RT8220A-2 is a transmitter to be used with the RV8310D receiver/valve.

Similar documents
Q382A,B Pilot Burners

WSK300 Multifunction Wall Control

Installation & Troubleshooting Requirements

IFT-RC400 IntelliFire Touch Remote Control

e - p a r t s. c o m Freestanding Direct Vent Fireplace Models: RFSDV24, RFSDV34 Installation Instructions and Homeowner s Manual

PROBLEM CAUSE SOLUTION

Travis 3003 User s Manual

Operation & Maintenance Manual

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

DT/DTH/DR/DRH MERIT SERIES

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

PFS. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLATION AND OPERATION INSTRUCTIONS

Owner s Manual. Part Number 33CS250-RC

OWNER S MANUAL. Part Number P RF

DT-2 & DR-2 MERIT SERIES

ETN24-P/PD-FC-SUPER2. Owner's Manual - Installation and Operating Instructions

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Owner s Manual. Part Number 33CS250-01

Models #CSK-335 #CSK-335-RF. CHASKA - XL Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL

Installation, Start-Up, and Operating Instructions

Models #CSK-31 #CSK-31-RF. CHASKA Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL

TABLE OF CONTENTS SAFETY

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

C6097A,B Pressure Switches

REMOTE CONTROL UNIT. Ignition Open the gas supply tap. Press the switch (5) of the gas valve in I position.

Operation 8085C ENGLISH. Customer Support: or Visit our webiste Printed in China

Buttons on remote controller

ETN1000/MIGA - Operating manual

24 VAC SYSTEM CONTROL KIT

534I, 650, 739I, 1200, 1300, 1500, MF28I

Customer Service...1. Calibration...8. Inspection...9. Lighting Cleaning Features Control Box Digital Timers...

USER S MANUAL. Remote Controller 88-MACC007-1A-EN

OWNER S MANUAL. Part Number P

AF-Q100VX AF-Q120VX AF-Q100VX, AF-Q120VX) 15%

AirTrak. Digital Control System. User Manual. Touchscreen Systems

610 AC3 CONTROL KNOB (OFF, PILOT, ON) TEMPERATURE SELECTION KNOB ON-OFF REGULATING THERMOSTAT THERMOELECTRIC SAFETY DEVICE.

GPC PASTA PRO INSTALLATION & USER OPERATION MANUAL

24 VAC SYSTEM CONTROL KIT

FIREPLACE INSTALLATION

Energy Saver Commercial Gas Millivolt (DM) Models

INITIALIZATION / INSTALLATION

Model: 1001T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS

IFT-RC400 & IFT-ACM IntelliFire Touch Remote Control & Auxiliary Control Module Installation Instructions

Conversion of Gazco Upgradable Controls to Battery Remote Control

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

T7100D Microelectronic Conventional Thermostat

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

OWNER S MANUAL. Part Number P CONTENTS

13. TROUBLESHOOTING INSTALLER ONLY PROBLEM CAUSE SOLUTION (CERTIFIED GAS TECHNICIAN ONLY)

VFI Series Vent Free Gas Fireplace Installation & Operating Instructions

GAS -FIRED VENTED ROOM HEATERS MODEL 61TV

Model: Edge-HC. 1 edge-hc

AVFLST Vent Free See Through Fireplace System Installation & Operating Instructions

TP970 and TP9600 Series Pneumatic Thermostats

Home and Building Control Home and Building Control Helping You Control Your World

O PE R AT I ON HO851G REVOLVING TRAY OVEN. MODEL HO851G GAS ML Pan ML Pan ML Pan ML Pan

MODEL 329 MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A FREESTANDING FIREPLACE OR WITH AN OPTIONAL WOODEN SURROUND.

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

GV60 REMOTE CONTROL user guide

REPLACEMENT PARTS LIST WARNING

Remote Control Features & Functions

FLAME GRILL GAS-FIRED (NAT & LPG) The Clay Oven Company Ltd. Leading manufacturers of clay ovens since 1974

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

MODEL 34 MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL SURROUND.

