanoviper Fitting Systems Shielded Fused Silica 20 µm ID 0.0008 in. ID 50 µm ID 0.002 in. ID 75 µm ID 0.003 in. ID 100 µm ID 0.004 in. ID 150 µm ID 0.006 in. ID 70 6041.5120 6041.5123 6041.5126 6041.5810 6041.5817 150 6041.5118 (L 180 mm) 6041.5121 6041.5124 6041.5127 6041.5811 6041.5818 250 6041.5730 6041.5812 6041.5819 350 6041.5240 6041.5540 6041.5735 6041.5813 6041.5820 450 6041.5814 6041.5821 550 6041.5260 6041.5560 6041.5760 6041.5815 6041.5822 650 6041.5275 6041.5575 6041.5775 6041.5824 750 6041.5280 6041.5580 6041.5780 6041.5816 6041.5823 850 6041.5785 950 6041.5122 6041.5125 6041.5128 1100 6041.5711 6041.5828

Special Viper Fitting Capillaries Active Pre-heater,, ID L, 100 µm 380 mm (for Vanquish Column Compartment H) 6732.0110 Passive Pre-heater,, ID L, 100 µm 530 mm (for Vanquish Column Compartment H) 6732.0174 Post Column Cooler,, ID L, 100 µm 240 mm (for Vanquish Column Compartment H) 6732.0510 Passive Pre-heater, SST, ID, 100 µm (for TCC-3000) 6722.0510 Passive Pre-heater, SST, ID, 130 µm (for TCC-3000) 6722.0530 Passive Pre-heater, SST, ID, 180 µm (for TCC-3000) 6722.0540 Passive Pre-heater, SST, ID, 250 µm (for TCC-3000) 6722.0550 Passive Pre-heater, coated steel, biocompatible, ID, 130 µm (for TCC-3000) 6723.0232 Passive Pre-heater, coated steel, biocompatible, ID, 250 µm 7 µl (for TCC-3000) 6723.0242 Passive Pre-heater, coated steel, biocompatible, ID, 250 µm 11 µl (for TCC-3000) 6723.0252 Passive Pre-heater,, ID, 100 µm (for TCC-3000) 6723.0235 Passive Pre-heater,, ID, 180 µm (for TCC-3000) 6723.0245 Post Column Cooler, SST, ID, 130 µm (for TCC-3000) 6730.0008 thermally insulated, ID L, 100 µm 300 mm 6083.2405 thermally insulated, ID L, 130 µm 500 mm 6083.2411 Special nanoviper Fitting Capillaries nanoviper, ID L, 20 µm custom length 6041.5299 nanoviper, ID L, 50 µm custom length 6041.5599A nanoviper, ID L, 75 µm custom length 6041.5799 nanoviper, thermally insulated, ID L, 75 µm 300 mm 6083.2415 UHPLC waste, ID OD L, 75 µm 360 µm 550 mm 6041.5289 Liquid Junction column out, ID OD L, 20 µm 360 µm 550 mm 6041.5290 Nano LC column to MS tubing, ID OD L, 20 µm 280 µm 1 m 6041.5292 Nano LC column to MS tubing, ID OD L, 20 µm 360 µm 1 m 6041.5293 Nano LC column to MS tubing, ID OD L, 50 µm 280 µm 1 m 6041.5294 Nano LC column to MS tubing, ID OD L, 50 µm 360 µm 1 m 6041.5295 Viper Accessories Blind Plug, biocompatible (titanium) 6040.2303 Union, SST 6040.2304 Calibration Tool 6040.2312 Inline Filter, titanium, av. frit pore size 0.5 µm 6036.1045

Viper Fitting Kits for UltiMate 3000 and Vanquish Systems SD System RS System Vanquish Viper Capillary Kit for LPG, DGP or ISO pumps 6040.2302 6040.2301 Viper Capillary Kit for HPG pumps 6040.2309 6040.2308 Viper Capillary Kit for Biocompatible RS systems 6841.2301 MS Connection Kit for systems without UV detector 6720.0355 6720.0370 MS Connection Kit for systems with UV detector 6720.0365 6720.0375 MS Connection Kit for systems with OAS autosampler without UV detector 6720.0372 MS Connection Kit for systems with OAS autosampler with UV detector 6720.0377 MS Connection Kit for Vanquish systems with and without UV detector 6720.0405 Viper Solution Kit Online SPE 6040.2802 6040.2801 Viper Solution Kit Tandem Operation 6040.2804 6040.2803 Viper Solution Kit Parallel Setup 6040.2810 6040.2809 Viper Solution Kit Application Switching 6040.2806 6040.2805 Viper Solution Kit Method Scouting 6040.2808 6040.2807 6036.2807 Viper Solution Kit Method Scouting, ID 100 µm, biocompatible 6042.2807 Viper Solution Kit Method Scouting, ID 180 µm, biocompatible 6042.2808 Viper Solution Kit Inverse Gradient 6040.2819 6040.2820 nanoviper Fitting Kits for RSLCnano Systems Direct Injection nano LC kit 6720.0300 Direct Injection capillary LC kit 6720.0305 Preconcentration nano LC kit 6720.0310 Preconcentration capillary LC kit 6720.0315 Preconcentration micro LC kit 6720.0320 2D salt plugs kit 6720.0325 Automated off line SCX-RP peptides kit 6720.0330 Tandem nano LC kit 6720.0335 Automated off line RP-RP peptides kit 6720.0340 MS Connection kit 6720.0345 OQ/PQ kit, NCS, NCp 6720.0360 EASY-Spray connection kit 6720.0395 Upgrade Kit ProFlow Flowmeter 6041.3003 To learn more about RSLCnano applications and how to configure nano LC for MS analysis, please download: The Complete and Easy Guide to Configuring Your Thermo Scientific Nano LC for Mass Spectrometric Analysis Thermo Scientific UltiMate 3000 RSLCnano - Standard Application

Find out more at www.thermofisher.com/viper 2017 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representatives for details. PS72278-EN 0617M