Programmable Thermostat

Dometic Manual Refrigerators

Technical Updates and Kozy Heat Programs 2017 Kozy Heat Dealer Meeting - Okoboji, IA

AdaptAire. Digital Control System. User Manual

TP970 Series CONVERTASTAT Kits

Siemens RDY2000BN. Start Up Guide

Operating Functions Temperature Parameters

Model: TS/R-2A INSTALLATION AND OPERATING INSTRUCTIONS

DANGER HOMEOWNERS MANUAL. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

EF3003 SF3003 DF3003

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

Commercial/Industrial Combustion Control Level Three Announcement

USER S INFORMATION MANUAL

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

MODEL 36 MAY BE INSTALLED AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL WOODEN SURROUND

Product Bulletin Advisement

3. Turn on the electrical power supply to the dryer, and move the safety disconnect handle mounted on the dryer s upper power box to on.

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

ELECTRONIC COMMUNICATING THERMOSTAT

CT1500, CT1501, CT1502, CT1503

CSD-1 COMMERCIAL BOILER CONTROLS

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

User manual. Logano GC 124 II. Gas boiler

INSTALLATION AND OPERATING MANUAL

600 Watt Dimmer Install Guide

User Manual Version 1.0 Revision 001

WARNING: This appliance is equipped for Natural and Propane gas. Field conversion is not permitted other than between natural or propane gases.

INSTALLATION AND OPERATING INSTRUCTIONS

Installation, Start-Up, and Operating Instructions

Keys for base station: 1. MODE 2. CHANNEL 3. MAX/MIN 4. UP/(C/F) 5. SET/(AL.ON/OFF) 6. DOWN/(12/24) 7. SNOOZE 8. ALERT 9. RESET

USER S INFORMATION MANUAL

Transcription:

Honeywell draft User s Manual RT8220A-2 is a transmitter to be used with the RV8310D receiver/valve. RF MILLIVOLT SYSTEM The RF millivolt system consists of a RV8310D receiver/valve, RT8220A or RT8220A-2 transmitter, and a pilot burner with two Q313 thermopiles. The RV8310D is flame powered with two thermopiles, and has flame powered modulation, line powered fan modulation, and a quick dropout function of 30 seconds or less with loss of pilot flame. The receiver has a manual switch. If the switch is in the REMOTE mode and the pilot is lit, the transmitter can control the main valve, flame modulation, fan control, and set temperature. If the switch is in the LOCAL mode and the pilot is lit, the valve will be at the highest fixed pressure setting and the transmitter cannot turn off the main burner. The transmitter will control the fan but not the flame modulation. The pilotstat knob in the valve portion of the control provides for the OFF mode for the RV8310D. When the pilotstat knob is rotated to the OFF position, the pilot and main valve are turned off and the transmitter provides no control. The valve portion of the control has a pilotstat, pilot adjustment, European style inlet and outlet pressure taps, 7/16-24 UNS pilot connection, and 3/8 NPT inlet and outlet connections. The capacity is 60,000 BTUH at 1 p.d.. The regulator is dedicated natural gas or LP. The receiver/valve is rated at 175 F. If the ambient temperature rises above 185 F, the output pressure is reduced until the ambient temperature drops below 175F. INSTALLATION OF RV8310D 1. Use only on a vented appliance. 2. Turn off the gas supply at the appliance service valve before starting the installation, and perform a Gas Leak Test after the installation is complete. 3. Mount valve 0 to 90 degrees, in any direction including vertically from the upright position of the gas control knob

4. Attach four thermopile leads. Two leads are white wires with a terminal. They are attached to the terminals with a white dot on the cover next to them. The two leads with the red wires attach to the remaining terminals. OPERATION 1. Turn the pilotstat knob counterclockwise from OFF to the PILOT position, push the knob down, and hold in position. The pilot valve opens and allows gas to flow to the pilot burner. 2. Push the plunger on the piezo until the pilot burner is lit. When the pilot burner is lit, the LED on the control will come on after approximately 40 seconds and will be continuously red. When the light turns off which will be approximately 10 seconds after it has been continuously red, the receiver/valve is fully powered. 3. Release the knob. The shaft will move upward. The pilot burner should now stay burning. If the pilot burner goes out, repeat step 2. 4. Turn the knob counterclockwise to the ON position. If the manual switch is in the LOCAL position, the main burner will turn on immediately. 5. On the initial use of a transmitter, a recognition operation is required between the receiver/valve and transmitter. Change the switch from LOCAL to REMOTE. Press the fan or flame button on the transmitter within 30 seconds. The LED will blink indicating that the transmitter will now work with the receiver/valve. If the switch continues in the REMOTE position, the transmitter will now control the main valve, flame modulation level, and fan control. 6. If the manual switch is in the LOCAL position, the valve will be at the highest fixed pressure setting. The transmitter will control the fan only. SHUT OFF PROCEDURE 1. If the manual switch is in the REMOTE position, the RT8220A transmitter can shut off the main burner and fan. However, the control is still on and a command from the transmitter can turn on the main burner or fan. 2. To shut off the system, turn the pilotstat knob clockwise to the OFF position. This action closes the main gas and safety valves. The transmitter cannot turn on the main burner or fan. TRANSMITTER RT8220A/RT8220A-2 The transmitter controls the flame level, fan speed, and room temperature. The three basic operating modes are the OFF mode, ON (manual) mode, and AUTO mode.

In OFF mode the fireplace flame and fan are off. In ON mode the flame level and fan speed can be adjusted by the user. In the AUTO mode the RT8220A is used as a thermostat to allow the fireplace to automatically control the temperature of the room. There are six buttons on the remote. The buttons are the mode, delay timer, flame, fan, up, and down buttons. The mode button changes the operating mode of the RT8220A. The delay timer enables or disables a shutoff timer function. The flame and fan buttons are used to change the flame or fan levels. The up and down keys are used to change the temperature setting or flame, fan, and delay timer values. Below is a detailed description of how to use the transmitter. OFF MODE In the OFF mode, the display will show OFF and the room temperature. If the receiver is in REMOTE mode, the fireplace will shut off. ON(manual) MODE In the ON mode, the room temperature, flame and fan levels will be shown. MANUAL will appear next to both the flame and fan icons. When the control is in the ON mode, the flame and fan levels, and delay timer are changed with the up and down buttons. To change the flame level, press the flame button followed by an arrow key. To change the fan level, press the fan key followed by an arrow key. Pushing the arrow key once will change the level by one unit. DELAY TIMER MODE The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. To change the timer level, press the time key followed by an arrow key. Pushing the key once will change the timer by 10 minutes. AUTO MODE In the AUTO mode the room temperature, set temperature, flame, and fan levels will be shown on the display. The word AUTO will appear next to both the flame and fan icons. When the control is in the AUTO mode, the main burner will turn on/off or modulate based on the heat needed to maintain the set temperature. The flame level will change automatically to optimize the heat output needed to maintain the set temperature. To

change the set temperature, press the up or down key. Pushing a key once will change the temperature by one degree. In the AUTO mode the fan speed will increase with increasing flame height or decrease with decreasing flame height. AUTO is displayed next to the flame and fan icons. FAN OVERRIDE DURING AUTO MODE If a lower or higher fan speed is desired when operating in the AUTO mode, the fan speed can be overridden by pushing the fan button followed by the up or down key. Pushing a key once will change the fan level by one unit. In this mode AUTO is displayed next to the flame icon and MANUAL is displayed next to the fan icon. CHANGE BETWEEN F/C TEMPERATURE UNITS Push the up and down arrow keys simultaneously for at least 3 seconds to toggle between F and C units. DISABLE THERMOSTAT FUNCTION To disable the thermostat function in the AUTO mode, push the time and down keys simultaneously for at least 3 seconds. OPERATION 1. Remove cover on the backside of the transmitter. Install 3 AAA batteries and as shown and reattach cover. 2. Once steps 1-3 in RV8310D Operation have been completed, receiver/valve and transmitter are now ready. Press any button on transmitter for recognition process to occur between the receiver/valve and transmitter. 3. Use functions as described in TRANSMITTER section. Copyright Draft 1999 Honeywell, Inc. All Rights Reserved Home and Building Control Honeywell, Inc. Honeywell Plaza P.O. Box 524 Minneapolis, MN 55408